Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Neutron detector characterization for SCINTIA array

SCINTIA is a new detector array of organic scintillators under development at the Inst. for Reference Materials and Measurements (IRMM). The present design of SCINTIA includes NE213, p-terphenyl and Li glass neutron detectors positioned in a spherical configuration around the target. The properties of a novel p-terphenyl neutron detector to be used with SCINTIA have been investigated using photon sources and neutrons from a time tagged {sup 252}Cf(sf) source. The results show that the p-terphenyl crystal has better energy resolution, increased proton light output and neutron efficiency when compared to a similar size NE213 equivalent neutron detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances toward a transportable antineutrino detector system for reactor monitoring and safeguards

Nuclear reactors have served as the neutrino source for many fundamental physics experiments. The techniques developed by these experiments make it possible to use these very weakly interacting particles for a practical purpose. The large flux of antineutrinos that leaves a reactor carries information about two quantities of interest for safeguards: the reactor power and fissile inventory. Our SNL/LLNL collaboration has demonstrated that such antineutrino based monitoring is feasible using a relatively small cubic meter scale liquid scintillator detector at tens of meters standoff from a commercial Pressurized Water Reactor (PWR). With little or no burden on the plant operator we have been able to remotely and automatically monitor the reactor operational status (on/off), power level, and fuel burnup. The initial detector was deployed in an underground gallery that lies directly under the containment dome of an operating PWR. The gallery is 25 meters from the reactor core center, is rarely accessed by plant personnel, and provides a muon-screening effect of some 20-30 meters of water equivalent earth and concrete overburden. Unfortunately, many reactor facilities do not contain an equivalent underground location. We have therefore attempted to construct a complete detector system which would be capable of operating in an aboveground location and could be transported to a reactor facility with relative ease. A standard 6-meter shipping container was used as our transportable laboratory - containing active and passive shielding components, the antineutrino detector and all electronics, as well as climate control systems. This aboveground system was deployed and tested at the San Onofre Nuclear Generating Station (SONGS) in southern California in 2010 and early 2011. We will first present an overview of the initial demonstrations of our below ground detector. Then we will describe the aboveground system and the technological developments of the two antineutrino detectors that were deployed. Finally, some preliminary results of our aboveground test will be shown. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High efficiency method of fast neutron detection by oxide scintillators for detection systems of fissionable radioactive substances

Comparative measurements and analysis of detection efficiency (DE) of fast neutrons from {sup 239}Pu-Be source have been carried out in a broad energy range En {approx} 0.1 ./. 10 MeV using oxide scintillators BGO, GSO, CWO, ZnWO, ZnSe(Te, O), as well as LiI(Eu). DE of fast neutrons by heavy oxide scintillators was found to be very high ({approx} 40-50 %). The neutron inelastic scattering reaction (n, n'y) is considered as the most probable interaction mechanism of neutrons with nuclei of heavy oxide scintillators. It is concluded that heavy oxide scintillators, which are at the same time efficient gamma-detectors, allow creation of a highly efficient gamma-neutron detector ensuring high detection efficiency of fissionable radioactive substances. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MA-NRBC: First successful attempt for neutron gamma discrimination in plastic scintillators

In this paper, a new electronic hardware and algorithms enabling discrimination between neutron and gamma in plastic scintillators together with the first associated experimental results, are presented. This electronic platform is mainly based onto a quad 200 MHz ADCs. Using phase rotating, it is possible to sample the signal up to 800 MHz equivalent, with 8 bits precision. This sampling frequency allows a real time signal processing. Despite all previous work, we have shown during this study that it is possible to discriminate neutron from gamma in plastic scintillators even for low energy neutrons (less than 10 MeV). Two patents have been accepted and registered; the first deals with the intrinsic signal processing and the second with thermal stabilization methods of photomultiplier tubes. The system could be used up to 100 000 events per second (both gamma and neutron). This system is currently dedicated to homeland security devices; this is due to its response time (in the order of 1 up to 3 seconds). The next step is to implement the thermal stabilization algorithm in the FPGA and micro-controller to obtain a global system free from any trouble caused by the environment thermal variations. This aspect of the research is crucial for measurements in the field. The time response should also be improved to make it a reliable alternative to Helium-3 shortage for neutron detection at borders checkpoint. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nucifer: A small electron-antineutrino detector for fundamental and safeguard studies

The Nucifer detector will be deployed in the next few months at the Osiris research reactor in France. Nucifer is a 1-ton Gd-doped liquid scintillator detector devoted to reactor antineutrino studies. It will be installed 7 m away from the compact core of the Osiris reactor. The design of such small volume detector has been focused on high detection efficiency and good background rejection. Over the last decades, our understanding of the neutrino properties has been improved and allows today the possibility to apply the detection of antineutrinos to automatic and to non intrusively survey nuclear power plant. This has triggered the interest of the International Atomic Energy Agency (IAEA), which is interested by developing new safeguard techniques for next generation reactors. The sensitivity of such technique has to be proved and demonstrated. On the other hand there is still some issues in our understanding of the neutrino properties as the observed deficit in the antineutrino rate at short distances (< 100 m) that can not be explained by oscillations in the 3-flavors neutrino model. If a global systematic error is rejected, such anomaly opens the door to new physic that can be assessed with small detectors placed close to the core. Here we review the Nucifer detector in this context and the tests we are performing. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparison of collimator geometries for imaging mixed radiation fields with fast liquid organic scintillators

As a result of recent advances in digital pulse-shape discrimination methods it has become possible to image mixed fields (radiation environments compromising both neutrons and gamma rays) relatively quickly with a single, organic liquid 'fast' scintillator within a heavy metal collimator. The use of a liquid scintillator has significant benefits over other techniques for imaging radiation environments as the acquired data can be analysed to provide separate information about the gamma and neutron emissions from a source (or sources) in a single scan. The imaging resolution achieved is fundamentally related to the detector efficiency and to the collimator geometry. In this paper the impact of using two different geometries of tungsten collimator are compared experimentally and three different materials considered in the Monte Carlo simulation, in order to determine the optimum set-up for mixed-field imaging. The measurements were performed in the low-scatter facility of the National Physical Laboratory, Teddington. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopy identification performance enhancement of a novel CZT/CsI hybrid system

New hybrid spectroscopic systems directly combine spectra from detectors with very different energy resolutions, accommodating standard analyses of the output hybrid spectrum. Simulations of a hybrid system consisting of a 2 or 4 cm{sup 3} cadmium zinc telluride detector combined with a 32.8 cm{sup 3} CsI(Tl) were evaluated for identification performance. 29 nuclides of interest for security applications were simulated as singles and unique pairs, producing 435 spectral simulations at live times of 3, 10, 30, 100 and 300 seconds. The nuclides were modeled as point sources at 25 cm with activities that provide an interesting range of statistical significance for the range of counting times. Standard nuclide identification analyses were applied to the component detectors as well as the hybrid combination. Tallies of the results were used to calculate true and false identification rates. The hybrid system was shown to provide an identification performance benefit, consistently achieving performances closest to ideal relative to the separate component detectors. The hybrid approach enables the consideration of a greater variety of measurement system solutions in terms of cost and performance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital approach to high rate gamma-ray spectrometry

Basic concepts and preliminary results of creating high rate digital spectrometry system using efficient ADCs and latest FPGA are presented as well as a comparison with commercially available devices. The possibility to use such systems, coupled to scintillators, in plasma experiments is discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterising Encapsulated Nuclear Waste using Cosmic-ray Muon Tomography (MT)

A prototype scintillating-fibre detector system has been developed at the University of Glasgow in collaboration with the UK National Nuclear Laboratory (NNL) for the nondestructive assay of UK legacy nuclear waste containers. This system consists of four tracking modules, two above and two below the container under interrogation. Each module consists of two orthogonal planes of 2 mm-pitch fibres yielding one space point. Per plane, 128 fibres are read out by a single Hamamatsu H8500 64-channel MAPMT with two fibres multiplexed onto each pixel. The configuration allows the reconstruction of the incoming and scattered muon trajectories, thus enabling the container content, with respect to atomic number Z, to be determined. Results are shown from experimental data collected for high-Z objects within an air matrix and within a shielded, concrete-filled container. These reconstructed images show clear discrimination between the low, medium and high-Z materials present, with dimensions and positions determined with sub-centimetre precision. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Generic Isotope Identification Approach for nuclear instrumentation

Isotope identification is generally done from spectra from high intrinsic resolution such as germanium. A lot of approaches are proposed in the literature. Most of them are not efficient with poor energy resolution detectors such as non-loaded scintillators. The proposed approach is a new isotope identification principle to deal with the overall range of nuclear detectors. The proposed method allows the identification of isotopes using detectors with poor intrinsic resolution and lower counting than the existing techniques. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Modeling of Scintillator Thickness for Optimal Light Output and Spatial Resolution

It is common in x-ray radiography to use scintillators (e.g., BGO or LSO) to convert x-rays to visible light, which is then recorded by an imaging system. The response of the scintillator depends fundamentally on its thickness, with respect to both its visible light emittance and its spatial resolution. This is important for optimizing light output, signal to noise ratio, or optical response time. Given that it is often cost-prohibitive to procure a variety of scintillator samples and empirically test the performance, it is essential to be able to model and accurately simulate the performance of a scintillator with respect to thickness and other properties, and a direct way of doing this is using Monte Carlo-based radiation transport codes. Such simulations can be expensive in terms of computational time, and the codes are not easily obtained. In this work we first show such simulations, and demonstrate that there is a natural trade-off between light output of a scintillator and its spatial resolution. We then derive a first-principles model that accurately approximates the light output, using straightforward calculations that can be performed quickly with any basic computing software. We compare the results to those obtained from Monte Carlo simulations and show that our simplified model can be used to analyze the tradeoff between emittance and resolution nearly as well as using a full-scale radiation transport code.

Monte Carlo methods, X-ray imaging, scintillation ↗

Design Rules for Ce-activated scintillating radiation detection materials: Compromises between Luminosity and stopping power

In recent years, the scintillation properties of many specific cerium-doped scintillators (such as LSO and BaBr3) have been extensively studied. This paper presents new development methods for property-screening design rules ,using structure-property relationships for two fundamental target detector properties--luminosity and stopping power. The first and most evident goal in developing screening models of luminosity and stopping power is to obtain new candidate cerium scintillating materials. However, a second and more strategic goal is to extract design rules, which define the structural limitations on materials consistent with desirable detector properties. The design rules are based on our capability to predict the luminescence and stopping power of a material from a set of structural descriptors. These models are generated using statistical multiple linear regression techniques over a large set of 24 descriptors. We find that within a set of ten cerium-doped scintillator materials that we can quantitatively predict luminosity and stopping power with a correlation coefficient of ~0.99 based on 6 of the 24 descriptors. Furthermore, we show that in this circumstance the luminosity and stopping power are nominally related and only share one common descriptor in the developed models. In particular luminosity depends largely on matrix valence electron properties and their coupling to activator sites—properties that do not require high atomic masses per se, a requirement for high stopping power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Global Analysis of Light and Charge Yields in Liquid Xenon

Here, we present an updated model of light and charge yields from nuclear recoils in liquid xenon with a simultaneously constrained parameter set. A global analysis is performed using measurements of electron and photon yields compiled from all available historical data, as well as measurements of the ratio of the two. These data sweep over energies from keV and external applied electric fields from V/cm. The model is constrained by constructing global cost functions and using a simulated annealing algorithm and a Markov Chain Monte Carlo approach to optimize and find confidence intervals on all free parameters in the model. This analysis contrasts with previous work in that we do not unnecessarily exclude datasets nor impose artificially conservative assumptions, do not use spline functions, and reduce the number of parameters used in NEST v 0.98. Here, we report our results and the calculated best-fit charge and light yields. These quantities are crucial to understanding the response of liquid xenon detectors in the energy regime important for rare event searches such as the direct detection of dark matter particles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Physical characteristics of GE Senographe Essential and DS digital mammography detectors

The purpose of this study was to investigate physical characteristics of two full field digital mammography (FFDM) systems (GE Senographe Essential and DS). Both are indirect conversion (x ray to light) a-Si flat panels coupled with a CsI(Tl) scintillator. The examined systems have the same pixel size (100 {mu}m) but a different field of view: a conventional size 23x19.2 cm{sup 2} and a large field 24x30.7 cm{sup 2}, specifically designed to image large breasts. In the GE Senographe Essential model relevant improvements in flat panel design were implemented and new deposition tools for metal, a-Si, and CsI(Tl) were introduced by GE. These changes in detector design are expected to be beneficial for advanced applications such as breast tomosynthesis. The presampling modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) were measured for a wide range of exposure (25-240 {mu}Gy) with a RQA-M2 technique (28 kVp with a Mo/Mo target/filter combination and 2 mm of additional aluminum filtration). At 1, 2, and at 4 lp/mm MTF is equal to 0.9, 0.76, and 0.46 for the conventional field detector and to 0.85, 0.59, and 0.24 for the large field detector. The latter detector exhibits an improved NNPS due to a lower electronic noise and a better DQE that reaches 60%. In addition a contrast-detail analysis was performed with CDMAM 3.4 phantom and CDCOM software: GE Senographe DS showed statistically significant poorer detection ability in comparison with the GE Senographe Essential. These results could have been expected, at least qualitatively, considering the relative DQE of the two systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray imaging performance of scintillator-filled silicon pore arrays

The need for fine detail visibility in various applications such as dental imaging, mammography, but also neurology and cardiology, is the driver for intensive efforts in the development of new x-ray detectors. The spatial resolution of current scintillator layers is limited by optical diffusion. This limitation can be overcome by a pixelation, which prevents optical photons from crossing the interface between two neighboring pixels. In this work, an array of pores was etched in a silicon wafer with a pixel pitch of 50 {mu}m. A very high aspect ratio was achieved with wall thicknesses of 4-7 {mu}m and pore depths of about 400 {mu}m. Subsequently, the pores were filled with Tl-doped cesium iodide (CsI:Tl) as a scintillator in a special process, which includes powder melting and solidification of the CsI. From the sample geometry and x-ray absorption measurement the pore fill grade was determined to be 75%. The scintillator-filled samples have a circular active area of 16 mm diameter. They are coupled with an optical sensor binned to the same pixel pitch in order to measure the x-ray imaging performance. The x-ray sensitivity, i.e., the light output per absorbed x-ray dose, is found to be only 2.5%-4.5% of a commercial CsI-layer of similar thickness, thus very low. The efficiency of the pores to transport the generated light to the photodiode is estimated to be in the best case 6.5%. The modulation transfer function is 40% at 4 lp/mm and 10%-20% at 8 lp/mm. It is limited most likely by the optical gap between scintillator and sensor and by K-escape quanta. The detective quantum efficiency (DQE) is determined at different beam qualities and dose settings. The maximum DQE(0) is 0.28, while the x-ray absorption with the given thickness and fill factor is 0.57. High Swank noise is suspected to be the reason, mainly caused by optical scatter inside the CsI-filled pores. The results are compared to Monte Carlo simulations of the photon transport inside the pore array structure. In addition, some x-ray images of technical and anatomical phantoms are shown. This work shows that scintillator-filled pore arrays can provide x-ray imaging with high spatial resolution, but are not suitable in their current state for most of the applications in medical imaging, where increasing the x-ray doses cannot be tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) for low dose x-ray imaging: Spatial resolution

An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-Se) avalanche photoconductor called high-gain avalanche rushing amorphous photoconductor (HARP). The charge image created by the scintillator/HARP (SHARP) combination is read out by the electron beams emitted from the FEA. The proposed detector is called scintillator avalanche photoconductor with high resolution emitter readout (SAPHIRE). The programmable avalanche gain of HARP can improve the low dose performance of indirect FPI while the FEA can be made with pixel sizes down to 50 {mu}m. Because of the avalanche gain, a high resolution type of CsI (Tl), which has not been widely used in indirect FPI due to its lower light output, can be used to improve the high spatial frequency performance. The purpose of the present article is to investigate the factors affecting the spatial resolution of SAPHIRE. Since the resolution performance of the SHARP combination has been well studied, the focus of the present work is on the inherent resolution of the FEA readout method. The lateral spread of the electron beam emitted from a 50 {mu}mx50 {mu}m pixel FEA was investigated with two different electron-optical designs: mesh-electrode-only and electrostatic focusing. Our results showed that electrostatic focusing can limit the lateral spread of electron beams to within the pixel size of down to 50 {mu}m. Since electrostatic focusing is essentially independent of signal intensity, it will provide excellent spatial uniformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(Tl) full-field flat panel detector

The purpose of this study is to evaluate the performance of an antiscatter grid and its potential benefit on image quality for a full-field digital mammography (FFDM) detector geometry at energies typical for temporal subtraction contrast-enhanced (CE) breast imaging. The signal intensities from primary, scatter, and glare were quantified in images acquired with an a-Si/CsI(Tl) FFDM detector using a Rh target and a 0.27 mm Cu filter at tube voltages ranging from 35 to 49 kV. Measurements were obtained at the center of the irradiation region of 20-80 mm thick breast-equivalent phantoms. The phantoms were imaged with and without an antiscatter grid. Based on these data, the performance of the antiscatter grid was determined by calculating the primary and scatter transmission factors (T{sub P} and T{sub S}) and Bucky factors (B{sub f}). In addition, glare-to-primary ratios (GPRs) and scatter-to-primary ratios (SPRs) were quantified. The effect of the antiscatter grid on the signal-difference-to-noise ratio (SDNR) was also assessed. It was found that T{sub P} increases with kV but does not depend on the phantom thickness; T{sub P} values between 0.81 and 0.84 were measured. T{sub S} increases with kV and phantom thickness; T{sub S} values between 0.13 and 0.21 were measured. B{sub f} decreases with kV and increases with phantom thickness; B{sub f} ranges from 1.4 to 2.1. GPR is nearly constant, varying from 0.10 to 0.11. SPR without an antiscatter grid (SPR{sup -}) ranges from 0.35 to 1.34. SPR{sup -} decreases by approximately 9% from 35 to 49 kV for a given phantom thickness and is 3.5 times larger for an 80 mm thick breast-equivalent phantom than for a 20 mm thick breast-equivalent phantom. SPR with an antiscatter grid (SPR{sup +}) ranges from 0.06 to 0.31. SPR{sup +} increases by approximately 23% from 35 to 49 kV for a given phantom thickness; SPR{sup +} is four times larger for an 80 mm breast-equivalent phantom than for a 20 mm breast-equivalent phantom. When imaging a 25 mm PMMA plate at the same mean glandular dose with and without an antiscatter grid, the SDNR is 4% greater with a grid than without. For an 75mm PMMA plate, the SDNR is 20% greater with a grid. In conclusion, at the higher x-ray energy range used for CE-DM and CE-DBT, an antiscatter grid significantly reduces SPR and improves SDNR. These effects are most pronounced for thick breasts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a water-equivalent fiber-optic coupled dosimeter for use in diagnostic radiology

This work reports on the characterization of a new fiber-optic coupled (FOC) dosimeter for use in the diagnostic radiology energy range. The FOC dosimeter was constructed by coupling a small cylindrical plastic scintillator, 500 {mu}m in diameter and 2 mm in length, to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube (PMT). A serial port interface on the PMT permits real-time monitoring of light output from the dosimeter via a custom computer program. The FOC dosimeter offered excellent sensitivity and reproducibility, allowing doses as low as 0.16 mGy to be measured with a coefficient of variation of only 3.64%. Dose linearity was also excellent with a correlation coefficient of 1.000 over exposures ranging from 0.16 to 57.29 mGy. The FOC dosimeter exhibited little angular dependence from axial irradiation, varying by less than 5% over an entire revolution. A positive energy dependence was observed and measurements performed within a scatter medium yielded a 10% variation in sensitivity as beam quality changed due to hardening and scatter across a 16 cm depth range. The current dosimetry system features an array of five PMTs to allow multiple FOC dosimeters to be monitored simultaneously. Overall, the system allows for rapid and accurate dose measurements relevant to a range of diagnostic imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗