Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A Cloud-Tracking Data Set for the CSAPR2 Adaptive Scanning during TRACER

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility (Mather and Voyles 2013) deployed the first ARM Mobile Facility (AMF1; Miller et al. 2016) near LaPorte, Texas to support the Tracking Aerosol Convection Interactions Experiment (TRACER) (Jensen et al. 2025) near Houston, Texas. From October 2021 to September 2022, AMF1 was deployed to 29.67° N, 95.06° W near LaPorte, Texas and the 2nd Generation C-band Scanning ARM Precipitation Radar (CSAPR2) was deployed to a supplementary site at 29.53° N, 95.28° W (Figure 1). During an intensive operational period (IOP) from 1 June to 30 September 2022, the CSAPR2 sampled precipitation echoes in an adaptive scanning mode following the Multisensor Agile Adaptive Scanning (MAAS) framework (Kollias et al. 2020). MAAS helped optimize the CSAPR2 scan strategy to perform frequent plan position indicator (PPI) and range height indicator (RHI) scans (Lamer et al. 2023). Details of the CSAPR2 scanning, data processing, and calibration procedures used by the principal investigator (PI), and the PI data files are described by Oue et al. (2023). Details of the CSAPR2 operational performance, ARM data processing and correction procedures, and data quality masks are described by Feng et al. (2024a).

54 ENVIRONMENTAL SCIENCES↗

FAST (FAST AUTONOMOUS SCANNING TOOLKIT)

SF-23-006 FAST (FAST AUTONOMOUS SCANNING TOOLKIT)The software is deployed on an edge computing device at the beamline computer attached to a scanning microscope. It iteratively analyzes the data collected, then identifies new scan positions to scan next and directs the positioners that move the sample (or probe beam) to these positions. Overall, it identifies a sparse set of scan positions that are sufficient to image the full sample. This can reduce the scan time by >60%.

KANDEL, SAUGAT↗

Scanning system tradeoffs for remote optical sensing from geosynchronous orbit

The scanning and telescope field of view requirements for making Earth Resources (ER) and Meteorological (MET) phenomena observations from a Synchronous Earth Observation Satellite (SEOS) have been defined. The equations relating spacecraft scan capability to user scan field of view requirements are given and evaluated using four different telescope fields of view. The tradeoffs between telescope field-of-view and user scan fields of view requirements are shown, and it was determined that a 0.6 degree by 1.2 degree telescope FOV is optimum for the SEOS telescope. It was shown that an internal scan as well as external scan is required to satisfy both ER and MET users.

Young, P. J.↗

Rotating-unbalanced-mass Devices for Scanning Balloon-borne Experiments, Free-flying Spacecraft, and Space Shuttle/space Station Experiments

A new method is presented for scanning balloon-borne experiments, free-flying spacecraft, and gimballed experiments mounted to the space shuttle or the space station. It uses rotating-unbalanced-mass (RUM) devices for generating circular, line, or raster scan patterns and an auxiliary control system for target acquisition, keeping the scan centered on the target, and producing complementary motion for raster scanning. It is ideal for applications where the only possible way to accomplish the required scan is to physically scan the entire experiment or spacecraft as in x ray and gamma ray experiments. In such cases, this new method should have advantages over prior methods in terms of either power, weight, cost, performance, stability, or a combination of these.

Polites, Michael E.↗

New method for scanning spacecraft and balloon-borne/space-based experiments

A new method is presented for scanning balloon-borne experiments, free-flying spacecraft, and gimballed experiments mounted to the space shuttle or the space station. It uses rotating-unbalanced-mass (RUM) devices for generating circular, line, or raster scan patterns and an auxiliary control system for target acquisition, keeping the scan centered on the target, and producing complementary motion for raster scanning. It is ideal for applications where the only possible way to accomplish the required scan is to physically scan the entire experiment or spacecraft as in X-ray and gamma ray experiments. In such cases, this new method should have advantages over prior methods in terms of either power, weight, cost, performance, stability, or a combination of these.

Polites, Michael E.↗

Rotating Unbalanced-Mass Devices for Scanning: Proof-of-Concept Test Results

This experiment proves the concept of line-of-sight scanning space-based and balloon-borne instruments and telescopes with rotating unbalanced-mss (RUM) devices. Extending the concept to free-flying spacecraft is straightforward. When line-of-sight scanning is required, but optical or electronic line-of-sight scanning is impossible, then scanning with RUM devices can offer huge power and mass savings, better system reliability and stability, and improved scan accuracy. This is especially true with large instruments and telescopes scanning at high frequencies.

Alhorn, Dean C.↗

New Research by CCD Scanning for Comets and Asteroids

Spacewatch was begun in 1980; its purpose is to explore the various populations of small objects within the solar system. Spacewatch provides data for studies of comets and asteroids, finds potential targets for space missions, and provides information on the environmental problem of possible impacts. Moving objects are discovered by scanning the sky with charge-coupled devices (CCDS) on the 0.9-meter Spacewatch Telescope of the University of Arizona on Kitt Peak. Each Spacewatch scan consists of three drift scan passes over an area of sky using a CCD filtered to a bandpass of 0.5-1.0 pm (approximately V+R+I with peak sensitivity at 0.7 pm). The effective exposure time for each pass is 143 seconds multiplied by the secant of the declination. The area covered by each scan is 32 arcminutes in declination by about 28 minutes of time in right ascension. The image scale is 1.05 arcseconds per pixel. Three passes take about 1.5 hours to complete and show motions of individual objects over a one hour time baseline. The limiting magnitude is about 21.5 in single scans. CCD scanning was developed by Spacewatch in the early 1980s, with improvements still being made - particularly by bringing a new 1.8-m Spacewatch Telescope on line. In the meantime, we have been finding some 30,000 new asteroids per year and applying their statistics to the study of the collisional history of the solar system. Spacewatch had found a total of 150 Near-Earth Asteroids (NEAS) and 8 new comets, and had recovered one lost comet (P/Spitaler in 1993). Spacewatch is also efficient in recovery of known comets and has detected and reported positions for more than 137,000 asteroids, mostly new ones in the main belt, including more than 10,882 asteroids designated by the Minor Planet Center (MPC).

Gehrels, Tom↗

Pointing and Scanning Control of Instruments Using Rotating Unbalanced Masses

Motions of telescopes, satellites, and other flight bodies have been controlled by various means in the past. For example, gimbal mounted devices can use electric motors to produce pointing and scanning motions. Reaction wheels, control moment gyros, and propellant-charged reaction jets are other technologies that have also been used. Each of these methods has its advantages, but all actuator systems used in a flight environment face the challenges of minimizing weight, reducing energy consumption, and maximizing reliability. Recently, Polites invented and patented the Rotating Unbalanced Mass (RUM) device as a means for generation scanning motion on flight experiments. RUM devices have been successfully used to generate various scanning motions. The basic principle: a RUM rotating at constant annular velocity exerts a cyclic centrifugal force on the instrument or main body, thus producing a periodic scanning motion. A system of RUM devices exerts no reaction forces on the main body, requires very little energy, and is very simple to construct and control. These are significant advantages over electric motors, reaction wheels, and control moment gyroscopes. Although the RUM device very easily produces scanning motion, an auxiliary control system may be required to maintain the proper orientation, or pointing of the main body. It has been suggested that RUM devices can be used to control pointing dynamics, as well as generate the desired periodic scanning motion. The idea is that the RUM velocity will not be constant, but will vary over the period of one RUM rotation. The thought is that the changing angular velocity produces a centrifugal force having time-varying magnitude and direction. The scope of the present research project is to further study the pointing control concept, and to implement a microcontroller program to control an experimental hardware system. This report is subdivided into three themes. The basic dynamic modeling and control principles are described first. Then, the controller implementation and preliminary test results are discussed. Finally, suggestions for future work are presented.

Hung, John Y.↗

On Orbit Measurement of Response vs. Scan Angle for the Infrared Bands on TRMM/VIRS

The Visible and Infrared Scanner on the Tropical Rainfall Measuring Mission (TRMM/VIRS) is a whiskbroom imaging radiometer with two reflected solar bands and three emissive infrared bands. All five detectors are on a single cooled focal plane. This configuration necessitated the use of a paddlewheel scan mirror to avoid the effects of focal plane rotation that arise when using a scan mirror that is inclined to its axis of rotation. System radiometric requirements led to the need for protected silver as the mirror surface. Unfortunately, the SiO(x) coatings currently used to protect silver from oxidation introduce a change in reflectance with angle of incidence (AOI). This AOI dependence results in a modulation of system level response with scan angle. Measurement of system response vs. scan angle (RVS) was not difficult for the VIRS reflected solar bands, but attaining the required accuracy for the IR bands in the laboratory was not possible without a large vacuum chamber and a considerable amount of custom designed testing apparatus. Therefore, the decision was made to conduct the measurement on-orbit. On three separate occasions, the TRMM spacecraft was rotated about its pitch axis and, after the nadir view passed over the Earth's limb, the VIRS performed several thousand scans while viewing deep space. The resulting data has been analyzed and the RVS curves generated for the three IR bands are being used in the VIRS radiometric calibration algorithm. This, to our knowledge, the first time this measurement has been made on-orbit. Similar measurements are planned for the EOS-AM and EOS-PM MODIS sensors and are being considered for several systems under development. The VIRS on-orbit results will be compared to VIRS and MODIS system level laboratory measurements, MODIS scan mirror witness sample measurements and modeled data.

Barnes, William L.↗

Wide scanning spherical antenna

A novel method for calculating the surface shapes for subreflectors in a suboptic assembly of a tri-reflector spherical antenna system is introduced, modeled from a generalization of Galindo-Israel's method of solving partial differential equations to correct for spherical aberration and provide uniform feed to aperture mapping. In a first embodiment, the suboptic assembly moves as a single unit to achieve scan while the main reflector remains stationary. A feed horn is tilted during scan to maintain the illuminated area on the main spherical reflector fixed throughout the scan thereby eliminating the need to oversize the main spherical reflector. In an alternate embodiment, both the main spherical reflector and the suboptic assembly are fixed. A flat mirror is used to create a virtual image of the suboptic assembly. Scan is achieved by rotating the mirror about the spherical center of the main reflector. The feed horn is tilted during scan to maintain the illuminated area on the main spherical reflector fixed throughout the scan.

Shen, Bing↗

Dual-Frequency Airborne Scanning Rain Radar Antenna System

A compact, dual-frequency, dual-polarization, wide-angle-scanning antenna system has been developed as part of an airborne instrument for measuring rainfall. This system is an upgraded version of a prior single-frequency airborne rain radar antenna system and was designed to satisfy stringent requirements. One particularly stringent combination of requirements is to generate two dual-polarization (horizontal and vertical polarizations) beams at both frequencies (13.405 and 35.605 GHz) in such a way that the beams radiated from the antenna point in the same direction, have 3-dB angular widths that match within 25 percent, and have low sidelobe levels over a wide scan angle at each polarization-and-frequency combination. In addition, the system is required to exhibit low voltage standing-wave ratios at both frequencies. The system (see figure) includes a flat elliptical scanning reflector and a stationary offset paraboloidal reflector illuminated by a common-aperture feed system that comprises a corrugated horn with four input ports one port for each of the four frequency-and-polarization combinations. The feed horn is designed to simultaneously (1) under-illuminate the reflectors 35.605 GHz and (2) illuminate the reflectors with a 15-dB edge taper at 13.405 GHz. The scanning mirror is rotated in azimuth to scan the antenna beam over an angular range of 20 in the cross-track direction for wide swath coverage, and in elevation to compensate for the motion of the aircraft. The design of common-aperture feed horn makes it possible to obtain the required absolute gain and low side-lobe levels in wide-angle beam scanning. The combination of the common-aperture feed horn with the small (0.3) focal-length-to-diameter ratio of the paraboloidal reflector makes it possible for the overall system to be compact enough that it can be mounted on a DC-8 airplane.

Hussein, Ziad A.↗

In-Orbit Performance of the MWRI Scanning Mechanisms

Scanning Equipment supporting the Millimeter Wave Radiometer Instrument (MWRI) are flying in a sunsynchronized orbit of 850-km altitude with an inclination of 98.8 deg on the FY-3 meteorological satellite (FY = Feng Yun, Wind and Cloud). MWRI is a linearly polarized, ten-channel passive Radiometer; it measures precipitation and water clouds, sea ice, snow/water equivalent, drought and flood index, land temperature and soil moisture. Following the FY3-A, the FY3-B Satellite was launched in autumn 2010. Since that time, the Scanning Equipment was continuously operated. During the last three and a half years in orbit, the Scanning Mechanism has executed about 65 million revolutions, while the Scan Compensation Mechanism (SCM) - used for momentum compensation - has already successfully executed more than one billion revolutions. During the commissioning phase of the instrument and during the first operation phase, random torque spikes, which manifested themselves as a motor current increase, were observed in the Scan Drive Mechanism, whereas the Scan Compensation drive operated nominally from the beginning. The result of the root cause investigations performed in order to isolate the issue, and the consequences for the follow-on MWRI equipment which was successfully launched by end of September 2013 (now flying on the FY 3-C Spacecraft), are discussed.

Schmid, Manfred↗

Tracking On-Orbit Stability of the Response Versus Scan Angle for the S-NPP VIIRS Reflective Solar Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi NPP (National Polar-orbiting Partnership) satellite (http:npp.gsfc.nasa.govviirs.html) has been in operation for nearly five years. The onboard calibration of the VIIRS reflective solar bands (RSB) relies on a solar diffuser (SD) located at a fixed scan angle and a solar diffuser stability monitor (SDSM). The VIIRS response versus scan angle (RVS) was characterized prelaunch in ambient conditions and is currently used to determine the on-orbit response for all scan angles relative to the SD scan angle. Since the RVS is vitally important to the quality of calibrated level 1B products, it is important to monitor its on-orbit stability. In this study, the RVS stability is examined based on reflectance trends collected from 16-day repeatable orbits over pre-selected pseudo-invariant desert sites in Northern Africa. These trends nearly cover the entire Earth view scan range so that any systematic drifts in the scan angle direction would indicate a change in RVS. This study also compares VIIRS RVS on-orbit stability results with those from both Aqua and Terra MODIS over the first four years of mission for a few selected bands, which provides further information on potential VIIRS RVS on-orbit changes.

Wu, Aisheng↗

Determination of Response Versus Scan Angle for the NOAA-20 Visible Infrared Imaging Radiometer Suite Thermal Emissive Bands from Emissive Radiation Measurements During the Pitch Maneuver

The visible infrared imaging radiometer suite (VIIRS) is a key sensor onboard the newly launched (November 18, 2017) NOAA-20 satellite and the early launched Suomi National Polar-orbiting Partnership (SNPP) satellite. The two VIIRS sensors are nearly identical in design. Its onboard calibration components include a solar diffuser (SD) and a SD stability monitor for the reflective solar bands, a V-grooved blackbody for the thermal emissive bands (TEBs),and a space view port for background subtraction. These onboard calibrators are located at fixed scan angles. The response versus scan angle (RVS) of the VIIRS scan mirror was characterized prelaunch in lab-ambient conditions and is currently used to calibrate the on-orbit response for all scan angles relative to the calibrator's scan angle. A spacecraft-level pitch maneuver was scheduled during the initial intensive calibration and validation testing for both the NOAA-20 and SNPP. The pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of the scan angle, which can be used to characterize the TEBRVS. We analyze the NOAA-20 pitch maneuver data and assess the derived TEB RVS. A comparison between the RVS determined by the pitch maneuver observations and prelaunch lab measurements is conducted for each band, detector, and mirror side of the half-angle mirror.

Wu, Aisheng↗

Application Software Cybersecurity Scanning

Scanning software applications for cybersecurity vulnerabilities is a crucial step is assessing the overall health of the application, but how can this kind of scan be performed to give development teams the information they need to make informed design decisions? Two pilot cybersecurity scans were conducted in an attempt to answer this question. A scanning team composed of various subject matter experts was established and worked closely with the development team to perform these scans and capture metrics throughout the process. These interactions and metrics indicate that these scans can be performed in an unobtrusive way and still provide valuable information to development teams regarding the health of their application. This work is not definitive in nature but serves as a foundation for future work.

Barner, Lyle↗

System and method for compressive scanning electron microscopy

A scanning transmission electron microscopy (STEM) system is disclosed. The system may make use of an electron beam scanning system configured to generate a plurality of electron beam scans over substantially an entire sample, with each scan varying in electron-illumination intensity over a course of the scan. A signal acquisition system may be used for obtaining at least one of an image, a diffraction pattern, or a spectrum from the scans, the image, diffraction pattern, or spectrum representing only information from at least one of a select subplurality or linear combination of all pixel locations comprising the image. A dataset may be produced from the information. A subsystem may be used for mathematically analyzing the dataset to predict actual information that would have been produced by each pixel location of the image.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-scan computed tomography defect detectability

Systems and methods for representing internal defects of an object to determine defect detectability using a multi-scan computed tomography (CT) approach are disclosed. A defect-free object may be scanned using a CT machine. In one or more separate scans, phantom defects may be imaged and the resulting projections combined and reconstructed to represent internal defects. The air-normalized intensities of the object and the phantom defect may be used to represent voids and inclusions. Subtraction of materials may be represented by the quotient of the air-normalized intensities thereof, and the addition of materials may be represented by the product of the air-normalized intensities thereof. A void may be represented by subtracting a phantom defect scan from the object scan. An inclusion may be represented by creating a void, scanning an additional phantom defect, and adding the additional phantom defect in the volume created by the void.

Schiefelbein, Bryan E.↗

Selective Nodal Irradiation on Basis of {sup 18}FDG-PET Scans in Limited-Disease Small-Cell Lung Cancer: A Prospective Study

Purpose: To evaluate the results of selective nodal irradiation on basis of {sup 18}F-deoxyglucose positron emission tomography (PET) scans in patients with limited-disease small-cell lung cancer (LD-SCLC) on isolated nodal failure. Methods and Materials: A prospective study was performed of 60 patients with LD-SCLC. Radiotherapy was given to a dose of 45 Gy in twice-daily fractions of 1.5 Gy, concurrent with carboplatin and etoposide chemotherapy. Only the primary tumor and the mediastinal lymph nodes involved on the pretreatment PET scan were irradiated. A chest computed tomography (CT) scan was performed 3 months after radiotherapy completion and every 6 months thereafter. Results: A difference was seen in the involved nodal stations between the pretreatment {sup 18}F-deoxyglucose PET scans and computed tomography scans in 30% of patients (95% confidence interval, 20-43%). Of the 60 patients, 39 (65%; 95% confidence interval [CI], 52-76%) developed a recurrence; 2 patients (3%, 95% CI, 1-11%) experienced isolated regional failure. The median actuarial overall survival was 19 months (95% CI, 17-21). The median actuarial progression-free survival was 14 months (95% CI, 12-16). 12% (95% CI, 6-22%) of patients experienced acute Grade 3 (Common Terminology Criteria for Adverse Events, version 3.0) esophagitis. Conclusion: PET-based selective nodal irradiation for LD-SCLC resulted in a low rate of isolated nodal failures (3%), with a low percentage of acute esophagitis. These findings are in contrast to those from our prospective study of CT-based selective nodal irradiation, which resulted in an unexpectedly high percentage of isolated nodal failures (11%). Because of the low rate of isolated nodal failures and toxicity, we believe that our data support the use of PET-based SNI for LD-SCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗