Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “S Parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Development and application of marginal likelihood optimization for integral parameter adjustment

When adjusting nuclear data with integral experiments, care must be taken that spurious adjustments are not made by assimilating poorly characterized integral parameters. If there are unaccounted for biases or poorly estimated uncertainties in the calculated and experimental values for an integral parameter, the Bayesian data assimilation may adjust the nuclear data in a manner that does not reflect the physics of the integral parameter. To identify and lessen the impact of these inconsistent integral parameters, in this study we present a Marginal Likelihood Optimization algorithm. In a data-driven way, the marginalized likelihood is used to modulate hyperparameter terms that decrease the influence of inconsistent integral parameters on the adjustment. The advantage of this approach over other methods in the literature is that it incorporates correlation information and does not remove an integral parameter from the adjustment. Herein, we present and motivate the algorithm, and apply it to an integral data assimilation case study.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generation of localized reactor point kinetics parameters using coupled neutronic and thermal fluid models for pebble-bed reactor transient analysis

The systems analysis of anticipated operating occurrences and design basis accidents for pebble-bed reactor systems requires knowledge of neutron point kinetics equations (PKE) parameters. Typically, the generation of PKE parameters is performed in a global manner using standalone neutronics calculations, without the inclusion of thermal fluid distributions. We utilize Griffin and Pronghorn for generating global and local PKE parameters which includes the use of thermal fluid distributions to account for localized effects. This work establishes a methodology for calculating PKE parameters for a pebble bed reactor with a coupled neutronics/thermal fluids analysis. PKE parameters generated on a global and local basis are compared against a diffusion solve for a typical load-following transient. Locally-generated neutron kinetic parameters are able to reduce the maximum error in the transient power level from 5% to below 1.5%; along with this, bulk temperature errors were reduced from 12 K to 4 K.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bayesian methods for parameter estimation in effective field theories

We demonstrate and explicate Bayesian methods for fitting the parameters that encode the impact of short-distance physics on observables in effective field theories (EFTs). We use Bayes' theorem together with the principle of maximum entropy to account for the prior information that these parameters should be natural, i.e., O(1) in appropriate units. Marginalization can then be employed to integrate the resulting probability density function (pdf) over the EFT parameters that are not of specific interest in the fit. We also explore marginalization over the order of the EFT calculation, M, and over the variable, R, that encodes the inherent ambiguity in the notion that these parameters are O(1). This results in a very general formula for the pdf of the EFT parameters of interest given a data set, D. We use this formula and the simpler 'augmented {chi}{sup 2}' in a toy problem for which we generate pseudo-data. These Bayesian methods, when used in combination with the 'naturalness prior', facilitate reliable extractions of EFT parameters in cases where {chi}{sup 2} methods are ambiguous at best. We also examine the problem of extracting the nucleon mass in the chiral limit, M{sub 0}, and the nucleon sigma term, from pseudo-data on the nucleon mass as a function of the pion mass. We find that Bayesian techniques can provide reliable information on M{sub 0}, even if some of the data points used for the extraction lie outside the region of applicability of the EFT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CXTFIT/Excel A modular adaptable code for parameter estimation, sensitivity analysis and uncertainty analysis for laboratory or field tracer experiments

We implemented the widely used CXTFIT code in Excel to provide flexibility and added sensitivity and uncertainty analysis functions to improve transport parameter estimation and to facilitate model discrimination for multi-tracer experiments on structured soils. Analytical solutions for one-dimensional equilibrium and nonequilibrium convection dispersion equations were coded as VBA functions so that they could be used as ordinary math functions in Excel for forward predictions. Macros with user-friendly interfaces were developed for optimization, sensitivity analysis, uncertainty analysis, error propagation, response surface calculation, and Monte Carlo analysis. As a result, any parameter with transformations (e.g., dimensionless, log-transformed, species-dependent reactions, etc.) could be estimated with uncertainty and sensitivity quantification for multiple tracer data at multiple locations and times. Prior information and observation errors could be incorporated into the weighted nonlinear least squares method with a penalty function. Users are able to change selected parameter values and view the results via embedded graphics, resulting in a flexible tool applicable to modeling transport processes and to teaching students about parameter estimation. The code was verified by comparing to a number of benchmarks with CXTFIT 2.0. It was applied to improve parameter estimation for four typical tracer experiment data sets in the literature using multi-model evaluation and comparison. Additional examples were included to illustrate the flexibilities and advantages of CXTFIT/Excel. The VBA macros were designed for general purpose and could be used for any parameter estimation/model calibration when the forward solution is implemented in Excel. A step-by-step tutorial, example Excel files and the code are provided as supplemental material.

54 ENVIRONMENTAL SCIENCES↗

Order parameter re-mapping algorithm for 3D phase field model of grain growth using FEM

Phase field modeling (PFM) is a well-known technique for simulating microstructural evolution. To model grain growth using PFM, typically each grain is assigned a unique non-conserved order parameter and each order parameter field is evolved in time. Traditional approaches using a one-to-one mapping of grains to order parameters present a challenge when modeling large numbers of grains due to the computational expense of using many order parameters. This problem is exacerbated when using an implicit finite element method (FEM), as the global matrix size is proportional to the number of order parameters. While previous work has developed methods to reduce the number of required variables and thus computational complexity and run time, none of the existing approaches can be applied for an implicit FEM implementation of PFM. Here, we present a modular, dynamic, scalable reassignment algorithm suitable for use in such a system. Polycrystal modeling with grain growth and stress require careful tracking of each grain’s position and orientation which is lost when using a reduced order parameter set. In conclusion, the method presented in this paper maintains a unique ID for each grain even after reassignment, to allow the PFM to be tightly coupled to calculations of the stress throughout the polycrystal. Implementation details and comparative results of our approach are presented.

36 MATERIALS SCIENCE↗

Application of an Evolutionary Algorithm for Parameter Optimization in a Gully Erosion Model

Herein we demonstrate how to use model optimization to determine a set of best-fit parameters for a landform model simulating gully incision and headcut retreat. To achieve this result we employed the Covariance Matrix Adaptation Evolution Strategy (CMA-ES), an iterative process in which samples are created based on a distribution of parameter values that evolve over time to better fit an objective function. CMA-ES efficiently finds optimal parameters, even with high-dimensional objective functions that are non-convex, multimodal, and non-separable. We ran model instances in parallel on a high-performance cluster, and from hundreds of model runs we obtained the best parameter choices. This method is far superior to brute-force search algorithms, and has great potential for many applications in earth science modeling. We found that parameters representing boundary conditions tended to converge toward an optimal single value, whereas parameters controlling geomorphic processes are defined by a range of optimal values.

97 MATHEMATICS AND COMPUTING↗

Dose-Volume Histogram Parameters and Late Side Effects in Magnetic Resonance Image-Guided Adaptive Cervical Cancer Brachytherapy

Purpose: To evaluate the predictive value of dose-volume histogram (DVH) parameters for late side effects of the rectum, sigmoid colon, and bladder in image-guided brachytherapy for cervix cancer patients. Methods and Materials: A total of 141 patients received external-beam radiotherapy and image-guided brachytherapy with or without chemotherapy. The DVH parameters for the most exposed 2, 1, and 0.1 cm{sup 3} (D{sub 2cc}, D{sub 1cc}, and D{sub 0.1cc}) of the rectum, sigmoid, and bladder, as well as International Commission on Radiation Units and Measurements point doses (D{sub ICRU}) were computed. Total doses were converted to equivalent doses in 2 Gy by applying the linear-quadratic model ({alpha}/{beta} = 3 Gy). Late side effects were prospectively assessed using the Late Effects in Normal Tissues-Subjective, Objective, Management and Analytic score. The following patient groups were defined: Group 1: no side effects (Grade 0); Group 2: side effects (Grade 1-4); Group 3: minor side effects (Grade 0-1); and Group 4: major side effects (Grade 2-4). Results: The median follow-up was 51 months. The overall 5-year actuarial side effect rates were 12% for rectum, 3% for sigmoid, and 23% for bladder. The mean total D{sub 2cc} were 65 {+-} 12 Gy for rectum, 62 {+-} 12 Gy for sigmoid, and 95 {+-} 22 Gy for bladder. For rectum, statistically significant differences were observed between Groups 1 and 2 in all DVH parameters and D{sub ICRU}. Between Groups 3 and 4, no difference was observed for D{sub 0.1cc.} For sigmoid, significant differences were observed for D{sub 2cc} and D{sub 1cc}, but not for D{sub 0.1cc} in all groups. For bladder, significant differences were observed for all DVH parameters only comparing Groups 3 and 4. No differences were observed for D{sub ICRU}. Conclusions: The parameters D{sub 2cc} and D{sub 1cc} have a good predictive value for rectal toxicity. For sigmoid, no prediction could be postulated because of limited data. In bladder, DVH parameters were predictive only for major toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Contrast-Enhanced MRI of Cervical Cancers: Temporal Percentile Screening of Contrast Enhancement Identifies Parameters for Prediction of Chemoradioresistance

Purpose: To systematically screen the tumor contrast enhancement of locally advanced cervical cancers to assess the prognostic value of two descriptive parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Methods and Materials: This study included a prospectively collected cohort of 81 patients who underwent DCE-MRI with gadopentetate dimeglumine before chemoradiotherapy. The following descriptive DCE-MRI parameters were extracted voxel by voxel and presented as histograms for each time point in the dynamic series: normalized relative signal increase (nRSI) and normalized area under the curve (nAUC). The first to 100th percentiles of the histograms were included in a log-rank survival test, resulting in p value and relative risk maps of all percentile-time intervals for each DCE-MRI parameter. The maps were used to evaluate the robustness of the individual percentile-time pairs and to construct prognostic parameters. Clinical endpoints were locoregional control and progression-free survival. The study was approved by the institutional ethics committee. Results: The p value maps of nRSI and nAUC showed a large continuous region of percentile-time pairs that were significantly associated with locoregional control (p < 0.05). These parameters had prognostic impact independent of tumor stage, volume, and lymph node status on multivariate analysis. Only a small percentile-time interval of nRSI was associated with progression-free survival. Conclusions: The percentile-time screening identified DCE-MRI parameters that predict long-term locoregional control after chemoradiotherapy of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Agreement Between Institutional Measurements and Treatment Planning System Calculations for Basic Dosimetric Parameters as Measured by the Imaging and Radiation Oncology Core-Houston

Purpose: To compare radiation machine measurement data collected by the Imaging and Radiation Oncology Core at Houston (IROC-H) with institutional treatment planning system (TPS) values, to identify parameters with large differences in agreement; the findings will help institutions focus their efforts to improve the accuracy of their TPS models. Methods and Materials: Between 2000 and 2014, IROC-H visited more than 250 institutions and conducted independent measurements of machine dosimetric data points, including percentage depth dose, output factors, off-axis factors, multileaf collimator small fields, and wedge data. We compared these data with the institutional TPS values for the same points by energy, class, and parameter to identify differences and similarities using criteria involving both the medians and standard deviations for Varian linear accelerators. Distributions of differences between machine measurements and institutional TPS values were generated for basic dosimetric parameters. Results: On average, intensity modulated radiation therapy–style and stereotactic body radiation therapy–style output factors and upper physical wedge output factors were the most problematic. Percentage depth dose, jaw output factors, and enhanced dynamic wedge output factors agreed best between the IROC-H measurements and the TPS values. Although small differences were shown between 2 common TPS systems, neither was superior to the other. Parameter agreement was constant over time from 2000 to 2014. Conclusions: Differences in basic dosimetric parameters between machine measurements and TPS values vary widely depending on the parameter, although agreement does not seem to vary by TPS and has not changed over time. Intensity modulated radiation therapy–style output factors, stereotactic body radiation therapy–style output factors, and upper physical wedge output factors had the largest disagreement and should be carefully modeled to ensure accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Test models for improving filtering with model errors through stochastic parameter estimation

The filtering skill for turbulent signals from nature is often limited by model errors created by utilizing an imperfect model for filtering. Updating the parameters in the imperfect model through stochastic parameter estimation is one way to increase filtering skill and model performance. Here a suite of stringent test models for filtering with stochastic parameter estimation is developed based on the Stochastic Parameterization Extended Kalman Filter (SPEKF). These new SPEKF-algorithms systematically correct both multiplicative and additive biases and involve exact formulas for propagating the mean and covariance including the parameters in the test model. A comprehensive study is presented of robust parameter regimes for increasing filtering skill through stochastic parameter estimation for turbulent signals as the observation time and observation noise are varied and even when the forcing is incorrectly specified. The results here provide useful guidelines for filtering turbulent signals in more complex systems with significant model errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A two-parameter continuation method for computing numerical solutions of spin-1 Bose–Einstein condensates

We describe a novel two-parameter continuation method combined with a spectral-collocation method (SCM) for computing the ground state and excited-state solutions of spin-1 Bose–Einstein condensates (BEC), where the second kind Chebyshev polynomials are used as the basis functions for the trial function space. To compute the ground state solution of spin-1 BEC, we implement the single parameter continuation algorithm with the chemical potential μ as the continuation parameter, and trace the first solution branch of the Gross–Pitaevskii equations (GPEs). When the curve-tracing is close enough to the target point, where the normalization condition of the wave function is going to be satisfied, we add the magnetic potential λ as the second continuation parameter with the magnetization M as the additional constraint condition. Then we implement the two-parameter continuation algorithm until the target point is reached, and the ground state solution of the GPEs is obtained. The excited state solutions of the GPEs can be treated in a similar way. Some numerical experiments on {sup 23}Na and {sup 87}Rb are reported. The numerical results on the spin-1 BEC are the same as those reported in [10]. Further numerical experiments on excited-state solutions of spin-1 BEC suffice to show the robustness and efficiency of the proposed two-parameter continuation algorithm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Goal-oriented a-posteriori estimation of model error as an aid to parameter estimation

In this work, a Bayesian model calibration framework is presented that utilizes goal-oriented a-posterior error estimates in quantities of interest (QoIs) for classes of high-fidelity models characterized by PDEs. It is shown that for a large class of computational models, it is possible to develop a computationally inexpensive procedure for calibrating parameters of high-fidelity models of physical events when the parameters of low-fidelity (surrogate) models are known with acceptable accuracy. The main ingredients in the proposed model calibration scheme are goal-oriented a-posteriori estimates of error in QoIs computed using a so-called lower fidelity model compared to those of an uncalibrated higher fidelity model. The estimates of error in QoIs are used to define likelihood functions in Bayesian inversion analysis. A standard Bayesian approach is employed to compute the posterior distribution of model parameters of high-fidelity models. As applications, parameters in a quasi-linear second-order elliptic boundary-value problem (BVP) are calibrated using a second-order linear elliptic BVP. In a second application, parameters of a tumor growth model involving nonlinear time-dependent PDEs are calibrated using a lower fidelity linear tumor growth model with known parameter values.

A-posterior estimates↗

Sensitivity study of parameters important to Molten Salt Reactor Safety

This paper presents a molten salt reactor (MSR) design parameter sensitivity study using a nodal dynamic modelling methodology with explicitly modified point kinetics equation and Mann’s model for heat transfer. Six parameters that can impact MSR safety are evaluated. A MATLAB-Simulink model inspired by Thorcon’s 550MW th MSR is used for parameter evaluations. A safety envelope was formed to encapsulate power, maximum and minimum temperature, and temperature-induced reactivity feedback. The parameters are perturbed by ±30%. The parameters were then ranked by their subsequent impact on the considered safety envelope, which ranks acceptable parameter uncertainty. The model is openly available on GitHub.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of beating parameters in human induced pluripotent stem cells enables quantitative in vitro screening for cardiotoxicity

Human induced pluripotent stem cell (iPSC)-derived cardiomyocytes show promise for screening during early drug development. Here, we tested a hypothesis that in vitro assessment of multiple cardiomyocyte physiological parameters enables predictive and mechanistically-interpretable evaluation of cardiotoxicity in a high-throughput format. Human iPSC-derived cardiomyocytes were exposed for 30 min or 24 h to 131 drugs, positive (107) and negative (24) for in vivo cardiotoxicity, in up to 6 concentrations (3 nM to 30 uM) in 384-well plates. Fast kinetic imaging was used to monitor changes in cardiomyocyte function using intracellular Ca{sup 2+} flux readouts synchronous with beating, and cell viability. A number of physiological parameters of cardiomyocyte beating, such as beat rate, peak shape (amplitude, width, raise, decay, etc.) and regularity were collected using automated data analysis. Concentration–response profiles were evaluated using logistic modeling to derive a benchmark concentration (BMC) point-of-departure value, based on one standard deviation departure from the estimated baseline in vehicle (0.3% dimethyl sulfoxide)-treated cells. BMC values were used for cardiotoxicity classification and ranking of compounds. Beat rate and several peak shape parameters were found to be good predictors, while cell viability had poor classification accuracy. In addition, we applied the Toxicological Prioritization Index (ToxPi) approach to integrate and display data across many collected parameters, to derive “cardiosafety” ranking of tested compounds. Multi-parameter screening of beating profiles allows for cardiotoxicity risk assessment and identification of specific patterns defining mechanism-specific effects. These data and analysis methods may be used widely for compound screening and early safety evaluation in drug development. - Highlights: • Induced pluripotent stem cell-derived cardiomyocytes are promising in vitro models. • We tested if evaluation of cardiotoxicity is possible in a high-throughput format. • The assay shows benefits of automated data integration across multiple parameters. • Quantitative assessment of concentration–response is possible using iPSCs. • Multi-parametric screening allows for cardiotoxicity risk assessment.

60 APPLIED LIFE SCIENCES↗

High-throughput cardiac safety evaluation and multi-parameter arrhythmia profiling of cardiomyocytes using microelectrode arrays

Microelectrode arrays (MEAs) recording extracellular field potentials of human-induced pluripotent stem cell-derived cardiomyocytes (hiPS-CM) provide a rich data set for functional assessment of drug response. The aim of this work is the development of a method for a systematic analysis of arrhythmia using MEAs, with emphasis on the development of six parameters accounting for different types of cardiomyocyte signal irregularities. We describe a software approach to carry out such analysis automatically including generation of a heat map that enables quick visualization of arrhythmic liability of compounds. We also implemented signal processing techniques for reliable extraction of the repolarization peak for field potential duration (FPD) measurement even from recordings with low signal to noise ratios. We measured hiPS-CM's on a 48 well MEA system with 5 minute recordings at multiple time points (0.5, 1, 2 and 4 h) after drug exposure. We evaluated concentration responses for seven compounds with a combination of hERG, QT and clinical proarrhythmia properties: Verapamil, Ranolazine, Flecainide, Amiodarone, Ouabain, Cisapride, and Terfenadine. The predictive utility of MEA parameters as surrogates of these clinical effects were examined. The beat rate and FPD results exhibited good correlations with previous MEA studies in stem cell derived cardiomyocytes and clinical data. The six-parameter arrhythmia assessment exhibited excellent predictive agreement with the known arrhythmogenic potential of the tested compounds, and holds promise as a new method to predict arrhythmic liability. - Highlights: • Six parameters describing arrhythmia were defined and measured for known compounds. • Software for efficient parameter extraction from large MEA data sets was developed. • The proposed cellular parameter set is predictive of clinical drug proarrhythmia.

60 APPLIED LIFE SCIENCES↗

Effects of dry bulk density and particle size fraction on gas transport parameters in variably saturated landfill cover soil

Highlights: > The effects of soil physical properties on gas transport parameters were investigated. > Higher values of D{sub p} and k{sub a} exhibited in the '+gravel' than the '-gravel' fraction at same soil-air content ({epsilon}). > Recent power law models for D{sub p} (WLR) and k{sub a} (RPL) were modified. > Model parameters were linearly related to easily measurable dry bulk density ({rho}{sub b}). - Abstract: Landfill sites are emerging in climate change scenarios as a significant source of greenhouse gases. The compacted final soil cover at landfill sites plays a vital role for the emission, fate and transport of landfill gases. This study investigated the effects of dry bulk density, {rho}{sub b}, and particle size fraction on the main soil-gas transport parameters - soil-gas diffusivity (D{sub p}/D{sub o}, ratio of gas diffusion coefficients in soil and free air) and air permeability (k{sub a}) - under variably-saturated moisture conditions. Soil samples were prepared by three different compaction methods (Standard and Modified Proctor compaction, and hand compaction) with resulting {rho}{sub b} values ranging from 1.40 to 2.10 g cm{sup -3}. Results showed that D{sub p} and k{sub a} values for the '+gravel' fraction (<35 mm) became larger than for the '-gravel' fraction (<2 mm) under variably-saturated conditions for a given soil-air content ({epsilon}), likely due to enhanced gas diffusion and advection through less tortuous, large-pore networks. The effect of dry bulk density on D{sub p} and k{sub a} was most pronounced for the '+gravel' fraction. Normalized ratios were introduced for all soil-gas parameters: (i) for gas diffusivity D{sub p}/D{sub f}, the ratio of measured D{sub p} to D{sub p} in total porosity (f), (ii) for air permeability k{sub a}/k{sub a,pF4.1}, the ratio of measured k{sub a} to k{sub a} at 1235 kPa matric potential (=pF 4.1), and (iii) for soil-air content, the ratio of soil-air content ({epsilon}) to total porosity (f) (air saturation). Based on the normalized parameters, predictive power-law models for D{sub p}({epsilon}/f) and k{sub a}({epsilon}/f) models were developed based on a single parameter (water blockage factor M for D{sub p} and P for k{sub a}). The water blockage factors, M and P, were found to be linearly correlated to {rho}{sub b} values, and the effects of dry bulk density on D{sub p} and k{sub a} for both '+gravel' and '-gravel' fractions were well accounted for by the new models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Atomic Radius and Charge Parameter Uncertainty in Biomolecular Solvation Energy Calculations

Atomic radii and charges are two major parameters used in implicit solvent electrostatics and energy calculations. The optimization problem for charges and radii is under-determined, leading to uncertainty in the values of these parameters and in the results of solvation energy calculations using these parameters. This paper presents a method for quantifying this uncertainty in solvation energies using surrogate models based on generalized polynomial chaos (gPC) expansions. There are relatively few atom types used to specify radii parameters in implicit solvation calculations; therefore, surrogate models for these low-dimensional spaces could be constructed using least-squares fitting. However, there are many more types of atomic charges; therefore, construction of surrogate models for the charge parameter space required compressed sensing combined with an iterative rotation method to enhance problem sparsity. We present results for the uncertainty in small molecule solvation energies based on these approaches. Additionally, we explore the correlation between uncertainties due to radii and charges which motivates the need for future work in uncertainty quantification methods for high-dimensional parameter spaces.

Yang, Xiu↗

Exploring Critical Synthetic Parameters for Nanoscale ε-Fe 2 O 3 and Their Influence on Magnetic Behaviors

An intermediate polymorph of iron oxide, ε-Fe 2 O 3 , has attracted significant attention due to its giant coercive field ( H c ) and potential applications in high-frequency millimeter-wave absorption and high-density magnetic recording. However, the fabrication of ε-Fe 2 O 3 with high phase purity is still a challenge due to complicated synthetic procedures and a large variety of reaction parameters. In this study, we have identified critical reaction parameters to improve the phase purity of ε-Fe 2 O 3 , and the effects of all possible reaction parameters have been tested through systematic studies. A combination of structural and magnetic characterization techniques provides us with an accurate and reliable phase purity analysis of the ε-Fe 2 O 3 phase. Specifically, we observed that (1) the reaction temperature and time and (2) the addition of Ba are critical parameters to improve the phase purity. We identified the optimal conditions that maximize the coercivity and phase purity, giving insight into the effects of each parameter on the γ- to ε- to α-phase-transition pathway. We obtained nearly single-phase ε-Fe 2 O 3 (~87 wt % with ~13 wt % α-phase) with a large coercivity of H c = 20.6 kOe, enabling us to obtain pure ε-Fe 2 O 3 by a simple magnetic separation protocol, and tuned the H c of the ε-Fe 2 O 3 nanoparticles in the range of 4.0–20.6 kOe by controlling the reaction parameters. Furthermore, the structural properties of the resulting ε-Fe 2 O 3 nanoparticles are confirmed by characterizing their chemical and magnetic properties using X-ray absorption spectroscopy and X-ray magnetic circular dichroism measurements.

36 MATERIALS SCIENCE↗