Scaling Energy Efficient Retrofits for Small Commercial Apartment Buildings

With support from the U.S. Department of Energy’s (DOE) Building Technologies Office (BTO), the International Center for Appropriate and Sustainable Technology (ICAST) recently completed a three-year cooperative agreement to scale energy efficiency retrofits (EER) on small multifamily (MF) buildings. ICAST EER strategies ranged from low-hanging “direct install” of measures such as LED lighting, low-flow showerheads and aerators, and smart thermostats to major strategies such as HVAC replacement with high-efficiency boilers or heat pumps. As feasible, some projects also included the addition of renewable energy sources such as photo voltaic (PV) solar. When ICAST began the BTO project, it operated in two states and oversaw EER at approximately 80 MF buildings per year. With assistance from BTO, ICAST has grown significantly and now has staff in six states with MF EER projects in another seven, and performed EER on 956 MF buildings. ). ICAST was able to successfully execute this project by 1) Improving viability and efficiency of its processes, 2) Launching two new services and 3) Creating an affiliate program. For the most part, ICAST focused on a specific type of MF property: naturally occurring affordable housing (NOAH), because it is a significantly underserved market within the hard-to-serve MF market. NOAHs are typically smaller properties (5 to 64 units), owned by small organizations or individual investors looking for positive cash flow. ICAST believes the NOAH market can be successfully served with a one-stop-shop approach that makes it easy, hassle-free, and cost-effective for owners to acquire green upgrades for their property(ies). With the assistance of BTO funding, ICAST successfully used the cited EER methods and strategies to scale-up its OSS approach to service a greater number of MF housing and expand into new geographies. Additionally, support from BTO helped ICAST create self-sustaining programs which will not need to rely on on-going funding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing Retrofit Wall Performance Predicted from Hygrothermal Simulations to Measurements

Over the past few years ORNL has been showing that WUFI® can be used to predict the moisture performance of walls when exposed to diffusion of water vapor, convection of moist air through the wall, and solar driven moisture. This is accomplished by comparing the hygrothermal simulation results to carefully instruments walls exposed to these phenomena in a climate chamber. In FY 2018, three stick-built walls were succumbed to typical Chicago, Illinois weather conditions in Oak Ridge National Laboratory’s Heat, Air and Moisture chamber. The measured temperature, relative humidity, and moisture content within these walls were compared with WUFI hygrothermal simulation results. In FY 2019, similar experiments and comparisons with WUFI results were completed with two walls, a structural insulated panel-based wall and a concrete masonry unit-based wall. In FY 2020, experiments were completed for a probable exterior retrofit of a wall which included adding cavity and continuous insulation. Two pairs of walls were tested by exposing them to Chicago winter weather with a positive pressure pushing outside air into the wall. The results from the FY 2020 experiments are reported here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Front-End Engineering Design Study for Retrofit Post-Combustion Carbon Capture on a Natural Gas Combined Cycle Power Plant

The objective of the project is to conduct a Front-End Engineering Design (FEED) study to determine the technical and economic feasibility of installing a retrofit, post-combustion, carbon capture facility on a commercially operating, natural gas-fired, combined cycle (NGCC) power plant. The Electric Power Research Institute (EPRI), California Resources Corporation (CRC), and Fluor Corporation used Fluor's Econamine FG Plus SM (EFG+) conducted the FEED study for capturing CO 2 produced by CRC's 550 MWe Elk Hills Power Plant (EHPP), located in the Elk Hills Oil Field near Tupman, Kern County, California. The EHPP was commissioned in 2003 and is powered by two General Electric 7FA gas turbines, with two heat recovery steam generators (HRSGs) providing steam to a General Electric D11 steam turbine. The target capture amount is 4,000 tonnes CO 2 /day for use in either enhanced oil recovery or dedicated geological saline storage located on CRC property at or nearby EHPP. This CO 2 is captured from a combination of the CO 2 emitted from the flue gas from EHPP and the flue gas generated from a natural gas-fired auxiliary boiler that supplies steam to the EFG+ process.

03 NATURAL GAS↗

Aleut Community Store Refrigeration Efficiency Retrofit with Heat Recovery (Final Report)

The Project Goal is to improve the energy efficiency of the Aleut Community Store by installing deep energy retrofits. Project Objectives are: 1) Replace refrigeration equipment and display cases with an energy efficient refrigeration system and energy efficient refrigeration display cases; utilize waste heat to heat the building; and 2) Lower cost of energy and maintenance for Aleut Community Store by $44,385 (energy and maintenance)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GE 1.5 ESS Wind Turbine Retrofit Controller Development (CRADA Final Report)

National Renewable Energy Laboratory (NREL) and Bachmann electronic corp. will collaborate on the development of a software application to be used on an existing aftermarket Bachmann controller, utilizing and existing Bachmann software platform, which will be used on the General Electric (GE) 1.5 ESS wind turbine. This retrofit will significantly enhance NREL’s ability to control experiments it is planning to conduct on the GE 1.5 wind turbine as part of the Gearbox Reliability Collaborative, Atmosphere to Electrons and other future R&D. The proposed work is leveraging ongoing Department of Energy (DOE) Annual Operating Plan activities on the GE 1.5 ESS wind turbine at the National Wind Technology Center.

17 WIND ENERGY↗

Development of Wireless Power Technology for Use in Electrochromic Window Retrofit Applications

Electrochromic (EC) windows, often referred to as smart windows, have the ability to adjust their tint in response to electrical signals, thereby controlling the amount of sunlight and heat entering a building. This dynamic modulation can lead to significant energy savings by reducing the reliance on artificial lighting and minimizing the load on heating, ventilation, and air conditioning (HVAC) systems. However, the widespread adoption of electrochromic window technology, especially in existing buildings, faces challenges, particularly concerning the installation cost associated with the need for electrical wiring to power and control the EC glass (tinting). In this project, GuRu Wireless demonstrated that it’s mmWave-based wireless power energy transfer technology can provide the necessary power for operation of electrochromic windows, wirelessly, and address the wiring challenges of electrochromic windows in retrofit applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

COGIHTO: Comprehensive Geothermal Integrated HVAC Retrofits in Disadvantaged Communities

Geothermal heating and cooling (GHC) systems offer one of the most efficient approaches to provide space conditioning and water heating in buildings. Due to the relatively stable temperature of the ground year-round, these systems can provide an efficient solution to decarbonize heating systems. Yet this technology has faced limited market adoption due to its high first cost. This project seeks to address this barrier by designing a community GHC system at a public housing development in New York, taking advantage of load diversity (in terms of the timing and amount of heating / cooling used per person) that a larger community offers to reduce the size and thus first cost of a GHC system. Project success would result in societal benefit from reduced energy and fossil fuel use, reduced local emissions, and improved comfort, which would positively impact the health and well-being this community. This report presents the findings from Phase 1 project supported by the Department of Energy’s Geothermal Technologies Office and includes the technical design of a GHC at a public housing development in New York. To support the success of a potential deployment of a GHC system, the team conducted community engagement and prepared an assessment of the local workforce needs. The project team, led by EPRI, considered a subset of NYCHA housing developments that were previously identified by NYCHA as suitable for GHC retrofits. This report presents the site selection criteria the team developed and the overall score assigned to each of the eight developments considered. One site was selected for focus of the technical design: Stapleton Houses in Staten Island, a mid-size development with roughly 700 apartments across 6 buildings. The site has an existing hot water hydronic loop served by natural gas boilers for space heating and water heating. The technical design partner assessed baseline energy consumption at the site and established thermal models of the apartment buildings to assist in the design. The team considered several GHC system configurations and selected a hybrid geothermal design fed from water-source heat pumps with auxiliary gas boilers in a central plant. This design best leveraged the existing site configuration and minimized costs due to additional electrical infrastructure upgrades. The report also details the feedback received from community engagement efforts and the findings from the workforce needs assessment and workforce transition plan. Members of the site maintenance staff and the resident advisory council were interviewed for their input and feedback about both the site’s existing heating/cooling infrastructure and how a construction project would impact resident life. This feedback was taken into consideration when completing the geothermal system design. Research was conducted into existing workforce development opportunities available to NYCHA residents. A workforce development plan was established using information from NYCHA’s resident economic empowerment and sustainability group, along with training material and curriculum from the International Ground Source Heat Pump Association (IGSHPA).

15 GEOTHERMAL ENERGY↗

Countrywide LED Lighting Retrofit for Safety, Visibility, and Energy Efficiency (Final Technical Report)

The project supported national clean energy goals by reducing electricity demand and improving energy efficiency in public infrastructure. Tasks defined in the Statement of Project Objectives included site assessments, retrofit planning, lighting design optimization, installation, monitoring, and reporting. All milestones and go/no-go decision points were successfully met.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Realistic Estimation of CO2 Emission Reductions Due to Building Retrofit

Constant CO2 emission factors of electricity are often used to study the emissions of buildings. However, in the era of increased renewable energy for power generation, emission factors of electricity are dynamically changing. This study is to investigate the impact of dynamic CO2 emission factors, which are more realistic than constant ones, on the emission reductions due to building retrofits. The results reveal that if dynamic CO2 emission factors are used for U.S. medium office buildings, improving the efficiency of lighting or electric equipment will lead to more emission reductions in locations with high wind power penetration (e.g., 12% more reductions in Rochester) and fewer reductions in locations with high solar power penetration (e.g., 8% fewer reductions in San Diego). As for improving envelope insulation, dynamic CO2 emission factors have more impact on the emission reductions in hot climates than in cold climates.

Lou, Yingli↗

Exploring Cost-Effective, High Performance Residential Retrofits for Affordable Housing in the Hot Humid Climate

In 2009, a Department of Energy Building America team led by the Florida Solar Energy Center began working with partners to find cost-effective paths for improving the energy performance of existing homes in the hot humid climate. A test-in energy audit and energy use modeling of the partner's proposed renovation package was performed for 41 affordable and middle income foreclosed homes in Florida and Alabama. HERS1 Indices ranged from 92 to 184 with modeled energy savings ranging from 3% to 50% (average of 26%). Analyses and recommendations were discussed with partners to encourage more efficient retrofits, highlight health and safety issues, and gather feedback on incremental cost of high performance measures. Ten completed renovations have modeled energy savings ranging from 9% to 48% (average 31%.) This paper presents the project's process including our findings thus far and highlights of the first home to meet the target HERS Index of 70.

14 SOLAR ENERGY↗

Sustainable Retrofit of Residential Roofs Using Metal Roofing Panels, Thin-Film Photovoltaic Laminates, and PCM Heat Sink Technology

During September-October 2009, research teams representing Metal Construction Association (the largest North American trade association representing metal building manufacturers, builders, and material suppliers), CertainTeed (one of the largest U.S. manufacturers of thermal insulation and building envelope materials), Unisolar (largest U.S. producer of amorphous silicone photo-voltaic (PV) laminates), Phase Change Energy (manufacturer of bio-based PCM), and Oak Ridge National Laboratory (ORNL) installed three experimental attics utilizing different roof retrofit strategies in the ORNL campus. The main goal of this project was experimental evaluation of a newly-developed sustainable re-roofing technology utilizing amorphous silicone PV laminates integrated with metal roof and PCM heat sink. The experimental attic with PV laminate was expected to work during the winter time as a passive solar collector with PCM storing solar heat, absorbed during the day, and increasing overall attic air temperature during the night.

14 SOLAR ENERGY↗

Retrofitting the Streetlights in Boise, Idaho

Boise, Idaho is using an energy efficiency grant to retrofit hundreds of streetlights throughout the downtown area with energy-efficient LED bulbs, which will save money and improve safety and local quality of life.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Glove port retrofit assembly and method of replacing components

What is disclosed is a system for retrofitting a sealed enclosure for performing work therein having an outer enclosure assembly configured to be clamped to the outer annular face of a port ring and form a sealed engagement with the outer annular surface of the port ring, a change assembly having an inner ring and an access element wherein the inner ring has a first annular cylinder body that is sized to be slidably received by the port ring and the access element is configured to be sealably and slidably positioned within the first annular cylinder body of the inner ring.

42 ENGINEERING↗

Bedford Farmhouse High Performance Retrofit Prototype

In this case study, Building Science Corporation partnered with Habitat for Humanity of Greater Lowell on a retrofit of a mid-19th century farmhouse into affordable housing meeting Building America performance standards.

affordable housing↗

Retrofitting America: A 1970s Home Energy Efficiency Analysis

This paper describes a modeling tool that Building America research team CARB developed to identify the energy benefits of various retrofit energy efficiency measures for a typical 1970’s ranch home in ten cities across four climate zones in the United States.

CARB↗

Crowne Plaza Renovation Retrofit Case Study

InterContinental Hotels Group (IHG) and its franchise partner B.F. Saul Company Hospitality Group (B.F. Saul Co.) partnered with the Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce energy consumption by at least 30% versus requirements set by Standard 90.1-2004 of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of North America (IESNA) as part of DOE’s Commercial Building Partnerships (CBP) Program.

crowne plaza↗