Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Coulomb excitation of the proton-dripline nucleus {sup 20}Na

The low-energy structure of the proton dripline nucleus {sup 20}Na has been studied using Coulomb excitation at the TRIUMF-ISAC radioactive ion beam facility. A 1.7-MeV/nucleon {sup 20}Na beam of {approx}5x10{sup 6} ions/s was Coulomb excited by a 0.5-mg/cm{sup 2nat}Ti target. Scattered beam and target particles were detected by the BAMBINO segmented Si detector while {gamma} rays were detected by two TIGRESS HPGe clover detectors set perpendicular to the beam axis. Coulomb excitation from the 2{sup +} ground state to the first excited 3{sup +} and 4{sup +} states was observed, and B({lambda}L) values were determined using the 2{sup +}{yields}0{sup +} de-excitation in {sup 48}Ti as a reference. The resulting B({lambda}L){down_arrow} values are B(E2;3{sup +}{yields}2{sup +})=55{+-}6 e{sup 2} fm{sup 4} (17.0{+-}1.9 W.u.), B(E2;4{sup +}{yields}2{sup +})=35.7{+-}5.7 e{sup 2} fm{sup 4} (11.1{+-}1.8 W.u.), and B(M1;4{sup +}{yields}3{sup +})=0.154{+-}0.030 {mu}{sub N}{sup 2} (0.086{+-}0.017 W.u.). These measurements provide the first experimental determination of B({lambda}L) values for this proton dripline nucleus of astrophysical interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the Structure and Geometry of Biomolecular Binding Motifs (Hydrogen-Bonding, Stacking, X-H· · ·π): WFT and DFT Calculations

The strengths of noncovalent interactions are generally very sensitive to a number of geometric parameters. Among the most important of these parameters is the separation between the interacting moieties (in the case of an intermolecular interaction, this would be the intermolecular separation). Most works seeking to characterize the properties of intermolecular interactions are mainly concerned with binding energies obtained at the potential energy minimum (as determined at some particular level of theory). In this work, in order to extend our understanding of these types of noncovalent interactions, we investigate the distance dependence of several types of intermolecular interactions, these are hydrogen bonds, stacking interactions, dispersion interactions, and X-H· · ·π interactions. There are several methods that have traditionally been used to treat noncovalent interactions as well as many new methods that have emerged within the past three or four years. Here we obtain reference data using estimated CCSD(T) values at the complete basis set limit (using the CBS(T) method); potential energy curves are also produced using several other methods thought to be accurate for intermolecular interactions, these are MP2/ccpVTZ, MP2/aug-cc-pVDZ,MP2/6-31G*(0.25), SCS(MI)-MP2/cc-pVTZ, estimated MP2.5/CBS, DFT-SAPT/ aug-cc-pVTZ, DFT/M06-2X/6-311+G(2df,2p), and DFT-D/TPSS/6-311++G(3df,3pd). The basis set superposition error is systematically considered throughout the study. It is found that the MP2.5 and DFTSAPT methods, which are both quite computationally intensive, produce potential energy curves that are in very good agreement to those of the reference method. Among the MP2 techniques, which can be said to be of medium computational expense, the best results are obtained with MP2/cc-pVTZ and SCS(MI)-MP2/cc-pVTZ. DFT-D/TPSS/6-311++G(3df,3pd) is the DFT-based method that can be said to give the most well-balanced description of intermolecular interactions.

08 HYDROGEN↗

Understanding Active Sites in Pyrolyzed Fe–N–C Catalysts for Fuel Cell Cathodes by Bridging Density Functional Theory Calculations and 57 Fe Mössbauer Spectroscopy

Pyrolyzed Fe–N–C materials are promising platinum-group-metal-free catalysts for proton-exchange membrane fuel cell cathodes. However, the detailed structure, oxidation, and spin states of their active sites are still undetermined. As such, 57 Fe Mössbauer spectroscopy has identified FeN x moieties as the most active sites, with their fingerprint being a doublet in low-temperature Mössbauer spectra. However, the interpretation of the doublets for such materials has lacked theoretical basis. Here, we applied density functional theory to calculate the quadrupole splitting energy of doublets (Δ E QS ) for a range of FeN x structures in different oxidation and spin states. The calculated and experimental values are then compared for a reference Fe–N–C catalyst, whereas further information on the Fe oxidation and spin states was obtained from electron paramagnetic resonance, superconducting quantum interference device, and 57 Fe Mössbauer spectroscopy under external magnetic field. The combined theoretical and experimental results identify the main presence of FeN x moieties in Fe(II) low-spin and Fe(III) high-spin states, whereas a minor fraction of sites could exist in the Fe(II) S = 1 state. From the analysis of the 57 Fe Mössbauer spectrum under the external magnetic field and the comparison of calculated and measured Δ E QS values, we assign the experimental doublet D1 with a mean Δ E QS value of around 0.9 mm·s –1 to Fe(III)N 4 C 12 moieties in high-spin state and the experimental doublet D2 with a mean Δ E QS value of around 2.3 mm·s –1 to Fe(II)N 4 C 10 moieties in low and medium spin. These conclusions indicate that D1 corresponds to surface-exposed sites, whereas D2 may correspond either to bulk sites that are inaccessible to O 2 or to surface sites that bind O 2 weaker than D1.

fuel cell↗

High-Resolution Fire Weather Index Data for the Conterminous US (1980–2099), Version 1

This dataset presents a suite of high-resolution fire weather index datasets calculated from observation (gridMet, Livneh, Daymet V4), reanalysis (AgERA5), downscaled hydro-climate projections over the conterminous United States (CONUS) based on multiple selected Global Climate Models (GCMs) from the Coupled Model Intercomparison Project Phase 6 (CMIP6). Aside from the daily FWI datasets, we also include a set of FWI extreme indicators at annual, seasonal, and monthly scales, including 1) fwixx: maximum FWI; 2) fwisa: mean FWI. For annual fwisa, it refers to the season with the maximum seasonal average; 3) fwils: Length of fire season over a specified period, where fire season is defined as the days exceeding the median value of the normalized FWI during the reference period (1980-1984); 4) fwixd: Number of extreme fire weather days over a specified period, where extreme day is defined as the day with FWI > the 95th percentile of the FWI during the reference period (1980-1984). All FWI datasets cover 1980-2020 baseline and the model simulated products including the downscaled products additionally include 2021-2099 near-future periods under the high-end (SSP585) emission scenario.

54 ENVIRONMENTAL SCIENCES↗

A coarse-grained deep neural network model for liquid water

We introduce a coarse-grained deep neural network (CG-DNN) model for liquid water that utilizes 50 rotational and translational invariant coordinates and is trained exclusively against energies of ~30 000 bulk water configurations. Our CG-DNN potential accurately predicts both the energies and the molecular forces of water, within 0.9 meV/molecule and 54 meV/Å of a reference (coarse-grained bond-order potential) model. The CG-DNN water model also provides good prediction of several structural, thermodynamic, and temperature dependent properties of liquid water, with values close to those obtained from the reference model. More importantly, CG-DNN captures the well-known density anomaly of liquid water observed in experiments. Our work lays the groundwork for a scheme where existing empirical water models can be utilized to develop a fully flexible neural network framework that can subsequently be trained against sparse data from high-fidelity albeit expensive beyond-DFT calculations.

42 ENGINEERING↗

What Is the Reference? An Examination of Alternatives to the Reference Sources Used in IES TM-30-15

A study was undertaken to document the role of the reference illuminant in the IES TM-30-15 method for evaluating color rendition. TM-30-15 relies on a relative reference scheme; that is, the reference illuminant and test source always have the same correlated color temperature (CCT). The reference illuminant is a Planckian radiator, model of daylight, or combination of those two, depending on the exact CCT of the test source. Three alternative reference schemes were considered: 1) either using all Planckian radiators or all daylight models; 2) using only one of ten possible illuminants (Planckian, daylight, or equal energy), regardless of the CCT of the test source; 3) using an off-Planckian reference illuminant (i.e., a source with a negative Duv). No reference scheme is inherently superior to another, with differences in metric values largely a result of small differences in gamut shape of the reference alternatives. While using any of the alternative schemes is more reasonable in the TM-30-15 evaluation framework than it was with the CIE CRI framework, the differences still ultimately manifest only as changes in interpretation of the results. References are employed in color rendering measures to provide a familiar point of comparison, not to establish an ideal source.

CAM02-UCS↗

Computational and analytical comparison of flux discretizations for the semiconductor device equations beyond Boltzmann statistics

We compare three thermodynamically consistent numerical fluxes known in the literature, appearing in a Voronoï finite volume discretization of the van Roosbroeck system with general charge carrier statistics. Our discussion includes an extension of the Scharfetter–Gummel scheme to non-Boltzmann (e.g. Fermi–Dirac) statistics. It is based on the analytical solution of a two-point boundary value problem obtained by projecting the continuous differential equation onto the interval between neighboring collocation points. Hence, it serves as a reference flux. The exact solution of the boundary value problem can be approximated by computationally cheaper fluxes which modify certain physical quantities. One alternative scheme averages the nonlinear diffusion (caused by the non-Boltzmann nature of the problem), another one modifies the effective density of states. To study the differences between these three schemes, we analyze the Taylor expansions, derive an error estimate, visualize the flux error and show how the schemes perform for a carefully designed p-i-n benchmark simulation. We present strong evidence that the flux discretization based on averaging the nonlinear diffusion has an edge over the scheme based on modifying the effective density of states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using machine learning to predict the correlation of spectra using SDSS magnitudes as an improvement to the Locus Algorithm

The Locus Algorithm is a new technique to improve the quality of differential photometry by optimising the choices of reference stars. At the heart of this algorithm is a routine to assess how good each potential reference star is by comparing its SDSS magnitude values to those of the target star. In this way, the difference in wavelength-dependent effects of the Earth’s atmospheric scattering between target and reference can be minimised. This paper sets out a new way to estimate the quality of each reference star using machine learning. A random subset of stars from SDSS with spectra was chosen. For each one, a suitable reference star, also with a spectrum, was chosen. The correlation between the two spectra in the SDSS r band (between 550 nm and 700 nm) was taken to be the gold-standard measure of how well they match up for differential photometry. The five SDSS magnitude values for each of these stars were used as predictors. A number of supervised machine learning models were constructed on a training set of the stars and were each evaluated on a testing set. The model using Support Vector Regression had the best performance of these models. It was then tested on a final, hold-out, validation set of stars to get an unbiased measure of its performance. With an R 2 of 0.62, the SVR model presents enhanced performance for the Locus Algorithm technique.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Field Evaluation of Reference Cell Using Spectral Measurements: Preprint

Spectral irradiance measurements as opposed to modeled spectral values are used to evaluate the effects of changing spectral distributions on the output of reference solar cells. Comparisons are made on a one-axis tracking surface to a Class A pyranometer. The ratio of the reference cells to reference pyranometers exhibit a bias over the day. Spectral and temperature modeling reproduce most but not all changes in the ratio over the day. Sources for this difference in modeling and performance of the reference cells are examined.

14 SOLAR ENERGY↗

Detection of Cement Leakage After Vertebroplasty with a Non-Flat-Panel Angio Unit Compared to Multidetector Computed Tomography - An Ex Vivo Study

The purpose of this study was to investigate the detection of cement leakages after vertebroplasty using angiographic computed tomography (ACT) in a non-flat-panel angio unit compared to multidetector computed tomography (MDCT). Vertebroplasty was performed in 19 of 33 cadaver vertebrae (23 thoracic and 10 lumbar segments). In the angio suite, ACT (190{sup o}; 1.5{sup o} per image) was performed to obtain volumetric data. Another volumetric data set of the specimen was obtained by MDCT using a standard algorithm. Nine multiplanar reconstructions in standardized axial, coronal, and sagittal planes of every vertebra were generated from both data sets. Images were evaluated on the basis of a nominal scale with 18 criteria, comprising osseous properties (e.g., integrity of the end plate) and cement distribution (e.g., presence of intraspinal cement). MDCT images were regarded as gold standard and analyzed by two readers in a consensus mode. Rotational acquisitions were analyzed by six blinded readers. Results were correlated with the gold standard using Cohen's {kappa}-coefficient analysis. Furthermore, interobserver variability was calculated. Correlation with the gold standard ranged from no correlation (osseous margins of the neuroforamen, {kappa} = 0.008) to intermediate (trace of vertebroplasty canula; {kappa} = 0.615) for criteria referring to osseous morphology. However, there was an excellent correlation for those criteria referring to cement distribution, with {kappa} values ranging from 0.948 (paravertebral cement distribution) to 0.972 (intraspinal cement distribution). With a minimum of {kappa} = 0.768 ('good correlation') and a maximum of {kappa} = 0.91 ('excellent'), interobserver variability was low. In conclusion, ACT in an angio suite without a flat-panel detector depicts a cement leakage after vertebroplasty as well as MDCT. However, the method does not provide sufficient depiction of osseous morphology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phantom Study Investigating the Accuracy of Manual and Automatic Image Fusion with the GE Logiq E9: Implications for use in Percutaneous Liver Interventions

PurposeTo determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions.Materials and MethodsCT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers.ResultsMean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values.ConclusionThe accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Group additivity values for entropy and heat capacities of C 2 –C 8 alkanes, alkyl hydroperoxides, and their radicals

Group additivity values for the thermodynamic properties of oxygenated radicals are poorly determined due to the absence of high quality reference data. Here, a set of 58 group additive values (GAV) for the standard entropy and heat capacity of relevance to alkane oxidation is derived from fits to an extensive and accurate database of standard entropies (298.15 K) and heat capacities (300–3000 K) recently calculated with the “STAR-1D” formalism. The 192 species in this database represent the alkanes (RH), alkyl radicals ($\dot{R}$), alkyl hydroperoxides (RO 2 H), alkyl-peroxy (R$\dot{O}$ 2 ) and hydroperoxy-alkyl ($\dot{Q}$OOH) radicals for all of the isomers of C 2 –C 5 alkane fuels and a select number of isomers of C 6 –C 9 species. The STAR-1D thermochemical data for this set of species was previously obtained from a coupling of scaled B2PLYPD3/cc-pVTZ vibrational analyses with scaled ωB97X-D/cc-pVTZ one-dimensional hindered rotor corrections. The 2σ uncertainties in the GAV results relative to the STAR-1D data set are 2.4 cal K –1 mol –1 for the entropies and at most 2.0 cal K –1 mol –1 for the heat capacities in the temperature range 500–800 K. The 2σ fitting uncertainties in the heat capacity gradually reduce at higher temperatures reaching a value of 0.8 cal K –1 mol –1 at 2000 K decreasing to only 0.5 cal K –1 mol –1 at 3000 K. The high degree of accuracy for the GAV representations is obtained through the introduction of various new group terms, together with the re-optimization of existing group terms. Among the full set of 58 GAV terms, 25 include non-next-nearest neighbor interactions (NNI) and β-corrections. The updated GAVs can be applied in the prediction of entropies and heat capacities for a wide range of hydrocarbons and hydroperoxide species and their radicals, which is important to the accurate prediction of fuel reactivity at low-temperatures in the range 600–1000 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Introducing a risk aggregation rationale for mapping risks to aquifers from point- and diffuse-sources–proof-of-concept using contamination data from industrial lagoons

Highlights: • Aquifer risk mapping is introduced for contaminants acting as point/diffuse-sources. • Innovations are framed by risk cells based on Source-Pathway-Receptor-Source (SPRC). • Point-source (Risk Cell 1) and diffuse-source (Risk Cell 2) use sets of algorithms. • Algorithms include MODPATH, DRASTIC, GWPI and are integrated on a modular basis. • Risk Cells 1/2 are aggregated giving fit-for-purpose results as proof-of-concept. - Abstract: Proof-of-concept for a methodology is presented on mapping risks to aquifers impacted from point- and diffuse-sources, where mapping or indexing refers to relative but not absolute values. The methodology is generic but tested by investigating impacts of a risk exposure from industrial wastewater lagoons. The methodology is innovative for using the qualitative Source-Pathways-Receptors-Consequences (SPRC) framework to aggregate risks from both point-sources and diffuse-sources through breaking down a study area into SPRC risk cells. In this paper, two risk cells are required as: (i) Cell 1 is directly impacted from a point-source; and (ii) Cell 2 is impacted by diffuse-sources to slowly contaminate the aquifer by infiltration over a large area. Indexing both types of risk cells generically comprise three tiered processes: (i) binary indexing establishes if a grid cell is at a potential risk or not; (ii) graded indexing measures the strength of the risk pathways from source to receptors; and (iii) local indexing measures intrinsic potentials at the grid cell to propagate the risk. These three processes apply to both point- and diffuse-sources but with different mathematical formulations. The proof-of-concept for the methodology of risk aggregation using the SPRC framework is supported by results of a study area, in which a set of performance metrics are used by comparing with the measurements. The results are found to be fit-for-purpose for serving as proactive management tools and to provide a deeper insight into potential impacts of adverse effects.

54 ENVIRONMENTAL SCIENCES↗

Microstructure, magnetic and microwave absorptive behavior of doped W-type hexaferrite nanoparticles prepared by co-precipitation method

Highlights: • High frequency properties of substituted W-type Sr-hexaferrite. • Saturation magnetization of samples is decreased with increasing of dopants content. • The ferrite sample covers about 6 GHz of bandwidth in K{sub u} band. • The optimum substituted samples can be used as a potential magnetic loss material. • Sample contain x = 0.4 of dopants have shown greater than 90% of reflection loss. - Abstract: Substituted W-type hexaferrite nanoparticles of SrZn{sub 2−x}Co{sub x/2}Ni{sub x/2}Fe{sub 16}O{sub 27} were synthesized by a chemical co-precipitation method. The X-ray diffraction results confirmed that W-type ferrite was identified as the main phase in whole samples in the range of x = 0–0.4. According to magnetic hysteresis loops, with increasing of substituted cations, saturation of magnetization increased and coercivity decreased due to crystalline site occupation of Zn with Ni and Co cations. The microwave reflection loss analysis results in the K{sub u} band (12–18 GHz) show that the highest value of reflection loss of samples was −29.11 dB at frequency of 14.57 GHz with an absorption bandwidth of more than 6 GHz by choosing reflection loss value of −10 dB as a reference. The results indicate that, the sample with appropriate amount of substituted cations hold great promise for microwave device applications.

36 MATERIALS SCIENCE↗

Biased Spin-State Energetics of Fe(II) Molecular Complexes within Density-Functional Theory and the Linear-Response Hubbard U Correction

The spin-state energetics of six Fe(II) molecular complexes are computed using the linear-response Hubbard U approach within DFT. The adiabatic energy differences, ΔE H-L , between the high-spin (S = 2) and the low-spin (S = 0) states are computed and compared with accurate-coupled cluster-corrected CASPT2 results. We show that DFT+U fails in correctly capturing the ground state for strong-field ligands yielding ΔE H-L that are almost constant throughout the molecular series. This bias toward high spin together with the metal/ligand charge transfer upon U correction are here quantified and explained using molecular orbital diagrams involving both σ- and π-bonding interactions. Furthermore, with increasing ligand-field strengths this bias also increases owing to the stronger molecular character of the metal/ligand Kohn–Sham orbitals thus resulting in large deviations from the reference larger than 4 eV. Smaller values of U can be employed to mitigate this effect and recover the right energetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent progress in L-H transition studies at JET: Tritium, Helium, Hydrogen and Deuterium

In this report we present an overview of results from a series of L-H transition experiments undertaken at JET since the installation of the ITER-like-wall (JET-ILW), with Beryllium wall tiles and a Tungsten divertor. Tritium, Helium and Deuterium plasmas have been investigated. Initial results in Tritium show ohmic L-H transitions at low density and the power threshold for the L-H transition (P LH ) is lower in Tritium plasmas than in Deuterium ones at low densities, while we still lack contrasted data to provide a scaling at high densities. In Helium plasmas there is a notable shift of the density at which the power threshold is minimum (n e,min ) to higher values relative to Deuterium and Hydrogen references. Above n e,min (He) the L-H power threshold at high densities is similar for D and He plasmas. Transport modelling in slab geometry shows that in Helium neoclassical transport competes with interchange-driven transport, unlike in Hydrogen isotopes. Measurements of the radial electric field in Deuterium plasmas show that E r shear is not a good indicator of proximity to the L-H transition. Transport analysis of ion heat flux in Deuterium plasmas show a non-linearity as density is decreased below n e,min . Lastly, a regression of the JET-ILW Deuterium data is compared to the 2008 ITPA scaling law.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel adaptive discrete cosine transform-domain filter for gap-inpainting of high resolution PET scanners

Purpose: Several positron emission tomography (PET) scanners with special detector block arrangements have been developed in recent years to improve the resolution of PET images. However, the discontinuous detector blocks cause gaps in the sinogram. This study proposes an adaptive discrete cosine transform-based (aDCT) filter for gap-inpainting. Methods: The gap-corrupted sinogram was morphologically closed and subsequently converted to the DCT domain. A certain number of the largest coefficients in the DCT spectrum were identified to determine the low-frequency preservation region. The weighting factors for the remaining coefficients were determined by an exponential weighting function. The aDCT filter was constructed and applied to two digital phantoms and a simulated phantom introduced with various levels of noise. Results: For the Shepp-Logan head phantom, the aDCT filter filled the gaps effectively. For the Jaszczak phantom, no secondary artifacts were induced after aDCT filtering. The percent mean square error and mean structure similarity of the aDCT filter were superior to those of the DCT2 filter at all noise levels. For the simulated striatal dopamine innervation study, the aDCT filter recovered the shape of the striatum and restored the striatum to reference activity ratios to the ideal value. Conclusions: The proposed aDCT filter can recover the missing gap data in the sinogram and improve the image quality and quantitative accuracy of PET images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-39: Dose Reduction Strategy Using Attenuation-Based Tube Current Modulation Method in CBCT for IGRT

Purpose: To reduce radiation dose to the patients, tube current modulation (TCM) method has been actively used in diagnostic CT systems. However, TCM method has not yet been applied to a kV-CBCT system on a LINAC machine. The purpose of this study is to investigate whether the use of TCM method is desirable in kV-CBCT system for IGRT. We have developed an attenuation-based tube current modulation (a-TCM) method using the prior knowledge of treatment CT image of a patient. Methods: Patients go through a diagnostic CT scan for RT planning; therefore, using this prior information of CT images, one can estimate the total attenuation of an x-ray through the patient body in a CBCT setting for radiation therapy. We performed a numerical study incorporating major factors into account such as polychromatic x-ray, scatter, noise, and bow-tie filter to demonstrate that a-TCM method can produce equivalent quality of images at reduced imaging radiation doses. Using the CT projector program, 680 projection images of the pediatric XCAT phantom were obtained both in conventional scanning condition, i.e., without modulating the tube current, and in the proposed a-TCM scanning condition. FDK reconstruction algorithm was used for image reconstruction, and the organ dose due to imaging radiation has been calculated in both cases and compared using GATE/Geant4 simulation toolkit. Results: Reconstructed CT images in the a-TCM method showed similar SSIM values and noise properties to the reference images acquired by the conventional CBCT. In addition, reduction of organ doses ranged from 12% to 27%. Conclusion: We have successfully demonstrated the feasibility and dosimetric merit of the a-TCM method for kV-CBCT, and envision that it can be a useful option of CBCT scanning that provides patient dose reduction without degrading image quality.

60 APPLIED LIFE SCIENCES↗