Single-Molecule Raman Spectroscopy: A Probe of Charge Transfer and Plasmonic Fields
No abstract prepared.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
We investigate the thermal properties of thin films formed by single- and multi-walled carbon nanotubes submitted to laser irradiation using Raman scattering as a probe of both the tube morphology and the local temperature. The nanotubes were submitted to heating/cooling cycles attaining high laser intensities ({approx}1.4 MW/cm{sup 2}) under vacuum and in the presence of an atmosphere, with and without oxygen. We investigate the heat diffusion of the irradiated nanotubes to their surroundings and the effect of laser annealing on their properties. The presence of oxygen during laser irradiation gives rise to an irreversible increase of the Raman efficiency of the carbon nanotubes and to a remarkable increase of the thermal conductivity of multi-walled films. The second effect can be applied to design thermal conductive channels in devices based on carbon nanotube films using laser beams.
The Raman scattering by isotopically pure {sup 12}C and {sup 13}C diamond single crystals and by isotopically mixed {sup 12.5}C diamond single crystals is studied at a high accuracy. The studies are performed over a wide pressure range up to 73 GPa using helium as a hydrostatic pressure-transferring medium. It is found that the quantum effects, which determine the difference between the ratio of the Raman scattering frequencies in the {sup 12}C and {sup 13}C diamonds and the classical ratio (1.0408), increase to 30 GPa and then decrease. Thus, inversion in the sign of the quantum contribution to the physical properties of diamond during compression is detected. Our data suggest that the maximum possible difference between the bulk moduli of the {sup 12}C and {sup 13}C diamonds is 0.15%. The investigation of the isotopically mixed {sup 12.5}C diamond shows that the effective mass, which determines the Raman frequency, decreases during compression from 12.38 au at normal pressure to 12.33 au at 73 GPa.
This article describes the development of hollow cathode ion lasers and their use in constructing an ultraviolet micro-Raman spectrograph with native fluorescence imaging capability.
The search for macroscopic quantum effects, including superfluidity, in molecular hydrogen is mostly focused on its parahydrogen (p-H 2 ) nuclear spin modification because of weaker intermolecular interaction compared to orthohydrogen (o-H 2 ), both modifications being bosonic. In this work, mixed clusters of o-H 2 and p-H 2 containing similar to 10(4) molecules are prepared by supersonic expansion with helium and studied by vibrational coherent anti-Stokes Raman scattering (CARS) spectroscopy. At similar experimental conditions the neat p-H 2 clusters avoid freezing and remain fluid at 1-2 K, which is predicted to be the realm of their superfluid behavior [Phys. Rev. Lett. 101, 205301 (2008)]. Dependence of the vibrational frequencies and intensities of the main CARS peaks due to o-H 2 and p-H 2 versus the ratio of the o-H 2 and p-H 2 concentrations in the expanding gas suggests that o-H 2 and p-H 2 molecules are uniformly mixed in the interior of the clusters. A weak spectral feature at 4157 cm -1 that appears independent of the concentration ratio is assigned to the outer shell of the clusters enriched with p-H 2 molecules. Although the phase of the mixed clusters could not be unambiguously identified, the shift of the vibrational frequencies with respect to the bulk solid is consistent with the liquid state of the clusters.
The displacement reaction of AgNO{sub 3} and copper metal is an effective and economical way to fabricate Ag-Cu surface enhanced Raman scattering (SERS) substrates. Aqueous solutions of AgNO{sub 3} are usually used for substrate preparation. In this work, a new method for Ag-Cu SERS substrate preparation is proposed, which uses an ethanol solution rather than an aqueous AgNO{sub 3} solution. Analysis of the surface morphologies of sample substrates by field emission scanning electron microscopy (FESEM) showed that the silver nanoparticles prepared by this new method were more regular than those prepared in the traditional aqueous solution. The SERS spectra of Rhodamine 6G (R6G) adsorbed on these Ag-Cu substrates were then investigated and compared. It was found that the Ag-Cu substrates prepared by this method provide significant improvements in Raman signal sensitivity and large-area uniformity. The enhancement factor of this new substrate is about 330 times higher than that prepared using an aqueous AgNO{sub 3} solution under identical experimental conditions. It was also found that 70% of the original sensitivity of the substrate remains after 15 days of exposure to air.
The overall objective of this project is to optics procurement and instrumental setup completed in Robert Lascola’s laboratory. An Ondax THz-Raman probe was installed in order to obtain Raman terahertz spectra of commercially available Zeolites.
This paper reports on the characterization and preliminary comparison of gold nanoparticles of differing surface modification and shape when used as extrinsic Raman labels (ERLs) in high-sensitivity heterogeneous immunoassays based on surface enhanced Raman scattering (SERS). ERLs are gold nanoparticles coated with an adlayer of an intrinsically strong Raman scatterer, followed by a coating of a molecular recognition element (e.g., antibody). Three types of ERLs, all with a nominal size of {approx}30 nm, were fabricated by using spherical citrate-capped gold nanoparticles (sp-cit-Au NPs), spherical CTAB-capped gold nanoparticles (sp-CTAB-Au NPs), or cube-like CTAB-capped gold nanoparticles (cu-CTAB-Au NPs) as cores. The performance of these particles was assessed via a sandwich immunoassay for human IgG in phosphate buffered saline. The ERLs fabricated with sp-CTAB-Au NPs as cores proved to be more than 50 times more sensitive than those with sp-cit-Au NPs as cores; the same comparison showed that the ERLs with cu-CTAB-Au NPs as cores were close to 200 times more sensitive. Coupled with small differences in levels of nonspecific adsorption, these sensitivities translated to a limit of detection (LOD) of 94, 2.3, and 0.28 ng/mL, respectively, for the detection of human IgG in the case of sp-cit-Au NPs, sp-CTAB-Au NPs, and cu-CTAB-Au NPs. The LOD of the cu-CTAB-Au NPs is therefore {approx}340 times below that for the sp-cit-Au NPs. Potential applications of these labels to bioassays are briefly discussed.
This paper describes experimental remote sensing of subsurface water temperature using the Raman spectroscopic technique. By the use of a pulsed laser and range gating detection techniques, Raman scattering is analyzed as a function of depth in a radar-like echo mode, and thus subsurface profiles of temperature and transmission are obtained. Experiments are described in which Raman data using polarization spectroscopy has been obtained from a ship as a function of depth in ocean water near Grand Bahama Island. A spectral temperature accuracy of + or - 1 C has been obtained from this data in the first two optical attenuation lengths. Raman data obtained from ocean water using the NASA airborne oceanographic lidar is also presented.
We have measured Raman spectra of carbonate, silicate, and hydrous silicate and sulfate minerals, our new remote-pulsed Raman system, indicating that it can be used to analyze the minerals on planetary surfaces to a distance of 10 to 66 meters. Additional information is contained in the original extended abstract.
Graphical abstract: - Highlights: • The sample is the typical dendritic crystal structure. • The phase transition of AlN dendritic crystal is researched. • The Raman signal of rock salt AlN is observed under high pressure. • Grüneisen parameters and phase transition criterion are discussed. - Abstract: AlN dendritic crystal was synthesized by the direct current arc discharge apparatus. X-ray diffraction (XRD) patterns indicated that the sample is hexagonal AlN and preferentially grown along the a-axis direction. Scanning electron microscopy (SEM) and Transmission electron microscopy (TEM) images reveal that the product mainly consists of micron AlN dendritic crystal. In situ high pressure Raman spectra of AlN dendritic crystal has been measured in the pressure ranged from ambient pressure to 32.97 GPa at room temperature by using diamond anvil cell. According to the Raman scattering results, the phase transition from the wurtzite to rock salt was found at about 20.73 GPa by the appearance of a new Raman signal. Above 20.73 GPa, a new Raman signal due to disorder-activated Raman scattering in the rock salt phase was observed. In addition, the pressure coefficients, phase transition criterion, and mode Grüneisen parameters of AlN dendritic crystal, which could be different from that of other AlN, are carefully discussed.
No abstract prepared.
Understanding the evolution of chemical decomposition—at the molecular level—in shock-compressed insensitive high explosive (IHE) single crystals is an important need. Toward this goal, time-resolved Raman spectra were measured in 1,1-diamino-2,2-dinitroethene (FOX-7) single crystals shock compressed to stresses above 20 GPa. At 22 GPa and higher stresses, the Raman peak intensities were significantly reduced, showing the onset and extent of chemical changes. At 33 GPa, no Raman peaks were observed, suggesting complete decomposition of FOX-7. The 22 GPa onset from Raman data is in marked contrast to the much higher (32 GPa) onset determined previously from wave profile measurements—showing the significantly greater sensitivity of Raman measurements for gaining insight into shock-induced molecular-level changes in IHE single crystals. The close match between the complete loss of Raman peaks at 33 GPa and the 32 GPa reaction threshold determined from continuum data makes a good case that the two results are related and they reflect significant energy release due to decomposition.
Not Available
No abstract prepared.
No abstract prepared.
The high spin to low spin transition of siderite is studied by simultaneous X-ray emission and X-ray Raman scattering spectroscopy.