Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Practice Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

WE-A-210-01: Overview of Methods and Accreditation Updates

This presentation will focus on the present role of ultrasound medical physics in clinical practices. The first part of the presentation will provide an overview of ultrasound QC methodologies and testing procedures. A brief review of ultrasound phantoms utilized in these testing procedures will be presented. The second part of the presentation will summarize ultrasound imaging technical standards and professional guidelines by American College of Radiology (ACR), American Institute of Ultrasound in Medicine (AIUM), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC). The current accreditation requirements by ACR and AIUM for ultrasound practices will be described and the practical aspects of implementing QC programs to be compliant with these requirements will be discussed. Learning Objectives: Achieve familiarity with common ultrasound QC test methods and ultrasound phantoms. Understand the coverage of the existing testing standards and professional guidelines on diagnostic ultrasound imaging. Learn what a medical physicist needs to know about ultrasound program accreditation and be able to implement ultrasound QC programs accordingly.

60 APPLIED LIFE SCIENCES↗

Development of Performance Acceptance Test Guidelines for Large Commercial Parabolic Trough Solar Fields: Preprint

Prior to commercial operation, large solar systems in utility-size power plants need to pass a performance acceptance test conducted by the EPC contractor or owners. In lieu of the present absence of engineering code developed for this purpose, NREL has undertaken the development of interim guidelines to provide recommendations for test procedures that can yield results of a high level ofaccuracy consistent with good engineering knowledge and practice. The fundamental differences between acceptance of a solar power plant and a conventional fossil-fired plant are the transient nature of the energy source and the necessity to utilize an analytical performance model in the acceptance process. These factors bring into play the need to establish methods to measure steady stateperformance, potential impacts of transient processes, comparison to performance model results, and the possible requirement to test, or model, multi-day performance within the scope of the acceptance test procedure. The power block and BOP are not within the boundaries of this guideline. The current guideline is restricted to the solar thermal performance of parabolic trough systems and hasbeen critiqued by a broad range of stakeholders in CSP development and technology.

14 SOLAR ENERGY↗

Expanding standards in viromics: in silico evaluation of dsDNA viral genome identification, classification, and auxiliary metabolic gene curation

Viruses influence global patterns of microbial diversity and nutrient cycles. Though viral metagenomics (viromics), specifically targeting dsDNA viruses, has been critical for revealing viral roles across diverse ecosystems, its analyses differ in many ways from those used for microbes. To date, viromics benchmarking has covered read pre-processing, assembly, relative abundance, read mapping thresholds and diversity estimation, but other steps would benefit from benchmarking and standardization. Here we use in silico-generated datasets and an extensive literature survey to evaluate and highlight how dataset composition (i.e., viromes vs bulk metagenomes) and assembly fragmentation impact (i) viral contig identification tool, (ii) virus taxonomic classification, and (iii) identification and curation of auxiliary metabolic genes (AMGs). The in silico benchmarking of five commonly used virus identification tools show that gene-content-based tools consistently performed well for long (≥3 kbp) contigs, while k -mer- and blast-based tools were uniquely able to detect viruses from short (≤3 kbp) contigs. Notably, however, the performance increase of k -mer- and blast-based tools for short contigs was obtained at the cost of increased false positives (sometimes up to ~5% for virome and ~75% bulk samples), particularly when eukaryotic or mobile genetic element sequences were included in the test datasets. Furthermore, for viral classification, variously sized genome fragments were assessed using gene-sharing network analytics to quantify drop-offs in taxonomic assignments, which revealed correct assignations ranging from ~95% (whole genomes) down to ~80% (3 kbp sized genome fragments). A similar trend was also observed for other viral classification tools such as VPF-class, ViPTree and VIRIDIC, suggesting that caution is warranted when classifying short genome fragments and not full genomes. Finally, we highlight how fragmented assemblies can lead to erroneous identification of AMGs and outline a best-practices workflow to curate candidate AMGs in viral genomes assembled from metagenomes. Together, these benchmarking experiments and annotation guidelines should aid researchers seeking to best detect, classify, and characterize the myriad viruses ‘hidden’ in diverse sequence datasets.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of the technology required to develop photovoltaic power system for large scale national energy applications

A technical assessment of a program to develop photovoltaic power system technology for large-scale national energy applications was made by analyzing and judging the alternative candidate photovoltaic systems and development tasks. A program plan was constructed based on achieving the 10 year objective of a program to establish the practicability of large-scale terrestrial power installations using photovoltaic conversion arrays costing less than $0.50/peak W. Guidelines for the tasks of a 5 year program were derived from a set of 5 year objectives deduced from the 10 year objective. This report indicates the need for an early emphasis on the development of the single-crystal Si photovoltaic system for commercial utilization; a production goal of 5 x 10 to the 8th power peak W/year of $0.50 cells was projected for the year 1985. The developments of other photovoltaic conversion systems were assigned to longer range development roles. The status of the technology developments and the applicability of solar arrays in particular power installations, ranging from houses to central power plants, was scheduled to be verified in a series of demonstration projects. The budget recommended for the first 5 year phase of the program is $268.5M.

Lutwack, R.↗

Integrating Human Factors into Crew Exploration Vehicle Design

With NASA's new Vision for Exploration to send humans beyond Earth orbit, it is critical to consider the human as a system that demands early and continuous user involvement, and an iterative prototype/test/redesign process. Addressing human-system interface issues early on can be very cost effective even cost reducing when performed early in the design and development cycle. To achieve this goal within Crew Exploration Vehicle (CEV) Project Office, human engineering (HE) team is formed. Key tasks are to apply HE requirements and guidelines to hardware/software, and provide HE design, analysis and evaluation of crew interfaces. Initial activities included many practice-orientated evaluations using low-fidelity CEV mock-ups. What follows is a description of such evaluations that focused on a HE requirement regarding Net Habitable Volume (NHV). NHV is defined as the total remaining pressurized volume available to on-orbit crew after accounting for the loss of volume due to deployed hardware and structural inefficiencies which decrease functional volume. The goal of the NHV evaluations was to develop requirements providing sufficient CEV NHV for crewmembers to live and perform tasks in support of mission goals. Efforts included development of a standard NHV calculation method using computer models and physical mockups, and crew/ stakeholder evaluations. Nine stakeholders and ten crewmembers participated in the unsuited evaluations. Six crewmembers also participated in a suited evaluation. The mock-up was outfitted with volumetric representation of sub-systems such as seats, and stowage bags. Thirteen scenarios were developed to represent mission/crew tasks and considered to be primary volume drivers (e.g., suit donning) for the CEV. Unsuited evaluations included a structured walkthrough of these tasks. Suited evaluations included timed donning of the existing launch and entry suit to simulate a contingency scenario followed by doffing/ stowing of the suits. All mockup evaluations were videotaped. Structured questionnaires were used to document user interface issues and volume impacts of layout configuration. Computer model and physical measures of the NHV agreed within 1 percent. This included measurement of the gross habitable volume, subtraction of intrusive volumes, and other non-habitable spaces. Calculation method developed was validated as a standard means of measuring NHV, and was recommended as a verification method for the NHV requirements. Evaluations confirmed that there was adequate volume for unsuited scenarios and suit donning/ doffing activity. Seats, suit design stowage and waste hygiene system noted to be critical volume drivers. The low-fidelity mock-up evaluations along with human modeling analysis generated discussions that will lead to high-level systems requirements and human-centered design decisions. This approach allowed HE requirements and operational concepts to evolve in parallel with engineering system concepts and design requirements. As the CEV design matures, these evaluations will continue and help with design decisions, and assessment, verification and validation of HE requirements.

Whitmore, Mihriban↗

Design, Qualification, and On Orbit Performance of the CALIPSO Aerosol Lidar Transmitter

The laser transmitter for the CALIPSO aerosol lidar mission has been operating on orbit as planned since June 2006. This document discusses the optical and laser system design and qualification process that led to this success. Space-qualifiable laser design guidelines included the use of mature laser technologies, the use of alignment sensitive resonator designs, the development and practice of stringent contamination control procedures, the operation of all optical components at appropriately derated levels, and the proper budgeting for the space-qualification of the electronics and software.

Hovis, Floyd E.↗

National Medical Care System May Impede Fostering of True Specialization of Radiation Oncologists: Study Based on Structure Survey in Japan

Purpose: To evaluate the actual work environment of radiation oncologists (ROs) in Japan in terms of working pattern, patient load, and quality of cancer care based on the relative time spent on patient care. Methods and Materials: In 2008, the Japanese Society of Therapeutic Radiology and Oncology produced a questionnaire for a national structure survey of radiation oncology in 2007. Data for full-time ROs were crosschecked with data for part-time ROs by using their identification data. Data of 954 ROs were analyzed. The relative practice index for patients was calculated as the relative value of care time per patient on the basis of Japanese Blue Book guidelines (200 patients per RO). Results: The working patterns of RO varied widely among facility categories. ROs working mainly at university hospitals treated 189.2 patients per year on average, with those working in university hospitals and their affiliated facilities treating 249.1 and those working in university hospitals only treating 144.0 patients per year on average. The corresponding data were 256.6 for cancer centers and 176.6 for other facilities. Geographically, the mean annual number of patients per RO per quarter was significantly associated with population size, varying from 143.1 to 203.4 (p < 0.0001). There were also significant differences in the average practice index for patients by ROs working mainly in university hospitals between those in main and affiliated facilities (1.07 vs 0.71: p < 0.0001). Conclusions: ROs working in university hospitals and their affiliated facilities treated more patients than the other ROs. In terms of patient care time only, the quality of cancer care in affiliated facilities might be worse than that in university hospitals. Under the current national medical system, working patterns of ROs of academic facilities in Japan appear to be problematic for fostering true specialization of radiation oncologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the Development of Shell Buckling Knockdown Factors for Stiffened Metallic Launch Vehicle Cylinders

From the 1920s to the early 1970s, many shell buckling experiments were conducted in an effort to understand the complex buckling behavior exhibited by thin-walled cylindrical shells, to provide data to correlate with new shell stability theories, and provide design guidelines. Typically, the experiments yielded buckling loads that were substantially lower than the corresponding analytical predictions, which were based on simplified linear bifurcation analyses of geometrically perfect shells with nominal dimensions and idealized boundary conditions. The seminal works by von Kármán and Tsien, by Donnell and Wan, and by Koiter identified small deviations from the idealized geometry of a shell, known as initial geometric imperfections, as a primary source of the discrepancy between corresponding analytical predictions and experimental results. However, the computational tools and capabilities at that time could not perform the nonlinear analyses needed to assess the effects of these imperfections on the buckling behavior of thin-walled shells. Thus, buckling design allowables were determined by establishing lower bounds to test data. Specifically, empirical design factors, that have become known as knockdown factors, were determined and were to be used in conjunction with linear bifurcation analyses for simply supported shells; that is, these empirical factors were used to "knock down" the value of the unconservative simplified analytical prediction. This approach to shell buckling design has proved satisfactory for most design purposes and remains prominent in industry practice, as evidenced by the extensive use of the NASA space vehicle design criteria and recommendations. Unfortunately, the current design guidelines have not been updated since they were first published in the late 1960s and may not be able to take full advantage of modern materials, precision manufacturing processes, and new structural concepts.

Hilburger, Mark W.↗

Use of EORTC Target Definition Guidelines for Dose-Intensified Salvage Radiation Therapy for Recurrent Prostate Cancer: Results of the Quality Assurance Program of the Randomized Trial SAKK 09/10

Purpose: Different international target volume delineation guidelines exist and different treatment techniques are available for salvage radiation therapy (RT) for recurrent prostate cancer, but less is known regarding their respective applicability in clinical practice. Methods and Materials: A randomized phase III trial testing 64 Gy vs 70 Gy salvage RT was accompanied by an intense quality assurance program including a site-specific and study-specific questionnaire and a dummy run (DR). Target volume delineation was performed according to the European Organisation for the Research and Treatment of Cancer guidelines, and a DR-based treatment plan was established for 70 Gy. Major and minor protocol deviations were noted, interobserver agreement of delineated target contours was assessed, and dose-volume histogram (DVH) parameters of different treatment techniques were compared. Results: Thirty European centers participated, 43% of which were using 3-dimensional conformal RT (3D-CRT), with the remaining centers using intensity modulated RT (IMRT) or volumetric modulated arc technique (VMAT). The first submitted version of the DR contained major deviations in 21 of 30 (70%) centers, mostly caused by inappropriately defined or lack of prostate bed (PB). All but 5 centers completed the DR successfully with their second submitted version. The interobserver agreement of the PB was moderate and was improved by the DR review, as indicated by an increased κ value (0.59 vs 0.55), mean sensitivity (0.64 vs 0.58), volume of total agreement (3.9 vs 3.3 cm{sup 3}), and decrease in the union volume (79.3 vs 84.2 cm{sup 3}). Rectal and bladder wall DVH parameters of IMRT and VMAT vs 3D-CRT plans were not significantly different. Conclusions: The interobserver agreement of PB delineation was moderate but was improved by the DR. Major deviations could be identified for the majority of centers. The DR has improved the acquaintance of the participating centers with the trial protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standardization and best practices in single-cell testing for liquid alkaline water electrolysis

The increasing demand for efficient and sustainable hydrogen production has driven significant advancements in water electrolysis technologies. Among these, liquid alkaline water electrolysis (LAWE) stands out for its cost-effectiveness and scalability. This manuscript establishes best practices and standardized testing procedures for single-cell LAWE, focusing on the use of nickel foam as both anode and cathode substrates, while incorporating catalysts such as nickel-iron layered double hydroxide (NiFe-LDH) as the anode material and nickel-molybdenum on carbon (NiMo/C) as the cathode material. By providing detailed guidelines on material preparation, cell assembly, and performance evaluation, this work offers a comprehensive framework to improve reproducibility and ensure consistency. The results demonstrate that applying these best practices minimizes variability across different laboratories and experimental setups, laying the groundwork for more robust comparisons and accelerating progress in LAWE research.

08 HYDROGEN↗

Proteomics Goes to Court: A Statistical Foundation for Forensic Toxin/Organism Identification Using Bottom-Up Proteomics

Bottom-up proteomics is increasingly being used to characterize unknown environmental, clinical, and forensic samples. Proteomics-based bacterial identification typically proceeds by tabulating peptide “hits” (i.e. confidently identified peptides) associated with the organisms in a database; those organisms with enough hits are declared present in the sample. This approach has proven successful in laboratory studies, however, important research gaps remain. First, the common-practice reliance on unique peptides for identification is susceptible to a phenomenon known as signal erosion. Second, no general guidelines are available for determining how many hits are needed to make a confident identification. These gaps inhibit the transition of this approach to real-world samples where conditions vary and large databases may be needed. We propose statistical criteria for organism identification that applies regardless of sample quality or data analysis pipeline. These criteria are straightforward, producing a p-value on the result. We test the criteria on LC-MS/MS datasets representing 919 different bacterial and toxin datasets acquired with multiple data collection platforms. Results reveal a >95% correct species-level identification rate, demonstrating the effectiveness and robustness of proteomics-based organism/toxin identification.

Jarman, Kristin H.↗

Design and Commissioning Plan for a Laser Heater for FERMI@elettra

The purpose of a laser heater is to increase the electron beam uncorrelated energy spread as a way to control and ideally suppress the microbunching instability in the linac drive for x-rays FELs. We review the motivations for equipping FERMI with a laser heater and provide a specification for the basics parameters as well as a description of a practical layout including desired diagnostics provisions for both the electron and laser beams. We also outline some useful operational guidelines for commissioning.

43 PARTICLE ACCELERATORS↗

OVERFLOW Guidelines for Simulation of Supersonic Retropropulsion

General methods for obtaining satisfactory simulation accuracy across a range of supersonic retropropulsive flows are recommended using comparisons between OVERFLOW calculations and tests of two vehicles in the Langley Unitary Plan Wind Tunnel. Gridding and discretization, various measures of solution convergence, and turbulence modelling options are dicussed. While the presented guidelines were developed from OVERFLOW simulations in support of a particular test, the recommendations on numerical methods and gridding practices hold merit for simulations conducted CFD solvers in general.

CFD↗

Image Guided Radiation Therapy (IGRT) Practice Patterns and IGRT's Impact on Workflow and Treatment Planning: Results From a National Survey of American Society for Radiation Oncology Members

Purpose: To survey image guided radiation therapy (IGRT) practice patterns, as well as IGRT's impact on clinical workflow and planning treatment volumes (PTVs). Methods and Materials: A sample of 5979 treatment site–specific surveys was e-mailed to the membership of the American Society for Radiation Oncology (ASTRO), with questions pertaining to IGRT modality/frequency, PTV expansions, method of image verification, and perceived utility/value of IGRT. On-line image verification was defined as images obtained and reviewed by the physician before treatment. Off-line image verification was defined as images obtained before treatment and then reviewed by the physician before the next treatment. Results: Of 601 evaluable responses, 95% reported IGRT capabilities other than portal imaging. The majority (92%) used volumetric imaging (cone-beam CT [CBCT] or megavoltage CT), with volumetric imaging being the most commonly used modality for all sites except breast. The majority of respondents obtained daily CBCTs for head and neck intensity modulated radiation therapy (IMRT), lung 3-dimensional conformal radiation therapy or IMRT, anus or pelvis IMRT, prostate IMRT, and prostatic fossa IMRT. For all sites, on-line image verification was most frequently performed during the first few fractions only. No association was seen between IGRT frequency or CBCT utilization and clinical treatment volume to PTV expansions. Of the 208 academic radiation oncologists who reported working with residents, only 41% reported trainee involvement in IGRT verification processes. Conclusion: Consensus guidelines, further evidence-based approaches for PTV margin selection, and greater resident involvement are needed for standardized use of IGRT practices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Complete Evaluation on Advanced Reactor Machine Learning Subversion Attacks (Final)

Navigating through the world of Artificial Intelligence (AI) in nuclear reactors and their Instrumentation and Control (I&C) systems demands a careful, deliberate journey. AI’s capability to manage massive datasets and streamline control systems has indeed carved out a significant role in various sectors, including nuclear energy. However, while AI, and particularly Large Language Models (LLMs), bring a lot to the table in terms of operational efficiency and anomaly detection, they also expose the sector to a new breed of cybersecurity threats, like Inference Attacks, Adversarial Attacks, and Trojan Attacks. This guide is designed to be a straightforward manual, diving deep into the intertwining worlds of AI and cybersecurity within nuclear reactors, and tailoring insights for three crucial audiences: I&C Vendors/Developers, Nuclear Regulators, and Nuclear Reactor Operators and Cyber Defense Teams. (1) Section 2, directed at I&C Vendors/Developers, will provide a clear and focused look at several cybersecurity attacks, offering practical recommendations and detailed scenarios related to AI cybersecurity. This section isn’t just about identifying problems but also about giving solid, usable solutions. (2) Section 3, meant for Nuclear Regulators, gets straight to the point about regulations, policy suggestions, and guidelines that are needed to lay down a robust, secure, and ethical foundation for the application of AI in nuclear operations. The focus is on making sure that everything adheres to international standards and laws while being practicable and clear-cut. (3) Section 4, aimed at Nuclear Reactor Operators and Cyber Defense Teams, offers an exhaustive exploration and technical reports, with clear recommendations and scenario analyses vital to protect operational environments and guarantee the secure application of AI in nuclear reactor operations. The goal is simple: as we step into an era where AI becomes a fundamental element of our technological and energy infrastructures, this guide is here to act as a clear, direct handbook, ensuring that AI is implemented within the nuclear sector in a manner that is secure, responsible, and practical. It’s about striking a balance – optimizing the undeniable benefits offered by AI while securing and shielding against potential cyber threats as we move through this new and complex landscape.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Building America Top Innovations 2012: Attic Air Sealing Guidelines

This Building America Top Innovations profile describes the DOE-sponsored Guide to Attic Air Sealing by Building America research partner Building Science Corporation, which provides best practices for attic air sealing. The guide has had 21,000 views and 13,000 downloads since it was posted.

air sealing↗

The Importance of Imaging in Radiation Oncology for National Clinical Trials Network Protocols

Imaging is essential in successfully executing radiation therapy (RT) in oncology clinical trials. As technically sophisticated diagnostic imaging and RT were incorporated into trials, quality assurance in the National Clinical Trials Network groups entered a new era promoting image acquisition and review. Most trials involving RT require pre- and post-therapy imaging for target validation and outcome assessment. The increasing real-time (before and during therapy) imaging and RT object reviews are to ensure compliance with trial objectives. Objects easily transmit digitally for review from anywhere in the world. Physician interpretation of imaging and image application to RT treatment plans is essential for optimal trial execution. Imaging and RT data sets are used to credential RT sites to confirm investigator and institutional ability to meet trial target volume delineation and delivery requirements. Real-time imaging and RT object reviews can be performed multiple times during a trial to assess response to therapy and application of RT objects. This process has matured into an effective data management mechanism. When necessary, site and study investigators review objects together through web media technologies to ensure the patient is enrolled on the appropriate trial and the intended RT is planned and executed in a trial-compliant manner. Real-time imaging review makes sure: (1) the patient is entered and eligible for the trial, (2) the patient meets trial-specific adaptive therapy requirements, if applicable, and (3) the intended RT is according to trial guidelines. This review ensures the study population is uniform and the results are believable and can be applied to clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Waste disposal technology transfer matching requirement clusters for waste disposal facilities in China

Highlights: Black-Right-Pointing-Pointer We outline the differences of Chinese MSW characteristics from Western MSW. Black-Right-Pointing-Pointer We model the requirements of four clusters of plant owner/operators in China. Black-Right-Pointing-Pointer We examine the best technology fit for these requirements via a matrix. Black-Right-Pointing-Pointer Variance in waste input affects result more than training and costs. Black-Right-Pointing-Pointer For China technology adaptation and localisation could become push, not pull factors. - Abstract: Even though technology transfer has been part of development aid programmes for many decades, it has more often than not failed to come to fruition. One reason is the absence of simple guidelines or decision making tools that help operators or plant owners to decide on the most suitable technology to adopt. Practical suggestions for choosing the most suitable technology to combat a specific problem are hard to get and technology drawbacks are not sufficiently highlighted. Western counterparts in technology transfer or development projects often underestimate or don't sufficiently account for the high investment costs for the imported incineration plant; the differing nature of Chinese MSW; the need for trained manpower; and the need to treat flue gas, bunker leakage water, and ash, all of which contain highly toxic elements. This article sets out requirements for municipal solid waste disposal plant owner/operators in China as well as giving an attribute assessment for the prevalent waste disposal plant types in order to assist individual decision makers in their evaluation process for what plant type might be most suitable in a given situation. There is no 'best' plant for all needs and purposes, and requirement constellations rely on generalisations meaning they cannot be blindly applied, but an alignment of a type of plant to a type of owner or operator can realistically be achieved. To this end, a four-step approach is suggested and a technology matrix is set out to ease the choice of technology to transfer and avoid past errors. The four steps are (1) Identification of plant owner/operator requirement clusters; (2) Determination of different municipal solid waste (MSW) treatment plant attributes; (3) Development of a matrix matching requirement clusters to plant attributes; (4) Application of Quality Function Deployment Method to aid in technology localisation. The technology transfer matrices thus derived show significant performance differences between the various technologies available. It is hoped that the resulting research can build a bridge between technology transfer research and waste disposal research in order to enhance the exchange of more sustainable solutions in future.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗