Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Trajectory Specification for Terminal Air Traffic: Pairwise Conflict Detection and Resolution

Trajectory Specification is the explicit bounding and control of aircraft trajectories such that the position at any point in time is constrained to a precisely defined volume of space. The bounding space is defined by cross-track, along-track, and vertical tolerances relative to a reference trajectory that specifies position as a function of time. The tolerances are dynamic and will be based on the aircraft navigation capabilities and the current traffic situation. Assuming conformance, Trajectory Specification can guarantee safe separation for an arbitrary period of time even in the event of an air traffic control (ATC) system or datalink failure; hence it can help to achieve the high level of safety and reliability needed for ATC automation. It can also reduce the reliance on tactical backup systems during normal operation. This paper applies it to the terminal area around a major airport and presents algorithms and software for detecting and resolving conflicts. A representative set of pairwise conflicts was generated, and a fast-time simulation was run on them. All conflicts were successfully resolved in real time, demonstrating the computational feasibility of the concept.

terminal area↗

GPS Estimates of Integrated Precipitable Water Aid Weather Forecasters

Global Positioning System (GPS) meteorology provides enhanced density, low-latency (30-min resolution), integrated precipitable water (IPW) estimates to NOAA NWS (National Oceanic and Atmospheric Adminis tration Nat ional Weather Service) Weather Forecast Offices (WFOs) to provide improved model and satellite data verification capability and more accurate forecasts of extreme weather such as flooding. An early activity of this project was to increase the number of stations contributing to the NOAA Earth System Research Laboratory (ESRL) GPS meteorology observing network in Southern California by about 27 stations. Following this, the Los Angeles/Oxnard and San Diego WFOs began using the enhanced GPS-based IPW measurements provided by ESRL in the 2012 and 2013 monsoon seasons. Forecasters found GPS IPW to be an effective tool in evaluating model performance, and in monitoring monsoon development between weather model runs for improved flood forecasting. GPS stations are multi-purpose, and routine processing for position solutions also yields estimates of tropospheric zenith delays, which can be converted into mm-accuracy PWV (precipitable water vapor) using in situ pressure and temperature measurements, the basis for GPS meteorology. NOAA ESRL has implemented this concept with a nationwide distribution of more than 300 "GPSMet" stations providing IPW estimates at sub-hourly resolution currently used in operational weather models in the U.S.

Moore, Angelyn W.↗

High-resolution oscillator strength measurements for the A(v') - X(0) bands of carbon monoxide with 11 less than or equal to v' less than or equal to 14

Band oscillator strengths (f-values) for four bands of the Fourth Positive system (A (1)Pi - Chi(sup 1) Sigma(+)) of CO have been determined from high-resolution (lambda/Delta lambda approximately equal to 150,000) absorption spectra. The bands, (14, 0) through (11, 0), are at wavelengths between 121 and 127 nm. Our f-values for the (11, 0) and (12, 0) bands support those of Chan, Cooper, & Brion (1993), which have been shown to be consistent with observations of CO in the clouds in the line of sight to zeta Oph. Our f-values for the (13, 0) and (14, 0) bands are the first directly measured values for these bands.

Smith, Peter L.↗

High resolution chronology of late Cretaceous-early Tertiary events determined from 21,000 yr orbital-climatic cycles in marine sediments

A number of South Atlantic sites cored by the Deep Sea Drilling Project (DSDP) recovered late Cretaceous and early Tertiary sediments with alternating light-dark, high-low carbonate content. The sedimentary oscillations were turned into time series by digitizing color photographs of core segments at a resolution of about 5 points/cm. Spectral analysis of these records indicates prominent periodicity at 25 to 35 cm in the Cretaceous intervals, and about 15 cm in the early Tertiary sediments. The absolute period of the cycles that is determined from paleomagnetic calibration at two sites is 20,000 to 25,000 yr, and almost certainly corresponds to the period of the earth's precessional cycle. These sequences therefore contain an internal chronometer to measure events across the K/T extinction boundary at this scale of resolution. The orbital metronome was used to address several related questions: the position of the K/T boundary within magnetic chron 29R, the fluxes of biogenic and detrital material to the deep sea immediately before and after the K/T event, the duration of the Sr anomaly, and the level of background climatic variability in the latest Cretaceous time. The carbonate/color cycles that were analyzed contain primary records of ocean carbonate productivity and chemistry, as evidenced by bioturbational mixing of adjacent beds and the weak lithification of the rhythmic sequences. It was concluded that sedimentary sequences that contain orbital cyclicity are capable of providing resolution of dramatic events in earth history with much greater precision than obtainable through radiometric methods. The data show no evidence for a gradual climatic deterioration prior to the K/T extinction event, and argue for a geologically rapid revolution at this horizon.

Herbert, Timothy D.↗

Terrestrial laser scanning data (Levels 0 and 1) for Pasoh, Malaysia, Sep 2024

This data package contains data from terrestrial laser scanning (TLS) at the Pasoh Forest Reserve, Malaysia. The Pasoh Forest Reserve is a facility of the Forest Research Institute Malaysia, and contains evergreen lowland dipterocarp forest. The Next-Generation Ecosystem Experiments Tropics (NGEE-Tropics) study areas at Pasoh were established to study how different species respond to climatic variation and soil water availability. Two study areas were chosen representing different topography and species. The TLS data archived here were collected to provide detailed, three-dimensional information about forest structure. Specifically, data were collected to allow tree-level characterization of woody structure and leaf area for 12 focal trees with FloraPulse and sap flux sensors, facilitating estimation of woody biomass and leaf area to allow upscaling of water content and transpiration data to the tree-level. Scan positions were not selected to provide consistent data for non-focal trees with the study areas. This data package contains the following data: - High-level files document further details of the campaign and data package: 1_CampaignSummary.csv provides details about the campaign and study site, 2_ScanAreasDetail.csv provides details about each separate scan area (groups of scans post-processed into a single point cloud), 3_TerrestrialLidarSensor.csv provides further technical details about the Riegl VZ-400i TLS sensor, TLS_CSV_dd.csv is a CSV Data Dictionary providing information about the fields in CSV files following the ESS-DIVE CSV File Formatting Guidelines Reporting Format, TLS_flmd.csv is a File Level Metadata file providing information about each file in the data package following the ESS-DIVE File Level Metadata Reporting Format, and README.txt is a text file describing the overall project and file structure. - Level 0 data are the raw data (.PROJ folders) as recorded by the Riegl VZ-400i TLS instrument before scan co-registration and post-processing with the Riegl's proprietary RiSCAN PRO software, which requires a license. - Level 1 data contain post-processed, co-registered data from each scan area. The "PointClouds" folder for each scan area contains a .las file with 1 cm resolution point cloud data exported from RiSCAN PRO. These are the main files likely to be of interest to most users and can be further processed with any software capable of manipulating .las files (e.g. Python, R CloudCompare). The "Project Information" folder contains log files from post-processing in RiSCAN PRO that may be of interest to users who want to see detailed records of post-processing, including all PDF reports generated by RiSCAN PRO. The "ScanPositions" folder contains information about the final position of all TLS scans, after post-processing, in multiple formats. The file ScanPositions_*.csv provides final geo-referenced scan positions, and the file SOP_backup_*.csv can be used in RiSCAN PRO to restore the co-registered scan positions if users wish to re-process raw data (Level 0 .PROJ folders) with RiSCAN PRO software (e.g., subsample to a different resolution, exclude a certain scan position, or apply different filters on reflectance or deviation values) without redoing time-consuming co-registration steps.

54 ENVIRONMENTAL SCIENCES↗

Fourier Transform Ultraviolet Spectroscopy of the A Pi-2(3/2) Direct Current X Pi-2(3/2) Transition of BrO

The first spectra of the A (2)Pi(sub 3/2) from X (2)Pi(sub 3/2) electronic transition of BrO using Fourier transform ultraviolet spectroscopy are obtained. Broadband vibrational spectra acquired at 298 +/- 2 K and 228 +/- 5 K, as well as high-resolution rotational spectra of the A from X 7,0 and 12,0 vibrational bands are presented. Wavenumber positions for the spectra are obtained with high accuracy, and cross section assignments are made, incorporating the existing literature. With 35 cm(exp -1) (0.40 nm) resolution the absolute cross section at the peak of the 7,0 band is determined to be (1.58 +/- 0.12) x 10(exp -17) sq cm/molecule at 298 +/- 2 K and (1.97 +/- 0.15) x 10(exp -17) sq cm/molecule at 228 +/- 5 K. BrO dissociation energies are determined with a graphical Birge-Sponer technique, using Le Roy-Bernstein theory to place an upper limit on the extrapolation. From the ground-state dissociation energy, D(sub o)" = 231.0 +/- 1.7 kJ/mol, the heat of formation of BrO(g) is calculated, del(sub f)H(0 K) = 133.7 +/- 1.7 kJ/mol and del(sub f)H(298.15 K) = 126.2 +/- 1.7 kJ/mol. Cross sections for the high-resolution 7,0 and 12,0 rotational peaks are the first to be reported. The band structures are modeled, and improved band origins, rotational constants, centrifugal distortion constants, and linewidths are determined. In particular, J-dependent linewidths and lifetimes are observed for the both the 7,0 and 12,0 bands.

Wilmouth, David M.↗

Algebraic discrete quantum harmonic oscillator with dynamic resolution scaling

We develop an algebraic formulation for the discrete quantum harmonic oscillator (DQHO) from the Hamiltonian for two, coupled QHOs and provide a physical picture for the Kravchuk function eigenstates of the oscillator. The familiar $\mathfrak{su}(2)$ structure of the coupled QHO Hamiltonian divides its spectrum into sets corresponding to the DQHO at different resolutions. In addition to energy ladder operators, the formulation allows for the introduction of resolution ladder operators connecting all DQHOs with different resolutions, thus enabling the dynamic scaling of the resolution of finite degree-of-freedom quantum simulations. The coherent state of the DQHO is constructed, and its expected position is proven to oscillate as a classical harmonic oscillator. The DQHO coherent state recovers that of the quantum harmonic oscillator at large resolution.

97 MATHEMATICS AND COMPUTING↗

Performance of position-sensitive resistive silicon detectors in the Forward Array Using Silicon Technology (FAUST)

The silicon telescopes of the Forward Array Using Silicon Technology (FAUST) have been recently upgraded with silicon detectors which use resistive charge-splitting to measure the position of charged particles. This is in addition to the measurement of the total energy that these charged particles deposit in the detector. The upgrade results in increased angular resolution with a much smaller number of signals than silicon strip detectors with similar resolution. Here, a novel method of calibration has been used to demonstrate the efficacy of these position-sensitive detectors, and the detectors have been used in a commissioning experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Picometer-Precision Atomic Position Tracking through Electron Microscopy

The modern aberration-corrected scanning electron microscopes have successfully achieved direct visualization of atomic columns with sub-angstrom resolution. With this significant progress, advanced image quantification and analysis is still at its early stages. In this work, we present the complete pathway for the metrology of atomic resolution STEM images. This includes: 1) tips for acquiring high-quality STEM images; 2) denoising and drift-correction for enhancing measurement accuracy; 3) obtaining initial atom positions; 4) indexing the atoms based on unit cell vectors; 4) quantifying the atom column positions with either 2D-gaussian single peak fitting or 5) multi-peak fitting routines for slightly overlapping atomic columns; 6) quantification of lattice distortion/strain within the crystal structures or at the defects/interfaces where the lattice periodicity is disrupted, and 7) some common methods to visualize and present the analysis. Furthermore, a simple self-developed free MATLAB app (EASY-STEM) with a graphical user interface (GUI) will be introduced that can help with the analysis of STEM images without the need for writing dedicated analysis code or software. The advanced data analysis methods presented here can be applied for the local quantification of defect relaxations, local structural distortions, local phase transformations, and non-centrosymmetry in a wide range of materials.

47 OTHER INSTRUMENTATION↗

Design and Characterization of an Extremely-Sensitive, Large-Volume Gamma-Ray Spectrometer for Environmental Samples

A large volume gamma spectrometer was designed and constructed to analyze foodstuffs and environmental samples having low radionuclide concentrations. This system uses eight 11-cm × 42.5-cm × 5.5-cm NaI(Tl) detectors, chosen due to their relatively high sensitivity and availability and arranged in an octagonal configuration. The sensitive volume of the system is ~28 cm in diameter and ~42 cm deep. Shielding consists of an 86-cm × 86-cm square, 64-cm-tall lead brick enclosure with 18-cm-thick lead walls lined by 0.3-cm-thick copper plates. An aluminum top was machined to suspend the detectors within this shield. The shielding reduces background counts by 72% at 100 keV and 42% at 1,000 keV. The positional variability in sensitivity of the well was determined by both simulation and experiment. A 2.1-L volume of nearly uniform sensitivity, varying less than 10%, exists in the well's center. Energy resolutions of 14.6% and 7.8% were measured for 241 Am and 137 Cs, respectively. Energy resolution shows a 0.2% variation for both 241 Am and 137 Cs as a function of position within all regions of the well’s central sensitive volume. Dead time was also determined to be less than 35% for all sources measured in the system, the largest of which had an activity of 1,760 kBq. Simulated results for various source geometries show higher counts for smaller samples, especially at lower energies due to less attenuation of low energy photons. In conclusion, minimum detectable activities were determined for all source energies used, less than 5.1 Bq kg -1 for reasonable background and sample counting times.

47 OTHER INSTRUMENTATION↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examining Cloud Feedback Components in the Simple Cloud-Resolving E3SM Atmosphere Model (SCREAM)

Cloud feedback remains the main source of uncertainty in climate sensitivity estimated by global climate models (GCMs), largely because subgrid cloud responses are parameterized in GCMs due to their coarse resolution. Here, this study examines cloud feedback in the global 3.25-km Simple Cloud-Resolving Energy Exascale Earth System Model (E3SM) Atmosphere Model (SCREAM 3 km) through a pair of 1-yr atmosphere-only simulations with control and +4-K sea surface temperature perturbations. SCREAM 3 km produces a positive cloud feedback that falls within but at the upper end of the range of Coupled Model Intercomparison Project phase 5 (CMIP5) and CMIP phase 6 (CMIP6) models and expert judgment. The positive cloud feedback arises from positive contributions from both high- and low-level clouds, with increases in high-cloud altitude and decreases in low-cloud amount and optical depth playing key roles. The stronger-than-CMIP-average feedback is mainly attributable to the high-cloud altitude feedback, owing to cloud tops rising nearly isothermally in SCREAM 3 km. The positive low-cloud amount feedback is weaker in SCREAM than in GCMs because estimated inversion strength (EIS) increases more dramatically with warming. A coarser 12-km resolution version of SCREAM exhibits a weaker positive cloud feedback than SCREAM 3 km, mainly because its low-cloud-radiative flux is more sensitive to EIS, leading to a stronger negative low-cloud amount feedback. With this process-level assessment of cloud feedback, this study reveals where SCREAM aligns with and diverges from conventional GCMs and expert assessment, providing insights to inform further model improvement and future expert assessment.

Cloud radiative effects↗

UWB Two-Cluster AOA Tracking Prototype System Design

This presentation discusses a design effort for a prototype ultra-wideband (UWB) tracking system that is currently under development at NASA Johnson Space Center (JSC). The system is being studied for use in tracking of lunar/Mars rovers during early exploration missions when satellite navigation systems are not available. The UWB technology is exploited to implement the tracking system due to its properties such as fine time resolution, low power spectral density and multipath immunity. A two cluster prototype design using commercially available UWB radios is employed to implement the Angle of Arrival (AOA) tracking methodology in this design effort. In order to increase the tracking range, low noise amplifiers (LNA) and high gain horns are used at the receiving sides. Field tests were conducted jointly with the Science and Crew Operation Utility Testbed (SCOUT) vehicle near the Meteor Crater in Arizona to test the tracking capability for a moving target in an operational environment. These tests demonstrate that the UWB tracking system can co-exist with other on-board radio frequency (RF) communication systems (such as Global Positioning System (GPS), video, voice and telemetry systems), and that a tracking resolution less than 1% of the range can be achieved.

Ngo, Phong H.↗

Latest Progress on the Gamma-Ray Imager/Polarimeter for Solar Flares (GRIPS)

We present the latest progress on building the balloon-borne Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument, including testing and calibration of the detectors and development of the imaging and aspect systems. A continental-US test flight is slated for fall 2012. GRIPS will provide a near-optimal combination of high-resolution imaging, spectroscopy, and polarimetry of solar-flare gamma-ray/hard X-ray emissions from approx.20. keV to > approx.10 MeV. The spectrometer/polarimeter consists of sixteen 3D position-sensitive germanium detectors (3D-GeDs), where each energy deposition is individually recorded with an energy resolution of a few keV FWHM and a spatial resolution to within <0.1 cu mm. Imaging is accomplished by a single multi-pitch rotating modulator (MPRM), a 2.5-cm thick tungsten-alloy grid with pitches that range quasi-continuously from 1 to 13 mm. With the MPRM situated 8 meters from the spectrometer, this instrument will provide excellent image quality and unparalleled angular resolution at gamma-ray energies (12.5 arcsec FWHM), sufficient to separate the 2.2 MeV footpoint sources for almost all flares. Polarimetry is accomplished by analyzing the anisotropy of reconstructed Compton scattering in the 3D-GeDs (i.e. as an active scatterer), with an estimated minimum detectable polarization of a few percent at 150-650 keV in an X-class flare. GRIPS will address questions relevant to particle acceleration and energy release that ha-.e been raised by recent solar flare observations, such as: What causes the spatial separation between energetic electron producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the accelerated electrons, and why do relativistic electron dominate in the corona? How does the composition of accelerated and ambient material vary with space and time, and why?

Shih, Albert Y.↗

High resolution imaging X-ray detector for astronomical measurements

The article describes the X-ray detector which will provide second-of-arc images for the HEAO-B X-ray observatory. The instrument uses microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. Position determination is accomplished by electronic interpolation between the coarse grid wires. The detector provides the arrival time and position of each event which occurs within its field of view. Measurements of the spatial resolution (15 microns), temporal resolution (7.8 microsec), image distortion (less than 10 microns), uniformity of efficiency (less than plus or minus 10%), dark counting rate (0.2 cts/sq cm/s), and quantum efficiency (10% at 1.54 keV) of this detector are described. A summary of the procedure which was found useful during the initial turn-on of microchannel plates is given.

Henry, J. P.↗

Massively distributed fiber strain sensing using Brillouin lasing

Brillouin based distributed fiber sensors present a unique set of characteristics amongst fiber sensing architectures. They are able to measure absolute strain and temperature over long distances, with high spatial resolution, and very large dynamic range in off-the-shelf fiber. However, Brillouin sensors traditionally provide only modest sensitivity due to the weak dependence of the Brillouin frequency on strain and the high signal to noise ratio required to identify the resonance’s peak frequency to within a small fraction of its linewidth. Recently, we introduced a technique which substantially improves the precision of Brillouin fiber sensors by exciting a series of lasing modes in a fiber loop cavity that experience Brillouin amplification at discrete locations in the fiber. The narrow-linewidth and high intensity of the lasing modes enabled ultra-low noise Brillouin sensors with large dynamic range. However, our initial demonstration was only modestly distributed: measuring strain at 40, non-contiguous positions along a 400 m fiber. In this work, we greatly extend this methodology to enable fully distributed sensing at 1000 contiguous locations along 3.5 km of fiber—an order of magnitude increase in sensor count and range. This highly-multiplexed Brillouin fiber laser sensor provides a strain noise as low as 34 nɛ/√Hz and we analyze the limiting factors in this approach.

47 OTHER INSTRUMENTATION↗

Unsupervised multimodal fusion of in-process sensor data for advanced manufacturing process monitoring

Effective monitoring of manufacturing processes is crucial for maintaining product quality and operational efficiency. Modern manufacturing environments often generate vast amounts of complementary multimodal data, including visual imagery from various perspectives and resolutions, hyperspectral data, and machine health monitoring information such as actuator positions, accelerometer readings, and temperature measurements. However, fusing and interpreting this complex, high-dimensional data presents significant challenges, particularly when labeled datasets are unavailable or impractical to obtain. This paper presents a novel approach to multimodal sensor data fusion in manufacturing processes, inspired by the Contrastive Language-Image Pre-training (CLIP) model. We leverage contrastive learning techniques to correlate different data modalities without the need for labeled data, overcoming limitations of traditional supervised machine learning methods in manufacturing contexts. Our proposed method demonstrates the ability to handle and learn encoders for five distinct modalities: visual imagery, audio signals, laser position (x and y coordinates), and laser power measurements. By compressing these high-dimensional datasets into low-dimensional representational spaces, our approach facilitates downstream tasks such as process control, anomaly detection, and quality assurance. The unsupervised nature of our method makes it broadly applicable across various manufacturing domains, where large volumes of unlabeled sensor data are common. We evaluate the effectiveness of our approach through a series of experiments, demonstrating its potential to enhance process monitoring capabilities in advanced manufacturing systems. This research contributes to the field of smart manufacturing by providing a flexible, scalable framework for multimodal data fusion that can adapt to diverse manufacturing environments and sensor configurations. The proposed method paves the way for more robust, data-driven decision-making in complex manufacturing processes.

Contrastive Learning↗

Dedicated beam position monitor pair for model-independent lattice characterization at NSLS-II

This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with bunch-by-bunch (B$\times$B) resolution, were recently installed in a section of the storage ring free of magnetic fields. The new BPM pair measured the beam, or bunch’s transverse Poincaré map precisely after the beam was excited. Linear one-turn-matrices (OTM) were then derived, and from these, the 4-dimensional coupled Twiss parameters were extracted at the locations of the BPM pair. By normalizing beam oscillation amplitudes with the Twiss parameters, the global action-variables were obtained. Additionally, these action-variables facilitated the measurement of the local Twiss parameters observed by other BPMs independent on lattice model. This method is general, and particularly useful in certain scenarios such as a round beam mode in a diffraction-limited light source ring. We applied it to assess both weakly and strongly coupled lattices at the NSLS-II ring. Through analysis of the strongly coupled lattice, the quadrupole tilt errors were estimated to be less than 400 μrad. Utilizing the BPMs’ B$\times$B resolution, for the first time we observed the variations of the linear lattice along a long bunch-train.

36 MATERIALS SCIENCE↗