Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Porous flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Chemical Sensors Based on IR Spectroscopy and Surface-Modified Waveguides

Sol-gel processing techniques have been used to apply thin porous films to the surfaces of planar infrared (IR) waveguides to produce widely useful chemical sensors. The thin- film coating serves to diminish the concentration of water and increase the concentration of the analyte in the region probed by the evanescent IR wave. These porous films are composed of silica, and therefore, conventional silica surface modification techniques can be used to give the surface a specific functional character. The sol-gel film was surface-modified to make the film highly hydrophobic. These sensors were shown to be capable of detecting non-polar organic analytes, such as benzonitrile, in aqueous solution with detection limits in the ppb range. Further, these porous sol-gel structures allow the analytes to diffuse into and out of the films rapidly, thus reaching equilibrium in less than ten seconds. These sensors are unique because of the fact that their operation is based on the measurement of an IR absorption spectrum. Thus, these sensors are able to identify the analytes as well as measure concentration with high sensitivity. These developments have been documented in previous reports and publications. Recently, we have also targeted detection of the polar organic molecules acetone and isopropanol in aqueous solution. Polar organics are widely used in industrial and chemical processes, hence it is of interest to monitor their presence in effluents or decontamination process flows. Although large improvements in detection limits were expected with non-polar organic molecules in aqueous solutions using very hydrophobic porous sol-gel films on silicon attenuated total reflectance (Si ATR) waveguides, it was not as clear what the detection enhancements might be for polar organic molecules. This report describes the use of modified sol-gel-coated Si ATR sensors for trace detection and quantitation of small polar organic molecules in aqueous solutions. The detection of both acetone and isopropanol molecules in aqueous solution has been previously reported for chalcogenide fiber optic sensors. The sol-gel film was produced using a mixture of ethyltriethoxysilane and tetraethoxysilane and the surface modification was carried out using trimethylchlorosilane. We have demonstrated that this film concentrates the target polar analytes from aqueous solution in the region probed by the evanescent wave to improve detection limits by as much as a factor of 450.

Lopez, Gabriel P.↗

The liquid-vapor transition in porous plug operation

The porous plug is a proven method for phase separation in superfluid helium dewars operating in zero gravity. The principal operating regimes have been identified in laboratory experiments on porous plugs. In this paper, a description of porous plug operation is given, and a new explanation is presented for the observed transition in the mass flow rate vs Delta-P characteristic. Theoretical results are in qualitative agreement with experimental data.

Hendricks, John B.↗

Analyses of Control Surface Seal Tested in the Ames Arc Jet Tunnel (Panel Test Facility)

The contents include: 1) Rope Seal; 2) Improvements to porous medial simulation in CFD-ACE+; 3) Porous media heat transfer validation case-stead-state and transient flat plate; 4) Simulation of GRC cold flow seal test fixture; 5) Simulation of calibration plate in the Panel Test Facility (PTF); and 6) Simulation of rope seal test in the PTF. This paper is in viewgraph form.

Reich, Alton J.↗

Acoustic and Aero-Mixing Experimental Results for Fluid Shield Scale Model Nozzles

The principle objectives of this investigation are to evaluate the acoustic and aerodynamic characteristics of fluid shield nozzle concept and to assess Far 36, Stage 3 potential for fluid shield nozzle with Flade Cycle. Acoustic data for nine scale model nozzle configurations are obtained. The effects of simulated flight and geometric and aerothermodynamic flow variables on the acoustic behavior of the fluid shield are determined. The acoustic tests are aimed at studying the effect of: (1) shield thickness, (2) wrap angle, (3) mass flow and velocity ratios between shield and core streams at constant cycle specific thrust (i.e., mixed velocity), (4) porous plug, and (5) subsonic shield. Shadowgraphs of six nozzle configurations are obtained to understand the plume flowfield features. Static pressure data on suppressor chutes in the core stream (shielded and unshielded) sides and on plug surface are acquired to determine the impact of fluid shield on base drag of the 36-chute suppressor nozzle and the thrust augmentation due to the plug, respectively.

Salikuddin, M.↗

Lightweight porous plastic plaque

The porosity and platability of various materials were investigated to determine a suitable substrate for nickel-plated electrodes. Immersion, ultrasonics, and flow-through plating techniques were tried using nonproprietary formulations, and proprietary phosphide and boride baths. Modifications to the selected material include variations in formulation and treatment, carbon loading to increase conductivity, and the incorporation of a grid. Problems to be solved relate to determining conductivities and porosities as a function of amount of nickel plated on the plastics; loading; charge and discharge curves of electrodes at different current densities; cell performance; and long-term degradation of electrodes.

Reid, M.↗

(abstract) Wide Dynamic Range Porous Plug and Vent Line for SIRTF

The most recent approach to the Space Infrared Telescope Facility (SIRTF) uses a new design concept in which the telescope is launched warm and subsequently cooled to operating temperture on orbit. At launch the cryostat is at 2 K and the telescope is at room temperature. Cooldown of the telescope will be accomplished initially through radiation to space. Final cooldown to the 5.5 K operating temperature is done with helium vapor. Initially the helium flow on orbit will be 10 to 20 times larger than required for steady-state operation. The vent line and the liquid-vapor phase separator (porous plug) therefore must accomodate a large dynamic operational range. For ground testing of IR instruments, the required temperature is 1.5 K. The helium tank temperature for both ground testing and space operations thus needs to be 1.4 K. We will present a discussion of the requirements, a conceptual design, and initial laboratory test results with candidate porous plugs and associated instrumentation. A discussion of possible connections to the design of Gravity Probe-B cryostat will also be presented.

infrared space helium cryostat↗

Diffusion Time-Scale of Porous Pressure-Sensitive Paint

Pressure-sensitive paint (PSP) is an optical pressure sensor that utilizes the oxygen quenching of luminescence. PSP measurements in unsteady aerodynamic flows require fast time response of the paint. There are two characteristic time-scales that are related to the time response of PSP. One is the luminescent lifetime representing an intrinsic physical limit for the achievable temporal resolution of PSP. Another is the time-scale of oxygen diffusion across the PSP layer. When the time-scale of oxygen diffusion is much larger than the luminescent lifetime, the time response of PSP is controlled by oxygen diffusion. In a thin homogenous polymer layer where diffusion is Fickian, the oxygen concentration 1021 can be described by the diffusion equation in one-dimension.

Liu, Tianshu↗

Group-kinetic theory of turbulence

The two phases are governed by two coupled systems of Navier-Stokes equations. The couplings are nonlinear. These equations describe the microdynamical state of turbulence, and are transformed into a master equation. By scaling, a kinetic hierarchy is generated in the form of groups, representing the spectral evolution, the diffusivity and the relaxation. The loss of memory in formulating the relaxation yields the closure. The network of sub-distributions that participates in the relaxation is simulated by a self-consistent porous medium, so that the average effect on the diffusivity is to make it approach equilibrium. The kinetic equation of turbulence is derived. The method of moments reverts it to the continuum. The equation of spectral evolution is obtained and the transport properties are calculated. In inertia turbulence, the Kolmogoroff law for weak coupling and the spectrum for the strong coupling are found. As the fluid analog, the nonlinear Schrodinger equation has a driving force in the form of emission of solitons by velocity fluctuations, and is used to describe the microdynamical state of turbulence. In order for the emission together with the modulation to participate in the transport processes, the non-homogeneous Schrodinger equation is transformed into a homogeneous master equation. By group-scaling, the master equation is decomposed into a system of transport equations, replacing the Bogoliubov system of equations of many-particle distributions. It is in the relaxation that the memory is lost when the ensemble of higher-order distributions is simulated by an effective porous medium. The closure is thus found. The kinetic equation is derived and transformed into the equation of spectral flow.

Tchen, C. M.↗

Low-Cost Phased Microphone Array Design for Moderate-Scale Aeroacoustics Tests

A new wall-mounted phased microphone array was designed, built, and calibrated for testing in closed or open test section wind tunnels. Two configurations were evaluated - one with microphone plate flush with the tunnel surface and the other with microphone plate recessed behind a porous screen. The arrays were successfully operated to Mach number of 0.4 and were calibrated using an in-flow speaker source during a recent study at the AEDC NFAC 40- by 80-Ft Wind Tunnel at NASA Ames.

Horne, Clifton↗

Some Design Considerations for Two-Dimensional, Mixed-Compression Inlets for Mach 2.5 to 3.5.

A computational design study was performed to explore design factors for two-dimensional, mixed-compression inlets designed for cruise conditions at Mach 2.5, 2.75, 3.0, 3.25, and 3.5 and their influence on the aerodynamic performance of the inlets. The design factors included the split of external and internal compression, capture aspect ratio, throat section and subsonic diffuser geometry, and location and rates of porous bleed regions. The performance of the inlet was measured by the total pressure recovery, cowl wave drag, bleed flow rates, and total pressure distortion at the engine face. The results provide useful information for the design of inlets for future supersonic aircraft.

Supersonic Inlet↗

An investigation of a free jet at low Reynolds numbers

A comparison of the measured and calculated flow field properties of a nozzle of unusual design which was used to produce an incompressible, low Reynolds number jet is presented. The nozzle is essentially a porous metal plate which covers the end of a pipe. Results are presented for nozzle Reynolds numbers from 50 to 1000 with velocities of 100 or 200 ft/sec. The nozzle produces a uniform velocity profile at nozzle Reynolds numbers well below those at which conventional contoured nozzles are completely filled with the boundary layer. A jet mixing analysis based on the boundary layer equations accurately predicted the flow field over the entire range of Reynolds numbers tested.

Greene, G. C.↗

Distributed Pore Chemistry in Porous Organic Polymers

A method for making a biocompatible polymer article using a uniform atomic oxygen treatment is disclosed. The substrate may be subsequently optionally grated with a compatibilizing compound. Compatibilizing compounds may include proteins, phosphorylcholine groups, platelet adhesion preventing polymers, albumin adhesion promoters, and the like. The compatibilized substrate may also have a living cell layer adhered thereto. The atomic oxygen is preferably produced by a flowing afterglow microwave discharge. wherein the substrate resides in a sidearm out of the plasma. Also, methods for culturing cells for various purposes using the various membranes are disclosed as well. Also disclosed are porous organic polymers having a distributed pore chemistry (DPC) comprising hydrophilic and hydrophobic regions. and a method for making the DPC by exposing the polymer to atomic oxygen wherein the rate of hydrophilization is greater than the rate of mass loss.

Koontz, Steven L.↗

Cell-Culture Reactor Having a Porous Organic Polymer Membrane

A method for making a biocompatible polymer article using a uniform atomic oxygen treatment is disclosed. The substrate may be subsequently optionally grated with a compatibilizing compound. Compatibilizing compounds may include proteins, phosphory1choline groups, platelet adhesion preventing polymers, albumin adhesion promoters, and the like. The compatibilized substrate may also have a living cell layer adhered thereto. The atomic oxygen is preferably produced by a flowing afterglow microwave discharge, wherein the substrate resides in a sidearm out of the plasma. Also, methods for culturing cells for various purposes using the various membranes are disclosed as well. Also disclosed are porous organic polymers having a distributed pore chemistry (DPC) comprising hydrophilic and hydrophobic regions, and a method for making the DPC by exposing the polymer to atomic oxygen wherein the rate of hydrophilization is greater than the rate of mass loss.

Koontz, Steven L.↗

Distributed Pore Chemistry in Porous Organic Polymers

A method for making a biocompatible polymer article using a uniform atomic oxygen treatment is disclosed. The sub-strate may be subsequently optionally grated with a compatibilizing compound. Compatibilizing compounds may include proteins, phosphorylcholine groups, platelet adhesion preventing polymers, albumin adhesion promoters, and the like. The compatibilized substrate may also have a living cell layer adhered thereto. The atomic oxygen is preferably produced by a flowing afterglow microwave discharge, wherein the substrate resides in a sidearm out of the plasma. Also, methods for culturing cells for various purposes using the various membranes are disclosed as well. Also disclosed are porous organic polymers having a distributed pore chemistry (DPC) comprising hydrophilic and hydrophobic region, and a method for making the DPC by exposing the polymer to atomic oxygen wherein the rate of hydrophilization is greater than the rate of mass loss.

Koontz, Steven L.↗

Unique gear design provides self-lubrication

Composite gear configuration provides a reliable automatic means for replenishing gear mechanism lubricants that dissipate in the harsh environment of space. The center or hub section of the gear consists of a porous, oil impregnated material, and the outer or toothed section has radially drilled passages to cause the oil to gradually flow to the gear teeth surface.

Winiarski, F. J.↗

Amorphous and porous ices in cometary nuclei

The heat flux into the cometary nucleus before and after perihelion and its influence on the nucleus are discussed. The surface temperature and the associated rate of evaporation are lower than usually calculated, and the effect is strongly dependent on the porosity of the nucleus. The surface temperature reaches a maximum after perihelion, in agreement with statistical studies of comae and tails. Delayed heating of the CO2-rich inclusions deep in the nucleus leads to outbursts and splittings as far as 9 AU after perihelion, also in agreement with observation. At sufficiently high temperatures, heat transport in porous cometary nuclei is controlled by vapor diffusion. The presence of CO2 vapor in the pores significantly increases the heat flow in mixed nuclei at temperatures above 140-150 C. Closed pores move up the radial thermal gradient so that the outside layer of a cometary nucleus should become denser.

Smoluchowski, R.↗

Performance test of a laboratory pump liquid transfer based on the fountain effect

A laboratory scale pump has been tested in detail in order to determine the flow characteristics of a heater-activated all-metal thermomechanical pump (fountain effect pump, FEP). The emphasis is on the functional dependence of the fountain pressure difference versus mass throughput. A modified Vote et al. (1971) power law approximation is employed for a simplified description of the flow rate as a function of the driving force. Flow rates of up to 10 liters/(hr/sq cm) have been obtained despite a large nominal pore size of the porous plug of 2 microns (filtration rating) used for the FEP.

Chen, W. E. W.↗

Kinetics and transport at AMTEC electrodes. I - The interfacial impedance model

Mixed mass-transport and kinetic control of sodium ion reduction at porous inert electrodes on sodium beta-double-prime alumina solid electrolyte (BASE) ceramic in a high-temperature electrochemical cell has been observed and modeled. The high ionic conductivity of BASE and the reversibility of the liquid sodium/BASE anodic half-cell led to assignment of potential-dependent (nonohmic) resistances to kinetic and mass-transport processes associated with the porous electrode. The morphology of these electrodes and typical sodium gas pressures are consistent with Knudsen, or free-molecular, flow through the electrode.

Williams, R. M.↗