Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase change”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Combined visualisation of cavitation and vortical structures in a real-size optical diesel injector

A high-speed flow visualisation set-up comprising of combined diffuse backlight illumination (DBI) and schlieren imaging has been developed to illustrate the highly transient, two-phase flow arising in a real-size optical fuel injector. The different illumination nature of the two techniques, diffuse and parallel light respectively, allows for the capturing of refractive-index gradients due to the presence of both interfaces and density gradients within the orifice. Hence, the onset of cavitation and secondary-flow motion within the sac and injector hole can be concurrently visualised. Experiments were conducted utilising a diesel injector fitted with a single-hole transparent tip (ECN spray D) at injection pressures of 700–900 bar and ambient pressures in the range of 1–20 bar. High-speed DBI images obtained at 100,000 fps revealed that the orifice, due to its tapered layout, is mildly cavitating with relatively constant cavity sheets arising mainly in regions of manufacturing imperfections. Nevertheless, schlieren images obtained at the same frame rate demonstrated that a multitude of vortices with short lifetimes arise at different scales in the sac and nozzle regions during the entire duration of the injection cycle but the vortices do not necessarily result in phase change. The magnitude and exact location of coherent vortical structures have a measurable influence on the dynamics of the spray emerging downstream the injector outlet, leading to distinct differences in the variation of its cone angle depending on the injection and ambient pressures examined.

42 ENGINEERING↗

Fluid Dynamics Effects on Microstructure Prediction in Single-Laser Tracks for Additive Manufacturing of IN625

Single-track laser fusion were simulated using a heat-transfer-solidification-only (HTS) model and its extension with fluid dynamics (HTS_FD) model using a parallel open-source code, which included laminar fluid dynamics, flat-free surface of the molten alloy, heat transfer, phase-change, evaporation, and surface tension phenomena. The results illustrate that the fluid dynamics affects the solidification and ensuing microstructure. For the HTS_FD simulations, thermal gradient, G was found to exhibit a maximum at the extremity of the solidified pool ( i.e. , at the free surface), while for HTS simulations, G exhibited a maximum around the entire edge of the solidified pool. HTS_FD simulations predicted a wider range of cooling rates than the HTS simulations, exhibited an increased spread in the solidification speed, V variation within the melt-pool with respect to the HTS model results. Primary dendrite arm spacing (PDAS) were evaluated based on power law correlations and marginal stability theory models using the ( G , V ) from HTS and HTS_FD simulations to quantify the effect of the fluid dynamics on the microstructure. At low-laser powers and low-scan speeds, the PDAS obtained with the fluid dynamics model (HTS_FD) was larger by more than 30 pct with respect to the PDAS calculated with the simple HTS model. A new PDAS correlation, i.e. , \( \lambda_{1} \left[ {\mu {\text{m}}} \right] = 832\;G\left[ {\text{K/m}} \right]^{ - 0.5} V\left[ {\text{m/s}} \right]^{ - 0.25} \) , which uses the ( G , V ) results from the HTS_FD model was developed and validated against experimental results.

36 MATERIALS SCIENCE↗

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

Transforming nanoscale VO 2 (B) into a scalable sodium-ion electrode

The intermittent nature of renewable energies requires highly reliable grid-level energy storage approaches. A critical consideration in developing this technology is the areal capacity which determines battery performance and influences the cost of battery technology. Of related importance is finding new ways of developing scalable electrodes. In recent years, three-dimensional (3D) printing of conductive scaffolds has emerged as an alternative to overcome the scalability limitations of commercial tape cast electrodes. The research carried out in the current study demonstrates a successful scalability pathway for nanoscale VO 2 (B), a desirable cathode for sodium-ion batteries which has a nano-flower morphology with a crystallite size < 20 nm. By electrodepositing VO 2 (B) onto a graphene aerogel scaffold, we were able to achieve mass loading of over 100 mg·cm −2 and still possess an areal capacity of 10 mAh·cm −2 at a current density of 5 mA·cm −2 . Moreover, after 1000 cycles, these electrodes retained 75% to 80% of their initial capacity. Even at high loading levels, the electrodeposited VO 2 (B) exhibits pseudocapacitive material signatures such as a box-like voltammetry response, linear galvanostatic response, and no phase change upon lithiation. The scalability of the VO 2 (B) electrode is demonstrated in a series of experiments which show the areal capacity to scale upon increase in both mass loading and electrode thickness, with only small changes in specific capacity. Furthermore, this study establishes that nanoscale materials can be scaled up to achieve thick electrodes without compromising their electrochemical properties.

additive manufacturing↗

Thermo-hydro-mechanical analysis of subsurface ice-based thermal energy storage

Ice-based thermal energy storage systems are widely utilized for cooling and managing peak electrical demand globally, offering daily or weekly storage capabilities for both individual homes and larger office buildings. However, scaling these systems for district-level cooling or integrating them with renewable energy sources presents challenges, especially in accommodating larger volumes and addressing seasonal storage requirements in densely populated urban areas. This paper proposes a novel solution by evaluating subsurface ice-based thermal energy storage, in which the underground is subjected to seasonal freeze/thaw cycles. However, these cycles may influence ground behavior, affecting pore pressure and inducing ground movement. To systematically investigate these challenges, we enhance the TOUGH-FLAC simulator by integrating water/ice phase change capabilities and updating the effective stress–strain constitutive relation. Both modifications are validated against analytical solutions or experimental data. Through numerical simulations spanning a decade with ten seasonal freeze/thaw cycles, we evaluate the performance and long-term stability of a generic subsurface ice-based thermal energy storage system, considering factors such as ground permeability, freezing pipe spacing, freeze/thaw damage, and glycol solution temperature. The simulations indicate that ice formation induces pore pressure variations that drive seasonal surface heave and settlement, controlled by ground permeability, pipe spacing, and glycol solution temperature, along with tensile and localized shear deformation around freeze pipes. This highlights the need for accurate ground property characterization and geomechanical analysis for subsurface ice-based thermal energy storage.

Ground freezing↗

A novel shallow bore ground heat exchanger for ground source heat pump applications—Model development and validation

A novel ground heat exchanger design, the Underground Thermal Battery (UTB), was proposed as a low-cost alternative to the conventional vertical bore ground heat exchanger (VBGHE) for the application of ground source heat pumps (GSHPs). The UTB is designed to be installed in a shallow borehole (less than 6 m deep) and thus could cost much less than the conventional VBGHE, which usually is installed in vertical bores 60 m deep. By utilizing natural convection of water and phase change materials, the UTB tempers its temperature change in response to thermal loads, which helps improve the efficiency of GSHPs. A one-dimensional (1D) model of the UTB has been developed and validated with the measured performance data of a small-scale UTB, as well as the simulation results of a more detailed three dimensional (3D) numerical model, which accounts for both heat transfer and fluid dynamics in the UTB. Further, this 1D model is computationally much more efficient than the 3D model and thus can simulate the annual performance of the UTB with acceptable computation time. The 1D model has been used to evaluate the performance of the UTB so that it can be compared with the conventional VBGHE.

42 ENGINEERING↗

Ammonia-based chemisorption heat pumps for cold-climate heating applications: A comprehensive review

This paper reviews the state of the art of chemisorption heat pumps that use ammonia as the refrigerant for cold-climate heating applications. In such a system, ammonia vapor is adsorbed by the solid salt through reversible chemisorption reactions, and the thermal effect of the reaction and ammonia phase change is used to extract heat from a cold environment and supply heat to a warm environment. With the high latent heat and low boiling point of ammonia as a low-temperature refrigerant and the high sorption capacity of ammonia-based chemisorption reactions, chemisorption heat pumps have the potential to produce high-efficiency heating, particularly for cold climates. This review first briefly introduces the basics of ammonia-based chemisorption heat pump systems. Then, the latest development of sorbent materials, including ammoniate salts and heat-conductive porous matrix materials, are summarized with the focus on low-temperature heating conditions. The design of system components, as well as cycle configurations, in the literature are summarized. This review concludes with highlights of recent developments on these topics and suggestions of areas for further research.

42 ENGINEERING↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric and sensitivity analysis of a PCM-integrated wall for optimal thermal load modulation in lightweight buildings

Load modulation in buildings is becoming increasingly important due to growing disparity in energy demand during peak and off-peak hours. Integrating phase change material (PCM) in building envelopes and using a controlled precooling strategy can provide substantial thermal load modulation; however, it may greatly increase the total energy use. Previous studies have employed PCM in building envelopes primarily for energy savings and, to some extent, peak load shedding and shifting. However, the load modulation capacity of a PCM-integrated envelope has not been well explored in the literature. In this study, we perform an extensive parametric and sensitivity analysis on PCM-integrated lightweight building walls and examine the combinatory effects of various PCM parameters on thermal load modulation and wall-related heat gains in buildings. Using numerical simulations, we investigate eight PCM parameters: PCM location in the wall, transition temperature, thickness, latent heat, transition range, density, specific heat, and thermal conductivity. Here, we evaluate their impact and relative importance to achieve maximum load modulation in buildings without compromising occupants’ thermal comfort or total energy use. The results show that the optimized PCM proposed in this study can completely invert the transient heat gain profile of the wall, providing up to 70% reduction of wall-related heat gain during peak hours without a major increase in the cumulative heat gain.

42 ENGINEERING↗

Three influential factors on colloidal nanoparticle deposition for heat conduction enhancement in 3D chip stacks

Thermal management is one of the major challenges facing the development of three-dimensional (3D) chip stacks. Recently, experimental studies have shown that neck-based thermal structure (NTS) between chip layers formed by drying of colloidal suspension in cavity filled with micro-size particles can improve the vertical heat conduction threefold. However, a deep understanding of the mechanisms of neck formation and its influence on heat conduction is still lacking. In this paper, we numerically study the effects of three parameters, i.e., initial nanoparticle concentration, drying temperature and chip surface wettability on neck formation between filler particles and on the resulting heat conduction of the NTS. With increasing nanoparticle concentration, the size and number of necks increase, resulting in an increased effective thermal conductivity (ETC) of NTS. The drying temperature is found to have only little influence on the ETC of resultant NTS, while the neck size and spatial distribution become more uniform at higher drying temperature. When reducing the wettability of the top and bottom surfaces of the cavity, the necks shrink in size until completing evacuating at the top and bottom layers, while the size of the necks between filler particles in the middle height of the cavity expands slowly. In consequence, the ETC of NTS drops at an increasing rate. Being able to reveal the underlying multiple mechanisms of two-phase flow, phase change and heat transport, the current numerical study suggests optimal values for the deposition process, with initial nanoparticle concentration over 0.8%, a drying temperature of 60°C and a uniform contact angle of 30° for practical production of NTS.

3D chip stacks↗

Empirical validation and comparison of methodologies to simulate micro and macro-encapsulated PCMs in the building envelope

Thermal Energy Storage (TES) has the potential to shift peak electricity demand. Passive TES is usually implemented in building envelope as micro and macro encapsulated phase change materials (PCM) to shift electric energy demand and therefore requires careful heat transfer analysis. Whole building energy modelling with simplified heat transfer analysis has become extremely important for designers, architects, engineers, and researchers to predict energy performance of buildings. It is important to validate PCM modelling algorithms used in building energy programs to quantify their error and prove their capacity to model different PCM encapsulation types. This study uses data from a microencapsulated PCM and two macroencapsulated PCMs (Bio based PCM and hydrate salts) tested in full-scale using the Advanced Multiscale Building Energy Research (AMBER) Lab located at the Colorado School of Mines and is used to validate a numerical algorithm written in MATLAB language. To approximate the heat transfer through a wall assembly with macroencapsulated PCM pouches, several modelling techniques that can reduce 3D heat transfer characteristics to 1D are explored in this research. A parallel path heat transfer modelling approach is found to give the closest agreement with the experimental data for the pouched PCMs in building envelope applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Storage Integrated into Air-Source Heat Pumps to Leverage Building Electrification: A Systematic Literature Review

Air-source heat pumps (ASHPs) can support a decarbonized economy by replacing combustion appliances in homes and electrifying heating systems in buildings. However, ASHPs have not seen significant adoption primarily due to deteriorated performance under cold conditions - at very low temperatures they require auxiliary resistance heating to meet the heating demand and defrost the evaporator. The additional heat lowers the system efficiency. Thermal energy storage (TES) is a candidate technology to help overcome some of these issues. This paper presents a systematic literature review to map the existing research on the integration of TES into ASHPs. Our review of 59 publications indicates that thermal storage increases the ASHP coefficient of performance by 27% on average, albeit with higher initial cost compared to conventional fossil-fueled heating systems. Phase change materials may be ideal to be integrated with ASHPs due to their high energy density and compact design, but only a few publications address TES sizing and design. First and Second Laws of Thermodynamics are widely used to create metrics to assess ASHP-TES integration, and only recently have cost and environmental impact been explored. This literature review suggests that more comprehensive metrics are needed to evaluate the potential benefits of ASHP-TES systems.

air source heat pump↗

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Parametric optimization of PCM-enhanced underground thermal energy storage for buildings in moderate cold climates

This study presents a novel underground thermal energy storage (UTES) system designed for space heating in buildings located in moderate cold climates. The proposed UTES features a borehole with a depth of 25 ft. (7.62 m) and a diameter of 3 ft. (0.91 m), containing two helical pipe loops-one for discharge fluid and another for recharge fluid-and a thermally enhanced phase change material (PCM) layer that provides high energy storage capacity. The system requires daily thermal recharging using a low-grade heat source for a few hours and delivers continuous heating at a nearly constant discharge rate without significant performance degradation over a 24-h period. This study demonstrates that the optimized UTES, when recharged with hot fluid at an inlet temperature of 40 degrees C for 6 h daily, can provide a continuous heat discharge rate of approximately 2.9 kW for 24 h or 3.4 kW if operated under a shorter discharge period of 15 h (17:00-08:00). With a round-trip efficiency of 72-97%, the proposed UTES offers an efficient and reliable solution for short- and long-duration thermal energy storage technology, making it a promising technology for cold climates.

15 GEOTHERMAL ENERGY↗

Biphasic solvents for post-combustion CO 2 capture from natural gas flue Gas

Fossil fuel fired power plants are generally expected to remain one of the most significant global sources of electricity for decades to come. Consequently, carbon management technologies are needed to reduce or eliminate ongoing emissions from these sources. Amongst the many techniques for carbon capture, aqueous amine-based absorbents (monoethanolamine, MEA, in particular) are, presently, considered the leading technology for post-combustion CO 2 point-source capture. These technologies are nevertheless limited by their high capital and regeneration energy costs. Biphasic solvents have been identified as an attractive alternative to traditional MEA based absorbents due to their potential energy savings. Thus far, however, the research on biphasic solvents has largely focused on their performance in coal flue gas while more dilute natural gas flue gas applications have received relatively little attention. Here, this work examines the performances of two novel biphasic solvent blends, diethylenetriamine (DETA) and triethylenetetramine (TETA), in CO 2 capture from a natural gas flue gas simulant. Across several regeneration tests, both solvents achieved considerable energy savings over the benchmark MEA solution. Specifically, the energy consumption per mol CO 2 recovered for the DETA-based and TETA-based solvents was 46 % and 35 % less than that of the benchmark MEA solution, respectively. Molecular dynamics simulations were also performed to gain a deeper understanding of the phase separation phenomena that occur as a consequence of CO 2 absorption. These simulations indicated that phase change was driven by the strong interaction between the absorption products and water, while the degree of separation depended on the CO 2 loading.

Biphasic solvents↗

The hydration, microstructure, and mechanical properties of vaterite calcined clay cement (VC 3 )

Limestone (calcite) calcined clay cement (LC 3 ) is a promising low-CO 2 binder, but the low activity of calcite cannot compensate the reduction in clinker factor, resulting in low one-day strength and limiting its broad applications. As recent carbon capture and utilization technologies allow scalable production of vaterite, a more reactive CaCO 3 polymorph, we overcome the challenge by introducing vaterite calcined clay cement (VC 3 ), inspired by the vaterite-calcite phase change. In the present study, VC 3 exhibits higher compressive strengths and faster hydration than LC 3 . Compared to hydrated LC 3 , hydrated VC 3 exhibits increased amount of hemi- and mono-carboaluminate formation and decreased amount of strätlingite formation. With gypsum adjustment, the 1-day strength of VC 3 is higher than that of pure cement reference. Finally, VC 3 , a low-CO 2 binder, presents great potential as a host of the metastable CaCO 3 for carbon storage and utilization and as an enabler of carbon capture at gigaton scales.

36 MATERIALS SCIENCE↗

Dielectric and magnetic properties of microwave-absorbing FeAl x O y catalysts fabricated via solution combustion synthesis

Iron-based alumina (FeAl x O y ) nanocomposites are microwave-absorbers and catalysts, which makes them promising for emerging microwave-assisted thermocatalytic technologies. Solution combustion synthesis (SCS) has been used to synthesize FeAl x O y powders, and prior work has demonstrated that adjusting SCS parameters significantly changes phase composition and specific surface area of the products. However, it is unclear how synthesis parameters affect their microwave-absorbing properties, which are essential for optimizing microwave-assisted technologies. To address this challenge, in the present work, twelve different FeAl x O y products were synthesized at different combinations of the SCS parameters such as two fuels (citric acid and glycine), two heating modes (hotplate and muffle furnace), and three Fe:Al molar ratios (2:1, 1:1, 1:2). Dielectric and magnetic properties of the products were characterized using a network analyzer and a vibrating sample magnetometer. Based on the measured permittivity and permeability, penetration depth and reflection loss were calculated as a function of frequency and bed thickness. The products were heated by microwaves at 2.45 GHz and then examined with X-ray diffraction (XRD) analysis. For all products, the magnetic saturation was lower than for bulk iron oxides because of the small crystallite size and aluminum substitution. The use of glycine induced high dielectric losses and enabled fast microwave-heating rates compared to citric acid. Higher Fe:Al ratio also led to higher dielectric and magnetic losses. With glycine fuel, SCS in a furnace induced larger penetration depth and lower microwave absorption than SCS on a hotplate. The minimization of reflected power was more sensitive to the thickness of the product bed than to the frequency of the electromagnetic field. Post-heating XRD analysis revealed different phase transformations in the FeAl x O y powders depending on the SCS parameters. As a result, an FeAl x O y material, synthesized via incipient wetness impregnation, lacked magnetic losses and did not heat well as compared to the SCS products.

Combustion synthesis↗