Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

PETSc/TAO Users Manual Revision 3.23

This manual describes the use of the Portable, Extensible Toolkit for Scientific Computation (PETSc) and the Toolkit for Advanced Optimization (TAO) for the numerical solution of partial differential equations (PDEs) and related problems on high-performance computers. PETSc/TAO is a suite of data structures and routines that provide the building blocks for implementing large-scale application codes on parallel (and serial) computers. PETSc uses the MPI standard for all distributed memory communication.

97 MATHEMATICS AND COMPUTING↗

PETSc/TAO Users Manual Revision 3.24

This manual describes the use of the Portable, Extensible Toolkit for Scientific Computation (PETSc) and the Toolkit for Advanced Optimization (TAO) for the numerical solution of partial differential equations (PDEs) and related problems on high-performance computers. PETSc/TAO is a suite of data structures and routines that provide the building blocks for implementing large-scale application codes on parallel (and serial) computers. PETSc uses the MPI standard for all distributed memory communication.

97 MATHEMATICS AND COMPUTING↗

PETSc/TAO Users Manual Revision 3.25

This manual describes the use of the Portable, Extensible Toolkit for Scientific Computation (PETSc) and the Toolkit for Advanced Optimization (TAO) for the numerical solution of partial differential equations (PDEs) and related problems on high-performance computers. PETSc/TAO is a suite of data structures and routines that provide the building blocks for implementing large-scale application codes on parallel (and serial) computers. PETSc uses the MPI standard for all distributed memory communication.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Exploiting Modern C++ for Portable Parallel Programming in Lattice QCD Applications

The evolution of ISO C++ standards increasingly serves the needs of scientific computing, offering potential benefits for developing portable applications. The recent revisions of C++ programming language, for instance, introduces a suite of algorithms capable of being executed on accelerators. Although this approach may not yield best performance, it can present a viable balance between code productivity and computational efficiency. In this report, we discuss the implementation of the HISQ operator utilizing a range of features from the C++17/20/23 standards and include an assessment of their performance.

Strelchenko, Alexei↗

Anomalous absorption of electromagnetic waves by 2D transition metal carbonitride Ti 3 CNT x (MXene)

Lightweight, ultrathin, and flexible electromagnetic interference (EMI) shielding materials are needed to protect electronic circuits and portable telecommunication devices and to eliminate cross-talk between devices and device components. Here, we show that a two-dimensional (2D) transition metal carbonitride, Ti 3 CNT x MXene, with a moderate electrical conductivity, provides a higher shielding effectiveness compared with more conductive Ti 3 C 2 T x or metal foils of the same thickness. This exceptional shielding performance of Ti 3 CNT x was achieved by thermal annealing and is attributed to an anomalously high absorption of electromagnetic waves in its layered, metamaterial-like structure. These results provide guidance for designing advanced EMI shielding materials but also highlight the need for exploring fundamental mechanisms behind interaction of electromagnetic waves with 2D materials.

Science & Technology - Other Topics↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Blood Plasma Self-Separation Technologies during the Self-Driven Flow in Microfluidic Platforms

Blood plasma is the most commonly used biofluid in disease diagnostic and biomedical analysis due to it contains various biomarkers. The majority of the blood plasma separation is still handled with centrifugation, which is off-chip and time-consuming. Therefore, in the Lab-on-a-chip (LOC) field, an effective microfluidic blood plasma separation platform attracts researchers’ attention globally. Blood plasma self-separation technologies are usually divided into two categories: active self-separation and passive self-separation. Passive self-separation technologies, in contrast with active self-separation, only rely on microchannel geometry, microfluidic phenomena and hydrodynamic forces. Passive self-separation devices are driven by the capillary flow, which is generated due to the characteristics of the surface of the channel and its interaction with the fluid. Comparing to the active plasma separation techniques, passive plasma separation methods are more considered in the microfluidic platform, owing to their ease of fabrication, portable, user-friendly features. We propose an extensive review of mechanisms of passive self-separation technologies and enumerate some experimental details and devices to exploit these effects. The performances, limitations and challenges of these technologies and devices are also compared and discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Non-destructive measurement and real-time monitoring of apple hardness during ultrasonic contact drying via portable NIR spectroscopy and machine learning

Portable near-infrared spectrometer in the spectral range of 900–1700 nm was evaluated for the first time to assess and monitor apple hardness in real-time during ultrasonic drying. Calibration models were developed using PLS and ANN, and their performances were evaluated by internal leave-one-out cross-validation and an external dataset. Several pre-treatments including standard normal variate (SNV), multiplicative scatter correction (MSC), Savitzky–Golay first and second derivatives were employed to examine the effects of spectral variations in hardness prediction. Seven important wavelengths were selected using weighted regression coefficients to develop a simple MLR model to facilitate the model interpretation and circumvent noise. The models using PLS, MLR, and ANN with selected wavelengths predicted the apple hardness with R 2 p of 0.91, 0.91, 0.95, and RMSEP of 14.78, 14.85, and 12.46 N, respectively. Finally, the results indicate that portable NIR spectrometers are quite promising for real-time monitoring of apple hardness during ultrasonic drying.

47 OTHER INSTRUMENTATION↗

Community Geothermal: Final Thermal Conductivity Test Report and Data Logs - Carbondale, CO

Provided here are a final thermal conductivity test report, a drilling log, and a heat rejection log from Carbondale, CO. Also attached is a report made before drilling, which contains predictions on the hydrogeologic conditions of the drill site. The forty-eight (48.9) hour in-situ thermal conductivity test was performed on the 28th through the 30th, of November 2023. The test was performed at the borehole drilled on November 16th through the 20th, at the 3rd Street Center at 520 S. 3rd, Street in Carbondale, Colorado. Testing was done with a certified Ewbank portable test unit.

15 GEOTHERMAL ENERGY↗

Single-pixel reconstructive mid-infrared micro-spectrometer

Miniaturized spectrometers in the mid-infrared (MIR) are critical in developing next-generation portable electronics for advanced sensing and analysis. The bulky gratings or detector/filter arrays in conventional micro-spectrometers set a physical limitation to their miniaturization. In this work, we demonstrate a single-pixel MIR micro-spectrometer that reconstructs the sample transmission spectrum by a spectrally dispersed light source instead of spatially grated light beams. The spectrally tunable MIR light source is realized based on the thermal emissivity engineered via the metal-insulator phase transition of vanadium dioxide (VO 2 ). We validate the performance by showing that the transmission spectrum of a magnesium fluoride (MgF 2 ) sample can be computationally reconstructed from sensor responses at varied light source temperatures. With potentially minimum footprint due to the array-free design, our work opens the possibility where compact MIR spectrometers are integrated into portable electronic systems for versatile applications.

47 OTHER INSTRUMENTATION↗

Oxygen Loss in Layered Oxide Cathodes for Li-Ion Batteries: Mechanisms, Effects, and Mitigation

Layered lithium transition metal oxides derived from LiMO 2 (M = Co, Ni, Mn, etc.) have been widely adopted as the cathodes of Li-ion batteries for portable electronics, electric vehicles, and energy storage. Oxygen loss in the layered oxides is one of the major factors leading to cycling-induced structural degradation and its associated fade in electrochemical performance. Herein, we review recent progress in understanding the phenomena of oxygen loss and the resulting structural degradation in layered oxide cathodes. We first present the major driving forces leading to the oxygen loss and then describe the associated structural degradation resulting from the oxygen loss. Here, we follow this analysis with a discussion of the kinetic pathways that enable oxygen loss, and then we address the resulting electrochemical fade. Finally, we review the possible approaches toward mitigating oxygen loss and the associated electrochemical fade as well as detail novel analytical methods for probing the oxygen loss.

36 MATERIALS SCIENCE↗

Scintillation light detection in polycrystalline diamond using single photon detectors

Here, this study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing distinct characteristics based on impurity content and crystallinity. Scintillation responses were assessed using Silicon Photomultipliers (SiPMs), demonstrating the capability of polycrystalline diamond powders to respond to alpha irradiation, albeit with reduced resolution compared to traditional scintillators. A prototype neutron detector was developed by combining diamond powder with neutron-sensitive 6 LiF, and its performance was evaluated through experimental testing and Geant4 simulations. The findings indicate that polycrystalline diamond-based detectors can achieve significant detection efficiency while remaining insensitive to gamma radiation, offering potential for portable neutron detection applications.

47 OTHER INSTRUMENTATION↗

Module-OT: A Turnkey Solution for Securing Energy Systems

The Modular Security Apparatus for Managing Distributed Cryptography for Command-and-Control Messages on Operational Technology Networks (Module-OT) is a flexible and lightweight solution for grid-edge devices focusing on end-to-end security. It is a bump- in- the-wire solution acting as a secure conduit for data between devices or systems across a network. It improves the cybersecurity posture of DER systems by providing authentication, authorization, and data integrity to secure DER communications. Additionally, it performs key management, provides data security through whitelisting Internet Protocol addresses and ports, blocks unauthorized connections, controls user access, and allows serial or Ethernet connections for added flexibility. The core software is portable to various Linux-based operating systems and is developed to be customized by the developer and researcher communities. Module-OT has been validated in the lab, has been demonstrated at a 500-KW PV-plus-storage site, and has been proven ready to secure operational technology devices. Its core functionality meets current standards, including validation procedures of the NIST Cryptographic Algorithm Validation Program (CAVP) and the Federal Information Processing Standard (FIPS 140-2). Because of its capability to provide an accessible and affordable option for stepping up security across modern energy systems, Module-OT can serve as an effective technological option to standardize cybersecurity moving forward.

cryptography↗

Inference-Engine v0.1.0

Given a pre-trained neural network, Inference-Engine performs maps network inputs to outputs by executing the forward pass through the provided network. Although the predominant programming language for machine-learning is Python, most high-performance computing (HPC) applications are written in Fortran, C, or C++. Inference-Engine aims to support HPC programs and is written in Fortran, a language with a large feature set supporting interoperability with C. This software exposes concurrency in a portable way by using standard language features that some modern Fortran compilers can exploit with various optimizations, including offloading computation to a Graphics Processing Unit (GPU). In particular, this software makes extensive use of Fortran's "do concurrent" parallel loop construct, implicitly parallel array statements, and pure procedures that can be invoked inside "do concurrent" blocks. Inference-Engine also supports dynamic choice of inference methods at runtime. Two current options include one method that uses Fortran's "dot_product" intrinsic function inside "do concurrent" blocks and another method that instead uses Fortran' "matmul" array intrinsic function. We plan to investigate automatic compiler offloading of "do concurrent" calculations to GPUs and compile-time substitution of optimized libraries such as the Basic Linear Algebra Library (BLAS) for "matmul" invocations. We also envision the potential for the choice of which method to use could happen at program launch based on in situ performance measurements on any given platform.

Rouson, Damian↗

Improved particle-flow event reconstruction with scalable neural networks for current and future particle detectors

Abstract Efficient and accurate algorithms are necessary to reconstruct particles in the highly granular detectors anticipated at the High-Luminosity Large Hadron Collider and the Future Circular Collider. We study scalable machine learning models for event reconstruction in electron-positron collisions based on a full detector simulation. Particle-flow reconstruction can be formulated as a supervised learning task using tracks and calorimeter clusters. We compare a graph neural network and kernel-based transformer and demonstrate that we can avoid quadratic operations while achieving realistic reconstruction. We show that hyperparameter tuning significantly improves the performance of the models. The best graph neural network model shows improvement in the jet transverse momentum resolution by up to 50% compared to the rule-based algorithm. The resulting model is portable across Nvidia, AMD and Habana hardware. Accurate and fast machine-learning based reconstruction can significantly improve future measurements at colliders.

Physics↗

Ultralightweight Power System for Human-Portable Linac-Based X-Ray Sources

Industrial human-portable X-ray sources are widely used by security, nuclear safeguard, and defense agencies. However, the employed sources have significant energy, dose, size, weight, and power (SWaP) limitations, greatly affecting their practical application. RF linear accelerators (linacs) can serve as a flexible, reliable, and robust type of X-ray source if they can match the size, weight, cost, and imaging performance requirements of conventional ones. One of the most critical elements affecting these parameters is the high-voltage pulsed power supply system or modulator, which can make the largest contribution to the total weight and dimensions of the accelerator. Here, in this article, we present the design and demonstration results of a novel ultra lightweight power system based on a 24-kV solid-state Marx modulator for a hand-portable 0.15–2.0-MeV Ku -band linac-based X-ray source.

47 OTHER INSTRUMENTATION↗

MFIX-Exa: Performance prediction of multiphase energy conversion devices

MFIX-Exa targets the high-fidelity CFD-DEM model in which particles are unresolved by the fluid grid (typically using a fluid mesh approximately twice the particle diameter) but discrete particle dynamics including collisions are resolved with a simple linear-spring dashpot model. The fluid field is solved with a modern low Mach number formation of a cell-centered, nodal-pressure approximate projection method using a Godunov scheme . Physics capabilities include: complex geometries via embedded boundaries (EBs), open and closed system ideal gas equations of state, species transport and heterogeneous chemi- cal reactions. MFIX-Exa is built on the AMReX software framework, the ECP Block-Structured Adaptive Mesh Refinement (AMR) Co-Design Center, which allows the code to be portable and performant.Further integration into the ECP ecosystem includes HYPRE linear solvers and Ascent for in situ visualization. Current project efforts focus on scaling up realistic simulations to the KPP of the challenge problem: NETs 50kW chemical looping reactor, shakedown and scaling on JSLE and OLCF TDS systems and reaching for any remaining performance improvements.

Musser, Jordan↗

Recent Advances in Rechargeable Aluminum-Ion Batteries and Considerations for Their Future Progress

Owing to their high theoretical capacity and reliable operational safety, nonaqueous rechargeable aluminum batteries (RABs) have emerged as a promising class of battery materials and been intensively studied in recent years; however, a lack of suitable, high-performing positive electrode materials, along with the need for air-sensitive and expensive ionic liquid electrolytes, has significantly hindered the practical use of RABs in large-scale applications. Therefore, we sought to carefully analyze positive electrode materials and the associated electrolytes that have been reported in these battery systems in order to stimulate the design of the next generation of high-performance and low-cost RABs. In this review, we have summarized the electrode materials that have been used in both nonaqueous and aqueous RAB systems and provided a rational classification based on the types of materials used and their respective structures. Additionally, we have reviewed electrolytes employed in RABs and have categorized them according to two main types of applications, either for fixed battery systems or for use in portable devices. Here, a systematic account of recent developments on RABs, with a focus on electrode materials, innovative perspectives, and impending research efforts on future RABs, has been included. Finally, a proposed liquid RAB system is discussed with the aim of solving issues regarding fast-charging and long operational lifetimes, followed by insights into solid RABs for use in both portable and multistructural RAB systems.

25 ENERGY STORAGE↗