Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems↗

Filter-Banks for Ultra-Wideband Communications, Sensing, and Localization

Recently, filterbank multi-carrier spread spectrum (FBMC-SS) has been proposed as a candidate waveform for ultrawideband (UWB) communications. It has been noted that FBMCSS is a perfect match to this application, leading to a trivial method of matching to the required spectral mask at different regions of the world. FBMC-SS also allows easy rejection of high-power interfering signals that may appear over different parts of the UWB spectral band. In this paper, we concentrate on the use of staggered multitone spread spectrum (SMT-SS) for UWB communications. SMT makes use of offset QAM modulation to transmit data symbols over narrowband, overlapping subcarrier bands. This form of FBMC-SS is well-suited to UWB communications because it has good spectral efficiency and a flat power spectral density (PSD), resulting in good utilization of the UWB spectral mask. Additionally, we explore new methods for multi-coding that result in higher bit rates than previous FBMCSS systems. Moreover, we study methods for equalizing the UWB multipath channel and cancelling narrowband interference. Excellent performance of the proposed methods are substantiated by presenting simulation results.

99 - GENERAL AND MISCELLANEOUS↗

SU-D-17A-03: 5D Respiratory Motion Model Based Iterative Reconstruction Method for 4D Cone-Beam CT

Purpose: The purpose of this work is to develop a new iterative reconstruction method for 4D cone-beam CT (CBCT) based on a published time-independent 5D respiratory motion model. The proposed method will offer a single high-resolution image at a user-selected breathing phase and the 5D motion model parameters, which could be used to generate the breathing pattern during the CT acquisition. Methods: 5D respiratory motion model was proposed for accurately modeling the motion of lung and lung tumor tissues. 4D images are then parameterized by a reference image, measured breathing amplitude, breathing rate, two time-independent vector fields that describe the 5D model parameters, and a scalar field that describes the change in HU as a function of breathing amplitude. In contrast with the traditional method of reconstructing multiple temporal image phases to reduce respiratory artifact, 5D model based method simplify the problem into the reconstruction of a single reference image and the 5D motion model parameters. The reconstruction formulation of the reference image and scalar and vector fields is a nonlinear least-square optimization problem that consists of solving the reference image and fields alternately, in which the reference image is regularized with the total variation sparsity transform and the vector fields are solved through linearizations regularized by the H1 norm. 2D lung simulations were performed in this proof-of-concept study. Results: The breathing amplitude, its rate, and the corresponding scalar and vector fields were generated from a patient case. Compared with filtered backprojection method and sparsity regularized iterative method for the phase-by-phase reconstruction, the proposed 5D motion model based method yielded improved image quality. Conclusion: Based on 5D respiratory motion model, we have developed a new iterative reconstruction method for 4D CBCT that has the potential for improving image quality while providing needed on-table motion information.

60 APPLIED LIFE SCIENCES↗

Fast and flexible control of beam longitudinal phase space for high-repetition-rate x-ray free-electron lasers

The wide-ranging requirements for the photon properties from multiple beamlines in superconducting based free-electron lasers (FELs) demand more challenging beam manipulation techniques. Shot-by-shot control of electron beam bunch length and peak current at high repetition rate up to megahertz is highly desired. In this paper, we present a comprehensive study of a method based on a 2-m-long normal conducting radio-frequency cavity to achieve fast and flexible control of beam compression and realize the full potential of the facility, including theoretical analysis, beam dynamics simulations, and conceptual cavity design for the Linac Coherent Light Source II and its high-energy upgrade. We illustrate the physical mechanism of the chirping cavity on the control of the final beam compression and propose methods to lower the requirements for the cavity parameters. The application of this method will allow tailored photon properties of individual beamlines to optimize their performance and drastically improve the multiplexing capabilities of a high-repetition rate FEL facility.

42 ENGINEERING↗

Mitigating oxygen loss to improve the cycling performance of high capacity cation-disordered cathode materials

Recent progress in the understanding of percolation theory points to cation-disordered lithium-excess transition metal oxides as high-capacity lithium-ion cathode materials. Nevertheless, the oxygen redox processes required for these materials to deliver high capacity can trigger oxygen loss, which leads to the formation of resistive surface layers on the cathode particles. Here, we demonstrate here that, somewhat surprisingly, fluorine can be incorporated into the bulk of disordered lithium nickel titanium molybdenum oxides using a standard solid-state method to increase the nickel content, and that this compositional modification is very effective in reducing oxygen loss, improving energy density, average voltage, and rate performance. We argue that the valence reduction on the anion site, offered by fluorine incorporation, opens up significant opportunities for the design of high-capacity cation-disordered cathode materials.

25 ENERGY STORAGE↗

Quantifying the Influences of Epoxide Binding in Epoxide/CO 2 Ring Opening Copolymerization Catalysis

Understanding and predicting the effect of epoxide structure on the rate of polymerization in epoxide/CO 2 ring opening copolymerization catalysis is a long-standing challenge. Here, a known highly active Co(III)K(I) catalyst is used to investigate the influences of six different epoxides' binding strengths on their rates of copolymerization. Since calculations and experiments indicate that studying the catalytically relevant Co(III)−epoxide adduct directly is experimentally challenging, epoxide−catalyst binding interactions are quantified using a Co(II)K(I) complex to model the key catalytic intermediate. Epoxide−catalyst coordination is investigated using UV−vis spectroscopy titrations which provide fast and effective determination of association or binding constants. The epoxide−catalyst equilibrium constants show a clear exponential correlation with copolymerization rates and a new catalyst performance linear free energy relationship is revealed. Epoxides exhibiting stronger catalyst binding constants show higher copolymerization rates. The structure−activity correlation is consistent with the polymerization kinetics, mechanism and DFT calculations. Both the methods to investigate epoxide−catalyst coordination and the linear free energy relationship are shown to apply to the series of six epoxides and a second Co(III)K(I) catalyst. These structure− performance relationships are likely applicable to other transition metal catalysts and should expedite future epoxide and catalyst selection to make useful poly(carbonate) materials.

catalysts↗

Using Analogs for Performance Testing of Humans in Spacesuits in Simulated Reduced Gravity

In general metabolic rates tend to be higher in NBL than in flight: a) Restraint method dependant; b) Significant differences between the NBL and flight for BRT and APFR (buoyancy effects). c) No significant difference between NBL and flight for free float and SRMS/SSRMS operations. The total metabolic energy expenditure for a given task and for the EVA as a whole are similar between NBL and flight: a) NBL metabolic rates are higher, but training EVAs are constrained to 5 1/2 hours. b) Flight metabolic rates are lower, but the EVAs are typically an hour or more longer in duration. NBL metabolic rates provide a useful operational tool for flight planning. Quantifying differences and similarities between training and flight improves knowledge for preparation of safe and efficient EVAs.

Norcross, Jason R.↗

A Probabilistic Method of Assessing Carbon Accumulation Rate at Imnavait Creek Peatland, Arctic Long Term Ecological Research Station, Alaska

Arctic peatlands are an important part of the global carbon cycle, accumulating atmospheric carbon as organic matter since the Late glacial. Current methods for understanding the changing efficiency of the peatland carbon sink rely on peatlands with an undisturbed stratigraphy. Here we present a method of estimating primary carbon accumulation rate from a site where permafrost processes have either vertically or horizontally translocated nearby carbon-rich sediment out of stratigraphic order. Briefly, our new algorithm estimates the probability of the age of deposition of a random increment of sediment in the core. The method assumes that if sediment age is measured at even depth increments, dates are more likely to occur during intervals of higher accumulation rate and vice versa. Multiplying estimated sedimentation rate by measured carbon density yields carbon accumulation rate. We perform this analysis at the Imnavait Creek Peatland, near the Arctic Long Term Ecological Research network site at Toolik Lake, Alaska. Using classical radiocarbon age modeling, we find unreasonably high rates of carbon accumulation at various Holocene intervals. With our new method, we find accumulation rate changes that are in improved agreement within the context of other sites throughout Alaska and the rest of the Circum-Arctic region.

carbon accumulation;Imnavait;peatlands;permafrost;↗

Co-Extrusion (CoEx) for Cost Reduction of Advanced High-Energy-and-Power Battery Electrode Manufacturing

Co-Extrusion (CoEx) is a deposition technology developed at PARC that uses engineered fluidic channels to cause multiple streams of dissimilar fluids to impart shape to one another. Here, we describe the use of CoEx to produce structured cathode electrode films to improve electrochemical performance of thick electrode films. CoEx enables us to create structured electrode films that have periodic regions of enhanced ionic conductivity, enabling higher utilization of thicker cathode films at high discharge rates. While increasing electrode thickness is a known method for increasing energy density of battery electrodes, this increase in energy density typically also results in reduced power density. This project, a collaboration between the Palo Alto Research Center, Oak Ridge National Laboratories, and Ford Motor Company, seeks to first validate the benefits of CoEx at the coin cell level, before performing the necessary R&D effort to scale production up to large (10+ Ah) pouch cells that will show increased energy density without a reduction in power density. We used conventional battery materials (commercially available NMC, PVDF, carbon black, and graphite) to produce structured electrodes via CoEx and compared them to thick and thin conventionally produced (unstructured) battery electrodes. CoEx electrodes show improved high rate performance compared to unstructured electrodes, resulting in higher energy density pouch cells compared to the baseline electrode of 7 and 11% in volumetric and gravimetric energy density, respectively. These electrodes also showed substantially improved electrochemical performance at high discharge rates compared to thick conventional electrodes.

25 ENERGY STORAGE↗

Reducing Communication in Algebraic Multigrid Using Additive Variants

Algebraic multigrid (AMG) has proven to be an effective scalable solver on many high performance computers. However, its increasing communication complexity on coarser levels has shown to seriously impact its performance on computers with high communication cost. Moreover, additive AMG variants provide not only increased parallelism as well as decreased numbers of messages per cycle but also generally exhibit slower convergence. Here we present various new additive variants with convergence rates that are significantly improved compared to the classical additive algebraic multigrid method and investigate their potential for decreased communication, and improved communication-computation overlap, features that are essential for good performance on future exascale architectures.

97 MATHEMATICS AND COMPUTING↗

New Insights into the High‐Performance Black Phosphorus Anode for Lithium‐Ion Batteries

Abstract Black phosphorus (BP) is a promising anode material in lithium‐ion batteries (LIBs) owing to its high electrical conductivity and capacity. However, the huge volume change of BP during cycling induces rapid capacity fading. In addition, the unclear electrochemical mechanism of BP hinders the development of rational designs and preparation of high‐performance BP‐based anodes. Here, a high‐performance nanostructured BP–graphite–carbon nanotubes composite (BP/G/CNTs) synthesized using ball‐milling method is reported. The BP/G/CNTs anode delivers a high initial capacity of 1375 mA h g −1 at 0.15 A g −1 and maintains 1031.7 mA h g −1 after 450 cycles. Excellent high‐rate performance is demonstrated with a capacity of 508.1 mA h g −1 after 3000 cycles at 2 A g −1 . Moreover, for the first time, direct evidence is provided experimentally to present the electrochemical mechanism of BP anodes with three‐step lithiation and delithiation using ex situ X‐ray diffraction (XRD), ex situ X‐ray absorption spectroscopy (XAS), ex situ X‐ray emission spectroscopy, operando XRD, and operando XAS, which reveal the formation of Li 3 P 7 , LiP, and Li 3 P. Furthermore, the study indicates an open‐circuit relaxation effect of the electrode with ex situ and operando XAS analyses.

Li, Minsi↗

Laser-induced damage-growth threshold at 351 nm in the nanosecond regime in dielectric coatings employing different high-index materials

The laser-damage performance of HfO 2 /SiO 2 and Al 2 O 3 /SiO 2 mirrors was investigated at a laser wavelength of 351 nm with nanosecond pulse durations. A method was developed to quantify the laser-induced damage-growth threshold under conditions relevant to high-repetition-rate, large-aperture laser systems. The results suggest that the damage-growth performance cannot be inferred from the corresponding damage-initiation threshold that is commonly used to evaluate the performance of optical materials. Here, a systematic difference was also observed in the performance between these two groups of high-index materials, with the Al 2 O 3 /SiO 2 mirrors exhibiting about twofold improvement in the damage-growth threshold.

36 MATERIALS SCIENCE↗

Calculations of energies, transition rates, and lifetimes for the fluorine-like isoelectronic sequence with Z=31−35

Employing two state-of-the-art methods, multiconfiguration Dirac–Hartree–Fock and second-order many-body perturbation theory, highly accurate calculations are performed for the lowest 200 fine-structure levels arising from the 2l{sup 7},2l{sup 6}3l{sup ′} and 2l{sup 6}4l{sup ′} configurations of the fluorine-like isoelectronic sequence with Z=31−35. Complete and consistent atomic data, including excitation energies, lifetimes, wavelengths, and E1, E2, M1, M2 line strengths, oscillator strengths, and transition rates among these 200 levels are provided. Comparisons are made between the present two data sets, as well as with other available experimental and theoretical values. The present data are accurate enough for identification and deblending of emission lines involving the n=3,4 levels, and are also useful for modeling and diagnosing fusion plasmas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effects of Nb-doped on the structure and electrochemical performance of LiFePO{sub 4}/C composites

The olivine-type niobium doping Li{sub 1−x}Nb{sub x}FePO{sub 4}/C (x=0, 0.005, 0.010, 0.015, 0.025) cathode materials were synthesized via a two-step ball milling solid state reaction. The effects of Nb doping were charactered by X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), galvanostatic intermittent titration technique (GITT), cyclic voltammetry (CV), electrochemical impedance spectra (EIS) and galvanostatic charge–discharge. It is found that Nb doping enlarges the interplanar distance of crystal plane parallel to [0 1 0] direction in LiFePO{sub 4}. In other words, it widens the one dimensional diffusion channels of Li{sup +} along the [0 1 0] direction. Electrochemical test results indicate that the Li{sub 0.99}Nb{sub 0.01}FePO{sub 4}/C composite exhibits the best electrochemical performance with initial special discharge capacity of 139.3 mA h g{sup −1} at 1 C rate. The present synthesis route is promising in making the solid state reaction method more practical for preparation of the LiFePO{sub 4} material. - Graphical abstract: The proper amount of Nb doping widens the one dimensional diffusion channels of Li{sup +} along the [0 1 0] direction. Display Omitted - Highlights: • The Nb doping LiFePO{sub 4}/C is prepared by a facile two-step ball milling solid state reaction. • The sample possesses the better high-rate performance. • The tap density of Li{sub 0.99}Nb{sub 0.01}FePO{sub 4}/C sample is 1.76 g cm{sup −3}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing Sodium-Ion Battery Cathodes: A Low-Cost, Eco-Friendly Mechanofusion Route from TiO 2 Coating to Ti 4+ Doping

Layered oxide battery cathodes often require extra stabilization strategies, such as surface coating or doping, to mitigate side reactions and enhance longevity. Conventional methods such as aqueous deposition and atomic layer deposition are costly and environmentally unfriendly and even damage the original structure, especially for air-sensitive sodium-ion battery (SIB) cathodes. Herein, we introduce an all-dry mechanofusion technique that modifies hydroxide precursors with TiO 2 coating before sintering with a sodium source. Using advanced characterizations including X-ray diffraction, neutron diffraction, and solid-state nuclear magnetic resonance for structural insights, X-ray absorption spectroscopy to study metal valence states, and transmission X-ray microscopy for nanoscale visualization of nickel oxidation states, we verified that postsintering transforms TiO 2 surface coating into Ti doping, leading to improved Ni-oxidation homogeneity, modified charge compensation, and enhanced thermal stability. Electrochemical tests reveal superior performance in capacity retention, rate capability, and air stability for these modified cathodes, with pouch cells maintaining over 85% capacity after 650 cycles. This method presents a sustainable, cost-effective route for advanced SIB cathode development.

36 MATERIALS SCIENCE↗

Neural Image Compression: Generalization, Robustness, and Spectral Biases

Recent advances in neural image compression (NIC) have resulted in models which are starting to outperform traditional codecs. While this has led to growing excitement about using these methods in real-world applications, the successful adoption of any machine learning system (including NIC) in the wild requires it to generalize (and be robust) to unseen distribution shifts at deployment time. Unfortunately, current research lacks comprehensive datasets and informative tools to evaluate and understand compression performance in real-world settings. To bridge this crucial gap, first, this paper presents a comprehensive benchmark suite to evaluate the out-of-distribution (OOD) performance of image compression methods. Specifically, we design CLIC-C and Kodak-C by introducing 15 common corruptions to popular CLIC and Kodak benchmarks. Next, we propose spectrally inspired introspection tools to gain a deeper understanding of errors introduced by image compression methods as well as their OOD performance. To this end, we carry out a detailed performance comparison of the classical codec with various variants of NIC (e.g., original, variable rate, pruned), revealing intriguing findings that challenge our current understanding of the strengths and limitations of NIC. Finally, we corroborate our empirical findings with theoretical analysis, providing an in-depth view of the OOD performance of NIC. Our benchmarks, spectral introspection tools, and findings provide a crucial bridge to the real-world adoption of NIC. We hope that our work will propel future efforts in designing more robust and generalizable NIC methods.

neural networks, Variational Autoencoder, robustne↗

Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector

Purpose: Current methods of low dose rate brachytherapy source strength verification for sources preloaded into needles consist of either assaying a small number of seeds from a separate sample belonging to the same lot used to load the needles or performing batch assays of a subset of the preloaded seed trains. Both of these methods are cumbersome and have the limitations inherent to sampling. The purpose of this work was to investigate an alternative approach that uses an image-based, autoradiographic system capable of the rapid and complete assay of all sources without compromising sterility. Methods: The system consists of a flat panel image detector, an autoclavable needle holder, and software to analyze the detected signals. The needle holder was designed to maintain a fixed vertical spacing between the needles and the image detector, and to collimate the emissions from each seed. It also provides a sterile barrier between the needles and the imager. The image detector has a sufficiently large image capture area to allow several needles to be analyzed simultaneously.Several tests were performed to assess the accuracy and reproducibility of source strengths obtained using this system. Three different seed models (Oncura 6711 and 9011 {sup 125}I seeds, and IsoAid Advantage {sup 103}Pd seeds) were used in the evaluations. Seeds were loaded into trains with at least 1 cm spacing. Results: Using our system, it was possible to obtain linear calibration curves with coverage factor k = 1 prediction intervals of less than ±2% near the centre of their range for the three source models. The uncertainty budget calculated from a combination of type A and type B estimates of potential sources of error was somewhat larger, yielding (k = 1) combined uncertainties for individual seed readings of 6.2% for {sup 125}I 6711 seeds, 4.7% for {sup 125}I 9011 seeds, and 11.0% for Advantage {sup 103}Pd seeds. Conclusions: This study showed that a flat panel detector dosimetry system is a viable option for source strength verification in preloaded needles, as it is capable of measuring all of the sources intended for implantation. Such a system has the potential to directly and efficiently estimate individual source strengths, the overall mean source strength, and the positions within the seed-spacer train.

60 APPLIED LIFE SCIENCES↗

Aerobic Capacity Following Long Duration International Spaces Station (ISS) Missions: Preliminary Results

Maximum oxygen uptake (VO2max) is reduced immediately following space flights lasting <15 d, but has not been measured following long-duration missions. The purpose of this study is to measure VO2max and maximum work rate (WRmax) data from astronauts following ISS flights (91 to 188 d). Methods: Five astronauts [3 M, 2 F: 47+/-6 yr, 174+/-6 cm, 71.9+/-10.9 kg (mean +/- SD)] have participated in the study. Subjects performed upright cycle exercise tests to symptom-limited maximum. An initial test was done approx.270 d before flight to establish work rates for subsequent tests. Subsequent tests, conducted approx.45 d before flight and repeated on the first or second day (R+1/2) and at approx.10 d (R+10) following landing, consisted of 3 5 min stages designed to elicit 25%, 50%, and 75% of preflight VO2max, followed by 25 W(dot)/min increases. VO2, WR, and heart rate (HR) were measured using the ISS Portable Pulmonary Function System [Damec, Odense, DK]. Descriptive statistics are reported. Results: On R+1/2 mean VO2max decreased compared to preflight (Pre: 2.98+/-0.99, R+1/2: 2.63+/-0.56 L(dot)/min); 4 of 5 subjects demonstrated a loss of > 6%. WRmax also decreased on R+1/2 compared to preflight (Pre: 245+/-69, R+1/2: 210+/-45 W). On R+10, VO2max was 2.86+/-0.62 L(dot)/min, with 2 subjects still demonstrating a loss of > 6% from preflight. WRmax on R+10 was 240+/-49 W. HRmax did not change from pre to post-flight. Conclusions: These preliminary results, from the first 5 of 12 planned subjects of an ongoing ISS study, suggest that the majority of astronauts will experience a decrease in VO2max after long-duration space-flight. Interestingly, the two astronauts with the highest preflight VO2max had the greatest loss on R+1/2, and the astronaut with the lowest preflight VO2max increased by 13%. Thus, maintenance of VO2max may be more difficult in astronauts who have a high aerobic capacity, perhaps requiring more intense in-flight exercise countermeasure prescriptions.

Moore, Alan D.↗