Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Update on results of SPRE testing at NASA Lewis

The Space Power Research Engine (SPRE), a free-piston Stirling engine with a linear alternator, is being tested at NASA Lewis Research Center as part of the Civilian Space Technology Initiative (CSTI) as a candidate for high capacity space power. Results are presented from recent SPRE tests designed to investigate the effects of variation in the displacer seal clearance and piston centering port area on engine performance and dynamics. The effects of these variations on PV power and efficiency are presented. Comparisons of the displacer seal clearance test results with HFAST code predictions show good agreement for PV power but poor agreement for PV efficiency. Correlations are presented relating the piston mid-stroke position to the dynamic Delta P across the piston and the centering port area. Test results indicate that a modest improvement in PV power and efficiency may be realized with a reduction in piston centering port area.

Cairelli, James E.↗

Solar Power System Analyses for Electric Propulsion Missions

Solar electric propulsion (SEP) mission architectures are applicable to a wide range of NASA missions including human Mars exploration and robotic exploration of the outer planets. In this paper, we discuss the conceptual design and detailed performance analysis of an SEP stage electric power system (EPS). EPS performance, mass and area predictions are compared for several PV array technologies. Based on these studies, an EPS design for a 1-MW class, Human Mars Mission SEP stage was developed with a reasonable mass, 9.4 metric tons, and feasible deployed array area, 5800 sq m. An EPS was also designed for the Europa Mapper spacecraft and had a mass of 151 kg and a deployed array area of 106 sq m.

Kerslake, Thomas W.↗

Calculation Method for Predicting AM0 Isc from High Altitude Aircraft Flight Data

High altitude aircraft have been used by by the space photovoltaic (PV) community to determine the Air Mass Zero (AM0) performance of solar cells for over fifty years. Relative to in-space measurement opportunities, these methods are generally cheaper and more readily available. The data obtained, however, must be corrected for residual atmospheric effects. This paper details the correction method currently being used for the calculation of the AM0 short-circuit current (Isc) for photovoltaic devices flown on the NASA ER-2 (Earth Resources-2) calibration platform. This method would also be applicable to any other high altitude method where Isc data is collected over a sufficiently large range of altitudes.

Myers, Matthew G.↗

Calculation Method for Predicting AM0 Isc from High Altitude Aircraft Flight Data

High altitude aircraft have been used by the space photovoltaic (PV) community to determine the air mass Zero (AM0) performance of solar cells for over fifty years. Relative to in-space measurement opportunities, these methods are generally cheaper and more readily available. The data obtained, however, must be corrected for residual atmospheric effects. This paper details the correction method currently being used for the calculation of the estimated AM0 short-circuit current (Isc) for photovoltaic devices flown on the NASA ER-2 calibration platform. This method would also be applicable to other high altitude methods where Isc data is collected over a sufficiently large range of altitudes. An initial comparison with a four junction (4J) cell flown on the CASOLBA high altitude balloon platform showed an agreement to 0.2%.

AM0↗

Uncertainty-aware photovoltaic generation estimation through fusion of physics with harmonics information using Bayesian neural networks

We develop an aggregate photovoltaic generation estimation methodology that uses diverse inputs and can reason on its current input-dependent predictive uncertainty. Named PVPHEst, for PhotoVoltaic Physics- & Harmonics-driven Estimator, the resulting tool is intelligently weighing and fusing information carried by the output of physics models, harmonics, and line sensors, using Bayesian neural networks and related techniques aimed at solving machine learning problems with intrinsic uncertainty quantification. As each of the three input classes carries heterogeneous information that only sheds light on one facet of the estimation problem but its value can diminish in the face of diverse grid phenomena, PV-PHEst with its estimation and uncertainty reasoning capabilities perform a nontrivial and potentially mission-critical task of value to grid operators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Blood Volume: Importance and Adaptations to Exercise Training, Environmental Stresses and Trauma/Sickness

This paper reviews the influence of several perturbations (physical exercise, heat stress, terrestrial altitude, microgravity, and trauma/sickness) on adaptations of blood volume (BV), erythrocyte volume (EV), and plasma volume (PV). Exercise training can induced BV expansion; PV expansion usually occurs immediately, but EV expansion takes weeks. EV and PV expansion contribute to aerobic power improvements associated with exercise training. Repeated heat exposure induces PV expansion but does not alter EV. PV expansion does not improve thermoregulation, but EV expansion improves thermoregulation during exercise in the heat. Dehydration decreases PV (and increases plasma tonicity) which elevates heat strain and reduces exercise performance. High altitude exposure causes rapid (hours) plasma loss. During initial weeks at altitude, EV is unaffected, but a gradual expansion occurs with extended acclimatization. BV adjustments contribute, but are not key, to altitude acclimatization. Microgravity decreases PV and EV which contribute to orthostatic intolerance and decreased exercise capacity in astronauts. PV decreases may result from lower set points for total body water and central venous pressure, which EV decrease bay result form increased erythrocyte destruction. Trauma, renal disease, and chronic diseases cause anemia from hemorrhage and immune activation, which suppressions erythropoiesis. The re-establishment of EV is associated with healing, improved life quality, and exercise capabilities for these injured/sick persons.

Sawka, Michael N.↗

Low-background InSb array development

Photovoltaic indium antimonide (PV InSb) detector technology has matured over the past several years to enable a wide variety of applications to use this high-performance detector material to advantage. The operating conditions for most of the applications to date for back-side illuminated PV InSb arrays have encompassed focal plane temperatures ranging from 40 to approximately 95 K, with the majority in the narrower range between 60 and 80 K. Background flux conditions have ranged from 10 to the 10th power ph/sq cm/sec to 10 to the 16th power ph/sq cm/sec, most typically between 10 to the 12th power and 10 to the 14th power ph/sq cm/sec. Appropriately, the array parameters were optimized for maximum performance over these temperature and background ranges. The key parameters which were peaked in this process were the resistance-area product of the detectors and their quantum efficiency. The Space Infrared Telescope Facility (SIRTF) Infrared Array Camera requirements, however, present very low temperature and background operating conditions, plus the need for very high signal to noise ratios. Preliminary analysis indicates that back-side illuminated PV InSb arrays can be optimized for operation under these conditions, and some performance projections will be presented.

Thom, R. D.↗

Empirical thermophotovoltaic performance predictions and limits

Significant progress has been made in the field of thermophotovoltaics, with efficiency recently rising to over 40% due to improvements in cell design and material quality, higher emitter temperatures, and better spectral management. However, inconsistencies in trends for efficiency with semiconductor bandgap energy across various temperatures pose challenges in predicting optimal bandgaps or expected performance for different applications. To address these issues, here we present realistic performance predictions for various types of single-junction cells over a broad range of emitter temperatures using an empirical model based on past cell measurements. Our model is validated using data from different authors with various bandgaps and emitter temperatures, and an excellent agreement is seen between the model and the experimental data. Using our model, we show that in addition to spectral losses, it is important to consider practical electrical losses associated with series resistance and cell quality to avoid overestimation of system efficiency. Here, we also show the effect of modifying various system parameters such as bandgap, above and below-bandgap reflectance, saturation current, and series resistance on the efficiency and power density of thermophotovoltaics at different temperatures. Finally, we predict the bandgap energies for best performance over a range of emitter temperatures for different cell material qualities.

14 SOLAR ENERGY↗

A Universal Converter for DC, Single-phase AC, and Multi-phase AC Systems (Final Report)

The goal of this project was to develop a new class of universal power converters that utilize the unique properties of WBG switches, including high reverse voltage blocking and fast switching, to achieve superior performance in universal converters. Some of the features of the proposed converter are as follows: 1) Significantly longer lifetime, higher power density, lower costs associated with bill of materials, and lower shipping, installation, and repair costs compared to the existing WBG-based solutions, 2) Very flexible operation for transferring power between any type of source (dc, single-phase ac, or multi-phase ac) and any type of load (dc, single-phase ac, or multi-phase ac) without using large passive components or additional stages/components, even when the instantaneous values of input and output power are not the same, and 3) High performance operation at all power levels. Considering its advantages and wide range of applications, the proposed converter has the potential to create a new paradigm in power electronics. Among numerous applications of this converter are electric vehicles, wind energy systems, PV systems, industrial motor drives, residential variable frequency drive systems, and nanogrid applications. This project focused on the application of this converter for residential PV, residential motor drive, and industrial motor drive applications, and evaluated the performance of this converter for these applications.

42 ENGINEERING↗

SolarAPP+ Pilot Analysis: Performance and Impact of Instant, Online Solar Permitting

The National Renewable Energy Laboratory (NREL) led a collaborative effort to develop the Solar Automated Permit Processing Plus (SolarAPP+), a no-cost solar permitting software solution to address residential solar photovoltaic (PV) permitting resource constraints and streamline solar adoption processes among authorities having jurisdiction (AHJs). The SolarAPP+ is an online portal that automates permit plan review, enabling an instant permit approval process for code-compliant residential PV systems. Based on national model building, electrical, and fire codes, the SolarAPP+ automatically performs a compliance check of permit inputs against code requirements and produces an inspection checklist that can be used to verify installation practices, workmanship, and adherence to the approved design. NREL conducted a two-phase pilot with five participating AHJs and 16 solar contractors, spanning from November 2020 through December 2021, evaluating the ability of SolarAPP+ to deliver instant permits and its impact on four critical areas within each AHJ: permit review timelines; solar adoption timelines; AHJ time saved; and inspection results. The pilot confirmed that SolarAPP+ reduced permit review times to less than one day, reduced solar adoption timelines by an average of 12 days, saved an estimated 2,067 staff hours, and had comparable inspection results to those found in traditional permitting. The pilot further identified key lessons for improving SolarAPP+, including ways to streamline SolarAPP+ adoption, development of training resources, and expansion of supported products.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Impact of TRMM on Mesoscale Model Simulation of Super Typhoon Paka

Tropical cyclone Paka formed during the first week of December 1997 and underwent three periods of rapid intensification over the following two weeks. During one of these periods, which initiated early on December 10, Paka's Dvorak-measured windspeed increased from 23 to 60 m/s over a 48-hr period. On December 18, during the last rapid deepening episode, Paka became a supertyphoon with a maximum wind speed of about 80 m/s. In this study, the Penn State/NCAR Mesoscale Model (MM5) with improved physics (i.e., cloud microphysics, radiation, land-soil-vegetation-surface processes, and TOGA COARE flux scheme) and a multiple level nesting technique (135, 45 and 15 km horizontal resolution) will be used to simulate supertyphoon Paka. We performed two runs initialized with Goddard Earth Observing System (GEOS) data sets. The first GEOS data set does not incorporate either TRMM (tropical rainfall measuring mission satellite) or SSM/I (sensor microwave imager) observed rainfall fields into the GEOS's assimilation system while the second one does. Preliminary results show that the MM5 simulated surface pressure deepened by more than 25 mb (45 km resolution domain) in the run initialized with the GEOS data set incorporating TRMM and SSM/I derived rainfall, compared to the one initialized without. However, the track and precipitation patterns are quite similar between the runs. In our presentation, we will show the impact of TRMM rainfall upon the MM5 simulation of Paka at various horizontal resolutions. We will also examine the physical processes associated with initial explosive development by comparing MM5 simulated rainfall and latent heat release. In addition, budget (vorticity, PV, momentum and heat) calculations and sensitivity tests will be performed to examine the upper-tropospheric and SST mechanisms responsible for the explosive development of Paka.

Tao, W.-K.↗

Viscoelastic Material Characterization and Modeling of Photovoltaic Module Packaging Materials for Direct Finite-Element Method Input

Numerical tools, such as the finite-element method, are increasingly used to design and evaluate the photovoltaic (PV) modules, providing for the reduction of development time and improved performance and reliability. However, high-fidelity material models are necessary to accurately model the complex structural behavior of the involved packaging materials. A common simplification used in recent years is to model the polymer materials (i.e., encapsulant and backsheet) as linear elastic, which will lead to inaccurate results. Therefore, in this work, we present a thorough characterization of the time- and temperature-dependent mechanical response of predominant PV module encapsulant and backsheet materials. Based on this material characterization, we developed and experimentally validated generalized Maxwell models to describe each material's viscoelastic response. In addition, we included measurements of the coefficient of thermal expansion and presented all material models in such a fashion for direct input into commercial finite-element method modeling software.

FEM↗

Current-Voltage Analysis Tool for Solar Fuel Production (CATS) v0.1

The program is expected to be a useful tool during operation of a range of solar-driven electrochemical devices, such as PV-electrolyzers and photoelectrochemical (PEC) devices. It makes use of current-voltage data collected during operation, operation parameters that are easily accessible for many devices of interest. The program captures the time-dependence of loss mechanisms at play during PEC device operation and opens the door for real-time optimizations of operational parameters like the feed humidity to minimize performance losses. Currently, the program is useful for applications where the current-voltage polarization response of the photoabsorber and electrolyzer are pre-recorded, and changes over time can be estimated based on the pre-recorded current-voltage scans. More complicated scenarios that involve permanent degradation of the PV component or complex calculations of the electrolyzer current-voltage characteristics may be included in future versions of this software. Aside from the possibility of deconvoluting loss mechanisms, this software can also reveal possible performance benefits by convective PV cooling when the photoabsorber is integrated into the electrolysis cell. The latter can highlight why certain device architectures may be beneficial over others. No similar technologies are known to the developer.

Kistler, Tobias↗

Analyzing Distribution Transformer Degradation with Increased Power Electronic Loads

The influx of non-linear power electronic loads into the distribution network has the potential to disrupt the existing distribution transformer operations. They were not designed to mediate the excessive heating losses generated from the harmonics. To have a good understanding of current standing challenges, a knowledge of the generation and load mix as well as the current harmonic estimations are essential for designing transformers and evaluating their performance. In this paper, we investigate a mixture of essential power electronic loads for a household designed in PSCAD/EMTdc and their potential impacts on transformer eddy current losses and derating using harmonic analysis. Our findings reveal that in the presence of high power electronic loads (especially third harmonics), increasing PV generation may worsen transformer degradation. However, with a low amount of power electronic loads, additional PV generation helps to reduce the harmonic content in the current and improve transformer performance.

eddy current, harmonics, PV, THD, power transforme↗

Bifacial Photovoltaic Module Degradation Dynamics

In a comprehensive study conducted at NREL's 75 kW bifacial single-axis-tracked field, accelerated degradation was observed in four out of five bifacial silicon photovoltaic (PV) module technologies when compared to their monofacial counterparts. Root cause analysis of accelerated bifacial degradation involved various analytical tools and techniques. This included employing RdTools to identify rates of power loss, conducting measurements on fielded and control modules using infrared imaging, electroluminescence (EL) and photoluminescence (PL), quantum efficiency (QE) analysis, IV-curves assessment, as well as utilizing handheld Raman and reflectance measurement targeted at anti-reflective coating. Most cases pointed to carrier lifetime degradation causing Voc loss and simultaneous Isc loss. In some cases, Isc further decreases likely due to optical effects from encapsulant degradation. The outcomes and methodologies employed in this investigation are documented in this publication. This study's significance is further emphasized by placing the findings within the broader context of the performance and degradation of various bifacial systems, as identified in the PV Fleets data.

bifacial↗

Radiation Effects in III-V Solar Cells Grown by Dynamic Hydride Vapor Phase Epitaxy

The recent development of hydride vapor phase epitaxy (HVPE) is potentially promising as a route to lower the cost of high-efficiency III-V solar cells for space applications. HVPE produces the same materials and device structures as the industry-standard organometallic vapor phase epitaxy (OMVPE) process, and although HVPE has shown promising device efficiencies, it lags the OMVPE growth technique in technical maturity. For example, there are no reports of the performance of HVPE-grown devices in radiation environments. There is an expectation that high-quality (that is, single crystal and low-defect) III-V materials will behave similarly regardless of the growth method. However, it is important to verify assumptions as facts. In this project, we produced materials and devices using both HVPE and OMVPE at NREL and irradiated them using 1 MeV electrons to ascertain the effect of radiation on the materials. We also performed initial work on producing more radiation-hard structures, including devices with the pn junction at the front of the device, and devices with a graded doping profile, both of which help with radiation tolerance. Measurements of the devices post radiation exposure showed that the open-circuit voltage (V OC ) of the HVPE-grown solar cells degraded least on a percent basis, although they also started from a lower baseline than the OMVPE-grown devices. All solar cells reached approximately the same V OC after irradiation, indicating that the dose used was sufficient to degrade all device equally. The short-circuit current in the HVPE devices did degrade more than the other solar cells, and this was attributed to a higher-than-expected doping density in the base layer of that cell. The results of these experiments, while by no means comprehensive, do not show any material difference in the radiation effects in OMVPE- and HVPE-grown materials and devices.

14 SOLAR ENERGY↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

SolarAPP+ Performance Review (2024 Data)

The Solar Automated Permit Processing Plus (SolarAPP+) platform is an online portal to facilitate and expedite rooftop solar photovoltaic (PV) and battery storage permitting processes. SolarAPP+ allows PV contractors to upload system specifications, have that information automatically reviewed for code compliance, and receive instant approval for code-compliant systems, reducing authority having jurisdiction (AHJ) staff time needed for review. SolarAPP+ also provides inspection checklists to verify installation practices and adherence to approved designs. This report is part of an ongoing series of reviews of SolarAPP+ performance. Consistent with previous performance reviews, we summarize SolarAPP+ adoption trends to date and compare various metrics for PV systems permitted through SolarAPP+ versus systems permitted through traditional AHJ permitting processes. As of the end of 2024, 799 AHJs had expressed interest in the platform, with 264 fully adopting (215) or piloting (49) the platform. In 2024, 861 installers submitted 37,393 permits through the SolarAPP+ platform, including 27,375 permits for PV+storage systems. SolarAPP+ permits accounted for around 43% of all permits issued in all participating AHJs, and more than 60% of all permits in several participating AHJs. We compare permitting timelines through SolarAPP+ to traditional AHJ permitting processes to assess the platform's performance. Consistent with previous SolarAPP+ performance reviews, we find that permitting timelines are significantly shorter for SolarAPP+ projects. Based on median timelines, a typical SolarAPP+ project is permitted and inspected 12 business days sooner than traditional projects. We estimate that automatic SolarAPP+ permitting saved around 18,400 hours of AHJ staff time in 2024. Finally, we estimate that SolarAPP+ eliminated over 100,000 business days in permitting-related delays in 2024.

14 SOLAR ENERGY↗