Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV battery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

2018 Renewable Energy Data Book

The 2018 Renewable Energy Data Book provides facts and figures on energy and electricity use, renewable electricity in the United States, global renewable energy development, wind power, solar power, geothermal power, biopower, hydropower, marine and hydrokinetic power, battery storage, hydrogen, renewable fuels, voluntary procurement and clean energy investment.

2018 data↗

2023 Annual Technology Baseline (ATB) Cost and Performance Data for Electricity Generation Technologies

These data provide the 2023 update of the Electricity Annual Technology Baseline (ATB). Starting in 2015 NREL has presented the ATB, consisting of detailed cost and performance data, both current and projected, for electricity generation and storage technologies. The ATB products now include data (Excel workbook, Tableau workbooks, and structured summary csv files), as well as documentation and user engagement via a website, presentation, and webinar. Starting in 2021, the data are cloud optimized and provided in the OEDI data lake. The data for 2015 - 2020 are can be found on the NREL Data Search Page. The website documentation can be found on the ATB Website.

Array↗

2024 Annual Technology Baseline (ATB) Cost and Performance Data for Electricity Generation Technologies

These data provide the 2024 update of the Electricity Annual Technology Baseline (ATB). Starting in 2015 NREL has presented the ATB, consisting of detailed cost and performance data, both current and projected, for electricity generation and storage technologies. The ATB products now include data (Excel workbook, Tableau workbooks, and structured summary csv files), as well as documentation and user engagement via a website, presentation, and webinar. Starting in 2021, the data are cloud optimized and provided in the OEDI data lake. The data for 2015 - 2020 are can be found on the NREL Data Search Page. The website documentation can be found on the ATB Website.

Array↗

Impedance-Based Prediction of SSR-Generated Harmonics in Doubly-Fed Induction Generators

Doubly-fed induction generators (DFIGs) are prone to subsynchronous resonance (SSR) with series-compensated transmission lines and experiencing SSR-generated harmonics of wide-ranging magnitudes. This paper presents a large-signal impedance-based approach for the prediction of the magnitude of SSR-generated harmonics in DFIGs. Note that the large-signal impedance of a network shows variation in its impedance response with the magnitude of perturbation at its terminals. It is discovered in this paper that the impedance of a series-compen- sated transmission line starts changing with the magnitude of SSR because of the metal-oxide varistor-based protection of series capacitors in the line. The changing line impedance halts the growth of the SSR beyond a certain point, where the DFIG forms a limit-cycle mode and emits harmonics at the SSR frequency. The discovered role of the protection of series capacitors in SSR not only enables the prediction of SSR-generated harmonics but also can be used for the timely detection of an SSR event to avoid system disruption and sudden loss of bulk generation. The large- signal impedance-based prediction of SSR-generated harmonics in DFIG-based wind and hydro generators is demonstrated using numerical simulations of a 2.5-MVA, 690-V DFIG supplying to a series-compensated transmission line.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Acceptance Testing of a Satellite SCADA Photovoltaic-Diesel Hybrid System

Satellite Supervisory Control and Data Acquisition (SCADA) of a Photovoltaic (PV)/diesel hybrid system was tested using NASA's Advanced Communication Technology Satellite (ACTS) and Ultra Small Aperture Terminal (USAT) ground stations. The setup consisted of a custom-designed PV/diesel hybrid system, located at the Florida Solar Energy Center (FSEC), which was controlled and monitored at a "remote" hub via Ka-band satellite link connecting two 1/4 Watt USATs in a SCADA arrangement. The robustness of the communications link was tested for remote monitoring of the health and performance of a PV/diesel hybrid system, and for investigating load control and battery charging strategies to maximize battery capacity and lifetime, and minimize loss of critical load probability. Baseline hardware performance test results demonstrated that continuous two-second data transfers can be accomplished under clear sky conditions with an error rate of less than 1%. The delay introduced by the satellite (1/4 sec) was transparent to synchronization of satellite modem as well as to the PV/diesel-hybrid computer. End-to-end communications link recovery times were less than 36 seconds for loss of power and less than one second for loss of link. The system recovered by resuming operation without any manual intervention, which is important since the 4 dB margin is not sufficient to prevent loss of the satellite link during moderate to heavy rain. Hybrid operations during loss of communications link continued seamlessly but real-time monitoring was interrupted. For this sub-tropical region, the estimated amount of time that the signal fade will exceed the 4 dB margin is about 10%. These results suggest that data rates of 4800 bps and a link margin of 4 dB with a 1/4 Watt transmitter are sufficient for end-to-end operation in this SCADA application.

Kalu, A.↗

Interoperable, Inverter-Based Distributed Energy Resources (DERs) Enable 100% Renewable and Resilient Utility Microgrids

Project overcomes frequency stability and system control issues when operating distribution microgrids in a low inertia, high PV penetration environment without fossil fuel generators. The team implemented a grid-forming inverter and advanced control features at SDG&E's Borrego Springs Microgrid to demonstrate islanding and blackstart using renewable resources. Simulation and emulation in advance of deployment de-risks field operations.

battery energy storage systems↗

Optimize Topology, Component Sizes, and Operating Strategy of Participant's Protype: Cooperative Research and Development Final Report

The purpose of the project was to complete testing of Shine Technologies LLC’s prototype power system called “Juicebox 3.0.” Testing of the prototype using NREL’s hardware-in-the-loop capabilities, including a DC power supply programmed to simulate PV module output and provide the JuiceBox 3.0 at the specified power level and with a load bank of sufficient capacity to mimic DC and AC loads connected to the outlets of the Juicebox 3.0. The unit is provided with SAE wire connectors. A photo of a JuiceBox 3.0 unit is shown in Figure 1 below.

14 SOLAR ENERGY↗

South Texas Industrial Assessment Center (Final Report)

The South Texas Industrial Assessment Center (ST-IAC) provides small to mid-size manufacturing companies and water treatment plants in the Rio Grande Valley of Texas, free energy assessments to help them reduce costs and stay competitive for sustainable development. The ST-IAC operates within the University of Texas Rio Grande Valley (UTRGV), and is the largest Hispanic-serving IAC in the U.S. Created in 2016, the ST-IAC, situated in the most economically disadvantaged region in the country, has been successful in training students and assessing local industries served by a predominantly Hispanic population. UTRGV, now the second largest Hispanic Serving Institution (HSI) of higher education in the U.S., has a student population of 32,000, of which 90% is Hispanic. While Covid-19 had a negative impact to our program during Budget Periods (BP) 4 and 5, the center still managed to provide opportunities for individuals, manufacturing and water industries in the local region. The program developed an energy engineering program in the region and further advanced national priorities. Those include resilience and sustainability of operations by implementing energy efficiency processes, renewable energy sources, decarbonization, battery storage, and cybersecurity in south Texas.

14 SOLAR ENERGY↗

CRADA Final Report: Open Microgrid Platform

Current microgrid control technology is mostly proprietary, expensive, and inflexible. An open-source, vendor-neutral, publish-subscribe controller will significantly lower the barrier to entry for new technologies and market entrants: inverter, battery, and load control manufacturers; cloud and services providers; and energy aggregators. An OpenFMB controller can significantly reduce the acquisition, integration, and ongoing operating and maintenance costs and increase revenue opportunities for energy producers and consumers. It allows distributed energy resource (DER) owners to replace individual DER components as richer-function, lower-cost devices become available or to incorporate new forecast and optimization algorithms as they are developed. A standard, secure, full-function DER field controller will also provide a low-cost means for grid operators to effectively manage the variability and uncertainty of solar photovoltaics (PV). Under the terms of this CRADA, ORNL has worked with Open Energy Solutions (OES) to advance the transition of ORNL’s existing open-source microgrid controller into a platform geared toward mainstream implementation. Using a more prevalent and memory-safe programming language, Rust, OES has converted ORNL’s current generation on-grid optimization into an application more suitable for industry use. The results of the ported optimization were analyzed by inputting the same arguments in both the current-generation and next-generation optimizers and verifying that the results were equivalent.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Revisiting the Terawatt Challenge

Richard E. Smalley, in 2003, defined the Terawatt (TW) Challenge as “Adapting our energy infrastructure to simultaneously address diminishing oil resources and rising levels of atmospheric CO 2 .” Smalley, best known for the discovery of C 60 , for which he received the 1996 Nobel Prize in Chemistry, continued to address the challenges of anthropomorphic and natural global energy flows until he passed away in 2005. Smalley challenged the world to transform the energy sector. He envisioned electricity transmitted by high-voltage direct current (DC) lines from massively deployed solar plants in sunny areas and remotely sited nuclear plants. He also envisioned using advanced batteries for local storage of energy. To meet the needs of ~10 people in a world with a dwindling oil supply, Smalley asserted that the world would need to transform its fossil-fuel-driven 14-TW (average power) energy used in 2003 to a largely renewable-energy-driven 30–60 TW (average power) in 2050. This would be possible only if solar-electricity costs could be drastically reduced. The challenges associated with this transition have been called the “Terawatt Challenge.” Fifteen years later, solar-module costs have been reduced by tenfold and annual deployment of solar photovoltaic (PV) modules has grown by a factor of 100,from ~1 gigawatt (GW) in 2004 to ~100 GW in 2018, with a total of 500 GW installed worldwide, producing 2% of the planet’s electricity. As global installed solar generating capacity approaches1 TW, we revisit Smalley’s TW challenge to identify what has changed and quantify the TW Challenge for a baseline scenario and for two scenarios designed as upper and lower bounds determined by the degree we implement electrification and storage. In this paper, we show that the energy choices we make today will dramatically affect the magnitude of future global energy requirements.

SOLAR ENERGY↗

Managing PV Power on Mars - MER Rovers

The MER Rovers have recently completed over 5 years of operation! This is a remarkable demonstration of the capabilities of PV power on the Martian surface. The extended mission required the development of an efficient process to predict the power available to the rovers on a day-to-day basis. The performance of the MER solar arrays is quite unlike that of any other Space array and perhaps more akin to Terrestrial PV operation, although even severe by that comparison. The impact of unpredictable factors, such as atmospheric conditions and dust accumulation (and removal) on the panels limits the accurate prediction of array power to short time spans. Based on the above, it is clear that long term power predictions are not sufficiently accurate to allow for detailed long term planning. Instead, the power assessment is essentially a daily activity, effectively resetting the boundary points for the overall predictive power model. A typical analysis begins with the importing of the telemetry from each rover's previous day's power subsystem activities. This includes the array power generated, battery state-of-charge, rover power loads, and rover orientation, all as functions of time. The predicted performance for that day is compared to the actual performance to identify the extent of any differences. The model is then corrected for these changes. Details of JPL's MER power analysis procedure are presented, including the description of steps needed to provide the final prediction for the mission planners. A dust cleaning event of the solar array is also highlighted to illustrate the impact of Martian weather on solar array performance

Mars dust↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmark: Q1 2020 [PowerPoint]

NREL has been modeling U.S. photovoltaic (PV) system costs since 2009. This report benchmarks costs of U.S. solar PV for residential, commercial, and utility-scale systems, with and without storage, built in the first quarter of 2020 (Q1 2020). Our methodology includes bottom-up accounting for all system and project-development costs incurred when installing residential, commercial, and utility-scale systems, and it models the capital costs for such systems.

14 SOLAR ENERGY↗

Optimized Renewable Energy Integration for EV High-Power Dynamic Wireless Charging Systems

Dynamic wireless charging for electric vehicles is an emerging technology to reduce on-board battery size and extend driving range. Due to its unique characteristic of vehicle-speed-related pulse-like load profile, the high-power dynamic wireless charging system (DWCS) introduces high stress to the utility grid. In this paper, an optimization model for renewable energy integration in the DWCS is proposed to mitigate the grid impact and minimize the operation costs of the whole system. As the load profile of DWCS is related to the traffic volume and various approaching vehicle speeds, the annual average daily traffic data and a stochastic model are used to develop 24-hour load profile of DWCS. To find a tradeoff between grid impact mitigation and operation costs minimization, relationships among power demand from power grid, photovoltaic (PV) capacity, wind energy (WE) capacity and energy storage (ES) capacity are analyzed, and the optimization objective and constraints are developed. Numerical simulation results demonstrate that energy storage integration can greatly mitigate the grid impact of DWCS, and optimal ratio of PV and WE can significantly reduce the operation cost of DWCS.

Zeng, Rong↗

Optimal, Reliable Building-Integrated Energy Storage (Cooperative Research and Development Final Report)

The team will advance the commercial readiness of behind-the-meter (BTM) energy storage (ES) systems by employing health-conscious controls that guarantee lifetime and optimize the ES system's value stream when integrated with onsite renewable energy generation. Specifically, the team will develop ES controls that increase the net present value (NPV) of photovoltaics (PV) by 50% in markets where net-metering policies are being replaced by variable electricity pricing structures. The team will also reduce the risk of achieving a 10-year ES warranty lifetime by at least one order of magnitude. The successful two-year project will develop the controls and system enabling Eaton to commercialize the technology by 2021. The developments achieved through this project may enable wide scale adoption of stationary energy storage benefitting the public.

25 ENERGY STORAGE↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

Photovoltaic stand-alone modular systems, phase 2

The final hardware and system qualification phase of a two part stand-alone photovoltaic (PV) system development is covered. The final design incorporated modular, power blocks capable of expanding incrementally from 320 watts to twenty kilowatts (PK). The basic power unit (PU) was nominally rated 1.28 kWp. The controls units, power collection buses and main lugs, electrical protection subsystems, power switching, and load management circuits are housed in a common control enclosure. Photo-voltaic modules are electrically connected in a horizontal daisy-chain method via Amp Solarlok plugs mating with compatible connectors installed on the back side of each photovoltaic module. A pair of channel rails accommodate the mounting of the modules into a frameless panel support structure. Foundations are of a unique planter (tub-like) configuration to allow for world-wide deployment without restriction as to types of soil. One battery string capable of supplying approximately 240 ampere hours nominal of carryover power is specified for each basic power unit. Load prioritization and shedding circuits are included to protect critical loads and selectively shed and defer lower priority or noncritical power demands. The baseline system, operating at approximately 2 1/2 PUs (3.2 kW pk.) was installed and deployed. Qualification was successfully complete in March 1983; since that time, the demonstration system has logged approximately 3000 hours of continuous operation under load without major incident.

Naff, G. J.↗

The Power and Energy Storage Systems Toolbox -- PSTess v.1.0

The Power and Energy Storage Systems Toolbox (PSTess) is a MATLAB-based computing package for dynamic simulation and analysis of utility-scale battery storage systems. This codebase is a fork of the Power Systems Toolbox Version 3.0, developed at Rensselaer Polytechnic Institute (RPI) and Cherry Tree Scientific Software. While PSTess shares a common lineage with PST, it is a substantially different application. As the name implies, the main distinguishing characteristic of PSTess is its ability to model inverter-based energy storage systems (ESS). The model that enables this is called ess.m, and it serves the dual role of representing ESS operational constraints and the generator/converter interface. With PSTess, the generator/converter interface is modeled as a controllable current source with the ability to modulate both active and reactive current. The model ess.m permits four-quadrant modulation, which allows it to represent a wide variety of inverter-based resources beyond energy storage when paired with an appropriate supplemental control model. Examples include utility-scale photovoltaic (PV) power plants, type 4 wind plants, and static synchronous compensators (STATCOM). This capability is especially useful for modeling hybrid plants that combine energy storage with renewable resources. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-8322 O

Elliott, RyanT.↗

Catalina Repower Feasibility Study: NREL Phases I & II Summary Report

Engineers at the National Renewable Energy Laboratory (NREL) supported Southern California Edison (SCE) and the United States Environmental Protection Agency (EPA) by conducting technical and economic analyses for energy systems at Santa Catalina (Catalina) Island, which is located 22 miles off the coast of Long Beach, California. This effort was part of a broader Repower Catalina Feasibility Study that was also supported by NV5, an engineering consulting firm and project partner to NREL for this analysis. This document describes NREL’s techno-economic modeling and optimization analysis for the first two phases of this project which focus on supply-side generation and energy storage options for Catalina. SCE’s goal for this analysis is to determine a strategy for electricity generation on Catalina Island that results in lower energy costs, improved energy resiliency, and reduced air emissions. EPA goals for this effort are to reduce emissions of air pollution and encourage renewable energy development on contaminated and formerly contaminated lands when such development is aligned with the community’s vision for the site. Currently, an on-island SCE power plant serves the Catalina Island electrical load with 6 reciprocating diesel generators totaling 9.4 MW; 23 propane-fueled microturbines totaling 1.5 MW; and a 1-MW, 7.2-MWh sodium sulfur battery energy storage system (BESS). In 2017, the electricity consumption on the island was 29.1 GWh, with an average load of 3.3 MW and peak load of approximately 5.5 MW. Considering new environmental standards on diesel generator emissions from California’s South Coast Air Quality Management District, a 60% renewable energy target for 2030 laid out in California’s Senate Bill 100, SCE’s Clean Power Electrification Pathway, and the characteristics of the island’s existing diesel generators, SCE is seeking to evaluate the technical and economic implications of different energy technology options to determine a path forward. Phases I and II of the Repower Catalina Feasibility Study, summarized in this document, evaluated the following: Interconnection with the mainland via an undersea cable; On-island fossil fuel generation, including diesel, propane, and/or liquified natural gas (LNG); On-island renewable energy (RE) technologies, including solar photovoltaics (PV), wind turbines, and wave energy devices; BESS to support the above generation technologies; Initial analysis of the potential impacts of implementing energy efficiency measures. Results indicate strong techno-economic potential for a mix of on-island diesel and/or propane generators, solar PV, BESS, and energy efficiency measures to help SCE and Catalina achieve their goals compliant with California’s emissions and clean energy standards while minimizing electricity life cycle costs (LCC) over the 30-year analysis period. This document summarizes the considerations and findings of Phases I and II, focusing on high-level takeaways from Phase I and more detailed results from Phase II, and discusses a potential path forward for Phase III.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗