Characterization of a gigabit transceiver for the ATLAS inner tracker pixel detector readout upgrade

We present a gigabit transceiver prototype Application Specific Integrated Circuit (ASIC), GBCR, for the ATLAS Inner Tracker (ITk) Pixel detector readout upgrade. GBCR is designed in a 65-nm CMOS technology and consists of four upstream receiver channels, a downstream transmitter channel, and an Inter-Integrated Circuit (I2C) slave. The upstream channels receive the data at 5.12 Gbps passing through 5-meter 34-American Wire Gauge (AWG) Twin-axial (Twinax) cables, equalize and retime them with a recovered clock, and then drive an optical transmitter. The downstream channel receives the data at 2.56 Gbps from an optical receiver and drives the cable as same as the upstream channels. The jitter of the upstream channel output is measured to be 35 ps (peak-peak) when the Clock-Data Recovery (CDR) module is turned on and the jitter of the downstream channel output after the cable is 138 ps (peak-peak). The power consumption of each upstream channel is 72 mW when the CDR module is turned on and the downstream channel consumes 27 mW. GBCR survives the total ionizing dose of 200 kGy.

47 OTHER INSTRUMENTATION↗

Picosecond Timing Resolution Measurements of Low Gain Avalanche Detectors with a 120 GeV Proton Beam for the TOPSiDE Detector Concept

This paper presents results that take a critical step toward proving 10 ps timing resolution’s feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 μm and 50 μm are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 μm thick LGADs at -30°C with a precision of 14.3 ± 1.5 ps.

Particle tracking detectors↗

Performance in beam tests of irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS detector to mitigate pile-up effects during the High Luminosity (HL) upgrade of the Large Hadron Collider (LHC) at CERN. The design of the HGTD is based on the use of Low Gain Avalanche Detectors (LGADs), with an active thickness of 50 μm, that allow to measure with high-precision the time of arrival of particles. The HGTD will improve the particle-vertex assignment by measuring the track time with a resolution ranging from approximately 30 ps at the beginning of the HL-LHC operations to 50 ps at the end. Performances of several unirradiated, as well as neutron- and proton-irradiated, LGAD sensors from different vendors have been measured in beam test campaigns during the years 2018 and 2019 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few μm. Collected charge, time resolution and hit efficiency are presented. In addition to these properties, the charge uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

47 OTHER INSTRUMENTATION↗

A high-resolution clock phase shifter circuitry for ALTIROC

Abstract A high-resolution clock phase shifter is implemented to adjust the phase of multiple clocks at 40 MHz, 80 MHz, or 640 MHz in the ALTIROC chip. The phase shifter has a coarse-phase shifter and a fine-phase shifter to achieve a step size of 97.7 ps and an adjustable range of 25 ns. The fine delay unit is based on a Delay Locked Loop (DLL) operating at 640 MHz. The phase shifter is fabricated in a 130 nm CMOS process. The area of the phase shifter is 725 µm × 248 µm. The Differential Non-Linearity (DNL) and the Integral Non-Linearity (INL) are ±0.6 LSB and ±0.75 LSB, respectively. The jitter from −25 °C to 20 °C is less than 15.5 ps (RMS), including the contributions from the FPGA clock source and the PLL. The power consumption is 11.2 mW.

Instruments & Instrumentation↗

Timing Performance of the CMS High Granularity Calorimeter Prototype

This paper describes the experience with the calibration,reconstruction and evaluation of the timing capabilities of the CMSHGCAL prototype in the beam tests in 2018. The calibrationprocedure includes multiple steps and corrections ranging from tensof nanoseconds to a few hundred picoseconds. The timing performanceis studied using signals from positron beam particles with energiesbetween 20 GeV and 300 GeV. The performance is studied as afunction of particle energy against an external timing reference aswell as standalone by comparing the two different halves of theprototype. The timing resolution is found to be 60 ps forsingle-channel measurements and better than 20 ps for full showersat the highest energies, setting excellent perspectives for theHGCAL calorimeter performance at the HL-LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the ATLAS forward proton Time-of-Flight detector in Run 2

We present performance studies of the Time-of-Flight (ToF) subdetector of the ATLAS Forward Proton (AFP) detector at the LHC. Efficiencies and resolutions are measured using high-statistics data samples collected at low and moderate pile-up in 2017, the first year when the detectors were installed on both sides of the interaction region. While low efficiencies are observed, of the order of a few percent, the resolutions of the two ToF detectors measured individually are 21 ps and 28 ps, yielding an expected resolution of the longitudinal position of the interaction, z vtx , in the central ATLAS detector of 5.3 ± 0.6 mm. This is in agreement with the observed width of the distribution of the difference between z vtx , measured independently by the central ATLAS tracker and by the ToF detector, of 6.0 ± 2.0 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Saccadic Component Measure on Smooth Pursuit Tests

ABSTRACT Introduction Despite the advancement of eye-tracking technology for smooth pursuit (SP) eye movement evaluation, qualitative observation offers much information that is not captured by computers; hence, both objective and qualitative information should be utilized to evaluate SP. This study examined the consistency among our clinicians when evaluating SP using normal (N), grossly normal (GN), mildly abnormal (MA), and abnormal (AB) as classifications. We then evaluated the effect of combining GN and MA into a single subclinical (SUBC) category. We also evaluated the computerized percent saccade (PS) metric by determining its sensitivity and specificity in classifying SP. Materials and Methods Retrospective horizontal and vertical SP test videos and numerical data for 70 participants were obtained from the Neuro Kinetics Neuro-Otologic Test Center and de-identified. From this, eye-tracking videos, time plots of eye-tracking positional data, and tables of SP eye-tracking performance data were generated for 0.1, 0.3, and 0.5 Hz in both horizontal and vertical planes, totaling 6 tests per subject. Three clinicians rated each subject’s SP performance as N, GN, MA, or AB for a total of 6 ratings (3 frequencies, horizontal and vertical). This process was repeated using N, SUBC, and AB as rating categories. Clinicians also provided an overall SP rating for each plane as follows: AB if the results were abnormal for 2 or more frequencies tested. Alternatively, if fewer than 2 frequencies presented with a rating of AB, then an overall rating of MA, GN, or N was determined at the respective clinician’s discretion. Results When the 3 clinicians were tasked with classifying SP videos using 4 clinical categories, fair overall agreement was demonstrated. However, when MA and GN categories were combined into an SUBC category, the overall agreement for the 3 clinicians improved slightly for both horizontal SP (HSP) and vertical SP (VSP). This pattern of agreement did not differ considerably when comparing HSP versus VSP, and good consistency and reliability was observed across clinicians. Again, inter-rater consistency was smaller for VSP versus HSP despite the reduction in clinical categories. Cut-off values were generated for the PS metric and demonstrated good specificity and sensitivity when they were exceeded for 2 or more frequencies in a particular plane when evaluating a subject’s SP test. Conclusions

General & Internal Medicine↗

Discovery of two bright high-redshift gravitationally lensed quasars revealed by Gaia

We present the discovery and preliminary characterisation of two high-redshift gravitationally lensed quasar systems in Gaia Data Release 2 (DR2). Candidates with multiple close-separation Gaia detections and quasar-like colours in WISE, Pan-STARRS, and DES are selected for follow-up spectroscopy with the New Technology Telescope. We confirm DES J215028.71-465251.3 as a $z$ = 4.130 ± 0.006 asymmetric, doubly imaged lensed quasar system and model the lensing mass distribution as a singular isothermal sphere. The system has an Einstein radius of 1.202 ± 0.005 arcsec and a predicted time delay of ~122.0 d between the quasar images, assuming a lensing galaxy redshift of $z$ = 0.5, making this a priority system for future optical monitoring. We confirm PS J042913.17+142840.9 as a $z$ = 3.866 ± 0.003 four-image quasar system in a cusp configuration, lensed by two foreground galaxies. The system is well modelled using a singular isothermal ellipsoid for the primary lens and a singular isothermal sphere for the secondary lens with Einstein radii 0.704 ± 0.006 and 0.241 ± 0.030 arcsec, respectively. A maximum predicted time delay of 9.6 d is calculated, assuming lensing galaxy redshifts of $z$ = 1.0. Furthermore, PS J042913.17+142840.9 exhibits a large flux ratio anomaly, up to a factor of 2.66 ± 0.37 in i band, that varies across optical and near-infrared wavelengths. We discuss LSST and its implications for future high-redshift lens searches and outline an extension to the search using supervised machine learning techniques.

Astronomy & Astrophysics↗

Observation of kinetic mix enhancement in thin-shell OMEGA implosions

Recent separated reactant experiments for thin-shell (6 µ⁢m) shock-driven implosions on OMEGA have demonstrated significant mix from a buried deuterated layer of the shell into the hot spot. Time resolved D 3 He-p reaction history data demonstrate a (50 ± 20)⁢ ps shift earlier in peak nuclear emission for separated reactant experiments relative to control, in contrast to past experimental data for thicker, 20 µ⁢m shells with no laser burn through that show a 75 ps delay due to the time required for hydrodynamic instabilities to develop. This contrast suggests that the mix mechanism was not hydrodynamic. Ion kinetic simulations utilizing fall line analyses show much closer agreement with mix yield and temperature than diffusion models, predicting a D 3 He-p mix yield of 1.7 × 10 9 as compared to the experimental value of 9.3⁢ (±2.1) × 10 8 . This is three orders of magnitude closer than the fall line analysis from a hydrodynamic simulation with an inline diffusive mix model, which suggests minimal mix and D 3 He-p yields of 5×10 5 . This makes kinetic mechanisms the only feasible explanation for the mix seen, demonstrating impact of a non-standard mix mechanism. An analytical model of this kinetic mix mechanism suggests that it can remain significant in situations when the shell expands significantly to low densities, and diffusive models predict negligible mix. Finally, kinetic mix will impact multiple types of high energy density, laser-driven fusion experiments including high-adiabat direct drive cryoexperiments, nuclear cross section experiments, and thin-shell polar direct drive experiments used to tune heat conduction models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Coupled valence carrier and core-exciton dynamics in WS 2 probed by few-femtosecond extreme ultraviolet transient absorption spectroscopy

Few-femtosecond extreme ultraviolet (XUV) transient absorption spectroscopy, performed with optical 500-1000 nm supercontinuum and broadband XUV pulses (30-50 eV), simultaneously probes dynamics of photoexcited carriers in WS$_{2}$ at the W O$_3$ edge (37-45 eV) and carrier-induced modifications of core-exciton absorption at the W N$_{6,7}$ edge (32-37 eV). Access to continuous core-to-conduction band absorption features and discrete core-exciton transitions in the same XUV spectral region in a semiconductor provides a novel means to investigate the effect of carrier excitation on core-exciton dynamics. The core-level transient absorption spectra, measured with either pulse arriving first to explore both core-level and valence carrier dynamics, reveal that core-exciton transitions are strongly influenced by the photoexcited carriers. A $1.2\pm0.3$ ps hole-phonon relaxation time and a $3.1\pm0.4$ ps carrier recombination time are extracted from the XUV transient absorption spectra from the core-to-conduction band transitions at the W O$_{3}$ edge. Global fitting of the transient absorption signal at the W N$_{6,7}$ edge yields $\sim 10$ fs coherence lifetimes of core-exciton states and reveals that the photoexcited carriers, which alter the electronic screening and band filling, are the dominant contributor to the spectral modifications of core-excitons and direct field-induced changes play a minor role. This work provides a first look at the modulations of core-exciton states by photoexcited carriers and advances our understanding of carrier dynamics in metal dichalcogenides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dual-stage structural response to quenching charge order in magnetite

The Verwey transition in magnetite (Fe 3 O 4 ) is the prototypical metal-insulator transition and has eluded a comprehensive explanation for decades. A major element of the challenge is the complex interplay between charge order and lattice distortions. Here we use ultrafast electron diffraction (UED) to disentangle the roles of charge order and lattice distortions by tracking the transient structural evolution after charge order is melted via ultrafast photoexcitation. A dual-stage response is observed in which X 3 , X 1 and Δ 5 type structural distortions occur on markedly different timescales of 0.7-3.2 ps and longer than 3.2 ps. We propose that these distinct timescales arise because X 3 -type distortions strongly couple to the trimeron charge order whereas the Δ 5 -distortions are more strongly associated with monoclinic to cubic distortions of the overall lattice. Our work aids in clarifying the charge-lattice interplay using UED method and illustrates the disentanglement of the complex phases in magnetite.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transient absorption measurements of excitonic dynamics in 3 R -MoS 2

The excitonic dynamics in MoS 2 monolayer, bilayer, and bulk flakes with different stacking orders, namely 3R and 2H, are investigated through transient absorption spectroscopy at room temperature. Samples are obtained by the mechanical exfoliation of bulk MoS 2 crystals with 3R and 2H stacking orders. Photoluminescence spectroscopy is performed to characterize and compare the samples. Time-resolved differential reflection measurements reveal that monolayer flakes exfoliated from the 3R and 2H crystals exhibit similar exciton lifetimes of a few picoseconds. However, the exciton lifetime in the 3R bilayer flake is approximately 85 ps, about twice as long as that in the 2H bilayer. This prolonged exciton lifetime is attributed to the reduction of the electron-hole wavefunction overlap in the 3R bilayer due to the built-in polarization. Similarly, in bulk 3R MoS 2 , the exciton lifetime is around 220 ps, approximately twice as long as those in bulk 2H MoS 2 . The extension of the exciton lifetime in 3R transition metal dichalcogenides could be advantageous for their applications in optoelectronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrafast exciton and trion dynamics in highly 𝑛-doped Mo⁢S 2 monolayers: Many-body effects

Understanding many-body interactions of excitons and charge carriers in monolayer semiconductors is crucial for tuning their unique optical properties and optimizing their performance in optoelectronic devices. However, the sensitivity of these atomically thin semiconductors to doping, defects, and strain–arising from synthesis, substrate, and environmental conditions–hinders consistent observation of many-body effects. In this work, we employed linear and ultrafast transient optical absorption spectroscopy to investigate the influence of background doping on exciton many-body interactions in Mo⁢S 2 monolayers. Using reversible molecular physisorption gating, we achieved a high background doping density of 4.9 × 10 13 c⁢m −2 in an argon environment, which is significantly higher than those attainable with conventional electrical gating. Our results reveal a photoinduced 𝐴-exciton resonance redshift, attributed to band-gap renormalization at a low background-doping density of 4.3 × 10 12 c⁢m −2 in an air environment, transitioning to a blueshift at a high background-doping density of 4.9 × 10 13 c⁢m −2 due to dominant Pauli blocking effects and vertical excitation shifts. We further observed transient energy splitting between free-exciton and -trion states up to 57 meV due to exciton-electron interactions. The ultrafast spectroscopy further revealed exciton and trion dynamics, including fast energy splitting of exciton and trion resonances within 1 picosecond (ps) followed by a rapid decay having a lifetime of ∼5.4 ps. Furthermore, our results demonstrate the critical role of background-doping conditions in tuning many-body interactions and quasiparticle dynamics in 2D semiconductors, providing valuable insights for future device design and material engineering.

Doped semiconductors↗

Analog B ( M 1 ) strengths in the T z = ± 3 2 mirror nuclei Mn 47 and Ti 47

The lifetimes of the first excited 7 2 − states in the T z = ± 3 2 mirror nuclei Mn 47 and Ti 47 have been extracted utilizing the γ -ray line shape method, giving τ = 687 ( 36 ) ps and τ = 331 ( 15 ) ps respectively. Since these transitions are essentially pure M 1 transitions, these results allow for a high-precision comparison of analog M 1 strengths in mirror nuclei. The two analog B ( M 1 ) s are observed to be identical to a precision of about 10 % . The expected dependence of the transition matrix element with T z has been used to extract the separate isoscalar and isovector components of the transition strength, and the results are discussed in the context of predictions, based on the isospin formalism, regarding analog B ( M 1 ) strengths. Published by the American Physical Society 2024

39 ≤ A ≤ 58↗

Measurement of the B 0 lifetime and flavor-oscillation frequency using hadronic decays reconstructed in 2019–2021 Belle II data

We measure the B0 lifetime and flavor-oscillation frequency using B 0 → D(*) – π + decays collected by the Belle II experiment in asymmetric-energy e + ⁢e – collisions produced by the SuperKEKB collider operating at the Υ⁡(4⁢S) resonance. We fit the decay-time distribution of signal decays, where the initial flavor is determined by identifying the flavor of the other B meson in the event. The results, based on 33000 signal decays reconstructed in a data sample corresponding to 190 fb –1 , are τ B 0 = (1.499 ± 0.013 ± 0.008) ps, Δ⁢m d = (0.516 ± 0.008 ± 0.005) ps –1 , where the first uncertainties are statistical and the second are systematic. These results are consistent with the world-average values.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of H Λ 3 and H Λ 4 Lifetimes and Yields in Au + Au Collisions in the High Baryon Density Region

We report precision measurements of hypernuclei $^3_ΛH$ and $^4_ΛH$ lifetimes obtained from Au + Au collisions at $\sqrt{sNN}$ = 3.0 GeV and 7.2 GeV collected by the STAR experiment at the Relativistic Heavy Ion Collider, and the first measurement of $^3_ΛH$ and $^4_ΛH$ midrapidity yields in Au + Au collisions at $\sqrt{sNN}$ = 3.0 GeV. $^3_ΛH$ and $^4_ΛH$, being the two simplest bound states composed of hyperons and nucleons, are cornerstones in the field of hypernuclear physics. Their lifetimes are measured to be 221 ± 15 (stat) ± 19 (syst) ps for $^3_ΛH$ and 218 ± 6 (stat) ± 13 (syst) ps for $^4_ΛH$. The p T -integrated yields of $^3_ΛH$ and $^4_ΛH$ are presented in different centrality and rapidity intervals. It is observed that the shape of the rapidity distribution of $4_ΛH$ is different for 0%–10% and 10%–50% centrality collisions. Thermal model calculations, using the canonical ensemble for strangeness, describes the $^3_ΛH$ yield well, while underestimating the $^4_ΛH$ yield. Transport models, combining baryonic mean-field and coalescence (jam) or utilizing dynamical cluster formation via baryonic interactions (phqmd) for light nuclei and hypernuclei production, approximately describe the measured $^3_ΛH$ and $^4_ΛH$ yields. Our measurements provide means to precisely assess our understanding of the fundamental baryonic interactions with strange quarks, which can impact our understanding of more complicated systems involving hyperons, such as the interior of neutron stars or exotic hypernuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗