Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Oscillation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Generation of mechanical oscillation applicable to vibratory rate gyroscopes

To achieve a drive-axis oscillation with improved frequency and amplitude stability, additional feedback loops are used to adjust force-feedback loop parameters. An amplitude-control loop measures oscillation amplitude, compares this value to the desired level, and adjusts damping of the mechanical sense-element to grow or shrink oscillation amplitude as appropriate. A frequency-tuning loop measures the oscillation frequency, compares this value with a highly stable reference, and adjusts the gain in the force-feedback loop to keep the drive-axis oscillation frequency at the reference value. The combined topology simultaneously controls both amplitude and frequency. Advantages of the combined topology include improved stability, fast oscillation start-up, low power consumption, and excellent shock rejection.

Lemkin, Mark A.↗

Discharge Oscillations in a Permanent Magnet Cylindrical Hall-Effect Thruster

Measurements of the discharge current in a cylindrical Hall thruster are presented to quantify plasma oscillations and instabilities without introducing an intrusive probe into the plasma. The time-varying component of the discharge current is measured using a current monitor that possesses a wide frequency bandwidth and the signal is Fourier transformed to yield the frequency spectra present, allowing for the identification of plasma oscillations. The data show that the discharge current oscillations become generally greater in amplitude and complexity as the voltage is increased, and are reduced in severity with increasing flow rate. The breathing mode ionization instability is identified, with frequency as a function of discharge voltage not increasing with discharge voltage as has been observed in some traditional Hall thruster geometries, but instead following a scaling similar to a large-amplitude, nonlinear oscillation mode recently predicted in for annular Hall thrusters. A transition from lower amplitude oscillations to large relative fluctuations in the oscillating discharge current is observed at low flow rates and is suppressed as the mass flow rate is increased. A second set of peaks in the frequency spectra are observed at the highest propellant flow rate tested. Possible mechanisms that might give rise to these peaks include ionization instabilities and interactions between various oscillatory modes.

Polzin, K. A.↗

80-GHz MMIC HEMT Voltage-Controlled Oscillator

A voltage-controlled oscillator (VCO) that operates in the frequency range from 77.5 to 83.5 GHz has been constructed in the form of a monolithic microwave integrated circuit (MMIC) that includes high-electron-mobility transistors (HEMTs). This circuit is a prototype of electronically tunable signal sources in the 75-to-110-GHz range, needed for communication, imaging, and automotive radar applications, among others. This oscillator (see Figure 1) includes two AlInAs/GaInAs/InP HEMTs. One HEMT serves mainly as an oscillator gain element. The other HEMT serves mainly as a varactor for controlling the frequency: the frequency-control element is its gate-to-source capacitance, which is varied by changing its gate supply voltage. The gain HEMT is biased for class-A operation (meaning that current is conducted throughout the oscillation cycle). Grounded coplanar waveguides are used as impedance-matching transmission lines, the input and output matching being chosen to sustain oscillation and maximize output power. Air bridges are placed at discontinuities to suppress undesired slot electromagnetic modes. A high density of vias is necessary for suppressing a parallel-plate electromagnetic mode that is undesired because it can propagate energy into the MMIC substrate. Previous attempts at constructing HEMT-based oscillators yielded circuits with relatively low levels of output power and narrow tuning ranges. For example, one HEMT VCO reported in the literature had an output power of 7 dBm (.5 mW) and a tuning range 2-GHz wide centered approximately at a nominal frequency of 77 GHz. In contrast, as shown in Figure 2, the present MMIC HEMT VCO puts out a power of 12.5 dBm (.18 mW) or more over the 6-GHz-wide frequency range from 77.5 to 83.5 GHz

Samoska, Lorene↗

Investigation of Combustion Control in a Dump Combustor Using the Feedback Free Fluidic Oscillator

A feedback free fluidic oscillator was designed and integrated into a single element rocket combustor with the goal of suppressing longitudinal combustion instabilities. The fluidic oscillator uses internal fluid dynamics to create an unsteady outlet jet at a specific frequency. An array of nine fluidic oscillators was tested to mimic modulated secondary oxidizer injection into the combustor dump plane. The combustor has a coaxial injector that uses gaseous methane and decomposed hydrogen peroxide with an overall O/F ratio of 11.7. A sonic choke plate on an actuator arm allows for continuous adjustment of the oxidizer post acoustics enabling the study of a variety of instability magnitudes. The fluidic oscillator unsteady outlet jet performance is compared against equivalent steady jet injection and a baseline design with no secondary oxidizer injection. At the most unstable operating conditions, the unsteady outlet jet saw a 67% reduction in the instability pressure oscillation magnitude when compared to the steady jet and baseline data. Additionally, computational fluid dynamics analysis of the combustor gives insight into the flow field interaction of the fluidic oscillators. The results indicate that open loop high frequency propellant modulation for combustion control can be achieved through fluidic devices that require no moving parts or electrical power to operate.

Meier, Eric J.↗

Validation of a Manually Oscillating Chair for In-The-Field Assessment of Dynamic Visual Acuity on Crewmembers Within Hours of Returning from Long-Duration Spaceflight

Due to the deconditioned state of crewmembers in the initial hours after landing, it is safer and more practical to perform a vision test while seated in a chair versus walking on a treadmill. The purpose of this study was to validate the ability of a manually operated oscillating chair to produce the oscillatory frequency and displacement equivalent of walking on a treadmill at a 4 mph pace. A fast Fourier transform (FFT)was performed on the vertical trunk acceleration to compare the peak and spread of the distribution of oscillation frequencies for each oscillating condition. Peak oscillation frequencies achieved with the manual chair were lower and more variable than those of treadmill walking and the automatic chair. This can mostly be attributed to operator fatigue. However, DVA scores across conditions were not significantly different, indicating that the manual chair can provide adequate vertical oscillation frequency and displacement with the added advantage of being portable enough for testing outside a laboratory. Furthermore the automatic chair very closely matches the oscillation frequency of treadmill walking, making it an ideal method for testing DVA in a laboratory setting.

Kreutzberg, G. A.↗

NICER Observation of Unusual Burst Oscillations in 4U 1728-34

The Neutron Star Interior Composition Explorer has observed seven thermonuclear X-ray bursts from the lowmass X-ray binary neutron star 4U 1728-34 from the start of the mission’s operations until 2019 February. Three of these bursts show oscillations in their decaying tail, with frequencies that are within 1 Hz of the previously detected burst oscillations from this source. Two of these burst oscillations have unusual properties: they have large fractional root mean square (rms) amplitudes of 48% ± 9% and 46% ± 9%, and they are detected only at photon energies above 6 keV. By contrast, the third detected burst oscillation is compatible with previous observations of this source, with a fractional rms amplitude of 7.7% ± 1.5% rms in the 0.3 to 6.2 keV energy band. We discuss the implications of these large-amplitude burst oscillations, finding that they are difficult to explain with the current theoretical models for X-ray burst tail oscillations.

Data analysis methods↗

Frequency stabilization in nonlinear MEMS and NEMS oscillators

An illustrative system includes an amplifier operably connected to a phase shifter. The amplifier is configured to amplify a voltage from an oscillator. The phase shifter is operably connected to a driving amplitude control, wherein the phase shifter is configured to phase shift the amplified voltage and is configured to set an amplitude of the phase shifted voltage. The oscillator is operably connected to the driving amplitude control. The phase shifted voltage drives the oscillator. The oscillator is at an internal resonance condition, based at least on the amplitude of the phase shifted voltage, that stabilizes frequency oscillations in the oscillator.

42 ENGINEERING↗

Improving the NOvA 3-Flavour Neutrino Oscillation Analysis

NOvA is a long-baseline neutrino experiment studying neutrino oscillations, a quantum mechanical interference phenomena where the observed neutrino flavour differs from that measured earlier, stemming from neutrino mass and flavour states mixing. NOvA consists of two functionally identical tracking calorimeter detectors deployed in the Fermilab NuMI beam. Both detectors are placed 14.6 mrad off the beam axis to achieve a narrow energy peak at 1.8 GeV at an oscillation maximum. The NOvA 3-flavour oscillation analysis measures the neutrino oscillation parameters sin2θ23 and ∆m232 as well as sets limit to δCP , the octant of θ23 and the sign of ∆m32. The event selection for 3-flavour neutrino oscillation analysis ensures the maximum quantity of signal is made available and a minimal amount of background is present. The current disappearance analysis selection has an efficiency of 80% for selecting νμ CC events, and with some improvements additional events could be recovered into the analysis to improve the sensitivity to the aforementioned oscillation parameters. In an effort to recover the currently rejected signal event to the analysis, these events were trained in a classification neural network. The aim of the network was to divide the data into signal (νμ CC events) and background (NC and νe CC events). The highest performing network gave an additional figure of merit gain of 2.34 increasing the sensitivity by 4.3% in effective POT equal to 33 days of additional data taking. This was compared to changing the current particle identification event selection cuts, the best result out of the tested cut combinations gave an additional FOM of 3.36 equal to 3.7% increase in effective POT equivalent to 28 days of data taking.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Latest Three-Flavor Neutrino Oscillation Results from NOvA

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. NOvA was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data at the far detector. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity beam of neutrinos and anti-neutrinos to the experiment. The NOvA experiments consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the un-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the un-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_e (\bar{\nu}_e)$ events. The most recent measurements of three flavor neutrino oscillation parameters based on an analysis of the data collected from a neutrino-beam exposure of $26.60 \times 10^{20}$ POT and an anti-neutrino beam exposure of $12.50\times 10^{20}$ POT with an additional low energy $\nu_e$ sample, will be presented in this talk.

Singh, Ishwar↗

Latest Constraints on Three-Flavor Neutrino Oscillation Parameters from the NOvA Experiment

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. The NOvA experiment was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data observed at the far detector using a high purity beam of neutrinos and anti-neutrinos from Fermilab's NuMI beamline. The NOvA experiment consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_\mu (\bar{\nu}_\mu) \to \nu_e (\bar{\nu}_e)$ events. The most recent measurements of three flavor neutrino oscillation parameters based on an analysis of the data collected from neutrino-beam exposure of $26.60 \times 10^{20}$ POT and anti-neutrino beam exposure of $12.50\times 10^{20}$ POT including an additional low energy $\nu_e$ sample, will be discussed here.

Choudhary, Brajesh [Delhi U.] (ORCID:0000000150291↗

Measurements of three-flavor neutrino oscillations from a PISCES two-detector fit to the NOvA Experiment data

NOvA is a long-baseline neutrino oscillation experiment with two functionally identical detectors: a Near Detector (ND) at Fermilab, placed 1 km from the neutrino source, and a Far Detector (FD) located 810 km away from the ND in Minnesota. NOvA s primary physics goals are to measure the neutrino oscillation parameters $\theta_{23}$ and $\Delta m^2_{32}$ with high precision, determine the neutrino mass hierarchy, and constrain the value of $\delta_{CP}$, primarily via the study of muon neutrino to electron neutrino oscillation. Extracting values for oscillation parameters from fits to data usually relies on treating systematic uncertainties as nuisance parameters, a strategy that suffers from poor scalability as the number of uncertainties becomes larger. This work introduces PISCES (Parameter Inference with Systematic Covariance and Exact Statistics), a novel method that circumvents this scalability problem by encoding systematic uncertainties into a covariance matrix. PISCES utilizes a nested minimization in which optimal systematic pulls are first computed using the covariance matrix in an inner minimization step, then the oscillation parameters are profiled over in the outer minimization. PISCES also uses a Poisson Likelihood term, making it ideal for the inclusion of low-statistic samples in the fits. PISCES is a flexible framework that also supports complex fits, such as a joint Near and Far detector fit. In the standard NOvA analysis, oscillation parameters are extracted using an extrapolation technique in which the ND data indirectly constrain the FD prediction via a ratio method. PISCES, on the other hand, enables a simultaneous ND+FD fit, allowing the high-statistics ND data to directly constrain systematic uncertainties across all samples. This thesis presents the full PISCES joint ND+FD fit for the NOvA three-flavor analysis, details its implementation, and evaluates its performance through extensive robustness tests and fake data studies. It also provides a comparison between the PISCES joint ND+FD results and the standard NOvA extrapolation method using the full NOvA 10-year data set. The results demonstrate that PISCES can successfully fit NOvA data while incorporating the constraints from the ND detectors consistently, using physically motivated systematic uncertainties to account for data/MC discrepancies.

Rajaoalisoa, Miriama [Cincinnati U.]↗

Stable coaxial-waveguide gyrotron backward-wave oscillator with distributed losses

This study analyzes the performance of a coaxial-waveguide gyrotron backward-wave oscillator (gyro-BWO) operating at the fundamental harmonic by considering mode competition, which may be attributed to higher-order axial modes and competing transverse modes. In the coaxial waveguide with a short length and uniform cross section, the threshold currents of the higher-order axial modes are substantially higher than the operating current. Additionally, when the beam voltage or the magnetic field is adjusted, the oscillation that neighbors the minimum start-oscillation current of a transverse mode has a positive-k{sub z} field profile, and is excited near the cutoff frequency. As a result, the distributed wall losses at the downstream end of the interaction structure effectively damp the positive-k{sub z} field, and raise significantly the minimum start-oscillation currents of the competing transverse modes. This study also investigates how the parameters, including lossy section length, outer wall resistivity, inner wall resistivity, and ratio of the outer radius to the inner radius, affect the start-oscillation currents of the competing transverse modes in order to obtain stable operation conditions in the frequency tuning range. As is forecasted, when using a 15 A electron beam, the Ka-band coaxial gyro-BWO produces an output power of 137 kW and 3 dB bandwidth of 4.2% by magnetic tuning and an output power of 145 kW and 3dB bandwidth of 2.0% by beam voltage tuning.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controlling the betatron oscillations of a wakefield-accelerated electron beam by temporally asymmetric laser pulses

Based on two-dimensional particle-in-cell simulations, we investigated the electron beam's transverse oscillations by temporally asymmetric laser pulses in laser wakefield acceleration. Of particular interest in this article are the effects of ultrashort laser pulses having sharp rising and slow falling time scales. In this situation, the accelerated electron beam interacts directly with the laser field and undergoes transverse oscillations due to a phase-slip with the laser field. This oscillation can be matched with the betatron oscillation due to the focusing force of the ions, which can lead to a large transverse oscillation amplitude due to the resonance between them. Furthermore, in this case, the electron beam can be microbunched at the laser wavelength, which may provide the possibility for generation of a coherent synchrotron radiation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wave functions of log-periodic oscillators

We use the Lewis and Riesenfeld invariant method [J. Math. Phys. 10, 1458 (1969)] and a unitary transformation to obtain the exact Schroedinger wave functions for time-dependent harmonic oscillators exhibiting log-periodic-type behavior. For each oscillator we calculate the quantum fluctuations in the coordinate and momentum as well as the quantum correlations between the coordinate and momentum. We observe that the oscillator with m=m{sub 0}t/t{sub 0} and {omega}={omega}{sub 0}t{sub 0}/t, which exhibits an exact log-periodic oscillation, behaves as the harmonic oscillator with m and {omega} constant.

97 MATHEMATICS AND COMPUTING↗

Plasma oscillations in a 6-kW magnetically shielded Hall thruster

Plasma oscillations from 0–100 kHz in a 6-kW magnetically shielded Hall thruster are experimentally characterized with a high-speed, optical camera. Two modes are identified at 7–12 kHz and 70–90 kHz. The low frequency mode is found to be azimuthally uniform across the thruster face, while the high frequency oscillation is peaked close to the centerline-mounted cathode with an m = 1 azimuthal dependence. An analysis of these results in the context of wave-based theory suggests that the low frequency wave is the breathing mode oscillation, while the higher frequency mode is gradient-driven. The effect of these oscillations on thruster operation is examined through an analysis of thruster discharge current and a comparison with published observations from an unshielded variant of the thruster. Most notably, it is found that although the oscillation spectra of the two thrusters are different, they exhibit nearly identical steady-state behavior.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Frequency jumps in single chip microwave LC oscillators

We report on the experimental observation of oscillation frequency jumps in microwave LC oscillators fabricated using standard complementary metal-oxide-semiconductor technologies. The LC oscillators, operating at a frequency of about 20 GHz, consist of a single turn planar coil, a metal-oxide-metal capacitor, and two cross-coupled metal-oxide-semiconductor field effect transistors used as negative resistance network. At 300 K as well as at 77 K, the oscillation frequency is a continuous function of the oscillator bias voltage. At 4 K, frequency jumps as large as 30 MHz are experimentally observed. This behavior is tentatively attributed to the emission and capture of single electrons from defects and dopant atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Micromagnetic model analysis of integrated single-pole-type head with tilted spin-torque oscillator for high-frequency microwave-assisted magnetic recording

The spin-torque oscillator (STO) is the most important component in microwave-assisted magnetic recording. Some requirements for the STO are: large amplitude and stable oscillation, small injected current, and oscillation at a frequency that excites resonance in a recording medium. It is also necessary for the STO oscillation to closely follow the head coil current. In this paper, STOs were integrated into write heads and micromagnetic analyses carried out to obtain a write head structure with stable STO oscillation that could follow a high-frequency head coil current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrical oscillation in Pt/VO{sub 2} bilayer strips

We report on the observation of stable electrical oscillation in Pt/vanadium dioxide (VO{sub 2}) bilayer strips, in which the Pt overlayer serves the dual purposes of heating up the VO{sub 2} and weakening the electric field in the VO{sub 2} layer. Systematic measurements in an ultrahigh vacuum nanoprobe system show that the oscillation frequency increases with the bias current and/or with decreasing device dimension. In contrast to most VO{sub 2}-based oscillators reported to date, which are electrically triggered, current-induced Joule heating in the Pt overlayer is found to play a dominant role in the generation of oscillation in Pt/VO{sub 2} bilayers. A simple model involving thermally triggered transition of VO{sub 2} on a heat sink is able to account for the experimental observations. The results in this work provide an alternative view of the triggering mechanism in VO{sub 2}-based oscillators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗