Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Evaluation of Properties for Microsample Identification

A study was conducted to determine if individual particle characteristics could be used to identify particles of interest, sub-samples, from bulk post-detonation debris. Three archived post-detonation debris samples were used for this effort. Particles from these samples were identified as active (produced fission tracks), and inactive (did not produce fission tracks), as the first defining characteristic. Morphology was the secondary characteristic to select particles for further study, i.e. spherical/non-spherical. Once particles were identified and isolated, they were characterized by optical microscopy for size in µm, number of fission tracks, morphology, transmitted light color, and reflected light color. Particles were then analyzed by scanning electron microscopy for morphology, elemental content, and compound identification. Raman spectroscopy was attempted on five particles with indeterminate results due to environmental mixing (heterogeneity) during the events of particle formation. Once all non-destructive analyses were completed all particles were analyzed by thermal ionization mass spectrometry to determine isotopic atom percents of plutonium and uranium, and an estimate of atoms of plutonium and uranium in each particle. An estimate of the ratio of uranium to plutonium was also obtained (U/Pu). Data analytics of the data from the particles showed that combining characteristics of the particles have a high probability of identifying particles of interest from bulk post-detonation debris samples. Please note that this version of the report is an abridged version of the full report (Wagnon et al. 2025) that has been edited to be appropriate for public release.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Temperature-tuned ultrafast X-ray shutter using optics-on-a-chip

Typically modulation systems are incapable of performing synchronous modulation for high-energy radiation systems. A method and system for performing high-energy synchronous radiation modulating is described. The method includes providing an oscillatory diffractive element, with the oscillatory diffractive element capable of being oscillated over a range of angles. A radiation source provides radiation to the oscillatory diffractive element. An electrical signal is provided to electrodes that oscillate the oscillatory diffractive element to modulate the radiation. A temperature controller controls the temperature of the oscillatory diffractive element to tune the oscillatory motion of the oscillatory diffractive element.

Wang, Jin↗

Quaternary i-MAX Phases (Mo 2/3 RE 1/3 ) 2 AlC (RE: Dy, Tb, Er): Experimental Characterization and First-Principles Insights into their Fundamental Properties

Rare earth (RE)-based materials have unique electronic, magnetic, and optical properties, leading to the recent discovery of atomically layered solids with the chemical formula (M' 2/3 RE 1/3 ) 2 AlC, which have since garnered significant attention in the scientific community. This study aims to synthesize, characterize, and investigate the structural and thermal stability of the RE i-MAX phases. We prepared i-MAX phases using molybdenum (Mo) as M′ and RE elements as Dy, Tb, and Er, namely (Mo 2/3 Dy 1/3 ) 2 AlC, (Mo 2/3 Tb 1/3 ) 2 AlC, and (Mo 2/3 Er 1/3 ) 2 AlC. Structural characterization through x-ray diffraction (XRD) and Raman spectroscopy confirms the formation of the RE-based i-MAX phase, along with the presence of minor impurity phases in the alloys. Thermogravimetric analysis (TGA) conducted up to 1000°C under ambient conditions reveals that the i-MAX phases remain thermally stable up to approximately 450°C, beyond which oxidation leads to a noticeable weight gain in all samples. Differential scanning calorimetry (DSC) measurements during heating and cooling cycles show endothermic and exothermic peaks for (Mo 2/3 Dy 1/3 ) 2 AlC i-MAX in the 410–420°C range, indicating a temperature-induced minor atomic arrangement. In contrast, these peaks are absent in the Tb- and Er-based i-MAX phases. These findings offer valuable insights into the thermal behavior and stability of these i-MAX phases under thermal stress, contributing to a deeper understanding of their unique properties. Furthermore, first-principles density functional theory (DFT) calculations were performed to investigate the electronic and optical properties of the i-MAX phases. The results reveal their metallic nature, with pronounced contributions from Mo and RE elements near the Fermi level and within the conduction band.

Rare earth↗

HPE ultralit project (ARPA-E open program 2018) final report 15

The goal of the program was to build a fully integrated optical transceiver with >1 Tb/s and <1.5 pJ/bit operating at 50 ◦ C. Optical transceivers are critical components in high-performance-computers (HPC) and data centers, and the details of their implementation has a big impact on the total power consumption (energy efficiency) of an HPC system. Our proposed transceiver used three key enabling technologies. Firstly, SiGe avalanche photodetectors have record-low sensitivities, meaning that they can reach low bit error rates with very little light input. As a result, we can drive our lasers at a lower drive current, thus saving electrical power. Secondly, we use MOS-based capacitive tuning in our deinterleaver, modulator, and demultiplexer. Capacitive tuning allows for the tuning of photonic elements with zero static power consumption. Thirdly, we use quantum dots as the gain material in our light source. This allows us to efficiently use our light source at temperatures that are typically encountered in an HPCsystem. Our proposed optical transceiver consisted of a quantum dot comb laser as a light source, a booster SOA, MOS-based deinterleavers, MOS based ring modulators, MOS-based ring demultiplexers, and SiGe APDs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Shape-Controlled Synthesis of Copper Nanocrystals for Plasmonic, Biomedical, and Electrocatalytic Applications

As a metal that can occur in nature in the elemental form, copper (Cu) has been used by humans since ca. 8000 BC. With most properties matching those of Ag and Au, Cu has played a more significant role in commercial applications owing to its much higher (the 25th among all elements) abundance in Earth’s crust and thus more affordable price. In addition to its common use as a conductor of heat and electricity, it is a constituent of various metal alloys for hardware, coins, strain gauges, and thermocouples. Bulk Cu is also widely utilized as a building material. When downsized to the nanoscale, Cu and Cu-based structures have found widespread use in applications ranging from electronics to optoelectronics, plasmonics, catalysis, sensing, and biomedicine. Besides Ag and Au, for example, Cu is another metal known for its localized surface plasmon resonance (LSPR) in the visible and near-infrared regions when prepared as nanocrystals. As a potential replacement for indium–tin oxide (ITO) films, polymer coatings containing Cu nanowires are strong candidates for the fabrication of transparent and flexible electrodes key to touchscreen display and related applications. The commercial catalysts for water–gas shift and gas detoxification reactions are also based on Cu nanoparticles. Most recently, Cu nanocrystals have attracted considerable interest for their superior selectivity toward hydrocarbons and multicarbon species during the electrochemical reduction of CO 2 . The success of all these applications critically depends on our ability to control the shape and surface structure of the nanocrystals. Relative to Ag and Au, it is more challenging to generate Cu-based nanocrystals using colloidal methods due to its lower reduction potential and greater vulnerability to oxidation. Here, in this account, we discuss recent progress in the colloidal synthesis of Cu nanocrystals with controlled shapes for plasmonic, biomedical, and catalytic applications. With glucose serving as a reducing agent, Cu nanocrystals bearing a twinned or single-crystal structure can be synthesized using an aqueous system with the assistance of hexadecylamine (HDA). In this synthetic protocol, HDA not only passivates the surface to protect the nanocrystals from oxidation but also manipulates the reduction kinetics of Cu(II) precursor through coordination and an increase of solution pH. Typical products include nanocubes and penta-twinned nanowires whose surfaces are dominated by {100} facets. When seeds produced either in situ or ex situ are introduced, Cu-based nanocrystals featuring a singly twinned, core–shell, or Janus structure can be readily synthesized. Aside from segmented structures, Cu-based alloys with various noble metals can be synthesized through coreduction or a galvanic replacement reaction with preformed Cu nanocrystals. By controlling the size and/or shape of Cu nanocrystals, their LSPR peaks can be tuned into the near-infrared region, making them promising candidates for optical imaging contrast enhancement and photothermal treatment. The inclusion of the 64 Cu isotope makes them immediately useful in positron emission tomography and thus image-guided therapy. The surface structure, elemental distribution, and valence state of Cu-based nanocrystals can all be tailored to augment their electrocatalytic performance. It is hoped that this Account will inspire more studies into the development of rational methods capable of producing Cu-based nanocrystals with diverse and well-controlled shapes, internal structures, and compositions for a broader range of applications.

36 MATERIALS SCIENCE↗

Establishing a process-structure-property-performance framework for SLS additive manufacturing through integrated multiscale modeling

This study presents a comprehensive suite of high-fidelity computational models that integrate multiscale and multiphysics simulations to capture the full Selective Laser Sintering (SLS) additive manufacturing process—from initial melting and solidification to mechanical response under external loads. Process simulations are linked with mechanical analysis through Representative Volume Elements (RVEs), establishing a process-structure–property-performance framework. The interaction between laser light and polyamide 12 (PA12) powder is modeled, accounting for laser characteristics and the optical, thermal, and geometrical properties of the powder. The heat source is incorporated into a heat transfer model, coupled with crystallization kinetics and densification models to predict material density and crystallinity. The porosity distribution from the densification model and crystallinity interpolated from experimental data are used to construct the RVEs. A multi-mechanism constitutive model is then calibrated using mechanical tests to predict the stress–strain response. Simulation results show good agreement with experimental data in terms of porosity, crystallinity, and mechanical performance when sufficient laser power (62 W or higher) is used. This research supports the inverse design of 3D-printed structures by introducing a high-fidelity framework that combines multiscale and multiphysics modeling with experimental calibration for predictive and performance-driven additive manufacturing.

SLS↗

Topology and spectral entanglement in cavity-mediated photon scattering

Here, we develop a microscopic diagrammatic theory for cavity-mediated photon scattering in a topological one-dimensional insulator described by the Su–Schrieffer–Heeger model. Within the velocity-gauge formulation, we derive the photon self-energy and vertex corrections arising from virtual electron–hole excitations coupled to a quantized cavity mode, and we evaluate the resulting polariton dispersion and two-photon correlation spectra. Our analysis shows that vacuum fluctuations of the cavity field induce a momentum-resolved self-energy that mixes conduction and valence bands through virtual photon exchange, producing interband hybridization and avoided crossings in the electronic dispersion. This “cavity dressing” is symmetry-dependent, vanishing at the Brillouin-zone edge where the dipole matrix element is zero, and its strength is controlled by the spatial coherence range ζ ≈ (l c /a) 2 of virtual excitations. We further examine how the cavity modifies nonlinear optical observables, including the Kerr nonlinearity and biphoton spectral entanglement, and identify the regimes where these effects become sensitive to the underlying topological phase. The theoretical framework established here provides a unified description of light–matter coupling in topological and polaritonic systems, bridging solid-state cavity QED with the emerging field of cavity-modified quantum materials. Our results suggest that engineered photonic environments can coherently reshape the electronic landscape of topological insulators, offering new routes to control collective electronic and optical phenomena through vacuum-field fluctuations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Simulating Dopant Diffusion in a Detalied Porous Structure

The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) uses highpowered lasers to explore cutting edge fusion technology. Specialized optics, known as fiber lasers, generate and amplify the NIF’s high-powered lasers that facilitate fusion experiments. Fiber lasers are glass fibers that are doped with heavy elements to stimulate light emission. The fiber laser doping processing uses a predeposited layer of porous silica nanoparticles on the surface of the glass to absorb a dopant rich salt solution. Our project simulated the diffusion of dopants into porous silica with prescribed colloidal stacking geometries using COMSOL Multiphysics. With these simulations we identified the porosity and tortuosity of the porous nanoparticle structures as the primary parameters that will dictate how the dopants will diffusive into the porous surface of the glass. Porosity and Tortuosity are geometric parameters that can easily be input into more detailed simulations to estimate an effective diffusivity within the porous layer. Future work should account for surface reactions to accurately simulate the full-scale diffusion of the solution doping process.

36 MATERIALS SCIENCE↗

Optimization of Conditions for Photoluminescence-Based Sensing of Critical Minerals: Strategies and Outlook

Economically critical minerals and metals are vital to America’s security, with application areas in energy, advanced technologies, and defense systems. The growing implementation of renewable energy sources such as electric vehicles is expected to significantly increase demand for these minerals, while the global supply is monopolistic, with most of the production occurring in a few countries outside of the US. To mitigate potential supply chain vulnerabilities, the domestic production of economically critical metals has become a bipartisan priority of the US government, and unconventional sources such as coal and its utilization byproducts such as fly ash and acid mine drainage are being actively explored as an alternative method for meeting domestic demand. Slow and expensive characterization methods for critical metals present a significant pain point for domestic production, which has led to the exploration of alternative low-cost, portable platforms capable of detecting target metals during resource prospecting and downstream process monitoring. The National Energy Technology Laboratory has developed a portable fiber optic-based luminescence spectrometer that utilizes a metal-organic framework (MOF) material to detect and distinguish parts-per-billion levels of the visible-emitting rare earth elements terbium, dysprosium, samarium, and europium, which are all economically critical metals. Although preliminary results with this system are promising, a crucial barrier to practical deployment is the ability to operate in low pH, high ionic strength environments, as acidic conditions and the presence of other metal ions can significantly reduce luminescence signal. Here, current strategies related to sample treatment, material design, and sensor configuration are discussed in the context of improving sensor performance in application-relevant conditions. Additionally, future opportunities, such as the optimization of the sensing binding environment through computational methods and specific metals to be removed for treatment will be discussed, presenting a forward-looking view for innovation in luminescent sensing of critical metals.

36 MATERIALS SCIENCE↗

Nanoscale optical tomography with cathodoluminescence spectroscopy

In one aspect, a cathodoluminescence (CL) spectroscopic tomography device includes a sample stage to support a sample. An electron beam source scans an electron beam over the sample to yield light emission by the sample. A reflective element directs the light emission by the sample to a light detector. A controller controls operation of the sample stage, the electron beam source, and the light detector. In one aspect, a CL spectroscopic tomography device includes an electron beam source which directs an electron beam at an object to yield an emission by the object. A detector detects the emission. A controller receives information from the detector related to the detected emission. The controller derives a two-dimensional (2D) CL map from the information related to the detected emission, and derives a three-dimensional (3D) CL tomogram from the 2D CL map.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-objective, robust constraints enforced global topology optimizer for optical devices

A method for optimization of photonic devices is disclosed. The method includes receiving a set of unconstrained latent variables; mapping the set of unconstrained latent variables to a constrained space to generate a constrained device; calculating the permittivity across each element of the constrained device; determining a permittivity-constrained width gradient based at least partially on the permittivity across each element; and optimizing the set of unconstrained latent variables by at least partially using the permittivity-constrained width gradient.

Fan, Jonathan↗

System and method for using mechanical loading to create spatially patterned meta surfaces for optical components

The present disclosure relates to a system for producing a patterned nanostructured surface on a component from a pre-existing, nanostructured surface with a first spatial feature distribution on the component. The system makes use of a force application element configured to apply a force to the pre-existing, nanostructured surface, and a force application control subsystem. The force application control subsystem is configured to control elevational movement of the force application element along a first axis of movement into and out of contact with the pre-existing, nanostructured surface to apply a predetermined load to the pre-existing, nanostructured surface. The predetermined load is sufficient to modify the pre-existing, non-patterned nanostructured surface to create the patterned nanostructured surface.

Ray, Nathan James↗

Enhanced tuneable rotatory power in a rotating plasma

We report that the gyrotropic properties of a rotating magnetized plasma are derived analytically. Mechanical rotation leads to a new cutoff for wave propagation along the magnetic field, and polarization rotation above this cutoff is the sum of the classical magneto-optical Faraday effect and the mechanico-optical polarization drag. Exploiting the very large effective group index near the cutoff, we expose here that polarization drag can be 10 4 larger than Faraday rotation at GHz frequency. The rotation leads to weak absorption while allowing direct frequency control, demonstrating the unique potential of rotating plasmas for nonreciprocal elements. The very large rotation frequency of a dense non-neutral plasma could enable unprecedented gyrotropy in the THz regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technology of thin-rod Yb : YAG amplifiers with a high pulse energy and average power

Technology for producing thin-rod Yb : YAG laser amplifiers is improved, which is aimed at increasing the output pulse energy and includes the development of a new method for mounting active elements into a cooling system and employment of more persistent dielectric coatings of rod ends. An influence of a thermal lens on the beam size in an active element is theoretically studied and the parameters are found, which provide equal beam sizes at input and output rod ends. The output pulse energy of 4 mJ is obtained without optical breakdown of the output end, which substantially exceeds the previously obtained results. The amplifier demonstrates an average power of 60 W and maintains a high beam quality. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The APOGEE value-added catalogue of Galactic globular cluster stars

ABSTRACT We introduce the Sloan Digital Sky Survey (SDSS)/ Apache Point Observatory Galactic Evolution Experiment (APOGEE) value-added catalogue of Galactic globular cluster (GC) stars. The catalogue is the result of a critical search of the APOGEE Data Release 17 (DR17) catalogue for candidate members of all known Galactic GCs. Candidate members are assigned to various GCs on the basis of position in the sky, proper motion, and radial velocity. The catalogue contains a total of 7737 entries for 6422 unique stars associated with 72 Galactic GCs. Full APOGEE DR17 information is provided, including radial velocities and abundances for up to 20 elements. Membership probabilities estimated on the basis of precision radial velocities are made available. Comparisons with chemical compositions derived from the GALactic Archaeology with HERMES (GALAH) survey, as well as optical values from the literature, show good agreement. This catalogue represents a significant increase in the public data base of GC star chemical compositions and kinematics, providing a massive homogeneous data set that will enable a variety of studies. The catalogue in fits format is available for public download from the SDSS-IV DR17 value-added catalogue website.

Schiavon, Ricardo P. (ORCID:0000000222440897)↗

Experimental Investigation of Low-Frequency Distributed Acoustic Sensor Responses to Two Parallel Propagating Fractures

Low-frequency distributed acoustic sensing (LF-DAS) is a diagnostic tool for hydraulic fracture propagation with far-field monitoring using fiber optic sensors. LF-DAS senses strain rate variation caused by stress field change due to fracture propagation. Fiber optic sensors are installed in the monitoring wells in the vicinity of a fractured well. From the strain responses, fracture propagation can be evaluated. To understand subsurface conditions with multiple propagating fractures, a laboratory-scale hydraulic fracture experiment was performed simulating the LF-DAS response to fracture propagation with embedded distributed optical fiber strain sensors under these conditions. The experiment was performed using a transparent cube of epoxy with two parallel radial initial flaws centered in the cube. Fluid was injected into the sample to generate fractures along the initial flaws. The experiment used distributed high-definition fiber optic strain sensors with tight spatial resolutions. The sensors were embedded at two different locations on opposite sides of the initial flaws, serving as observation/monitoring locations. We also employed finite element modeling to numerically solve the linear elastic equations of equilibrium continuity and stress–strain relationships. The measured strains from the experiment were compared to simulation results from the finite element model. The experimentally derived strain and strain-rate waterfall plots from this study show the responses to both fractures propagating, while the fracture at the lower position took most of the fluid during the experiment. Interestingly, a fracture first began propagating from the upper flaw of the two flaws, but once the lower fracture was initiated, it grew much faster than the upper fracture. Both fibers were intercepted by the lower fracture, further verifying the strain signature as a fracture is approaching and intersecting an offset fiber.

Chemistry↗

Bandwidth extension and conversion efficiency improvements beyond phase matching limitations using cavity-enhanced OPCPA

The conversion efficiency and phase matching bandwidth of ultrafast optical parametric amplification (OPA) are constrained by the dispersion and nonlinear coefficient of the employed crystal as well as pulse shaping effects. In our work we show that an enhancement cavity resonant with the pump seeded at the full repetition rate of the pump laser can automatically reshape the small-signal gain in optical parametric chirped-pulse amplification (OPCPA) to achieve close-to-optimal operation. This new method termed cavity-enhanced OPCPA or C-OPCPA significantly increases both the gain bandwidth and the conversion efficiency, in addition to boosting gain for high-repetition-rate amplification. The goal in C-OPCPA is to arrive at a condition of impedance matching at all temporal coordinates, such that, in the absence of linear losses, all the incident pump power is dissipated in the nonlinear loss element, i.e., converted to signal and idler. The use of a low finesse enhancement cavity resonant with a low average power (<1W) and a high repetition rate (78MHz) pump source is shown to achieve more than 50% conversion efficiency into signal and idler from the coupled pump in an optical parametric process, whereas an equivalent amount of pump power in a single-pass configuration leads to negligible conversion. Additionally, the gain bandwidth is extended by a factor of 3-4 beyond the phase-matching limit. Our empirical observations are corroborated by a numerical analysis of depletion optimizing the single-pass case, which assesses the underlying impedance matching that is responsible for the observed performance improvements.

47 OTHER INSTRUMENTATION↗