At least 505 records · Page 28

ELG×LRG Distribution through Dark Matter Halo Dynamics

We investigate the clustering and halo occupation distribution (HOD) of DESI Y1 emission-line (ELGs) and luminous red (LRGs) galaxies at 0.8 < z < 1.1, including their cross-correlation (ELG×LRG), using the A BACUS S UMMIT suite and a new Halo Occupation Model (H OME ) for galaxy multitracers. This integrates intrahalo dynamics, halo exclusion, and quenching, bridging insights from hydrodynamical, HOD, abundance-matching, and semianalytic studies. Leveraging full phase-space information from the Uchuu N-body simulation, and sampling satellites from dark-matter particle positions via physically motivated prescriptions, Home reproduces the anisotropic clustering down to s = 200 h −1 kpc with unprecedented accuracy. Model parameters are inferred solely from two-point statistics using a two-level Bayesian framework, yielding high-fidelity ELG, LRG, and cross-reference catalogs. We find that satellite ELGs behave as incoherent flows within their parent halos, dominating the clustering below 4 h −1 Mpc. The HOD from the best-fit Home has the following properties: (i) 90.50% (85.91%) of ELGs (LRGs) are central galaxies without satellites, residing in halos of M vir ∼ 6.6 × 10 11 (1.2 × 10 13 ) h −1 M ⊙ ; (ii) the ELG×LRG cross-correlation is governed by central-central pairs and shaped by halo exclusion on 2–5 h −1 Mpc scales; (iii) 9.50% (14.09%) of ELGs (LRGs) are satellites, of which 1.09% (3.52%) inhabit halos with a central galaxy of the same species in a maximally conformal configuration, 7.02% (0.005%) orbit complementary hosts in a minimally conformal state, and 0.58% (10.57%) are orphans. The high sensitivity of Home precisely captures the dynamics of satellites in different host environments, opening a promising avenue for understanding systematics and the dynamical nature of dark matter, potentially distinguishing gravity models.

Favole, Ginevra [Universidad de La Laguna (Spain);↗

Are Deep Energy Retrofits in Commercial Buildings Including Window Upgrades?

U.S. Commercial buildings account for about 20% of total U.S. energy consumption. Because the thermal performance of windows significantly affects building energy efficiency and HVAC system performance, best practice guidance often includes window and envelope improvements in conjunction with HVAC upgrades to optimize energy use and improve occupant comfort. It is an open question, however, regarding how often these best practices are implemented in the field. This paper aims to address that gap by conducting a literature review and a series of interviews with commercial building auditing and management professionals to explore the factors that drive window retrofits in commercial buildings. The paper explores a range of case studies from deep energy retrofits across the globe, comparing projects with and without window retrofits. The primary goals of this review are to: (1) provide data from real-world case studies illustrating the role of windows in deep energy renovations and HVAC upgrades, (2) conduct retrofit cost analyses for windows and high-performance HVAC systems and (3) offer insights into how window upgrade decisions are made and when they are implemented as part of deep energy retrofits. Most of the retrofit studies focused exclusively on high performance HVAC upgrades without considering how window upgrades might further enhance the overall energy efficiency of commercial buildings. Interviews with building industry experts shed light on the key factors influencing deep energy retrofit decisions and what factors tip the scales in favor of including window measures with more comprehensive retrofit projects.

Cort, Katherine↗

A Convergence of Public-Private Benefits in Denver: Surveys and Analyses to Inform Urban Mobility-, Energy-, Infrastructure- and Behavior-Related Innovation: Preprint

Cities, public transit agencies, and new private ride hailing services seek to understand emerging traveler dynamics, the shifting demographics of urban travelers,and new energy-efficient mobility opportunities. This includes exploring how new infrastructure investments, public and private mobility services, and smart-phone mobility apps are reshaping behaviors, demands (e.g. mobility-on-demand services), travel experiences and energy-efficient urban travel preferences. Currently, cities and metropolitan regions are providing and experimenting with many new mobility options, technologies, and personalized information services at the intersection of urban mobility, energy, and infrastructure systems (e.g., new commuter rail). To date, technology alone has not been able to crack the nut of 'creating faster trip times, less congestion, safer streets, and cleaner air for its citizens through fewer cars on the road'. This paper focuses on this gap by offering new concepts and potential for integrated approaches. Accommodating more vehicles miles traveled in cities, without increases in person miles traveled (PMT), could be costly, generating: 1) tremendous demands for new infrastructure, land, road space, materials, and energy; 2) higher traffic fatality risks; and 3) worsening air quality. Therefore, this study focuses on reducing single occupancy vehicle use by enhancing integrated mobility, helping transit and ridehailing increase occupancy in ways that also reduce energy use, and improve quality of life for urban travelers and communities. This study focuses on a survey of urban travelers in Denver, as a representative case study for metropolitan regions experiencing rapid growth, ageing populations, increased urban sprawl, traffic-related delays, and inefficient energy use per PMT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Low-Power Time-to-Digital Converter for the CMS Endcap Timing Layer (ETL) Upgrade

We present the design and test results of a Time-to-Digital-Converter (TDC). The TDC will be a part of the readout ASIC, called ETROC, to read out Low-Gain Avalanche Detectors (LGADs) for the CMS Endcap Timing Layer (ETL) of High-Luminosity LHC upgrade. One of the challenges of the ETROC design is that the TDC is required to consume less than 200 W for each pixel at the nominal hit occupancy of 1%. To meet the low-power requirement, we use a single delay line for both the Time of Arrival (TOA) and the Time over Threshold (TOT) measurements without delay control. A double-strobe self-calibration scheme is used to compensate for process variation, temperature, and power supply voltage. The TDC is fabricated in a 65 nm CMOS technology. The overall performances of the TDC have been evaluated. The TOA has a bin size of 17.8 ps within its effective dynamic range of 11.6 ns. The effective measurement precision of the TOA is 5.6 ps and 9.9 ps with and without the nonlinearity correction, respectively. The TDC block consumes 97 W at the hit occupancy of 1%. Over a temperature range from 23 C to 78 C and a power supply voltage range from 1.05 V to 1.35 V (the nominal value of 1.20 V), the self-calibrated bin size of the TOA varies within 0.4%. The measured TDC performances meet the requirements except that more tests will be performed in the future to verify that the TDC complies with the radiation-tolerance specifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Incorporating Residential Smart Electric Vehicle Charging in Home Energy Management Systems: Preprint

Electric vehicles are expected to drastically increase residential electricity consumption and provide a significant source of flexible demand. Aggregating smart EV charge controllers with other smart home devices through a home energy management system can lead to more optimal outcomes that benefit homeowners, utilities, and grid operators. Control strategies must account for occupant convenience by considering the need for fully charged EVs at any time of day. In this paper, we develop an EV charging framework that accounts for occupant convenience using OCHRE, a residential energy model, and foresee, a home energy management system. We simulate a community with high EV penetration and show that integrated, smart EV charging reduces peak demand and smooths night-time energy consumption. Simulation results show that the proposed control strategy nearly eliminates peak period EV charging and reduces the daily peak demand from EVs by 23%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Configurable vehicle seat and method therefor

A conformal seat insert for an adjustable vehicle seat, the conformal seat insert comprising an insert frame, the insert frame having one or more insert reference features for locating the insert frame on a seat frame of the vehicle seat in a predetermined position relative to the seat frame, and a contoured support surface formed in the insert frame, the contoured support surface having a crew reference point corresponding to an acromial point of a shoulder of a seat occupant of the adjustable vehicle seat, the crew reference point being a datum from which an eye position of the seat occupant is established relative to instrumentation of an aerospace vehicle in which the adjustable vehicle seat is located.

McCarley, Michael C.↗

Healthy Buildings Guide for Small Businesses: A Quick Reference to Improve Indoor Air Quality (Restaurants Excluded)

Indoor air pollutant concentrations can be higher than those outdoors, putting occupants at risk. These pollutants come from a variety of sources: materials used to build and furnish indoor spaces, retail products and services, and occupants themselves. Ventilation, temperature, and humidity also affect indoor air quality. It is important to consider the documented benefits of healthy indoor environments at any time – not just during a public health crisis – and it is key to consider the indoor air quality where we do business as well as at home. Small businesses vary in size, services, products, ownership style, and building mechanical systems, yet all benefit from healthy indoor spaces for employees and customers. This guide provides steps, in conjunction with public health guidance, that small businesses can take to improve and maintain indoor air quality. Small businesses often have unique ownership structures – the building owner and business owner can be different parties – so this guide addresses both building and business owner action items. There are many ways to pursue healthy indoor air, including eliminating, minimizing, and/or controlling the contaminants we bring in, and removing or diluting any existing contaminants through ventilation, filtration, air cleaning, and/or disinfection. Best results are achieved through a comprehensive approach combining various strategies, including those discussed in this guide.

air filtration↗

Building Energy Modeling Enhancements to Identify Least-Cost Pathways to Net-Zero Carbon Homes: Preprint

Residential grid-interactive efficient buildings (GEBs) can utilize high levels of energy efficiency and demand flexibility to deliver value to occupants, the grid, and society. However, without the ability to analyze, design, and optimize residential GEBs there is a risk that homes will not realize their full potential value as efficient and dynamic resources, which could ultimately lead to higher than necessary energy costs for U.S. households and lower realization of potential energy efficiency and demand flexibility benefits such as increased convenience/automation, thermal comfort, durability, indoor air quality, and resilience. In 2018, the National Renewable Energy Laboratory (NREL) Residential Modeling Team developed a vision for an open source Residential GEB Analytics Platform built within DOE's EnergyPlus and OpenStudio modeling environment that would enable the design and optimization of residential GEBs, including the identification of least-cost pathways to highly energy-efficient and energy-flexible homes (e.g., net zero carbon homes). We created a detailed workplan for the development of new and enhanced residential GEB component-level models for EnergyPlus and OpenStudio needed to progress toward the vision for the analytics platform while delivering near-term benefits to industry. This paper 1) presents the vision for the platform, summarizing the workplan for residential GEB modeling enhancements; 2) highlights significant advancements that have been achieved between 2018 and 2022, including stochastic residential occupancy modeling, flexible water heater modeling, detailed lithium-ion stationary battery modeling, and realistic residential HVAC modeling; and 3) outlines ongoing efforts and next steps toward the full vision for the platform.

building energy modeling↗

Guia de Edificios Saludables para Pequenas Empresas: Una Referencia Rapida para Mejorar la Calidad del Aire Interior (Restaurantes Excluidos)

Indoor air pollutant concentrations can be higher than those outdoors, putting occupants at risk. These pollutants come from a variety of sources: materials used to build and furnish indoor spaces, retail products and services, and occupants themselves. Ventilation, temperature, and humidity also affect indoor air quality. It is important to consider the documented benefits of healthy indoor environments at any time - not just during a public health crisis - and it is key to consider the indoor air quality where we do business as well as at home. Small businesses vary in size, services, products, ownership style, and building mechanical systems, yet all benefit from healthy indoor spaces for employees and customers. This guide provides steps, in conjunction with public health guidance, that small businesses can take to improve and maintain indoor air quality. Small businesses often have unique ownership structures - the building owner and business owner can be different parties - so this guide addresses both building and business owner action items. There are many ways to pursue healthy indoor air, including eliminating, minimizing, and/or controlling the contaminants we bring in, and removing or diluting any existing contaminants through ventilation, filtration, air cleaning, and/or disinfection. Best results are achieved through a comprehensive approach combining various strategies, including those discussed in this guide.

air filtration↗

User Friendly Web-Based Tool to Assess the Energy Efficiency and Durability of Residential Wall Retrofits

According to the U.S. Department of Energy Windows and Building Envelope Research and Development Roadmap for Emerging Technologies, building envelope wall energy loss in the United States accounts for about 5.9 x 1010 kWh or 2 quads of energy annually, costing homeowners and occupants billions of dollars. Enclosure retrofits targeting these losses can save significant energy, reduce greenhouse gas emissions, and save occupants millions of dollars over time. Older homes, built before 1992 when DOE’s Building Energy Codes Program was established, represent approximately 68 percent of the residential building stock in the country, often having significant air leakage and inadequate insulation. Homes with little to no air sealing or insulation have heating and cooling losses that can represent a substantial portion of utility bills.High-performance building envelope retrofit systems are rarely selected for retrofit applications. Current solutions are expensive and/or unfamiliar to many designers, builders, contractors, and code officials and therefore are perceived as risky. The dominant perceived risk is durability specifically related to condensation and moisture accumulation in the building envelope component.The Building Science Advisor (BSA) is a rule-based expert system web-based tool that was originally developed to assist building professionals in designing energy efficient and durable wall systems for new construction. With the present focus being placed on upgrading the existing building stock, a retrofit module has been developed that, based on the location, existing construction, and planned retrofit strategy, provides recommendations on how to address the retrofit in a manner that will perform in accordance with IECC 2018 building code and not create a durability problem. This paper will describe the development of this tool and demonstrate its features and capabilities.

Desjarlais, Andre Omer↗

What does it take to “see” air leakage through a building envelope?

Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.

Boudreaux, Philip↗

Building Alternative Indices of Socioeconomic Status for Population Modeling in Data-Sparse Contexts (Short Paper)

Population modeling requires clear definitions of socioeconomic status (SES) to ensure overall estimate accuracy and locate potentially underserved subpopulations. This presents a challenge as SES can be measured in myriad ways and for divergent purposes, and the data required to calculate these metrics may be lacking, particularly in low and middle income countries (LMICs). To support more refined SES measurement, we explore improvements upon the Demographic and Health Survey’s (DHS) Wealth Index (DHS-WI) using alternative characterizations of SES based on multiple correspondence analysis (MCA) and hierarchical clustering. We produce the MCA-derived metrics first on a full suite of household economic, demographic, and dwelling variables, then on a reduced set of occupant-only SES characteristics. We explore the utility of these metrics relative to DHS-WI based on their ability to 1) differentiate DHS household types and 2) identify mixtures of SES levels within DHS samples and mapped at high spatial resolution. We find that our full suite MCA yields more clearly defined SES segments and that our reduced MCA delineates occupant SES most clearly, suggesting potential pathways to improve upon the DHS-WI in future population modeling efforts for LMICs.

Cunningham, Angela↗

Configurable vehicle seat and method therefor

An adjustable vehicle seat including a seat frame forming a seat back, the seat frame being configured to couple with an aerospace vehicle, and a seat pan coupled to the seat frame, where one or more of the seat frame and the seat pan is configured to couple the seat pan to the seat frame in one of a plurality of positions relative to the seat frame so that an eye position of a seat occupant relative to instrumentation within the aerospace vehicle is decoupled from a size of the seat occupant.

McCarley, Michael C.↗

Intern Sized Poster for Dosimetry Research

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intern Sized Poster for Dosimetry Research

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray Security Imaging on Personal Dosimetry

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gaining Real-Time Water Leak Detection

Devens Reserve Forces Training Area is a United States Army Reserve (USAR) Installation that struggles with severe water leaks, often causing significant damage to the facility and requiring major renovation. Traditional water use is highly dependent on occupancy, so it can be difficult to benchmark a facility’s water use. It can be exceptionally difficult when occupancy is transient and/or varies. Pacific Northwest National Laboratory (PNNL) collaborated with Devens to implement real-time monitoring of their water consumption by utilizing the smart meter data from their existing 23 water meters. PNNL created a simple algorithm to calculate hourly water consumption and trigger an alert to be instantly emailed to Devens’ personnel when there appears to be a water leak in any building with a smart water meter. Here, this approach is expected to save hundreds of thousands of dollars in unnecessary water consumption costs and damages from leaks and was implemented with little-to-no costs or service disruptions. Next steps for this project include slow leak detection through nighttime monitoring and to extrapolate this water leak approach to the remainder 360 water meters on USAR’s Enterprise Building Control System so USAR sites across the country can be instantly notified of potential water leaks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proactive and Reactive Thermal Comfort Behaviors

The expansion of renewable electricity generation, growing demands due to electrification, greater prevalence of working from home, and increasing frequency and severity of extreme weather events, will place new demands on the electric supply and distribution grid. Broader adoption of demand response programs (DRPs) for the residential sector may help meet these challenges; however, experience shows that occupant overrides in DRPs compromises their effectiveness. There is a lack of formal understanding of how discomfort, routines, and other motivations affect DRP overrides and other related human building interactions (HBI). This paper reports preliminary findings from a study of 20 households in Colorado and Massachusetts, US over three months. Participants responded to ecological momentary assessments (EMA) triggered by thermostat interactions and at random times throughout the day. EMAs included Likert-scale questions of thermal preference, preference intensity, and changes to 7 different activity types that could affect thermal comfort, and an opened ended question about motivations of such actions. Twelve tags were developed to categorize motivation responses and analyzed statistically to identify associations between motivations, preferences, and HBI actions. Reactions to changes in the thermal environment were the most frequently observed motivation (118 of 220 responses). On the other hand, almost half (47%) responses were at least partially motivated by non-thermal factors, suggesting limited utility for occupant behavior models founded solely on thermal comfort. Changes in activity level and clothing were less likely to be reported when EMAs were triggered by thermostat interactions, while fan interactions were more likely. Windows, shades, and portable heater interactions had no significant dependence on how the EMA was triggered. These results suggest that better understanding of motivations for HBI may improve effectiveness of demand response programs.

Pathak, Maharshi↗