Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

An Overview of the NASA Lift+Cruise eVTOL Crash Test

Introduction – NASA RVLT Project Impact Dynamics / Crash Safety Task - Task Objective: “To improve the crashworthiness and impact safety of Urban Air Mobility (UAM) vehicle and provide data to simplify the certification process. Efforts will include development of validated computational models of these vehicles, as well as other impacting bodies such as birds and drones. Efforts will also focus on developing and evaluating energy absorbing and crush properties of emerging and non-traditional composite materials and processes. Finally, occupant protection will be addressed using computational models and physical assets as it pertains to all rotorcraft environments.” - Problem Statement: “There currently is a lack of data for requirements regarding the crashworthy performance of UAM vehicles and impact loads generated by a bird strike. To address this technology gap, NASA will develop test guidelines, adopt modeling methodologies demonstrating capability for ‘certification by analysis’, acquire vehicle and occupant data on full-scale representative vehicles, and provide data/guidance to consensus standards organizations and the UAM community.” - 4 Main focus points - The investigation of occupant injury using physical and computational assets - The development of energy absorbing technology - The generation of data from sub- and full-scale crash test data - The execution of advanced finite element modelling techniques

evtol↗

Comparison of Anthropomorphic Test Device and human Volunteer Responses in Landing Impact Tests of U.S. Space Vehicles

United States (U.S.) crewed vehicles are being designed to support the National Aeronautics and Space Administration’s (NASA’s) human spaceflight programs. Vehicles must be designed to meet NASA’s occupant protection requirements including landing injury assessment with anthropomorphic test devices (ATDs) and analytical models. However, these tools are limited in capturing all injuries that might occur during spacecraft landings. A NASA study of injuries during Soyuz vehicle landings has shown that analytical models are underpredicting occupant injury. Because of the inherent limitations with our analytical tools, human volunteer impact testing was employed to validate the safety of U.S. crewed vehicles. A total of 84 human volunteer tests in 11 different test orientations and g-levels were completed as part of this effort in collaboration with the Air Force Research Laboratory (AFRL) at Wright-Patterson Air Force Base and the vehicle development companies. Human subjects were tested at various realistic landing loads and in the highest fidelity seat and suit components that were available at the time of testing for two U.S. vehicles. Matched-pair ATD tests in the same test conditions were also conducted with small female and midsized male Hybrid III ATDs. ATDs were fully instrumented. Head accelerations and subjective responses were recorded in human subjects. In some cases, chest accelerations were captured. Responses of the ATDs and humans in matched-pair tests were compared. No ATD tests showed evidence for risk of injury based on NASA occupant protection requirements. Human subjects reported 17 cases of discomfort or pain, 1 human subject was diagnosed with a minor injury that was not evident in the ATD tests. These results provide evidence that ATDs do not capture all potential injury risks, namely lower severity injuries, discomfort, pain, and fit issues. Overall, human testing is beneficial to understanding the true risk of injury to crewmembers during Earth landings.

Teresa Reiber↗

Comparison of Anthropomorphic Test Device and Human Volunteer Responses in Simulated Landing Impact Tests of U.S. Space Vehicles

United States (U.S.) crewed vehicles are being designed to support the National Aeronautics and Space Administration’s (NASA’s) human spaceflight programs. Vehicles must be designed to meet NASA’s occupant protection requirements including landing injury assessment with anthropomorphic test devices (ATDs) and analytical models. However, these tools are limited in capturing all injuries that might occur during spacecraft landings. A NASA study of injuries during Soyuz vehicle landings has shown that analytical models are underpredicting occupant injury. Because of the inherent limitations with our analytical tools, human volunteer impact testing was employed to assess flight-like landing conditions of U.S. crewed vehicles. A total of 84 human volunteer tests in 11 different test orientations and g-levels were completed as part of this effort in collaboration with the Air Force Research Laboratory (AFRL) at Wright-Patterson Air Force Base and U.S. vehicle development companies. Human subjects were tested at various realistic landing loads and in the highest fidelity seat and suit components that were available at the time of testing for two U.S. vehicles. Matched-pair ATD tests in the same test conditions were also conducted with small female and midsized male Hybrid III ATDs. ATDs were fully instrumented. Head accelerations and subjective responses were recorded for human subjects. In some cases, chest accelerations were captured. Responses of the ATDs and humans in matched-pair tests were compared. No ATD tests showed evidence for risk of injury based on NASA occupant protection requirements. Human subjects reported 17 cases of discomfort or pain, and 1 human subject was diagnosed with a minor injury that was not evident in the ATD tests. These results provide evidence that ATDs do not capture all potential injury risks, namely lower severity injuries, discomfort, pain, and fit issues. Overall, human testing is beneficial to understanding the true risk of injury to crewmembers during Earth landings.

Teresa M Reiber↗

Comparison of Anthropomorphic Test Device and Human Volunteer Responses in Simulated Landing Impact Tests of U.S. Space Vehicles

United States (U.S.) crewed vehicles are being designed to support the National Aeronautics and Space Administration’s (NASA’s) human spaceflight programs. Vehicles must be designed to meet NASA’s occupant protection requirements including landing injury assessment with anthropomorphic test devices (ATDs) and analytical models. However, these tools are limited in capturing all injuries that might occur during spacecraft landings. A NASA study of injuries during Soyuz vehicle landings has shown that analytical models are underpredicting occupant injury. Because of the inherent limitations with our analytical tools, human volunteer impact testing was employed to assess flight-like landing conditions of U.S. crewed vehicles. A total of 84 human volunteer tests in 11 different test orientations and g-levels were completed as part of this effort in collaboration with the Air Force Research Laboratory (AFRL) at Wright-Patterson Air Force Base and U.S. vehicle development companies. Human subjects were tested at various realistic landing loads and in the highest fidelity seat and suit components that were available at the time of testing for two U.S. vehicles. Matched-pair ATD tests in the same test conditions were also conducted with small female and midsized male Hybrid III ATDs. ATDs were fully instrumented. Head accelerations and subjective responses were recorded for human subjects. In some cases, chest accelerations were captured. Responses of the ATDs and humans in matched-pair tests were compared. No ATD tests showed evidence for risk of injury based on NASA occupant protection requirements. Human subjects reported 17 cases of discomfort or pain, and 1 human subject was diagnosed with a minor injury that was not evident in the ATD tests. These results provide evidence that ATDs do not capture all potential injury risks, namely lower severity injuries, discomfort, pain, and fit issues. Overall, human testing is beneficial to understanding the true risk of injury to crewmembers during Earth landings.

Teresa M Reiber↗

Comparison of Anthropomorphic Test Device and Human Volunteer Responses in Simulated Landing Impact Tests of U.S. Space Vehicles

United States (U.S.) crewed vehicles are being designed to support the National Aeronautics and Space Administration’s (NASA’s) human spaceflight programs. Vehicles must be designed to meet NASA’s occupant protection requirements including landing injury assessment with anthropomorphic test devices (ATDs) and analytical models. However, these tools are limited in capturing all injuries that might occur during spacecraft landings. A NASA study of injuries during Soyuz vehicle landings has shown that analytical models are underpredicting occupant injury. Because of the inherent limitations with our analytical tools, human volunteer impact testing was employed to assess flight-like landing conditions of U.S. crewed vehicles. A total of 84 human volunteer tests in 11 different test orientations and g-levels were completed as part of this effort in collaboration with the Air Force Research Laboratory (AFRL) at Wright-Patterson Air Force Base and U.S. vehicle development companies. Human subjects were tested at various realistic landing loads and in the highest fidelity seat and suit components that were available at the time of testing for two U.S. vehicles. Matched-pair ATD tests in the same test conditions were also conducted with small female and midsized male Hybrid III ATDs. ATDs were fully instrumented. Head accelerations and subjective responses were recorded for human subjects. In some cases, chest accelerations were captured. Responses of the ATDs and humans in matched-pair tests were compared. No ATD tests showed evidence for risk of injury based on NASA occupant protection requirements. Human subjects reported 17 cases of discomfort or pain, and 1 human subject was diagnosed with a minor injury that was not evident in the ATD tests. These results provide evidence that ATDs do not capture all potential injury risks, namely lower severity injuries, discomfort, pain, and fit issues. Overall, human testing is beneficial to understanding the true risk of injury to crewmembers during Earth landings.

Teresa M Reiber↗

Performance Optimization for Lunar Extravehicular Activity Readiness (POLAR) Study: Methods Paper

To better understand which aspects of physical fitness may be most related to performance during Lunar surface operations and thereby help to inform the current NASA fitness standards, much can be learned from fields encompassing the “tactical athlete.” Other physically demanding professions such as law enforcement, military, or rescue professionals often require candidates to meet occupationally-relevant fitness standards. The determination of such standards is a multistep process, including both objective and subjective measures, to determine tasks essential to occupational performance and identify the minimal fitness profile needed to meet physical demands of the job. Notably, fitness is only one component which may contribute to the demands of astronaut selection, flight assignment, and occupational performance. Utilizing a framework to systematically determine which domains of fitness most contribute to relevant job tasks can aid in the refinement of current NASA-STD-3001 fitness standards. Therefore, NASA’s Exercise Physiology & Countermeasures Laboratory conducted the Performance Optimization for Lunar Extravehicular Activity Readiness (POLAR) study to identify and examine a comprehensive list of fitness tests (including NASA-STD-3001 assessments: 1-Repetition Maximum [1-RM] bench press and deadlift) and determine preliminary relationships between identified fitness parameters and novel Artemis-relevant tasks to help inform future investigations for the continued development of aerobic and muscular fitness standards for surface EVAs. This was accomplished through 1) a review of the literature relating fitness assessments to simulated or real EVA performance to identify fitness tests that are most correlated with simulated EVA task performance; 2) a task analysis following a modified framework for physical employment standards development to down select mission critical tasks; and 3) development and pilot testing of a novel, portable Artemis-relevant EVA task circuit to relate to a battery of fitness assessments. The current report describes the methodology used to complete the task analysis, EVA task circuit development, and the pilot study.

Nicole C Strock↗

Towards Learning-Based Architectures for Sensor Impact Evaluation in Building Controls

Advanced control algorithms for building systems are known to have significant potential in reducing energy consumption while optimizing thermal comfort. The success of such algorithms is critically contingent on several different types of sensor systems, which are in turn, used for continuous monitoring, identification and estimation of several important building states, such as temperatures, humidity, air quality, power consumption and occupancy status. Nonidealities in any of these sensors can lead to significant performance degradation of the control functionalities, and may lead to unwanted sub-optimal building operation. In this paper, we provide a simulation example with a high-fidelity building model, for a particular use-case of advanced optimization-based control in buildings, i.e., occupancy-based controls. We show how imperfections in occupancy sensing can offset performance. Subsequently, we discuss a novel learning-based architecture to efficiently evaluate the impact of sensor nonidealities for building systems, in context of advanced control algorithms.

Bhattacharya, Saptarshi↗

Customer outcomes in Pay-As-You-Save programs

We review the energy and financial outcomes of households participating in several programs based on successive versions of the Pay As You Save¯ (PAYS¯) system. PAYS¯ programs offer non-debt financing for energy efficiency (and sometimes other technologies) in residential buildings through a tariff attached to the home’s utility meter, designed to be offset by project savings. We find that the five programs we study generally serve customers living in zip codes with levels of income and education below the national average and unemployment rates above the national average, demonstrating their potential to improve equity in energy efficiency adoption. Using weather-normalized analysis of energy consumption data, we show that most customers of Midwest Energy’s program reduce annual electricity and gas consumption, averaging 15% and 26% reductions respectively. Changes in energy consumption calculated using this method represent a combination of project effects and changes in occupant behavior. These results are similar to existing analyses of PAYS¯ programs in North Carolina, Arkansas, and Tennessee. About half of participating Midwest households generate sufficient energy cost savings to cover their monthly tariff. Various factors, including changes in occupant behavior, program error, causes independent of the customer or program, or some combination thereof may explain lower-than-expected cost reductions in some projects. Given the inherent variability in annual household electricity consumption, we feel these programs are enabling energy efficiency improvements and their attendant co-benefits, including occupant health and comfort and reduced carbon emissions, while reasonably balancing energy savings and tariff costs. Pairing PAYS¯ with additional financial assistance, as well as promoting cost-effective measures such as air and duct sealing, could further broaden program participation by enabling additional projects to meet PAYS¯ program eligibility rules.

Deason, Jeff↗

Freewheeling: What Six Locations, 61,000 Trips, and 242,000 Miles in Colorado Reveal about How E-Bikes Improve Mobility Options

Personal micromobility modes such as bicycles, e-bikes and scooters offer low- or zero-emission transportation alternatives to single occupancy vehicles (SOVs). However, the lack of supporting data has led to a dearth of data-driven research on the usage of personally owned e-bikes, including variations due to weather, geography and demographics. In this paper, we present an overview of the longitudinal findings from the CanBikeCO program, focused on e-bike adoption and use rates across different demographics, trip characteristics, and geographies. The CanBikeCO program recorded travel survey data from late July 2021 to December 31, 2022, from low-income Colorado households who were provided with e-bikes for personal use by the Colorado Energy Office (CEO). This data was collected in six different communities across Colorado following the mini-pilot program that was conducted in Fall 2020. To collect data for the survey, the program used the NREL OpenPATH application, which combines passive data collection with semantic information such as trip mode and purpose labels. To the best of our knowledge, there is no prior travel survey data on personally owned e-bikes with this range and scope. This unique dataset yielded several insights. One is that commute trips among participants had nearly 17% higher shares of e-bikes than all trips combined. E-bikes were stated to most often replace cars (34% of e-bike trips) and personal micromobility (22%). Participants favored walking for trips less than 1 mile, e-bikes for trips 1-3 miles, and e-bikes, cars or shared rides for trips 3-20 miles. Seasonality accounted for a 10% decrease and subsequent recovery in e-bike mileage on a per user basis. E-bikes are also appealing across age groups, even among older individuals, and see decreased utilization similar to regular bikes or walking during winter months. We also find that e-bike use may be related to characteristics of land use and urban form, occupation and income as well as household car ownership. We conclude that, for this population, who are mainly part of low-income households, the emissions added by the use of e-bikes (in the case of replacement of non-motorized modes) are outweighed by the strong single occupancy vehicle (SOV) travel replacement. As a whole, our findings suggest a considerable potential for energy savings and emissions reductions from personal e-bike ownership.

ADVANCED PROPULSION SYSTEMS↗

An Open-Source Framework for Characterizing Urban Energy Models: Integrating Top-Down and Bottom-Up Methods to Predict Residential Buildings Characteristics: Preprint

Bottom-up urban energy models are crucial for understanding current energy use patterns and informing design strategies. However, accurately characterizing these models to represent different communities remains a challenge due to the extensive data needed for simulating existing energy use behavior. This data includes information related to human activities and building characteristics, all of which correlate with socioeconomic factors. To overcome this challenge, we developed an automated framework that utilizes both top-down and bottom-up data, to predict unknown building and occupant characteristics that are needed for more accurate and equitable modeling and analytics. Our framework, integrated into the URBANopt district energy modeling platform, uses statistical data models from ResStock. URBANopt models co-located buildings and neighborhoods. At this scale there are data gaps in building characteristic data, such as materials, insulation, occupancy, income, and energy usage of the buildings. To address this data gap, we use ResStock data, representative at the census tract scale, and develop machine-learning and deeplearning techniques to disaggregate it to individual buildings. By mapping unique occupant, building and economic properties to URBANopt energy models, we gain detailed insights into the variability of building energy use across different neighborhoods. This insight helps deploy technologies for co-located buildings and supports targeted upgrades for communities with unique economic and demographic characteristics, ensuring energy equity. Accurate characterization of energy models allows us to develop equitable strategies tailored to diverse neighborhoods, whether underserved or affluent. Our automated framework streamlines energy modeling and provides a reliable tool for building energy characterization.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Impact analysis of personalized thermostat demand response

Demand response (DR) aims to curtail peak electric load to avoid running inefficient power plants, reduce costly transmission capacity increases, and improve grid reliability. One method of DR for residential settings involves the utility or third part remotely adjusting thermostat temperatures. Cooling setpoints may be increased 2°F – 6°F for hours, irrespective of occupant comfort. To maintain their comfort, occupants override these setpoint changes impacting the reliability of DR services provided to the grid. This paper presents a preliminary impact analysis of replacing the current DR approach of uniform thermostat setbacks for an entire population with personalized and context aware DR based on a dynamic model of occupant thermal comfort behavior. Over 151k interactions with ecobee thermostats are analyzed to predict the impact of such personalized DR on overrides, energy curtailment magnitude, and reliability.

Kane, Michael↗

Individual Data Sparsity in Smart Thermostat Big Data: Impacts on Modeling Thermostat Use Behavior Dynamics

This study explores the impacts of the sparsity of individual thermostat interaction data on modeling thermostat use behavior dynamics using a dataset of over 100,000 smart thermostats. In developing a data-driven model of Thermal Frustration Theory (TFT), we investigate the challenges and trade-offs in clustering occupant data to enhance predictive accuracy. Our findings reveal that a single, aggregated model fails to capture the diversity of occupant behaviors, resulting in extremely poor prediction performance. Conversely, excessive clustering exacerbates data sparsity, undermining model reliability. By identifying an optimal clustering strategy, we achieve a balance that significantly improves the prediction of manual setpoint changes during demand response (DR) events, enhancing energy management and occupant comfort

Fannon, David↗

Evaluating Thermostats’ Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Thermostats play a crucial role in energy consumption, user control, and occupant comfort by serving as the interface between the heating, ventilation, and air conditioning (HVAC) system and the building's occupants. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on or off. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different thermostats, tested with a residential heat pump, aiming to identify variations in their deadband settings and implications for energy usage and management. The experimental study was conducted using a HVAC hardware-in-the-loop (HIL) system that allows thermostats to be connected with physical HVAC equipment, driven by conditions in a simulated residential building. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats cycle differently based on their deadband settings. The findings offer valuable insights into how thermostat deadband affects comfort and energy use, as well as the cycling frequency of a heat pump.

Ramaraj, Sugirdhalakshmi [National Renewable Energ↗

Mortality of older construction and craft workers employed at Department of Energy (DOE) nuclear sites: Follow‐up through 2021

Background To determine if construction and trades workers formerly employed at US Department of Energy (DOE) nuclear weapons sites are at significant risk for occupational diseases, we studied the mortality experience of participants in the Building Trades National Medical Screening Program (BTMed). Methods The cohort included 26,922 participants enrolled between 1998 and 2021 and 8367 deaths. Standardized mortality ratios were calculated based on US death rates. Cox models compared construction workers (n = 22,747; 7487 deaths) to two nonconstruction subpopulations: administrative, scientific and security workers (n = 1894; 330 deaths), and all other nonconstruction workers (n = 2218; 550 deaths). Results Mortality was elevated for all causes, all cancers, cancers of the trachea, bronchus, lung, kidneys, and lymphatic and hematopoietic system, mesothelioma, chronic obstructive pulmonary disease (COPD), asbestosis, transportation injuries, and other injuries, particularly accidental poisonings. There were 167 deaths from coronavirus disease 2019 (COVID-19), which was lower than expected using US death rates. Overall cause-specific mortality was significantly higher among construction workers than for internal comparison groups. Conclusions Construction workers employed at DOE sites have a significantly increased risk for occupational illnesses. Apart from COVID-19 deaths, this update: (1) found that mortality among construction workers is significantly elevated compared to the US population and significantly higher than in the internal comparison populations, and (2) confirmed excess risk for these workers for first employment after 1990. Cancer mortality risks are similar to the cancers identified for DOE compensation from radiation exposures. In conclusion, the high lung cancer risk supports the value of early lung cancer detection. Continued medical surveillance is important.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Respirator Cartridge Performance on Mixed Vapors from Hanford Tank Headspaces and Exhausters - 20427

Between 2016 and 2018, the Hanford Tank Operations Contractor - Washington River Protection Solutions (WRPS) - conducted a series of tests of air-purifying respirator (APR) chemical cartridges commonly used at Hanford tank farms to determine the period of time for which the cartridges would provide adequate performance when used in APRs and powered-air-purifying respirators (PAPRs) to protect workers when exposed to a mixture of vapors exiting tank headspaces. Although cartridge manufacturers provide service life estimating tools for individual chemical compounds, the projected performance of these cartridges on complex vapor mixtures is not available, and the adequacy of APRs for tank farm applications represents an important workforce concern. The Occupational Safety and Health Administration identifies cartridge testing as a valid approach for establishing cartridge service life. The primary function of the WRPS Cartridge Test Program was to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford tank farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis of and recommendations based on respirator cartridge performance. A total of 28 APR and 10 PAPR cartridge tests were conducted between 2016 and 2018 on 12 different tank headspaces and tank farm exhauster slipstreams. Two APR cartridges from SCOTT (now 3M) and two PAPR cartridges from MSA Safety, Inc. and 3M were evaluated using a cartridge testing system specifically designed to measure and monitor test conditions and sample cartridge inlet and outlet vapor streams for important chemical compounds. Testing focused on analysis of approximately 61 tank vapor chemicals of potential concern (COPCs) that have been previously detected in tank vapors at levels above 10% of their occupational exposure limits (OELs). Each test was conducted over 16 hours of run time. Evidence of chemical breakthrough was assessed by comparing inlet and outlet COPC concentrations over the duration of each test. The breakthrough threshold was normally defined as exceeding 10% of the compounds OEL at the cartridge outlet. Ammonia breakthrough was observed in a majority of the cartridge tests and occurred earlier than breakthrough of any other chemical compound. Several other COPCs did exhibit breakthrough behavior, including mercury, 1,3-butadiene, furan, 2,5 dihydrofuran, and N-nitrosodimethylamine (NDMA), but only in a very limited number of cartridge tests and only after ammonia breakthrough had occurred. In addition, tests results suggest that breakthrough of some of these COPCs may have been affected by competition with and breakthrough of other non-COPC organics, such as ethanol and acetone, with substantially lower toxicological hazard. Comparison of cartridge manufacturers' service life estimates with the experimentally derived breakthrough times indicates that manufacturers' estimates are generally conservative, even in the presence of the complex mixed vapor streams experienced in these tests. With consideration of appropriate safety margins, these results provide valuable insights on cartridge performance to inform industrial hygiene professionals in establishing appropriate cartridge change-out schedules for APR and PAPR use in the Hanford tank farms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗