Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPTICS DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Lessons Learned in Designing A Proposed Ultraviolet Sterilization System for Space

This paper presents a number of lessons learned while designing a proposed sterilization system for Mars Sample Return. This sterilization system is needed to inactivate any potentially hazardous Mars material on the exterior surface of the vessel containing sealed sample tubes filled with Mars rock cores, regolith and atmosphere. These returned samples would provide information on the geologic history of Mars, the evolution of its climate and the potential for ancient life. Mars Sample Return is categorized at Planetary Protection Category V Restricted Earth Return, so it is required to protect the Earth–Moon system from the biological impact of returning samples from Mars to Earth. This article reviews lessons learned in the development of a particular engineering implementation to support the protection of the Earth–Moon biosphere: the use of in situ ultraviolet LED illumination. The details of the biological efficacy of this approach or the policy-related impacts are outside of the scope of this manuscript. The lessons learned presented here include establishing design requirements for the system, the selection of a light source, optical design options, contamination control and approaches to thermal and power management.

Planetary Protection↗

Update on the MEIC electron collider ring design

The electron collider ring of the Medium-energy Electron-Ion Collider (MEIC) at Jefferson Lab is designed to accumulate and store a high-current polarized electron beam for collisions with an ion beam. We consider a design of the electron collider ring based on reusing PEPII components, such as magnets, power supplies, vacuum system, etc. This has the potential to significantly reduce the cost and engineering effort needed to bring the project to fruition. This paper reports on an electron ring optics design considering the balance of PEP-II hardware parameters (such as dipole sagitta, magnet field strengths and acceptable synchrotron radiation power) and electron beam quality in terms of equilibrium emittances.

43 PARTICLE ACCELERATORS↗

Design of multilayer-based diagnostics for measurement of high energy x rays and gamma rays

We investigate several possible multilayer-based optic designs for future hard x-ray and gamma ray diagnostics, including the detection and measurement of the positron annihilation radiation at 511 keV. The focus is set on increasing the photon efficiency and signal-to-noise ratio, compared to a previous multilayer-based system that was successfully employed to measure spectra in the 55 keV–100 keV range. Several possible designs using multilayer coatings are discussed, including mirror-based optics and multilayer Laue lenses.

Burcklen, C. (ORCID:0000000271566357)↗

Single-Layer Plasmonic Metasurface Half-Wave Plates with Wavelength-Independent Polarization Conversion Angle

Manipulation of polarization state is of great fundamental importance and plays a crucial role in modern photonic applications such as optical communication, imaging, and sensing. Metamaterials and metasurfaces have attracted increasing interest in this area because they facilitate designer optical response through engineering the composite subwavelength structures. In this paper, we propose a general methods of designing half-wave plate and demonstrate in the near-infrared wavelength range an optically thin plasmonic metasurface half-wave plates that rotate the polarization direction of the linearly polarized incident light with a high degree of linear polarization. Finally, the half-wave plate functionality is realized through arranging the orientation of the nanoantennas to form an appropriate spatial distribution profile, which behave exactly as in classical half-wave plates but over in a wavelength-independent way.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Review of the FOCSI (Fiber Optic Control System Integration) program

A joint NASA/NAVY program, called FOCSI, is reviewed which is aimed at designing optical sensor systems to fit the installation and environmentally test passive optical sensors and electrooptic architectures. These optical sensor systems will be flown on an F18 aircraft to collect data on the operability and maintainability of these systems in a flight environment. The NASA F-18 aircraft will be equipped with a 1773 optical databus to transfer the optical sensor information to the aircraft data collection location.

Baumbick, Robert↗

Fabrication of monocrystalline silicon x-ray mirrors

Progress within the fi eld of x-ray astronomy depends on astronomical x-ray observations of ever-increasing quality and speed. Fast and high-resolution x-ray observations over a broad spectral range promise amazing new discoveries. These observations, however, require a spaceborne x-ray telescope of unprecedented imaging power. Of the numerous technological concerns associated with the design and construction of such a telescope, the x-ray focusing optics present a particularly complex and arduous set of challenges. An x-ray optical assembly comprises many thousands of x-ray mirrors, a most critical element. Our group at NASA Goddard Space Flight Center (GSFC) pursues the development of an x-ray mirror manufacturing process capable of meeting the stringent quality, production time, and cost requirements of the next-generation of x-ray telescopes. The manufacturing process employs monocrystalline silicon: a lightweight, stiff, thermally conductive, and readily available material which is free of internal stress; it is a nearly ideal material for a thin mirror substrate. The process involves various traditional optical fabrication techniques adapted to x-ray mirror geometry. Presently, our process is capable of fabricating sub-arcsecond half-power diameter (HPD) resolution mirror pairs (primary and secondary) at a mirror thickness of 0.5 mm and of virtually any x-ray optical design (e.g. Wolter-I, Wolter-Schwarzschild, etc.). The mirror substrate surface quality is comparable to, and sometimes exceeding, that of the mirrors on the Chandra X-ray Observatory. This paper describes the various manufacturing steps involved in the production of x-ray mirror substrates and a present status report.

Raul E. Riveros↗

A Flight Simulator for ATF2 - A Mechanism for International Collaboration in the Writing and Deployment of Online Beam Dynamics Algorithms

The goals of ATF2 are to test a novel compact final focus optics design with local chromaticity correction intended for use in future linear colliders. The newly designed extraction line and final focus system will be used to produce a 37nm vertical waist from an extracted beam from the ATF ring of {approx}30nm vertical normalized emittance, and to stabilize it at the IP-waist to the {approx}2nm level. Static and dynamic tolerances on all accelerator components are very tight; the achievement of the ATF2 goals is reliant on the application of multiple high-level beam dynamics control algorithms to align and tune the electron beam in the extraction line and final focus system. Much algorithmic development work has been done in Japan and by colleagues in collaborating nations in North America and Europe. We describe here development work towards realizing a 'flight simulator' environment for the shared development and implementation of beam dynamics code. This software exists as a 'middle-layer' between the lower-level control systems (EPICS and V-SYSTEM) and the multiple higher-level beam dynamics modeling tools in use by the three regions (SAD, Lucretia, PLACET, MAD...).

43 PARTICLE ACCELERATORS↗

Experience with split transition lattices at RHIC

During the acceleration process, heavy ion beams in RHIC cross the transition energy. When RHIC was colliding deuterons and gold ions during Run-8, lattices with different integer tunes were used for the two rings. This resulted in the two rings crossing transition at different times, which proved beneficial for the 'Yellow' ring, the RF system of which is slaved to the 'Blue' ring. For the symmetric gold-gold run in FY2010, lattices with different transition energies but equal tunes were implemented. We report the optics design concept as well as operational experience with this configuration.

43 PARTICLE ACCELERATORS↗

Demonstration of spectral calibration for stellar interferometry

A breadboard is under development to demonstrate the calibration of spectral errors in microarcsecond stellar interferometers. Analysis shows that thermally and mechanically stable hardware in addition to careful optical design can reduce the wavelength dependent error to tens of nanometers. Calibration of the hardware can further reduce the error to the level of picometers. The results of thermal, mechanical and optical analysis supporting the breadboard design will be shown.

spectral calibration↗

Methods for Prediction of Refractive Index in Glasses for the Infrared

It is often useful to obtain custom glasses that meet particular requirements of refractive index and dispersion for high-end optical design and applications. In the case of infrared glasses, limited experimental data are available due to difficulties in processing of these glasses and also measuring refractive indices accurately. This paper proposes methods to estimate refractive index and dispersion as a function of composition for selected infrared-transmitting glasses. Methods for refractive index determination are reviewed and evaluated, including Gladstone-Dale, Wemple-DiDomenico single oscillator, Optical basicity, and Lorentz-Lorenz total polarizability. Various estimates for a set of PbO-Bi2O3-Ga2O3 (heavy metal oxide) and As-S (chalcogenide) glasses will be compared with measured values of index and dispersion.

36 MATERIALS SCIENCE↗

A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of vortex flow fields

A 3-D laser fluorescence anemometer (LFA) was designed, built, and demonstrated for use in the Langley 16 x 24 inch Water Tunnel. Innovative optical design flexibility combined with compact and portable data acquisition and control systems were incorporated into the instrument. This will allow its use by NASA in other test facilities. A versatile fiber optic system facilities normal and off-axis laser beam alignment, removes mirror losses and improves laser safety. This added optical flexibility will also enable simple adaptation for use in the adjacent jet facility. New proprietary concepts in transmitting color separation, light collection, and novel prism separation of the scattered light was also designed and built into the system. Off-axis beam traverse and alignment complexity led to the requirement for a specialized, programmable transverse controller, and the inclusion of an additional traverse for the off-axis arm. To meet this challenge, an 'in-house' prototype unit was designed and built and traverse control software developed specifically for the water tunnel traverse applications. A specialized data acquisition interface was also required. This was designed and built for the LFA system.

Mcdevitt, T. Kevin↗

Theoretical simulation of a 2 micron airborne solid state laser anemometer

In the near future, military aircraft will need to know precisely their true airspeed in order to optimize flight conditions. In comparison with classical anemometer probes, an airborne Doppler lidar allows measurement of the air velocity without influence from aircraft aerodynamic disturbance. While several demonstration systems of heterodyne detection using a CO2 laser have been reported, improvements in the technology of solid state lasers have recently opened up the possibility that these devices can be used as an alternative to CO2 laser systems. In particular, a diode pumped Tm:Ho:YAG laser allows a reliable compact airborne system with an eye safe wavelength (lambda = 2.09 microns) to be achieved. The theoretical study of performances of a coherent lidar using a solid state diode pumped Tm:Ho:YAG laser, caled SALSA, for measuring aircraft airspeed relative to atmospheric aerosols is described. A computer simulation was developed in order to modelize the Doppler anemometer in the function of atmospheric propagation and optical design. A clever analysis of the power budget on the detector area allows optical characteristic parameters of the system to be calculated, and then it can be used to predict performances of the Doppler system. Estimating signal to noise ratios (SNR) and heterodyne efficiency provides the available energy of speed measurement as well as a useful measurement of the alignment of the backscattered and reference fields on the detector.

Imbert, Beatrice↗

Contamination Effects on EUV Optics

During ground-based assembly and upon exposure to the space environment, optical surfaces accumulate both particles and molecular condensibles, inevitably resulting in degradation of optical instrument performance. Currently, this performance degradation (and the resulting end-of-life instrument performance) cannot be predicted with sufficient accuracy using existing software tools. Optical design codes exist to calculate instrument performance, but these codes generally assume uncontaminated optical surfaces. Contamination models exist which predict approximate end-of-life contamination levels, but the optical effects of these contamination levels can not be quantified without detailed information about the optical constants and scattering properties of the contaminant. The problem is particularly pronounced in the extreme ultraviolet (EUV, 300-1,200 A) and far (FUV, 1,200-2,000 A) regimes due to a lack of data and a lack of knowledge of the detailed physical and chemical processes involved. Yet it is in precisely these wavelength regimes that accurate predictions are most important, because EUV/FUV instruments are extremely sensitive to contamination.

Tveekrem, J.↗

Cryogenic refractor design techniques

The Infrared Astronomical Satellite (IRAS) was designed to operate at 2K, and over the spectral range of 8 to 120 micrometers. The focal plane is approximately 2 by 3 inches in size, and contains 62 individual field stop apertures, each with its own field lens, one or more filters and a detector. The design of the lenses involved a number of difficulties and challenges that are not usually encountered in optical design. Operating temperature is assumed during the design phase, which requires reliable information on dN/dT (Index Coefficient) for the materials. The optics and all supporting structures are then expanded to room temperature, which requires expansion coefficient data on the various materials, and meticulous attention to detail. The small size and dense packaging, as well as the high precision required, further contributed to the magnitude of the task.

Darnell, R. J.↗