Annulus Monitoring of CO2 Injection Using Wireless Autonomous Distributed Sensor Networks.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
The network control center (NCC) provides scheduling, monitoring, and control of services to the NASA space network. The space network provides tracking and data acquisition services to many low-earth orbiting spacecraft. This report describes the second phase in the development of simulation models for the FCC. Phase one concentrated on the computer systems and interconnecting network.Phase two focuses on the implementation of the network message dialogs and the resources controlled by the NCC. Performance measures were developed along with selected indicators of the NCC's operational effectiveness.The NCC performance indicators were defined in terms of the following: (1) transfer rate, (2) network delay, (3) channel establishment time, (4) line turn around time, (5) availability, (6) reliability, (7) accuracy, (8) maintainability, and (9) security. An NCC internal and external message manual is appended to this report.
!.
The GPS satellites and a world-wide network of dual-frequency GPS receivers allow one to.
The results of a preliminary study to access the accuracy of global ionospheric maps are presented. Global ionospheric maps, produced using dual-frequency data from the global network of GPS receivers, are.
Explore the source record for details and available documents.
There are a number of reasons why it is important to increase the density of data acquisition functions. Sensor fusion seeks to integrate large numbers of sensors into a decision network. Addition of health monitoring functions may incur additional sensor requirements. But at the same time, it is important to reduce the per-channel costs of data acquisition systems. Often the most significant cost is the management of data acquisition networks, which incurs substantial costs associated with transducer installation, configuration, calibration, and maintenance. Alternatives that lower the cost of the transducer system and reduce the data acquisition system channel count will directly impact initial system costs. Other techniques that affect maintenance and operating costs will contribute to reducing life cycle costs. This paper describes work undertaken to explore alternative architectures for lowering the cost per transducer function using a MEMS-based accelerometer as the model.
The Gulf Coast region possesses great potential for CO 2 enhanced oil recovery (EOR) and CO 2 storage. A geochemically informed leak detection (GILD) model has been applied to CO 2 injection sites on the Gulf Coast with considerations of measurement variability. The Jasper aquifer in Montgomery County, Texas, was chosen to demonstrate the method. Based on background data from wells in the area, combinations of mineral and fluid compositions were used to create 23 scenarios for the geochemical model. The output from the geochemical model was used to identify sensitive monitoring species, and response functions were generated for these as a function of the CO 2 leakage concentration. The sources of measurement variability for background conditions were characterized from the Jasper aquifer background data, and then normalized using the coefficient of variation of each species across the monitoring wells. Bayesian belief network (BBN) models were constructed, and measurement variability of different levels were added to compare leak detection probabilities. Increasing measurement variability decreased the power to detect a leak of a given size. For a moderately high CO 2 concentration of 0.2 mol/kg, the probability of detecting this leakage effect using pH as the monitoring variable in an aquifer with calcite decreases from 98% (no measurement variability) to 61% (medium variability) to 33% (high variability). The loss in power of the sampling protocol with increasing measurement variability is similar in magnitude when Ca 2+ or HCO 3 - is used as the monitoring parameter, but only for aquifers with calcite.
Abstract The energy sector is expected to undergo significant changes in the coming decades with the advent of new technologies, including smart grid development, microgrid expansion, increasing electric vehicle and renewable energy usage, and enhanced measures to minimize greenhouse gas emission, among others. In tandem, these changes are expected to create new opportunities for the deployment of quantum technologies within the energy sector. Building on the authors' previous reviews on the current state of and future opportunities for quantum sensing, quantum computing and quantum simulations for energy sector applications, this work provides an overview of recent progress in quantum networking and communications for the energy industry, with a focus on platforms, devices, and protocols, including quantum teleportation and quantum key distribution. Specific areas of relevance to the energy sector are then analyzed, including the role of quantum networks for greenhouse gas monitoring, secure data collection and transmission in smart grids, nuclear power plants’ safety, facilitating oil and gas exploration, and other energy‐relevant applications. This review concludes with a brief overview of areas for future innovation, including the need for platforms for simulating quantum networks, quantum material and platform design, and computational approaches to accelerate quantum protocol discovery and development.
Earthquake phase association algorithms aggregate picked seismic phases from a network of seismometers into individual seismic events and play an important role in earthquake monitoring and research. Dense seismic networks and improved phase picking methods produce massive seismic phase datasets, particularly for earthquake swarms and aftershocks occurring closely in time and space, making phase association a challenging problem. Here, we present a new association method, the Gaussian Mixture Model Association (GaMMA), that combines the Gaussian mixture model with earthquake location, origin time, and magnitude estimation. We treat earthquake phase association as an unsupervised clustering problem in a probabilistic framework, where each earthquake corresponds to a cluster of P and S phases with a hyperbolic moveout of arrival times and a decay of amplitude with distance. We use the multivariate Gaussian distribution to model the collection of phase picks of an event; and the mean of the multivariate Gaussian distribution is given by the predicted arrival time and amplitude from the causative event. We carry out the pick assignment to each earthquake and determine earthquake source parameters (i.e., earthquake location, origin time, and magnitude) under the maximum likelihood criterion using the Expectation-Maximization algorithm. The GaMMA method does not require typical association steps of other algorithms, such as grid-search or supervised training. The results for both synthetic tests and for the 2019 Ridgecrest earthquake sequence show that GaMMA effectively associates phases from a temporally and spatially dense earthquake sequence while producing useful estimates of earthquake location and magnitude.
This document presents a plan for testing and characterizing the hydraulic properties of the Ringold Formation, member of Wooded Island – unit A (Rwia) in the 200-ZP groundwater operable unit. The testing approach includes multiple field methods and associated analyses designed to investigate and understand aquifer hydraulic properties over a range of scales. Testing was designed to achieve specific testing objectives identified previously in the 200 ZP-1 Groundwater Operable Unit Ringold Formation Unit A Characterization Sampling and Analysis Plan (Ringold A SAP). The test plan provides necessary technical and operational detail for writing subsequent field test instruction documents specific to each testing location. Hydraulic characterization activities will proceed in a phased manner focusing on areas identified to have knowledge gaps and also critical for remedy modifications and/or selection. These activities are designed to minimize impact to pump-and-treat (P&T) operations and to use existing P&T injection and extraction wells as stress wells, and include use of the new Rwia monitoring wells installed for Ringold A SAP activities. ZP-1 hydraulic testing will include slug testing in new Rwia wells, shutdown-recovery tests in multiple Rwia and composite Ringold Formation member of Wooded Island – unit E (Rwie)-Rwia aquifer test locations, installation of new Automated Water Level Network stations in Rwia monitoring wells, characterization of P&T and barometric responses, identifying the vertical distribution of hydraulic conductivity in the Rwia and Rwie units using electromagnetic borehole flowmeter tests, and single-well tracer testing in select Rwia monitoring wells. Slug testing to be conducted during drilling is described under the Ringold A SAP. The remaining testing activities are to be conducted after well drilling and completion and are described in this test plan.
INTRODUCTION: In the aging brain, cognitive abilities emerge from the coordination of complex pathways arising from a balance between protective lifestyle and environmental factors and accumulation of neuropathologies. METHODS: As part of the Rush Memory and Aging Project (n = 440), we measured accelerometer-based actigraphy, cognitive performance, and after brain autopsy, selected reaction monitoring mass spectrometry. Multilevel network analysis was used to examine the relationships among the molecular machinery of vesicular neurotransmission, Alzheimer's disease (AD) neuropathology, cognition, and late-life physical activity. RESULTS: Synaptic peptides involved in neuronal secretory function were the most influential contributors to the multilayer network, reflecting the complex interdependencies among AD pathology, synaptic processes, and late-life cognition. Older adults with lower physical activity evidenced stronger adverse relationships among phosphorylated tau peptides, markers of synaptic integrity, and tangle pathology. DISCUSSION: Network-based approaches simultaneously model interdependent biological processes and advance understanding of the role of physical activity in age-associated cognitive impairment. Highlights: Network-based approaches simultaneously model interdependent biological processes. Secretory synaptic peptides were influential contributors to the multilayer network. Older adults with lower physical activity had adverse relationships among pathology. There was interdependence among phosphorylated tau, synaptic integrity, and tangles. Network methods elucidate the role of physical activity in cognitive impairment.
Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.
Implementing a zero trust architecture can significantly bolster the security of electric vehicle (EV) charging infrastructure. EV charging infrastructure includes numerous networked interfaces, each of which can present potential vulnerabilities. When these vulnerabilities are exploited, they can compromise the entire system, leading to severe operational and security risks. Zero trust is a security model that operates on the principle of "never trust, always verify," which helps manage the attack surface and limit the scope of any potential compromises. Fundamentally, this model ensures that no entity, whether inside or outside the network, is trusted by default. The design principles of zero trust include continuous verification, strict deny-by-default access controls, and micro-segmentation. Continuous verification ensures that every request is thoroughly checked, regardless of its origin. Strict access controls enforce the principle of least privilege, allowing users and devices only the minimum necessary access to perform their functions. Micro-segmentation involves dividing the network into smaller, isolated segments to prevent lateral movement in case of a breach. In the context of EV charging infrastructure, zero trust can be implemented through various strategies. For example, multi-factor authentication (MFA) can be required for engineers to access the management interfaces and control systems of charging stations. Real-time monitoring and analysis of network traffic can help detect and respond to anomalies. Systems that do not need to communicate with each other can be micro-segmented to enhance security. All communications should adhere to predefined policies to be permitted. Additionally, encrypting communications can protect sensitive information exchanged between chargers and management systems. This paper presents a zero trust architecture specifically designed for EV charging infrastructure. Implementing zero trust not only mitigates risks but also builds a resilient infrastructure capable of withstanding and quickly recovering from cyber threats. The architecture addresses six defined security objectives. A comprehensive test plan is developed to assess the architecture against these objectives, and the results of the evaluation are reported. This approach is essential for maintaining the reliability and integrity of EV charging services in an increasingly interconnected and vulnerable digital landscape. This is the first in a planned series of papers exploring the implementation of zero trust in EV charging infrastructure. Each paper will delve into different aspects and applications of zero trust, highlighting how various work processes and requirements can lead to distinct architectural designs. These architectures will be tailored to address specific security challenges and operational needs within the EV charging ecosystem, ensuring a robust and adaptable security framework.
Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.
The authors describe the Ada language software developed to perform the electrical power system monitoring functions for the NASA Lewis Research Center's Power Management and Distribution (PMAD) DC testbed. The results of the effort to implement this monitor are presented. The PMAD DC testbed is a reduced-scale prototype of the electric power system to be used in Space Station Freedom. The power is controlled by smart switches known as power control components (or switchgear). The power control components are currently coordinated by five Compaq 386/20e computers connected through an 802.4 local area network. The power system monitor algorithm comprises several functions, including periodic data acquisition, data smoothing, system performance analysis, and status reporting. Data are collected from the switchgear sensors every 100 ms, then passed through a 2-Hz digital filter. System performance analysis includes power interruption and overcurrent detection. The system monitor required a hardware timer interrupt to activate the data acquisition function. The execution time of the code was optimized by using an assembly language routine. The routine allows direct vectoring of the processor to Ada language procedures that perform periodic control activities.
The general aim of this work is to develop and demonstrate a prototype structural health monitoring system for thermal protection systems that incorporates piezoelectric acoustic emission (AE) sensors to detect the occurrence and location of damaging impacts, such as those from Micrometeoroid Orbital Debris (MMOD). The approach uses an optical fiber Bragg grating (FBG) sensor network to evaluate the effect of detected damage on the thermal conductivity of the TPS material. Following detection of an impact, the TPS would be exposed to a heat source, possibly the sun, and the temperature distribution on the inner surface in the vicinity of the impact measured by the FBG network. A similar procedure could also be carried out as a screening test immediately prior to re-entry. The implications of any detected anomalies in the measured temperature distribution will be evaluated for their significance in relation to the performance of the TPS during reentry. Such a robust TPS health monitoring system would ensure overall crew safety throughout the mission, especially during reentry.