Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Reduction of PMT Signal-Induced Noise in Lidar Receivers

Signal-induced noise is generated when a photomultiplier tube (PMT) is subjected to an intense light pulse. The PMT signal does not return to the dark current level after the signal is removed, but decays slowly (i.e., signal-induced noise). This is of practical significance for DIAL (Differential Absorption lidar) measurements where signal-induced noise decays are superimposed on the on-line (absorption) and off-line signals. Errors in the ozone density calculation result for stratosphere measurements. Other researchers have implemented mechanical choppers that block the intense pulse which may be from near field return scattering or scattering from a cloud. This configuration cannot be implemented for the DIAL system employed for aircraft measurements since the on-line and off-line pulses are 300 microseconds apart. A scheme has been developed in this study to electronically attenuate the signal induced noise. A ring electrode, external to the PMT photocathode, is utilized to perturb the electron trajectories between the photocathode and the first dynode. This effect has been used for position sensitive PMTs and suggested for gating PMTS.

Williamson, Cynthia K.↗

Multi-Dimensional Spectroscopy with Intense Entangled Beams: Entanglement-Enabled Phase Matching in a Collinear Beam Geometry

The experimental realization of quantum molecular spectroscopy with entangled photons remains challenging owing to the low signal-to-noise ratio resulting from the use of low-flux entangled photons. High-flux entangled photons via intense entangled beams can be used to improve the signal-to-noise ratio, but the presence of unentangled photons contaminates the quantum signal stemming from entangled photons. Here, we demonstrate how intense entangled beams can be used in multi-dimensional spectroscopy while retaining the advantage of photon entanglement. Our approach is broadly applicable to odd-ordered nonlinear spectroscopies, and it generates purely quantum spectroscopic signals. The proposed approach allows the recording of desired phase-matched signals even in a collinear beam geometry, which lifts the requirement of complicated beam geometry setups for phase matching in multi-dimensional spectroscopies.

Absorption spectroscopy↗

Two-color continuous-variable quantum entanglement in a singly resonant optical parametric oscillator

We apply the input-output theory of optical cavities to formulate a quantum treatment of a continuous-wave singly resonant optical parametric oscillator. This case is mainly relevant to highly nondegenerate signal and idler modes. We show that both intensity and quadrature squeezing are present and that the maximum noise reduction below the standard quantum limit is the same at the signal and idler frequencies as in the doubly resonant case. As the threshold of oscillation is approached, however, the intensity-difference and quadrature spectra display a progressive line narrowing which is absent in the balanced doubly resonant case. By use of the separability criterion for continuous variables, the signal-idler state is found to be entangled over wide ranges of the parameters. We show that attainable levels of squeezing and entanglement make singly resonant configurations ideal candidates for two-color quantum information processes, because of their ease of tuning in experimental realizations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma waves in the distant magnetotail

The results of an extensive study of plasma waves in the distant magnetotail on the basis of measurements from the Imp 8 spacecraft are discussed. The plasma measurements are compared with plasma and magnetic field measurements described by Frank et al. (1976) to study the relationship of the plasma waves to the various plasma regimes found in the distant magnetotail. Three distinctly different types of plasma wave turbulence in the distant magnetotail are detected. The first, most frequently occurring type of turbulence, consists of broadband electrostatic noise at frequencies between 10 Hz and a few kHz. The second, less frequent type of plasma wave turbulence consists of intense (100 milligamma) bursts of low frequency (10 to 300 Hz) magnetic noise. The third, least frequent type of turbulence consists of electrostatic waves near harmonics of the electron gyrofrequency.

Gurnett, D. A.↗

Improving Signal to Noise Ratios in Ion Mobility Spectrometry and Structures for Lossless Ion Manipulations (SLIM) using a High Dynamic Range Analog-to-Digital Converter

Signal digitization is a commonly overlooked part of ion mobility-mass spectrometry (IMS-MS) workflows, yet it is a significant contributor for determining signal-to-noise ratios and MS resolution. Here we report on the integration of a 2 GS/s, 14-bit ADC with a structures for lossless ion manipulations (SLIM)-IMS-MS and compare the performance to a commonly used 8-bit ADC. The 14-bit ADC provided an effective reduction in digitized noise by factor of ~6, owing largely to the use of smaller bit sizes. The low baseline allowed the threshold voltage levels to be set very close to the MCP baseline voltage, allowing for as much signal to be acquired as possible without causing overloading or excessive digitization of MCP baseline noise. Analyses of Agilent tuning mixture ions and a complex mixture of heavy labeled phosphopeptides showed that the 14-bit ADC (compared to the 8-bit ADC) provided a modest signal-to-noise increase (~1.5 to 2-fold) for high intensity ions, such as the Agilent tuning mixture ions and the 2+ and 3+ charge states of many phosphopeptide constituents. However, signal enhancements were as much as 10-fold for low intensity ions, and the 14-bit ADC enabled discernable signal intensities otherwise lost using an 8-bit digitizer. Additionally, the 14-bit ADC required ~14-fold fewer mass spectra to be averaged to produce a mass spectrum with similar S/N as the 8-bit ADC under identical conditions, potentially providing an order of magnitude higher measurement throughput. The high resolution, low baseline, and fast speed of the new 14-bit ADC enables high performance digitization of MS, IMS-MS, and SLIM-IMS-MS spectra, and allows a much fuller picture of analyte profiles in complex mixtures to be acquired.

data acquisition, digitization, ion mobility spect↗

Improvements in High Speed, High Resolution Dynamic Digital Image Correlation for Experimental Evaluation of Composite Drive System Components

Composite materials have the potential to reduce the weight of rotating drive system components. However, these components are more complex to design and evaluate than static structural components in part because of limited ability to acquire deformation and failure initiation data during dynamic tests. Digital image correlation (DIC) methods have been developed to provide precise measurements of deformation and failure initiation for material test coupons and for structures under quasi-static loading. Attempts to use the same methods for rotating components (presented at the AHS International 68th Annual Forum in 2012) are limited by high speed camera resolution, image blur, and heating of the structure by high intensity lighting. Several improvements have been made to the system resulting in higher spatial resolution, decreased image noise, and elimination of heating effects. These improvements include the use of a high intensity synchronous microsecond pulsed LED lighting system, different lenses, and changes in camera configuration. With these improvements, deformation measurements can be made during rotating component tests with resolution comparable to that which can be achieved in static tests

high speed imaging↗

Improvements in High Speed, High Resolution Dynamic Digital Image Correlation for Experimental Evaluation of Composite Drive System Components

Composite materials have the potential to reduce the weight of rotating drive system components. However, these components are more complex to design and evaluate than static structural components in part because of limited ability to acquire deformation and failure initiation data during dynamic tests. Digital image correlation (DIC) methods have been developed to provide precise measurements of deformation and failure initiation for material test coupons and for structures under quasi-static loading. Attempts to use the same methods for rotating components (presented at the AHS International 68th Annual Forum in 2012) are limited by high speed camera resolution, image blur, and heating of the structure by high intensity lighting. Several improvements have been made to the system resulting in higher spatial resolution, decreased image noise, and elimination of heating effects. These improvements include the use of a high intensity synchronous microsecond pulsed LED lighting system, different lenses, and changes in camera configuration. With these improvements, deformation measurements can be made during rotating component tests with resolution comparable to that which can be achieved in static tests.

composite materials↗

Improvements in High Speed, High Resolution Dynamic Digital Image Correlation for Experimental Evaluation of Composite Drive System Components

Composite materials have the potential to reduce the weight of rotating drive system components. However, these components are more complex to design and evaluate than static structural components in part because of limited ability to acquire deformation and failure initiation data during dynamic tests. Digital image correlation (DIC) methods have been developed to provide precise measurements of deformation and failure initiation for material test coupons and for structures under quasi-static loading. Attempts to use the same methods for rotating components (presented at the AHS International 68th Annual Forum in 2012) are limited by high speed camera resolution, image blur, and heating of the structure by high intensity lighting. Several improvements have been made to the system resulting in higher spatial resolution, decreased image noise, and elimination of heating effects. These improvements include the use of a high intensity synchronous microsecond pulsed LED lighting system, different lenses, and changes in camera configuration. With these improvements, deformation measurements can be made during rotating component tests with resolution comparable to that which can be achieved in static tests.

Kohlman, Lee↗

An in-vacuum x-ray diffraction microscope for use in the 0.7-2.9 keV range

A dedicated in-vacuum coherent x-ray diffraction microscope was installed at the 2-ID-B beamline of the Advanced Photon Source for use with 0.7-2.9 keV x-rays. The instrument can accommodate three common implementations of diffractive imaging; plane wave illumination; defocused-probe (Fresnel diffractive imaging) and scanning (ptychography) using either a pinhole, focused or defocused probe. The microscope design includes active feedback to limit motion of the optics with respect to the sample. Upper bounds on the relative optics-to-sample displacement have been measured to be 5.8 nm(v) and 4.4 nm(h) rms/h using capacitance micrometry and 27 nm/h using x-ray point projection imaging. The stability of the measurement platform and in-vacuum operation allows for long exposure times, high signal-to-noise and large dynamic range two-dimensional intensity measurements to be acquired. Finally, we illustrate the microscope's stability with a recent experimental result.

43 PARTICLE ACCELERATORS↗

Generalized Subtraction Schemes for the Difference Formulation in Radiation Transport

In the difference formulation for the transport of thermally emitted photons, the photon intensity is defined relative to a reference field, the black body at the local material temperature. This choice of reference field removes the cancellation between thermal emission and absorption that is responsible for noise in the Monte Carlo solution of thick systems, but introduces time and space derivative source terms that can not be determined until the end of the time step. It can also lead to noise induced crashes under certain conditions where the real physical photon intensity differs strongly from a black body at the local material temperature. In this report, we consider a difference formulation relative to the material temperature at the beginning of the time step, and in the situations where the radiation intensity more closely follows a temperature other than the local material temperature, that temperature. The result is a method where iterative solution of the material energy equation is efficient and noise induced crashes are avoided. To support our contention that the resulting generalized subtraction scheme is robust, and therefore suitable for practical use, we perform a stability analysis in the thick limit where instabilities usually occur.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spin-noise spectroscopy under resonant optical probing conditions: Coherent and nonlinear effects

Highly sensitive Faraday rotation spectroscopy is used to measure the fluctuating magnetization noise of noninteracting rubidium atoms under resonant and nonresonant optical probing conditions. The spin-noise frequency spectra, in conjunction with the probe light detuning with respect to the D{sub 2} transition, reveal clear signatures of coherent coupling of the participating electronic levels. The results are explained by extended Bloch equations, including homogeneous and inhomogeneous broadening mechanisms. Our measurements further indicate that spin noise originating from excited states is governed at high intensities by collective effects.

74 ATOMIC AND MOLECULAR PHYSICS↗

Massively distributed fiber strain sensing using Brillouin lasing

Brillouin based distributed fiber sensors present a unique set of characteristics amongst fiber sensing architectures. They are able to measure absolute strain and temperature over long distances, with high spatial resolution, and very large dynamic range in off-the-shelf fiber. However, Brillouin sensors traditionally provide only modest sensitivity due to the weak dependence of the Brillouin frequency on strain and the high signal to noise ratio required to identify the resonance’s peak frequency to within a small fraction of its linewidth. Recently, we introduced a technique which substantially improves the precision of Brillouin fiber sensors by exciting a series of lasing modes in a fiber loop cavity that experience Brillouin amplification at discrete locations in the fiber. The narrow-linewidth and high intensity of the lasing modes enabled ultra-low noise Brillouin sensors with large dynamic range. However, our initial demonstration was only modestly distributed: measuring strain at 40, non-contiguous positions along a 400 m fiber. In this work, we greatly extend this methodology to enable fully distributed sensing at 1000 contiguous locations along 3.5 km of fiber—an order of magnitude increase in sensor count and range. This highly-multiplexed Brillouin fiber laser sensor provides a strain noise as low as 34 nɛ/√Hz and we analyze the limiting factors in this approach.

47 OTHER INSTRUMENTATION↗

BVI impulsive noise reduction by higher harmonic pitch control - Results of a scaled model rotor experiment in the DNW

Results are presented of a model rotor acoustics test performed to examine the benefit of higher harmonic control (HHC) of blade pitch to reduce blade-vortex interaction (BVI) impulsive noise. A dynamically scaled, four-bladed, rigid rotor model, a 40-percent replica of the B0-105 main rotor, was tested in the German Dutch Wind Tunnel. Noise characteristics and noise directivity patterns as well as vibratory loads were measured and used to demonstrate the changes when different HHC schedules were applied. Dramatic changes of the acoustic signatures and the noise radiation directivity with the HHC phase variations are found. Compared to the baseline conditions (without HHC), significant mid-frequency noise reductions of locally 6 dB are obtained for low-speed descent conditions where GVI is most intense. For other rotor operating conditions with less intense BVI there is less or no benefit from the use of HHC. LF noise and vibratory loads, especially at optimum noise reduction control settings, are found to increase.

Splettstoesser, Wolf R.↗

Influence of Gaussian white noise on the frequency-dependent first nonlinear polarizability of doped quantum dot

We investigate the profiles of diagonal components of frequency-dependent first nonlinear (β{sub xxx} and β{sub yyy}) optical response of repulsive impurity doped quantum dots. We have assumed a Gaussian function to represent the dopant impurity potential. This study primarily addresses the role of noise on the polarizability components. We have invoked Gaussian white noise consisting of additive and multiplicative characteristics (in Stratonovich sense). The doped system has been subjected to an oscillating electric field of given intensity, and the frequency-dependent first nonlinear polarizabilities are computed. The noise characteristics are manifested in an interesting way in the nonlinear polarizability components. In case of additive noise, the noise strength remains practically ineffective in influencing the optical responses. The situation completely changes with the replacement of additive noise by its multiplicative analog. The replacement enhances the nonlinear optical response dramatically and also causes their maximization at some typical value of noise strength that depends on oscillation frequency.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The flux ratio of the [N II] λ λ 6548, 6583 Å lines in sample of Active Galactic Nuclei Type 2

In spectra of the Active Galactic Nuclei (AGNs), the [N II]λλ 6548, 6583 Å lines are commonly fitted using the fixed intensity ratio of these two lines (R [NII] = I 6583 /I 6548 ). However, the used values for fixed intensity ratio are slightly different through literature. There are several theoretical calculations of the transition probabilities which can be used for the line ratio estimation, but there are no experimental measurements of this ratio, since the [N II] lines are extremely weak in laboratory plasma. Therefore, the intensity ratio of [N II] lines can be measured only in the spectra of astrophysical objects. However, precise and systematic measurements have not be done so far, because of difficulties in measurement of the [N II] ratio in various spectra (overlapping with Hα, weak intensity of [N II], influence of the continuum noise and outflow contribution, etc.). Here we present the measurements of the flux ratio of the [N II] λλ 6548, 6583 Å emission lines for a sample of 250 Type 2 AGNs spectra taken form Sloan Digital Sky Survey (SDSS) data base. Further, the spectra are chosen to have high signal-to-noise ratio and to [N II] and Hα lines do not overlap. The obtained mean flux ratio from measurements is 3.049 ± 0.021. Our result is in agreement with theoretical result obtained by taking into account the relativistic corrections to the magnetic dipole operator.

79 ASTRONOMY AND ASTROPHYSICS↗

Point matching: A new electronic method for homogenizing the phase characteristics of giant magnetoimpedance sensors

Recently, our research group at PUC-Rio discovered that magnetic transducers based on the impedance phase characteristics of GMI sensors have the potential to multiply by one hundred the sensitivity values when compared to magnitude-based GMI transducers. Those GMI sensors can be employed in the measurement of ultra-weak magnetic fields, which intensities are even lower than the environmental magnetic noise. A traditional solution for cancelling the electromagnetic noise and interference makes use of gradiometric configurations, but the performance is strongly tied to the homogeneity of the sensing elements. This paper presents a new method that uses electronic circuits to modify the equivalent impedance of the GMI samples, aiming at homogenizing their phase characteristics and, consequently, improving the performance of gradiometric configurations based on GMI samples. It is also shown a performance comparison between this new method and another homogenization method previously developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visualizing dispersive features in 2D image via minimum gradient method

Here, we developed a minimum gradient based method to track ridge features in a 2D image plot, which is a typical data representation in many momentum resolved spectroscopy experiments. Through both analytic formulation and numerical simulation, we compare this new method with existing DC (distribution curve) based and higher order derivative based analyses. We find that the new method has good noise resilience and enhanced contrast especially for weak intensity features and meanwhile preserves the quantitative local maxima information from the raw image. An algorithm is proposed to extract 1D ridge dispersion from the 2D image plot, whose quantitative application to angle-resolved photoemission spectroscopy measurements on high temperature superconductors is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗