Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NIOBATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Additive Manufacturing of Energy Harvesting Material System for Active Wireless MEMS Sensors

Combustion systems make up a large sum of the world’s yearly energy production despite advances in renewable energy sources. Precise control of pressure and temperature in combustion chambers allows for lower carbon emissions, and overall higher efficiency. Wireless temperature and pressure sensors are critical for the operation of combustion chambers. Energy harvesters have emerged as a viable way to power wireless sensors when heat and mechanical energy are available. Lithium niobate (LNB), barium titanate (BTO), and lead zirconate titanate (PZT) pyroelectric ceramics were studied and fabricated through additive manufacturing (AM) for use as energy harvesting structures in combustion environments. The electric power generation potential of LNB and PZT ceramics was studied by varying the temperature from 50 to 60 °C and by introducing cyclic compression loads of 2000 N amplitude. It was found that thermal energy conversion had the highest output of 500 nW and that combined thermal and mechanical conversion did not increase the harvesting potential because of the competing contributions of both effects. Powder bed and slurry extrusion AM methods were used to fabricate BTO and PZT ceramic structures. Optimization of the powder-based binder jetting method produced BTO ceramics with a relative density of 36.77% a piezoelectric coefficient of 153 pC/N. The density of the ceramics increased up to 56% when increasing the saturation of binder in the powder to because of liquid phase sintering. Finally, PZT structures were manufactured through AM and fin features were added to the design to enhance the heat transfer along the material. The harvested power density of the flat samples was 3.643 μW/cm 3 and of the finned samples was 3.034 μW/cm3. This research paves the ways for the development of self-powered wireless sensors in critical areas of operation such as combustion.

01 COAL, LIGNITE, AND PEAT↗

Rapid charging made practical in graphite-based lithium batteries: surface-acoustic wave turbulent electrolyte mixing to overcome diffusion limited charging rates [Final Report]

One of the key limits in rapidly recharging a lithium-ion battery is the depletion of lithium ions within the electrolyte adjacent the anode during charging and long diffusion time to overcome this depletion. It also causes dendrite formation, inefficient use of the lithium, and battery degradation over many charge-discharge cycles. Because the liquid electrolyte remains quiescent and unmixed, this depletion layer’s depth rapidly grows to match the anode-cathode separation distance at even modest charge rates. The solution proposed by PI Prof. James Friend and Co-PI Prof. Ping Liu, both from the University of California, San Diego, is to mix the electrolyte and minimize the Li+ ion concentration gradient during charging. Even in the presence of the separator, the charging rate could then be significantly increased. They propose to accomplish this using surface acoustic wave (SAW)-driven acoustic streaming, a technique employing 10-mW fingernail-sized solid-state devices from the telecommunications industry to drive turbulent mixing to submicron length scales in a manner completely compatible with the typical 20700 and 18650 cells used in electric vehicles. 0.1. Turbulent acoustic streaming mixes the electrolyte during charging—even with separator Our proposed 100-MHz SAW device used to recirculate the electrolyte is compatible with lithium- ion battery electrochemistry, as it is made in our lab of single-crystal lithium niobate. Their solution is straightforward to drive from a DC power source alongside the signal provided during battery charging. The device is only needed during charging and does not consume power dur- ing battery discharge. Uniquely, SAW generates extreme accelerations of over 1 billion meters per second squared in the fluid, driving turbulent mixing from centimeter to submicron length scales, even through the porous separator materials that tend to be used in batteries, all while avoiding interfering with the anode’s solid electrolyte interphase layer that forms during use. By employing novel fluid mechanics, the investigators are proposing a new direction for battery research away from direct use of materials science and electrochemistry. The chemistry agnostic solution may be employed in any battery chemistry that makes use of liquid electrolytes, providing a broader transformative benefit to the battery research community. They are to produce a series of prismatic and 20700-cell sized 2 Ah batteries capable of being charged and discharged at least 500 times without more than 20% loss in battery capacity, and to provide analysis tools useful to the battery research and development community for adopting this approach for other battery chemistries and configurations.

25 ENERGY STORAGE↗

Irradiation Behavior of Piezoelectric Materials for Nuclear Reactor Sensors

In-situ measurement of surface acoustic wave (SAW) resonators were used to characterize piezoelectric materials behavior in a nuclear reactor environment. Lithium niobate and aluminum nitride devices were tested up to 500°C temperature and 450 kW reactor power (1.9x10 12 n/cm 2 s). The resonant frequency responds to step changes in temperature and power. Materials’ response are inferred from the observed resonant frequency changes, in particular the kinetic behavior is used to determine mechanisms responsible for observed changes. The observed response is attributed to two mechanisms: temperature increase from gamma heating and accumulation of radiation-induced defects. Both of these mechanisms alter the physical properties of the piezoelectric materials, particularly the elastic constants. The demonstrated repeatability and reliability of SAW devices are attractive for sensor applications in extreme environments.

36 MATERIALS SCIENCE↗

Development of electro-optical quantum transducers based on three-dimensional superconducting cavities

Quantum transducers enable the conversion of quantum information and signals between different physical platforms. Based on the pioneering works in three-dimensional superconducting cavity technology developed at Fermilab, we are advancing the development of three-dimensional microwave-optical transducers and exploring their applications in quantum information processing and sensing. We present our progress in the design, fabrication, and characterization of three-dimensional microwave cavities integrated with bulk lithium niobate resonators. The material characterization using three-dimensional cavities based on a resonant-type method allows for understanding of complex permittivity and loss mechanism of electro-optic materials at cryogenic temperatures. We also evaluate the potential of the high-efficiency quantum transducers in enhancing the performance of quantum sensors for applications such as dark matter detection, compared to conventional homodyne detection approaches. This manuscript has been authored by Fermi Research Alliance, LLC under Contract No. DE-AC0207CH11359 with the U.S. Department of Energy, Office of Science, Office of High Energy Physics. This work is funded by the DOE's Early Career Research Program. This research used resources of the U.S. Department of Energy, Office of Science, National Quantum Information Science Research Centers, Superconducting Quantum Materials and Systems Center (SQMS) under Contract No. DE-AC02-07CH11359.

Zorzetti, Silvia↗

Electro-optic Laser-Sampled Neutron Detector

A new method of detecting radiation which can allow for long distance measurements is being investigated. The device is primarily for neutrons detection althought it could, in principle, be used for gamma ray detection. The neutron detection medium is a solid, transparent, electro-optical material, such as lithium niobate, lithium tantalite, or barium borate. Crystals of these materials act as optical gates to laser light, allowing light to pass through only when a neutron interaction occurs in the crystal. Typical light detection devices, such as CCD cameras or photomultiplier tubes, can be used to signal when light passes through the crystal. The overall goal of the project is to investigate the feasibility of such devices for the detection of neutron radiation and to quantify their capabilities and limitations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Intelligent front-end sample preparation tool using acoustic streaming.

We have successfully developed a nucleic acid extraction system based on a microacoustic lysis array coupled to an integrated nucleic acid extraction system all on a single cartridge. The microacoustic lysing array is based on 36{sup o} Y cut lithium niobate, which couples bulk acoustic waves (BAW) into the microchannels. The microchannels were fabricated using Mylar laminates and fused silica to form acoustic-fluidic interface cartridges. The transducer array consists of four active elements directed for cell lysis and one optional BAW element for mixing on the cartridge. The lysis system was modeled using one dimensional (1D) transmission line and two dimensional (2D) FEM models. For input powers required to lyse cells, the flow rate dictated the temperature change across the lysing region. From the computational models, a flow rate of 10 {micro}L/min produced a temperature rise of 23.2 C and only 6.7 C when flowing at 60 {micro}L/min. The measured temperature changes were 5 C less than the model. The computational models also permitted optimization of the acoustic coupling to the microchannel region and revealed the potential impact of thermal effects if not controlled. Using E. coli, we achieved a lysing efficacy of 49.9 {+-} 29.92 % based on a cell viability assay with a 757.2 % increase in ATP release within 20 seconds of acoustic exposure. A bench-top lysing system required 15-20 minutes operating up to 58 Watts to achieve the same level of cell lysis. We demonstrate that active mixing on the cartridge was critical to maximize binding and release of nucleic acid to the magnetic beads. Using a sol-gel silica bead matrix filled microchannel the extraction efficacy was 40%. The cartridge based magnetic bead system had an extraction efficiency of 19.2%. For an electric field based method that used Nafion films, a nucleic acid extraction efficiency of 66.3 % was achieved at 6 volts DC. For the flow rates we tested (10-50 {micro}L/min), the nucleic acid extraction time was 5-10 minutes for a volume of 50 {micro}L. Moreover, a unique feature of this technology is the ability to replace the cartridges for subsequent nucleic acid extractions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Role of Helium on Ejecta Production in Copper

The effect of helium (He) concentration on ejecta production in OFHC-Copper was investigated using Richtmyer–Meshkov Instability (RMI) experiments. The experiments involved complex samples with periodic surface perturbations machined onto the surface. Each of the four target was implanted with a unique helium concentration that varied from 0 to 4000 appm. The perturbation’s wavelengths were λ ≈ 65 μ m, and their amplitudes h 0 were varied to determine the wavenumber ( 2 π / λ ) amplitude product k h 0 at which ejecta production beganfor Cu with and without He. The velocity and mass of the ejecta produced was quantified using Photon Doppler Velocimetry (PDV) and Lithium-Niobate (LN) pins, respectively. Our results show that there was an increase of 30% in the velocity at which the ejecta cloud was traveling in Copper with 4000 appm as compared to its unimplanted counterpart. Our work also shows that there was a finer cloud of ejecta particles that was not detected by the PDV probes but was detected by the early arrival of a “signal” at the LN pins. While the LN pins were not able to successfully quantify the mass produced due to it being in the solid state, they did provide information on timing. Our results show that ejecta was produced for a longer time in the 4000 appm copper.

36 MATERIALS SCIENCE↗

Rapid Nucleic Acid Extraction and Purification Using a Miniature Ultrasonic Technique

Miniature ultrasonic lysis for biological sample preparation is a promising technique for efficient and rapid extraction of nucleic acids and proteins from a wide variety of biological sources. Acoustic methods achieve rapid, unbiased, and efficacious disruption of cellular membranes while avoiding the use of harsh chemicals and enzymes, which interfere with detection assays. In this work, a miniature acoustic nucleic acid extraction system is presented. Using a miniature bulk acoustic wave (BAW) transducer array based on 36° Y-cut lithium niobate, acoustic waves were coupled into disposable laminate-based microfluidic cartridges. To verify the lysing effectiveness, the amount of liberated ATP and the cell viability were measured and compared to untreated samples. The relationship between input power, energy dose, flow-rate, and lysing efficiency were determined. DNA was purified on-chip using three approaches implemented in the cartridges: a silica-based sol-gel silica-bead filled microchannel, nucleic acid binding magnetic beads, and Nafion-coated electrodes. Using E. coli, the lysing dose defined as ATP released per joule was 2.2× greater, releasing 6.1× more ATP for the miniature BAW array compared to a bench-top acoustic lysis system. An electric field-based nucleic acid purification approach using Nafion films yielded an extraction efficiency of 69.2% in 10 min for 50 µL samples.

59 BASIC BIOLOGICAL SCIENCES↗

Thermochemical Measurements of Alkali Cation Association to Hexatantalate

Ion association is an important process in aqueous dissolution, precipitation, and crystallization of ionic inorganic, organic, and biological materials. Polyoxometalates (POMs) are good model compounds for understanding the complex relationships between lattice energy, ion-pairing in solution, and salt solubility. Here we perform calorimetric measurements to elucidate trends in cluster stability, lattice energy, and ion-pairing behavior studies of simple hexatantalate salts in neat water, parent hydroxide solutions, and molybdate melts, extending previous studies on the isostructural hexaniobates. High temperature calorimetry of alkali salts of hexatantalate reveals that the enthalpies of formation from oxides of the K, Rb, and Cs salts are more similar to each other than they are for their niobate analogues and that the tantalate cluster is energetically less stable than hexaniobate. Aqueous dissolution calorimetry reveals that the cesium salt of hexatantalate has a similar concentration dependence on its dissolution enthalpy to that of hexaniobate. However, unlike rubidium hexaniobate, rubidium hexatantalate also exhibits increased concentration dependence, indicating that hextantalate can undergo increased ion-pairing with alkali salts other than cesium, despite the dilute environments studied. Dissolution enthalpies of POM salts in the parent alkali hydroxides shows that protonation of clusters stabilizes lattices even more than the strongly associating heavy alkali cations do. Additionally, neither weak nor strong lattice ion associations necessarily correlates with respectively high or low aqueous solubility. These studies illuminate the importance of considering ion-pairing among the interrelated processes in the aqueous dissolution of ionic salts that can be extended to serving as a model of cation association to metal oxide surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visible CW parametric oscillator.

Tunable optical continuous wave parametric oscillator using 5145 angstrom Ar laser pump and lithium niobate as nonlinear material, noting large oscillation bandwidth

Byer, R. L.↗

Acousto-optic tunable filter.

Electronically tunable lithium niobate optical filter utilizing collinear acousto-optic diffraction in anisotropic medium

Harris, S. E.↗