Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Derivation of at-birth neutron energy distribution of americium-beryllium source based on ISO8529 spectral data

In many practical applications, the accuracy of neutron transport calculations depends on an estimate of the energy distribution provided in the source definition. While the energy distribution of neutrons emitted by spontaneous fission sources is well-defined, the spectra of neutrons produced in (α,n) reactions in compound mixtures, such as americium-beryllium (AmBe), depend on the microstructural properties of the source material, which may vary. Although the energy of neutrons produced in nuclear reactions can be calculated from first principles, such computations require detailed knowledge of the key characteristics of the source material, which are often unknown. Here, this study focuses on deriving the at-birth neutron energy distribution for an AmBe source by applying reverse transport calculations to the externally measured high-precision spectrum recommended in the latest revision of the international standard. The derived at-birth spectrum was validated through indirect energy-sensitive neutron emission rate measurements of AmBe sources calibrated at national primary metrology institutions. The resulting at-birth neutron energy distribution serves as essential input data for radiation transport modeling, providing a validated spectrum for broader experimental and computational applications.

AmBe↗

Characterization of the Fast-Neutron Irradiator and the Fast-Flux Tube Irradiation Fixtures at the Pennsylvania State Breazeale Reactor

Accurate knowledge of the neutron spectrum at a nuclear research reactor is a prerequisite for planning irradiation experiments, as well as for evaluating irradiation exposure results. The neutron-flux spectrum in the fast-neutron irradiator (FNI) and the fast-flux tube (FFT) irradiation fixtures at the Pennsylvania State Breazeale Reactor (PSBR) were characterized using the multi-foil neutron activation method. These irradiation fixtures make use of graded shielding to produce unique neutron fields. Multiple foil sets were irradiated in the fixtures with different exposure times and reactor powers to understand the stability over a wide range of operating conditions. Measured results were evaluated against a MCNP6 simulation to produce a measurement-informed neutron flux-energy spectrum for each fixture using STAYSL_PNNL. Simulated estimates of the FNI fixture, a newer fixture (~25 years old), demonstrated excellent agreement with measured results; the FFT did not. Thermal neutron measurements from the FFT suggest there is additional thermal leakage not captured in the simulation model. In conclusion, possible explanations for the discrepancy include burn-out or degradation (i.e., micro-cracking, gaps, etc.) in the boral and cadmium liners over the lifetime of the fixture (~40 years old).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulations of neutron unbound physics for Geant4

The study of neutron unbound systems via the invariant mass technique is the primary focus of the MoNA Collaboration, which built and operates the Modular Neutron Array (MoNA) and the Large multi-Institutional Scintillator Array (LISA) at FRIB. Advancements in nuclear structure from theory and experiment along the neutron dripline have presented opportunities to understand the nature of unbound systems in higher mass nuclei. The GEometry ANd Tracking (Geant4) platform has been used in high-energy and nuclear physics to simulate particle interactions with as much detail as the user desires. Geant4 currently does not have a physics class to simulate neutron unbound systems. Given the advancement of accelerator facilities and active searches along the neutron dripline, detailed simulations to study the breakup of neutron unbound systems, are necessary. Furthermore, the implementation of the breakup of neutron unbound systems in Geant4 will be presented.

Neutron dripline↗

A novel photomultiplier tube neutron time-of-flight detector

A traditional neutron time-of-flight (nTOF) detector used in inertial confinement fusion consists of a scintillator coupled with a photomultiplier tube (PMT). The instrument response function (IRF) of such a detector is dominated by the scintillator-light decay. At DT neutron yields larger than 1013 a novel detector consisting of a microchannel-plate photomultiplier tube in a housing without a scintillator (PMT nTOF) can be used to measure DT yield, ion temperature, and neutron velocity. Most of the neutron signal in PMT nTOF is produced from neutron interaction with a PMT window. The direct interaction of neutrons with MCP has negligible contribution. The elimination of the scintillator removes the scintillator decay from the instrument response function and makes the IRF of the PMT nTOF faster, which makes the ion temperature and neutron velocity measurements more accurate. Three PMT nTOFs were deployed on the OMEGA Laser System for the first time to diagnose inertial confinement fusion plasma. Here, the design details, characteristics, and calibration results of these detectors in DT implosions on OMEGA are presented. Recommendations on the use of different PMTs for specific applications are provided.

47 OTHER INSTRUMENTATION↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Neutron stars and the dense matter equation of state

The past two decades have witnessed tremendous progress in understanding the properties of neutron stars, their maximum mass and radii, and the properties of the dense matter in their cores, made possible by electromagnetic observations of neutron stars and the detection of gravitational waves from their mergers. These observations have provided novel constraints on neutron-star structure that are intimately related to the properties of dense neutron-rich matter described by the nuclear equation of state. Nevertheless, constraining the equation of state over the wide range of densities probed by astrophysical observations is still challenging, as the physics involved is broad and the system spans many orders of magnitude in density. Here, theoretical approaches to calculate and model the neutron-star equation of state in various regimes of densities are reviewed, and the related consequent properties of neutron stars are discussed. How the equation of state at low densities can be calculated from nuclear interactions that are constrained and benchmarked by nuclear experiments is described. Neutron-star observations, with a particular emphasis on information provided by gravitational-wave signals and electromagnetic observations, are reviewed. Finally, future challenges and opportunities in the field are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron sub-micrometre tomography from scattering data

Neutrons are valuable probes for various material samples across many areas of research. Neutron imaging typically has a spatial resolution of larger than 20 µm, whereas neutron scattering is sensitive to smaller features but does not provide a real-space image of the sample. A computed-tomography technique is demonstrated that uses neutron-scattering data to generate an image of a periodic sample with a spatial resolution of ∼300 nm. The achieved resolution is over an order of magnitude smaller than the resolution of other forms of neutron tomography. This method consists of measuring neutron diffraction using a double-crystal diffractometer as a function of sample rotation and then using a phase-retrieval algorithm followed by tomographic reconstruction to generate a map of the sample's scattering-length density. Topological features found in the reconstructions are confirmed with scanning electron micrographs. This technique should be applicable to any sample that generates clear neutron-diffraction patterns, including nanofabricated samples, biological membranes and magnetic materials, such as skyrmion lattices.

nanoscience↗

Measured Energy-Dependent Neutron Attenuation Through the Stacked Printed Circuit Boards

Engineers often stack printed circuit boards (PCBs), populated with semiconductor devices, one behind the other in neutron beams to improve the error statistics in radiation-effects tests. As the neutron beam traverses through the boards, the neutron flux is both attenuated and the energy spectrum changes, which may have a significant impact on the results of such tests. In this work, we have developed a technique to measure the energy-dependent neutron attenuation due to the PCBs and to determine the energy-dependent effective cross section of neutron interactions with a single PCB. With this effective cross section, engineers can calculate the change in the neutron energy spectrum and the total neutron attenuation after any number of identical PCBs in the stack. This information will allow test engineers to partially correct inaccuracies in soft error tests.

42 ENGINEERING↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Predicting deviations in ex-core detector response in Krsko NPP during an earthquake with Monte-Carlo neutron transport methods

To study the response of ex-core detectors during an earthquake, an approach using Monte Carlo code MCNP was developed. As a first step to predict the response of the ex-core detectors a detailed MCNP model of the Krsko reactor core was created. A detailed MCNP core model was used to calculate 3D power distributions inside the core. Calculated power distributions were verified by comparison to the CORD-2 calculations, which is currently used for core design calculation verification of the Krsko nuclear power plant. Due to the outside the core position of the neutron detectors, the hybrid code ADVANTG is used to generate weight windows to speed up neutron transport outside the reactor core. To be able to use ADVANTG, fixed neutron source had to be reconstructed from the criticality core calculation. It was found that the power range ex-core detector movement has a negligible effect on the value of the thermal neutron flux at the active part of the detector. However, the 5 cm radial movement of the intermediate-range detector leads to 7 % - 8 % change in thermal neutron flux within the active intermediate-range detector region. The analysis continued with the evaluation of the effect of core barrel movement on the ex-core detector response. It was determined that the 2 mm core barrel radial oscillation can lead to ∼ 4% change in thermal neutron flux within the active detector region. It was evaluated that reactor core movement inside the baffle can lead up to ∼ 1.9% and ∼ 1.3% deviation in power-range and intermediate-range detector signal respectively. Analysis showed that the mechanical movement of ex-core neutron detectors could not explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

D retention and depth profile behavior for single crystal tungsten with high temperature neutron irradiation

Single crystalline W (tungsten) samples irradiated at 633, 963 and 1073 K by neutrons to a damage level of 0.1 dpa were exposed to a high-flux D (deuterium) plasma at 673, 873 and 973 K, respectively, in TPE (Tritium Plasma Experiment) at INL (Idaho National Laboratory). Deuterium desorption was analyzed by TDS (Thermal Desorption Spectroscopy), and D depth profiles were determined by NRA (Nuclear Reaction Analysis) at SNL (Sandia National Laboratories). HIDT (Hydrogen Isotope Diffusion and Trapping) simulation code was applied to evaluate D behavior for neutron-damaged W at higher temperature. The D retention at depths up to 3 f.tm for the neutron-damaged sample at 673 K was two orders of magnitude larger than that for undamaged tungsten, and its D desorption spectrum had a single broad stage at around 900 K. As the neutron irradiation/plasma exposure temperature increased, D retention was largely reduced, and the desorption temperature was increased to higher temperatures above 1100 K. The D depth profiles by NRA also showed D migration toward bulk by higher temperature irradiation, compared to undamaged W. The HIDT simulation indicated that the major binding energy of D was changed from 1.43 eV to 2.07 eV at higher neutron irradiation and plasma exposure temperatures, suggesting that some vacancies and small vacancy clusters would aggregate to form larger voids, or depopulation of weak traps at high D plasma exposure temperatures. It can be said that more stable trapping sites played dominant roles in the D retention at higher neutron irradiation and plasma exposure temperature. The binding energy by HIDT simulation was almost consistent with the reported value by TMAP, but the consideration of not only total D retention measured by TDS but also D depth profile by NRA led to the more accurate D behavior in neutron-damaged W.

36 MATERIALS SCIENCE↗

Emulation of neutron-irradiated microstructure of austenitic 21Cr32Ni model alloy using dual-ion irradiation

Here, in this study, the capability of heavy-ion irradiation to emulate neutron irradiation was demonstrated on an austenitic 21Cr32Ni type ternary model alloy. The model alloy used in this study is chemically analogous but compositionally simpler than of alloy 800H, which is a candidate austenitic Ni alloy which has been proposed for use in Generation IV reactors. The microstructure of the 21Cr32Ni model alloy irradiated in the BOR-60 fast reactor to 17.1 dpa and 35 dpa at ~380°C was characterized using transmission electron microscopy (TEM). The 17.1 dpa BOR-60 irradiated microstructure was then compared with the microstructure of the same material developed under dual-ion (DI) irradiation using various He/dpa ratios between 0.1 and 16.6 appm He/dpa in the temperature range of 430°C-500°C. The results showed that both neutron and DI irradiation of 21Cr32Ni model alloy produced dislocations in the form of a dislocation network as well as {111}-type faulted dislocation loops, cavities, and radiation-induced Ni enrichment at radiation-induced sinks. When the dose and the He/dpa ratio were kept similar to those in neutron irradiation, DI irradiation of the 21Cr32Ni model alloy at 460°C resulted in over-nucleation of small cavities and in a high density of faulted dislocation loops compared to those observed in the fast-neutron irradiated alloy of the same heat irradiated at ~380°C. The optimal condition for reproducing the neutron-irradiated microstructure was DI irradiation at 460°C and 0.1 appm He/dpa. In that case, the faulted loop and cavity size distributions in the BOR-60 irradiated 21Cr32Ni model alloy samples closely matched with those measured in the DI irradiated 21Cr32Ni model alloy sample. The fact that the He/dpa is an order of magnitude smaller than the helium generation rate for fast neutron irradiation, stops over nucleation and allows for the development of a similar microstructure as for neutron irradiation.

21Cr32Ni model alloy↗

Microstructural evolution and transmutation in tungsten under ion and neutron irradiation

This study aims to compare the effects of neutron and self-ion irradiation on the mechanical properties and microstructural evolution in W. Neutron irradiation at the HFR reactor to 1.67 dpa at 800 °C resulted in the formation of large Re and Os rich clusters and voids. The post-irradiation composition was measured using APT and verfified against FISPACT modelling. The measured Re and Os concentration was used to create alloys with equivalent concentrations of Re and Os. These alloys were exposed to self-ion irradiation to a peak dose of 1.7 dpa at 800 °C. APT showed that self-ion irradiation leads to the formation of small Os clusters, wheras under neutron irradiation large Re/Os clusters form. Voids are formed by both ion and neutron irradiation, but the voids formed by neutron irradiation are larger. By comparing the behaviour of W-1.4Re and W-1.4Re-0.1Os, suppression of Re cluster formation was observed. Irradiation hardening was measured using nanoindentation and was found to be 2.7 GPa, after neutron irradiation and 1.6 GPa and 0.6 GPa for the self-ion irradiated W-1.4Re and W-1.4Re-0.1Os. The higher hardening is attributed to the barrier strength of large voids and Re/Os clusters that are observed after neutron irradiation.

36 MATERIALS SCIENCE↗

A backing detector for order-keV neutrons

In this work, we have designed and tested a large-area (0.15 m 2 ) neutron detector based on neutron capture on 6Li. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These neutron detectors would be employed to calibrate the low-energy (<100 eV) nuclear recoil in detectors for dark matter and coherent elastic neutrino nucleus scattering (CE$\textit{v}$NS). We describe the design, construction, and characterization of a prototype. The prototype is designed to have a tagging efficiency of ~25% at the relevant $\mathcal{O}$(keV) neutron energies, and with a mean capture time of ~ 17 μs. The prototype was characterized using a 252 Cf neutron source and agreement with the simulation was observed within a few percent level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-fidelity photoneutron detection via neutron activation analysis

To interdict illicit radioactive sources and prevent nuclear terror, governments have deployed portal monitor systems at ports of entry. Such portal monitors rely upon the detection of spontaneously-emitted radiation signatures, however, detection scenarios become more challenging for highly enriched uranium, which emits relatively few spontaneous radiation signatures. Photon active interrogation techniques can augment current cargo inspection scenarios and improve detection capabilities for illicit nuclear material. A high-energy photon interrogation source can induce photofission in nuclear material, producing strong radiation signatures for detection. Prompt fission signals are of specific interest because prompt neutrons are greater than 99% of the fission signal. When using detectors capable of spectroscopy, e.g., pulse shape discrimination-capable organic scintillators, the intense interrogating source often will cause pulse pile-up, degrading particle classification. In this work, we demonstrate photoneutron detection via neutron activation of aluminum and iron. The experiments rely upon nuclear reactions that can only be induced by neutrons, and are robust against pile-up, thereby providing high-confidence neutron rates. In this work, we apply neutron activation analysis for the detection of high-energy neutrons produced by high-energy photon irradiation; the depleted uranium sample was irradiated with a 9-MeV bremsstrahlung beam. We find that the irradiated depleted uranium produced an aluminum activation flux of 1.77 × 10 5 n cm –2 s –1 and an iron-56 activation flux of 1.05 × 10 5 n cm –2 s –1 . Furthermore, the ability to detect radioactivity induced by neutrons created in (, n) and photofission reactions demonstrates a new approach for photon active interrogation to identify nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗