At least 505 records · Page 28

A Computational Model for Simulating Spaceflight Induced Bone Remodeling

An overview of an initial development of a model of bone loss due to skeletal unloading in weight bearing sites is presented. The skeletal site chosen for the initial application of the model is the femoral neck region because hip fractures can be debilitating to the overall performance health of astronauts. The paper begins with the motivation for developing such a model of the time course of change in bone in order to understand the mechanism of bone demineralization experienced by astronauts in microgravity, to quantify the health risk, and to establish countermeasures. Following this, a general description of a mathematical formulation of the process of bone remodeling is discussed. Equations governing the rate of change of mineralized bone volume fraction and active osteoclast and osteoblast are illustrated. Some of the physiology of bone remodeling, the theory of how imbalance in remodeling can cause bone loss, and how the model attempts to capture this is discussed. The results of a preliminary validation analysis that was carried out are presented. The analysis compares a set of simulation results against bone loss data from control subjects who participated in two different bed rest studies. Finally, the paper concludes with outlining the current limitations and caveats of the model, and planned future work to enhance the state of the model.

Pennline, James A.↗

Validation of the 5th and 95th Percentile Hybrid III Anthropomorphic Test Device Finite Element Model

NASA spacecraft design requirements for occupant protection are a combination of the Brinkley criteria and injury metrics extracted from anthropomorphic test devices (ATD's). For the ATD injury metrics, the requirements specify the use of the 5th percentile female Hybrid III and the 95th percentile male Hybrid III. Furthermore, each of these ATD's is required to be fitted with an articulating pelvis and a straight spine. The articulating pelvis is necessary for the ATD to fit into spacecraft seats, while the straight spine is required as injury metrics for vertical accelerations are better defined for this configuration. The requirements require that physical testing be performed with both ATD's to demonstrate compliance. Before compliance testing can be conducted, extensive modeling and simulation are required to determine appropriate test conditions, simulate conditions not feasible for testing, and assess design features to better ensure compliance testing is successful. While finite element (FE) models are currently available for many of the physical ATD's, currently there are no complete models for either the 5th percentile female or the 95th percentile male Hybrid III with a straight spine and articulating pelvis. The purpose of this work is to assess the accuracy of the existing Livermore Software Technology Corporation's FE models of the 5th and 95th percentile ATD's. To perform this assessment, a series of tests will be performed at Wright Patterson Air Force Research Lab using their horizontal impact accelerator sled test facility. The ATD's will be placed in the Orion seat with a modified-advanced-crew-escape-system (MACES) pressure suit and helmet, and driven with loadings similar to what is expected for the actual Orion vehicle during landing, launch abort, and chute deployment. Test data will be compared to analytical predictions and modelling uncertainty factors will be determined for each injury metric. Additionally, the test data will be used to further improve the FE model, particularly in the areas of the ATD neck components, harness, and suit and helmet effects.

Lawrence, C.↗

An Overview of NASA's Risk of Cardiovascular Disease from Radiation Exposure

The association between high doses of radiation exposure and cardiovascular damage is well established. Patients that have undergone radiotherapy for primary cancers of the head and neck and mediastinal regions have shown increased risk of heart and vascular damage and long-term development of radiation-induced heart disease [1]. In addition, recent meta-analyses of epidemiological data from atomic bomb survivors and nuclear industry workers has also shown that acute and chronic radiation exposures is strongly correlated with an increased risk of circulatory disease at doses above 0.5 Sv [2]. However, these analyses are confounded for lower doses by lifestyle factors, such as drinking, smoking, and obesity. The types of radiation found in the space environment are significantly more damaging than those found on Earth and include galactic cosmic radiation (GCR), solar particle events (SPEs), and trapped protons and electrons. In addition to the low-LET data, only a few studies have examined the effects of heavy ion radiation on atherosclerosis, and at lower, space-relevant doses, the association between exposure and cardiovascular pathology is more varied and unclear. Understanding the qualitative differences in biological responses produced by GCR compared to Earth-based radiation is a major focus of space radiation research and is imperative for accurate risk assessment for long duration space missions. Other knowledge gaps for the risk of radiation-induced cardiovascular disease include the existence of a dose threshold, low dose rate effects, and potential synergies with other spaceflight stressors. The Space Radiation Program Element within NASA's Human Research Program (HRP) is managing the research and risk mitigation strategies for these knowledge gaps. In this presentation, we will review the evidence and present an overview of the HRP Risk of Cardiovascular Disease and Other Degenerative Tissue Effects from Radiation Exposure.

Patel, Zarana S.↗

Comparison of Venous Return Characteristics with Right Ventricular Mechanics During Cephalic Fluid Shift

For my summer internship project, I organized a pilot study to analyze the effects of a cephalic fluid shift on venous return and right ventricular mechanics to increase right ventricular and venous knowledge. To accomplish this pilot study, I wrote a testing protocol, obtained Institutional Review Board (IRB) approval, completed subject payment forms, lead testing sessions, and analyzed the data. This experiment used -20deg head down tilt (20 HDT) as the ground based simulation for the fluid shift that occurs during spaceflight and compared it to data obtained from the seated and supine positions. Using echocardiography, data was collected for the right ventricle, hepatic vein, internal jugular vein, external jugular vein, and inferior vena cava. Additionally, non-invasive venous pressure measurements, similar to those soon to be done in-orbit, were collected. It was determined that the venous return from below the heard is increased during 20 HDT, which was supported by increased hepatic vein velocities, increased right ventricular inflow, and increased right ventricular strain at 20 HDT relative to seated values. Jugular veins in the neck undergo an increase in pressure and area, but no significant increase in flow, relative to seated values when a subject is tilted 20 HDT. Contrary to the initial expectations based on this jugular flow, there was no significant increase in central venous pressure, as evidenced by no change in Doppler indices for right arterial pressure or inferior vena cava diameter. It is suspected that these differences in pressure are due to the hydrostatic pressure indifference point shifting during tilt; there is a potential for a similar phenomenon with microgravity. This data will hopefully lead to a more in-depth understanding of the response of the body to microgravity and how those relate to the previously mentioned cardiovascular risk of fluid shift that is associated with spaceflight. These results were presented in greater detail to the Cardiovascular Laboratory and the Space Life Science Summer Institute, which helped me prepare for future graduate school research presentations. This internship allowed me to apply and expand the anatomy, physiology, and mechanics information I learned during my undergraduate degree in Biomedical Engineering to the cardiovascular system with the unique zero gravity perspective. Additionally, I was able to develop skills with data analysis techniques involving speckle tracking for ventricular strain and Doppler waveforms for blood velocities. Additionally, I was able to expand upon my previous work in the Cardiovascular Laboratory by writing a literature review on a data analysis project I completed last summer. Ultimately, this internship and venous relationship comparison project provided me with a significant learning experience and additional skill sets, which are applicable to my goals of attaining a Ph.D. in biomedical engineering with a focus on tissue engineering and the cardiovascular system.

Elliott, Morgan↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

Providing adequate carbon dioxide (CO2) washout is essential to the reduction of risk in performing suited operations. Long term CO2 exposure can lead to symptoms such as headache, lethargy, dizziness, and in severe cases can lead to unconsciousness and death. Thus maintaining adequate CO2 washout in both ground testing and during in flight EVAs is a requirement of current and future suit designs. It is necessary to understand the inspired CO2 of suit wearers such that future requirements for space suits appropriately address the risk of inadequate washout. Testing conducted by the EVA Physiology Laboratory at the NASA Johnson Space Center aimed to characterize a method for noninvasively measuring inspired oronasal CO2 under pressurized suited conditions in order to better inform requirements definition and verification techniques for future CO2 washout limits in space suits. Prior work conducted by the EPL examined several different wearable, respirator style, masks that could be used to sample air from the vicinity surround the nose and mouth of a suited test subject. Previously published studies utilized these masks, some being commercial products and some novel designs, to monitor CO2 under various exercise and flow conditions with mixed results for repeatability and/or consistency between subjects. Based on a meta-analysis of those studies it was decided to test a nasal cannula as it is a commercially available device that is placed directly in the flow path of the user as they breathe. A nasal cannula was used to sample air inhaled by the test subjects during both rest and exercise conditions. Eight subjects were tasked with walking on a treadmill or operating an arm ergometer to reach target metabolic rates of 1000, 2000, and 3000 BTU/hr. Suit pressure was maintained at 4.3 psid for all tests, with supply flow rates of 6, 4, and 2 actual cubic feet per minute depending on the test condition. Each test configuration was conducted twice with subjects breathing either through their nose only, or however they felt comfortable. By restricting breathing through a single orifice, we are able to more accurately define exactly what flow stream the sampled CO2 is taken from. Oronasal CO2 was monitored using real time infrared gas analyzers fed via sample tubes connected to the nasal cannula within the suit. Two additional sampling tubes were placed at the head and chin of the test subject, in an effort to capture CO2 concentrations across the entire flow stream of the Mark-III vent system (flow path is head to neck). Metabolic rate was calculated via the exhaust CO2 concentration and used to adjust subject workload on either the treadmill or arm ergometer until the target was reached. Forward work will aim to characterize the historically accepted minimum ppCO2 in suit during EVA by repeating this study in the Extravehicular Mobility Unit (EMU) space suit. This will help to define washout requirements for future suits, be they NASA (e.g. Z-2) or Commercial Crew designed. Additionally it is important to determine the functional consequences of CO2 exposure during EVA. Severe CO2 symptoms are a result of very high concentration, acute exposures. While long term, low concentration exposures have been shown to result in slight cognitive decline, symptoms resolve upon quickly returning to nominal concentrations and it remains unknown the impact that minor deficits in cognitive performance can have on EVA performance.

Norcross, J.↗

Johnson Space Center's Free Range Bicycle Program.- Fall 2015 Intern Report

NASA's Johnson Space Center is a big place, encompassing 1,620 acres and more than a hundred buildings. Furthermore, there are reportedly 15 thousand employees, all of which have somewhere to be. To facilitate the movement of all these people JSC has historically relied on human power. Pedaling their way towards deep space, bicycles have been the go to method. Currently there are about 200 Free Range Bicycles at JSC. Free Range Bicycles belong to nobody, except NASA, and are available for anybody to use. They are not to be locked or hidden (although frequently are) and the intention is that there will always be a bike to hop on to get where you're going (although it may not be the bike you rode in on). Although not without its own shortcomings, the Free Range Bicycle Program has continued to provide low cost, simple transportation for NASA's JSC. In addition to the approximately 200 Free Range Bicycles, various larger divisions (like engineering) will often buy a few dozen bikes for their team members to use or individuals will bring their own personal bike to either commute or use on site. When these bicycles fall into disrepair or are abandoned (from retirees etc) they become a problem at JSC. They are an eye sore, create a safety hazard and make it harder to find a working bike in a time of need. The Free Range Program hopes to address this first problem by "tagging out" abandoned or out of service bicycles. A bright orange "DO NOT OPERATE" tag is placed on the bike and given a serial number for tracking purposes. See picture to the right. If the bike has an active owner with intentions to repair the bike the bottom of the tag has instructions for how to claim the abandoned bicycle. After being tagged the owner of the bicycle has 30 days to claim the bicycle and either haul it off site or get it repaired (and labeled) in accordance with Johnson's Bicycle Policy. If the abandoned bicycle is not claimed within 30 days it becomes the property of the Government. The bicycle is then (in short) repaired, labeled, documented and converted to a free range bicycle. Bikes beyond repair are cannibalized of useable parts and then scrapped. That was nearly the first thing I did when arriving at work. After getting settled in and coordinating the purchase of 50 new bicycles (elaboration below); I started combing the Center. Bikes are hidden and tucked away in the oddest of places and it was my priority to root all of them out. I tagged 70 bikes on the center, setting a record. I tagged so many bikes I ran out tags and had to make more. Long ago it was discovered that the same harsh elements that wreak havoc on the bikes, destroy the tags before the 30 day timeframe. The tags are labeled with instructions on how to claim the bike and numbered, then these paper labels are laminated with packing tape. It sounds like a simple process but nothing fits right, everything has to be trimmed, put on straight and is generally a pain in the neck. So I made an assembly process and knocked out a few hundred to save having to do it again for a while. I walked the center and tagged bikes at every building hiding in nearly every nook and cranny. Thus, in conclusion, I've done many things here at JSC on my first term and had a blast doing it. I've learned a lot from my multi-faceted roles and continual challenges. In short I've done my best to get folks at JSC on bikes and keep folks at JSC on bikes and tended a flock of free range bicycles. Everything from turning the rusty bolts and oiling chains to coordinating a $20,000 deal on 50 new free range bicycles. I am proud of the bicycle shop I have built and am infinitely grateful to the people who lead, help, guide and support me. I have fixed a great number of bicycles and cleaned the center of unsightly and unsafe piles of bicycles. I am immensely thankful for this opportunity to learn and serve and appreciate the privilege of coming back for a second term. A second term, in which I will continue to develop this awesome program.

Lee-Stockton, Willem↗

Simplified Methodology to Estimate the Maximum Liquid Helium (LHe) Cryostat Pressure from a Vacuum Jacket Failure

The aircraft-based Stratospheric Observatory for Infrared Astronomy (SOFIA) is a platform for multiple infrared astronomical observation experiments. These experiments carry sensors cooled to liquid helium temperatures. The liquid helium supply is contained in large (i.e., 10 liters or more) vacuum-insulated dewars. Should the dewar vacuum insulation fail, the inrushing air will condense and freeze on the dewar wall, resulting in a large heat flux on the dewar's contents. The heat flux results in a rise in pressure and the actuation of the dewar pressure relief system. A previous NASA Engineering and Safety Center (NESC) assessment provided recommendations for the wall heat flux that would be expected from a loss of vacuum and detailed an appropriate method to use in calculating the maximum pressure that would occur in a loss of vacuum event. This method involved building a detailed supercritical helium compressible flow thermal/fluid model of the vent stack and exercising the model over the appropriate range of parameters. The experimenters designing science instruments for SOFIA are not experts in compressible supercritical flows and do not generally have access to the thermal/fluid modeling packages that are required to build detailed models of the vent stacks. Therefore, the SOFIA Program engaged the NESC to develop a simplified methodology to estimate the maximum pressure in a liquid helium dewar after the loss of vacuum insulation. The method would allow the university-based science instrument development teams to conservatively determine the cryostat's vent neck sizing during preliminary design of new SOFIA Science Instruments. This report details the development of the simplified method, the method itself, and the limits of its applicability. The simplified methodology provides an estimate of the dewar pressure after a loss of vacuum insulation that can be used for the initial design of the liquid helium dewar vent stacks. However, since it is not an exact tool, final verification of the dewar pressure vessel design requires a complete, detailed real fluid compressible flow model of the vent stack. The wall heat flux resulting from a loss of vacuum insulation increases the dewar pressure, which actuates the pressure relief mechanism and results in high-speed flow through the dewar vent stack. At high pressures, the flow can be choked at the vent stack inlet, at the exit, or at an intermediate transition or restriction. During previous SOFIA analyses, it was observed that there was generally a readily identifiable section of the vent stack that would limit the flow – e.g., a small diameter entrance or an orifice. It was also found that when the supercritical helium was approximated as an ideal gas at the dewar condition, the calculated mass flow rate based on choking at the limiting entrance or transition was less than the mass flow rate calculated using the detailed real fluid model2. Using this lower mass flow rate would yield a conservative prediction of the dewar’s wall heat flux capability. The simplified method of the current work was developed by building on this observation.

Ungar, Eugene K.↗

The Safety Course Design and Operations of Composite Overwrapped Pressure Vessels (COPV)

Following a Commercial Launch Vehicle On-Pad COPV (Composite Overwrapped Pressure Vessels) failure, a request was received by the NESC (NASA Engineering and Safety Center) June 14, 2014. An assessment was approved July 10, 2014, to develop and assess the capability of scanning eddy current (EC) nondestructive evaluation (NDE) methods for mapping thickness and inspection for flaws. Current methods could not identify thickness reduction from necking and critical flaw detection was not possible with conventional dye penetrant (PT) methods, so sensitive EC scanning techniques were needed. Developmental methods existed, but had not been fully developed, nor had the requisite capability assessment (i.e., a POD (Probability of Detection) study) been performed.

Saulsberry, Regor↗

Effects of Long Duration Spaceflight on Venous and Arterial Compliance: Bed Rest

The primary objective was to determine whether a high sodium diet during bed rest induced alterations in vascular compliance and was related to the incidence of VIIP. Ocular structural and functional measures and vascular ultrasound of the head and neck were acquired in bed rest subjects completing 10-14 days in 6deg head-down tilt.

Ribeiro, L. Christine↗

Large Male Anthropomorphic Test Device (ATD) Finite Element Model (FEM) Correlation Improvement

As part of an activity for the Commercial Crew Program (CCP), a NASA Engineering and Safety Center (NESC) team conducted tests of small female, medium male, and large male Hybrid III anthropomorphic test device (ATD) head-neck complexes. The results were compared to simulation results from ATD finite element model (FEM) predictions to determine the validity and fidelity of ATD models for use in certifying CCP vehicles. The NESC was requested to help improve the large male ATD FEM to better represent physical responses. This report contains the outcome of the NESC assessment.

Kelly, Michael J.↗

Lunar Transient Accelerations White Paper

Recently, the United States announced a plan to return astronauts to the moon by 2024 [8]. Lunar landing (and subsequent Mars landing) architecture was not considered when the current NASA standards and vehicle design requirements for crew injury risk were developed. Therefore a gap exists in protecting the crew in planetary landing scenarios. One of the interesting aspects of this design reference mission (DRM)is the consideration of having the crew stand during dynamic phases of flight. Although this approach was contemplated for the Apollo Lunar Module, current NASA standards do not address design solutions that allow the crew to stand. Currently, NASA uses several tools and associated limits to mitigate crew injury because of dynamic loads. Some of these tools are the Brinkley Dynamic Response Criterion (BDRC) model and Hybrid III Anthropomorphic Test Devices (ATDs) [10]; and these have several limitations for assessing spaceflight loading environments, as well as specific underlying assumptions that may not be applicable in planetary landing vehicles. The BDRC is a simple lumped mass parameter model developed by the U.S. military, and has been used primarily to evaluate injury risk associated with aircraft ejection systems. The model evaluates seat accelerations in each axis to determine injury risk. Because the model treats the human-seat-restraint system as a single system, it is contingent on a restraint system and seat with similar characteristics of the original test data underlying the model. In particular, the model requires a rigid seat with a minimum natural frequency of 15Hz, minimal seat pan padding, side supports, and multipoint harness. The BDRC model uses undamped natural frequency and damping coefficients based on these requirements and any deviations may render the model injury predictions void. In lunar landing, one expects that a minimal or even no seat with minimal restraints will be employed. In this case, the original model parameters are likely to not be applicable. For capsule-based spacecraft returning crew to Earth, the Hybrid III ATD in various sizes also is used to supplement the BDRC. This analytical tool was added to address limitations in the BDRC related to spacecraft landings while wearing a pressure garment and helmet. Although the Hybrid III ATD has additional measurement capability; head, neck,and lumbar spine responses were the only metrics included because of the limitations imposed by the model.Lunar landing acceleration limits must assume the crew is standing during landing, an orientation for which we have limited data.Although the Apollo missions did employ a standing orientation for the crew, much of the data is lost. Therefore data from othersources havebeen examined to inform lunar landing acceleration limits.

Jeffrey T Somers↗

Astronaut Kinematics and Injury Risk for Piloted Lunar Landings and Launches While Standing

During future lunar missions, astronauts may be required to pilot vehicles while standing, and the associated kinematic and injury response is not well understood. In this study we used human body modeling to predict unsuited astronaut kinematics and injury risk for piloted lunar launches and landings in the standing posture. Three pulses (2-5 g; 10–150 ms rise times) were applied in 10 directions (vertical; ± 10-degree offsets) for a total of 30 simulations. Across all simulations, motion envelopes were computed to quantify displacement of the astronaut’s head (max 9.0 cm forward, 7.0 cm backward, 2.1 cm upward, 7.3 cm downward, 2.4 cm lateral) and arms (max 25 cm forward, 35 cm backward, 15 cm upward, 20 cm downward, 20 cm lateral). All head, neck, lumbar, and lower extremity injury metrics were within NASA’s tolerance limits, except tibia compression forces (0–1543 N upper tibia; 0–1482 N lower tibia; tolerance—1350 N) and revised tibia index (0.04–0.58 upper tibia; 0.03–0.48 lower tibia; tolerance—0.43) for the 2.7 g/150 ms pulse. Pulse magnitude and duration contributed over 80% to the injury metric values, whereas loading direction contributed less than 3%. Overall, these simulations suggest piloting a lunar lander vehicle in the standing posture presents a low risk of injury to the astronaut, although risk of tibia injury is potentially outside NASA’s acceptance limits and warrants further investigation.

Mitesh Lalwala↗

Pterodactyl: Effects of 3D Thermal Analysis on Thermal Protection System Design for a Flap Control System

NASA’s Pterodactyl project has investigated the use of a novel multi-flap control system to facilitate precision targeting of Deployable Entry Vehicles (DEVs) during atmospheric re-entry [1]. DEVs can be folded to fit within the limiting cross-sectional area of current launch systems. Once deployed, the vehicle expands and settles into a pre-determined blunt body shape. While DEVs provide a more efficient solution to increased payload sizes, the absence of a back shell does not allow for easy integration of reaction control systems, which have historically been used for guidance and control (G&C) of rigid aeroshells during entry. One DEV solution, called the Adaptable, Deployable Entry Placement Technology (ADEPT), employs mechanically deployed gores. This provided the Pterodactyl project with the opportunity to incorporate a rib-mounted, 8-flap control system for G&C. Each flap can deflect independently in and out of the hypersonic flow, requiring TPS for the flaps. Previous work within the Pterodactyl project utilized 1D thermal analysis to design the TPS. However, the Pterodactyl project was concerned that the base level tools for 1D thermal analysis were not accounting for the 3D effects of the large heating gradients along and across the flaps, the in-depth in-plane conductivity of the TPS and internal structure, and the effects of the small edge radii at the neck of the flaps. This paper discusses the methodology and results of a 3D thermal analysis of the flap control system. Additionally, the results from the 1D and 3D thermal analyses are compared. It is found that elements of the original design that resulted from the 1D analysis may be overly conservative, and implementation of a 3D thermal analysis indicated a reduction in TPS thickness is feasible. This result helps to reduce the mechanical integration complexity of the flap at the rib tip and realizes potential mass savings.

Sarah N D'Souza↗

International Standard Measures During the AGBRESA Bed Rest Study

The Artificial Gravity Bed Rest with European Space Agency (AGBRESA) study involved 2 campaigns of 60-day bed rest at 6° head down tilt in the:envihab facility in Cologne, Germany, in 2019. The objective was to determine whether centrifugation of supine subjects mitigates physiological changes that occur due to the exposure to the spaceflight analog of 6° head down tilt. A set of international standard measures was used to evaluate bone, muscle, nutritional status, ocular changes, and psychological state and to assess cardiovascular, sensorimotor, and immune systems functions. After 60 days of bed rest, the subjects who were not exposed to centrifugation had significant decreases in mineral density at the hip and lumbar spine, decreased muscle strength of the knee and ankle, reduced maximal aerobic capacity, orthostatic intolerance, and impaired balance and locomotion, as well as significant biochemical, immunological, and psychological alterations. A daily 30-min exposure to 1 Gz supine centrifugation at the center of mass (0.3 Gz at the head, 2 Gz at the feet) mitigated mineral density loss in the femur neck and lumbar spine; and lessened the effects of bed rest on aerobic capacity, biochemistry, and immunology. However, low statistical power could contribute to the non-significant effects that are reported.

Bed rest↗

Microcalorimeter Absorber Optimization for 0.2 to 12 keV X-Rays

The Advanced Telescope for High ENergy Astrophysics (ATHENA) mission requires high quantum efficiency (QE) x-ray absorption, >90.6% at 7 keV and low specific heat capacity, 0.731 pJ/K. The designed ATHENA x-ray absorbers are cantilevered square tiles (pitch of 317 microns) of 1.05 μm thick Au and 5.51 μm thick Bi electroplated films supported by stems that connect the absorber to the detector below. We discuss some of the methods used to produce x-ray absorbers meeting these specifications for ATHENA. To tune the thermal conductance of the device and the effect on the normal-to superconducting transition shape, the stems need to be small diameter and can have a weak bottle-neck connection to the substrate. A funnel shape of the stem using a proximity exposed photoresist mold has been developed to improve the strength of the connections. Further requirements on the absorbers include low levels of fine particulate remaining on the substrate after production and zero shorts between absorbers due to incomplete ion milling or trapped fine particular between absorbers. To optimize for post patterning substrate cleanliness and absorber yield, we have examined several methods of absorber fabrication. Three such methods are 1) an ion mill/wet etch combination, 2) a photoresist mold for electroplating followed by wet or dry etch to remove the seed layer, and 3) an electroplating process with leveling to smooth the surface followed by ion mill to separate the absorbers. The different combinations of wet and dry etches lead to different yields and surface appearance of the absorber sidewalls. We present results on the achieved pixel yields and the energy resolution of pixels made with the various fabrication methods. We discuss the impact of absorber patterning method on performance, uniformity, and yield.

Edward J Wassell↗

TOWARD A METHOD FOR SCALING HUMAN BODY MODELS IN AN IMU-BASED WORKFLOW

BACKGROUND Scaled biomechanical models can more accurately inform crew health decisions when tailored to the wide range of astronaut sizes. One component to improve scaling of existing models to better represent each unique astronaut’s size is the individual length scaling of limbs. Traditionally, these lengths are determined by motion capture or manual measurement. A new method is herein proposed for length scaling which can be done by measuring linear and angular accelerations at a desired point during isolated motion around a point of rotation, then calculating the distance between the desired point and point of rotation. When an Inertial Measurement Unit (IMU) device is placed at the distal point of a limb, the isolated motion is about that limb’s proximal joint. For example, to measure forearm length, an IMU is placed at the wrist, the point of rotation is at the elbow, and the isolated motion is forearm flexion and extension. These calculated lengths are then used to scale models to each unique astronaut’s size, thereby improving the applicability of the model. This method of scaling limb segments can be used for any limb that has an easily defined proximal joint for the limb to rotate around including hands, arms, legs, feet. Utilizing IMUs for data collection also provides the synergistic ability to record data without a dedicated space in a room with many cameras, therefore reducing the data collection footprint, or record data where optical motion capture is not possible, such as inside a spacesuit. METHODS AND RESULTS To test this method, upper body data collection was performed with 5 Xsens DOT IMUs on a single subject. IMUs consist of an accelerometer, a gyroscope, and a magnetometer which collect linear acceleration, angular velocity, and magnetic fluctuations, respectively. Before any ground-based laboratory collection, the magnetic fluctuations are used to correct the heading of the IMU in space relative to the Earth’s magnetic field. The direct measurement of angular velocity is integrated to calculate angular acceleration. Then the linear acceleration ( a ) and angular acceleration (α) are solved using r = at/α to calculate the radius, which in this case is the distance between the IMU and the point of rotation (i.e., segment length). The IMU must be placed at the most distal point of the limb being measured (i.e., ankle if measuring lower leg length) and the test plan must consist of an isolated motion about that limb’s proximal joint (i.e., knee flexion and extension if measuring lower leg length). The distances (radii) calculated at every time interval were filtered (bandpass filter keeping 5th-90th percentile data) to eliminate outliers and spurious data that occur when the isolated motion was stopped or nearly stopped. The remaining distances were averaged, resulting in the calculated limb length. Scaling factors were then computed by dividing the calculated limb length by the unscaled model’s length. These scale factors are plugged into the Scale Tool in OpenSim [1,2] to apply the scaling to the OpenSim Full Body Rajagopal Model [3,4]. Manual measurements of limb lengths were taken before data collection started and used for comparing against the calculated lengths. The Anthropometric Survey of US Army Personnel (ANSUR II) [5] was also used as a third source of reference for limb length measurements. The following measurements were retrieved from the subject before data collection: 34.5 cm from L1 to C7 (thorax), 25.7 cm from C7 Joint Center (JC) to head vertex (neck and head), 36.3 cm from shoulder JC to elbow JC (humerus), 29.5 cm from elbow JC to wrist JC (forearm), and 16.2 cm from clavicle to acromion (clavicle). Of those five, forearm and humerus lengths were calculated using this proposed method to obtain preliminary results. The forearm length after filtering and averaging was calculated to be 37.6 cm. This is a 28% overestimation from the measured forearm length (29.5 cm). The humerus length after filtering and averaging was calculated to be 47.8 cm. This is a 31% difference from the measured subject length (36.3 cm). Sources of error include imperfect isolated motion (method currently expects that motion should be perfectly circular in a 2D plane, include no rotation of the IMU, and be relatively smooth; a more secure IMU attachment method will help), unrefined filter techniques (removed highest and lowest values with 20% high and low pass filters and no smoothing filters), arbitrary removal of stopped or near stopped data (kept data for only a short range before and after the angular velocity peaking), and a more representative method for removing gravitational acceleration is needed (current method is to zero all accelerations against a baseline taken just before the isolated motion which does not account for the gravitational acceleration changed due to IMU rotation during movement). Addressing these error sources will improve the accuracy of the limb length calculation. Next steps include creating a method for whole-body scaling estimation using individual limb scale factors. Continued pursuit of these techniques is expected to enable acquiring anthropometric information using only IMUs in real-time.

E. K. Marecki↗

A Summary of Test Results from a NASA Lift + Cruise eVTOL Crash Test

On November 9, 2022, the National Aeronautics and Space Administration (NASA) conducted a full-scale crash test of the NASA Lift+Cruise (LPC) reference vehicle at the NASA Langley Research Center Landing and Impact Research Facility (LandIR) under combined vertical and horizontal impact conditions to simulate a severe but survivable crash. The LPC test article is a carbon-composite skin/frame structure design, developed and fabricated for the cabin section only. The test utilized various configurations of seats and Anthropomorphic Test Devices (ATDs, a.k.a. crash test dummies) intended to encompass a variety of occupant conditions. In addition, an in-house developed energy absorbing subfloor was utilized for the evaluation of load attenuation. Overhead mass was simulated using attached lifting hardware and other systems were simulated using ballast mass. The test article impacted the ground with velocities of 38.1 ft/s horizontal and 31.4 ft/s vertical. During the first approximately 38 milliseconds (ms), the cabin section experienced a large amount of acceleration on the belly which was attenuated by the subfloor structures and seats. Over the next approximately 160 ms, the test article experienced failure in the a-, b- and c-pillars, leading to a partial collapse of the overhead structure. Test data was collected on the belly, floors, seats, overhead mass, and tail. In addition, there was high speed full-field digital image correlation analysis data collected on the port side skin surface. Collected ATD data showed that the ATDs seated in the energy absorbing seats experienced loads at limits below the those in current regulations. Even without an energy absorbing seat, the energy absorbing subfloors crushed as intended, and limited the load on the large 95 th percentile ATD to 10% over suggested limits. The collapse of the roof did affect the 95 th percentile ATD, which showed high neck loading values due to head contact, whereas survivable volume was maintained for the other ATDs. While the energy absorbing subfloor and energy absorbing seats both contributed to occupant load attenuation, further optimization is suggested to increase their robustness.

evtol↗

A Summary of Test Results from a NASA Lift + Cruise eVTOL Crash Test

On November 9, 2022, the National Aeronautics and Space Administration (NASA) conducted a full-scale crash test of the NASA Lift+Cruise (LPC) reference vehicle at the NASA Langley Research Center Landing and Impact Research Facility (LandIR) under combined vertical and horizontal impact conditions to simulate a severe but survivable crash. The LPC test article is a carbon-composite skin/frame structure design, developed and fabricated for the cabin section only. The test utilized various configurations of seats and Anthropomorphic Test Devices (ATDs, a.k.a. crash test dummies) intended to encompass a variety of occupant conditions. In addition, an in-house developed energy absorbing subfloor was utilized for the evaluation of load attenuation. Overhead mass was simulated using attached lifting hardware and other systems were simulated using ballast mass. The test article impacted the ground with velocities of 38.1 ft/s horizontal and 31.4 ft/s vertical. During the first approximately 38 milliseconds (ms), the cabin section experienced a large amount of acceleration on the belly which was attenuated by the subfloor structures and seats. Over the next approximately 160 ms, the test article experienced failure in the a-, b- and c-pillars, leading to a partial collapse of the overhead structure. Test data was collected on the belly, floors, seats, overhead mass, and tail. In addition, there was high speed full-field digital image correlation analysis data collected on the port side skin surface. Collected ATD data showed that the ATDs seated in the energy absorbing seats experienced loads at limits below the those in current regulations. Even without an energy absorbing seat, the energy absorbing subfloors crushed as intended, and limited the load on the large 95 th percentile ATD to 10% over suggested limits. The collapse of the roof did affect the 95 th percentile ATD, which showed high neck loading values due to head contact, whereas survivable volume was maintained for the other ATDs. While the energy absorbing subfloor and energy absorbing seats both contributed to occupant load attenuation, further optimization is suggested to increase their robustness.

evtol↗