Universal fieldable assay with unassisted visual detection

A universal detection system based on allosteric aptamers, signal amplification cascade, and eye-detectable phrase transition. A broadly applicable homogeneous detection system is provided. It utilizes components of the blood coagulation cascade in the presence of polystyrene microspheres (MS) as a signal amplifier. Russell's viper venom factor X activator (RVV-X) triggers the cascade, which results in an eye-visible phase transition--precipitation of MS bound to clotted fibrin. An allosteric RNA aptamer, RNA132, with affinity for RVV-X and human vascular endothelial growth factor (VEGF.sub.165) was created. RNA132 inhibits enzymatic activity of RVV-X. The effector molecule, VEGF.sub.165, reverses the inhibitory activity of RNA132 on RVV-X and restores its enzymatic activity, thus triggering the cascade and enabling the phase transition. Similar results were obtained for another allosteric aptamer modulated by a protein tyrosine phosphatase. The assay is instrumentation-free for both processing and readout.

Chelyapov, Nicolas↗

Surface-Enhanced Raman Scattering Using Silica Whispering-Gallery Mode Resonators

The motivation of this work was to have robust spectroscopic sensors for sensitive detection and chemical analysis of organic and molecular compounds. The solution is to use silica sphere optical resonators to provide surface-enhanced spectroscopic signal. Whispering-gallery mode (WGM) resonators made from silica microspheres were used for surface-enhanced Raman scattering (SERS) without coupling to a plasmonic mechanism. Large Raman signal enhancement is observed by exclusively using 5.08-micron silica spheres with 785-nm laser excitation. The advantage of this non-plasmonic approach is that the active substrate is chemically inert silica, thermally stable, and relatively simple to fabricate. The Raman signal enhancement is broadly applicable to a wide range of molecular functional groups including aliphatic hydrocarbons, siloxanes, and esters. Applications include trace organic analysis, particularly for in situ planetary instruments that require robust sensors with consistent response.

Anderson, Mark S.↗

Methods and apparatus for microwave tissue welding for wound closure

Methods and apparatus for joining biological tissue together are provided. In at least one specific embodiment, a method for joining biological tissue together can include applying a biological solder on a wound. A barrier layer can be disposed on the biological solder. An antenna can be located in proximate spatial relationship to the barrier layer. An impedance of the antenna can be matched to an impedance of the wound. Microwaves from a signal generator can be transmitted through the antenna to weld two or more biological tissue pieces of the wound together. A power of the microwaves can be adjusted by a control circuit disposed between the antenna and the signal generator. The heating profile within the tissue may be adjusted and controlled by the placement of metallic microspheres in or around the wound.

Arndt, G. Dickey↗

Investigating the Present Day Cosmic Dust Flux at the Earth's Surface: Initial Results from the Kwajalein Micrometeorite Collection

Examination of impact craters on the Long Duration Exposure Facility satellite indicate a present day micrometeoroid flux of approx. 30,000 tonnes [1 after 2]. But what portion of this material arrives at the Earth's surface as micrometeorites? Studies of available micrometeorite collections from deep sea sediments [e.g. 3], Greenland blue ice [e.g. 4] and the South Pole water well [e.g. 1] may be complicated by terrestrial weathering and, in some cases, collection bias (magnetic separation for deep sea sediments) and poorly constrained ages. We have recently set up a micrometeorite collection station on Kwajalein Island in the Republic of the Marshall Islands in the Pacific Ocean, using high volume air samplers to collect particles directly from the atmosphere. By collecting in this way, the terrestrial age of the particles is known, the weathering they experience is minimal, and we are able to constrain particle arrival times. Collecting at this location also exploits the considerably reduced anthropogenic background [5]. Method: High volume air samplers were installed on top of the two-story airport building on Kwajalein. These were fitted with polycarbonate membrane filters with 5μm diameter perforations. The flow rates were set to 0.5m3/min, and filters were changed once a week. After collection, filters were washed to remove salt and concentrate particles [see 5] in preparation for analysis by SEM. Results and Discussion: A selection of filters have been prepared and surveyed. Due to their ease of identification our initial investigations have focused on particles resembling cosmic spherules. The spheres can be divided into three main groups: 1. Silicate spherules rich in Al, Ca, K and Na (to varying degrees), 2. Silicate spherules rich in Mg and Fe and 3. Fe-rich spherules. Group 1 spherules are often vesiculated and can occur as aggregates. They are similar in appearance and composition to volcanic microspheres [e.g. 6] and are thus likely terrestrial in origin (volcanic). Those of groups 2 and 3, however, typically exhibit quenched surface textures consistent with cosmic spherules. Initial results suggest there is significant variation in the abundance of these groups from filter to filter. Work is ongoing to fully characterize these spherules and to constrain their flux with time.

Wozniakiewicz, P. J.↗

Scattering Properties of Lunar Dust Analogs

A number of space missions are planned to explore the lunar exosphere which may contain a small population of dust particles. The objective of this paper is to present preliminary results from scattering experiments on a suspension of lunar simulants to support one such mission. The intensity of the light scattered from a lunar simulant is measured with a commercial version of the spectrometer used in the forthcoming LADEE mission. Physical properties of the lunar simulant are described along with two similarly-sized reference microspheres. We confirm that micron-sized particles tend to form agglomerates rather than remaining isolated entities and that certain general characteristic of the target particles can be predicted from intensity measurements alone. These results can be used directly to assess general features of the lunar exosphere from LADEE instrument data. Further analysis of particle properties from such remote sensing data will require measurements of polarization signatures.

Lunar dust↗

Particulate Removal Using a CO2 Composite Spray Cleaning System

The Planetary Protection surface cleanliness requirements for potential Mars Sample Return hardware that would come in contact with Martian samples may be stricter than previous missions. The Jet Propulsion Laboratory has developed a new technology that will enable us to remove sub-micron size particles from critical hardware surfaces. A hand-held CO2 composite cleaning system was tested to verify its cleaning capabilities. This convenient, portable device can be used in cleanrooms for cleaning after rework or during spacecraft integration and assembly. It is environmentally safe and easy to use. This cleaning concept has the potential to be further developed into a robotic cleaning device on a Mars Lander to be used to clean sample acquisition or sample handling devices in situ. Contaminants of known sizes and concentrations, such as fluorescent microspheres and spores were deposited on common spacecraft material surfaces. The cleaning efficiency results will be presented and discussed.

carbon dioxide↗

Research and Development History of Glass Bubbles Bulk-Fill Thermal Insulation Systems for Large-Scale Cryogenic Liquid Hydrogen Storage Tanks

Based on the published literature record, this document provides an overview of the research and development of glass bubbles bulk-fill thermal insulation systems for cryogenic equipment in general and, in particular, for large-scale cryogenic liquid hydrogen (LH2) storage spheres. Glass bubbles (also known as hollow glass microspheres) are used in place of perlite powder which began use in double-wall cryogenic tanks in the 1930s. Included in this overview is a historical summary, a development timeline, a selected publications list, and the key technical points from those publications.

Cryogenic storage tanks↗

Improving Tracer Particle Surface Properties for Wind Tunnel Research

The surface properties of micron size polystyrene latex microspheres (PSLs) modified with quaternary alkylammonium (QA) surfactants were investigated, with a focus on the relationship between surface chemistry and adhesion. These investigations were motivated by the need to develop non-fouling tracer particles for wind tunnel studies. The goals were to relate the work of adhesion between particles and substrates to the type and amount of QA modifier in order to optimize the performance of PSL tracers. Surfactant-free emulsion polymerization (SFEP) can produce PSLs for wind tunnel tracers. Covalentlybound charged groups (derived from the initiator) stabilize PSL surfaces in water. This work used PSLs with anionic surface groups. Previous studies indicated that surface-bound charged groups on PSLs have a significant impact on their interfacial energy. Modifying charged surface groups therefore offers a method to modulate PSL interfacial properties. In this work, PSLs and films were modified by adsorption of QA surfactants.

Schmitz, Russell C.↗

Vacuum Pump-Down of the Annular Insulation Space for Large Field-Erected Liquid Hydrogen Storage Tanks

Insulation systems are critical to liquid hydrogen storage tank performance. Tanks in the capacity range of 100 to 1,000 m 3 are typically shop built and designed with high-vacuum (HV) multi-layer insulation (MLI), whereas storage vessels larger than 1,000 m 3 are typically field-erected and supplied with bulk fill insulation working at moderate vacuum (MV) levels (1-100 millitorr). For large, field-erected vessels, two types of bulk fill insulation typically used: perlite and hollow glass microspheres (glass bubbles). Selection of either material is driven by a tradeoff between CAPEX and OPEX, such as the material and construction cost versus operating thermal performance and maintenance. In either case, the vacuum level needed to achieve optimum performance is likely to drive the field testing and commissioning portion of the construction schedule. A primary goal of this paper is to present practical experience and data for warm vacuum pressure (WVP) and cold vacuum pressure (CVP) levels. Recommended WVP levels needed prior to cooldown consider both perlite powder and glass bubbles. Pumping time expected to achieve target vacuum levels, considering a variety of factors, is also discussed. Recommendations for a standard practice in vacuum-insulated tank commissioning are based on historical NASA data, and those collected during recent projects.

A M Swanger↗

Resilient, untethered soft robot

A pneumatically powered, fully untethered mobile soft robot is described. Composites consisting of silicone elastomer, polyaramid fabric, and hollow glass microspheres were used to fabricate a sufficiently large soft robot to carry the miniature air compressors, battery, valves, and controller needed for autonomous operation. Fabrication techniques were developed to mold a 0.65 meter long soft body with modified Pneumatic network actuators capable of operating at the elevated pressures (up to 138 kPa) required to actuate the legs of the robot and hold payloads of up to 8 kg. The soft robot is safe to handle, and its silicone body is innately resilient to a variety of adverse environmental conditions including snow, puddles of water, direct (albeit limited) exposure to flames, and the crushing force of being run over by an automobile.

42 ENGINEERING↗

Method for printing low-density polymer structures

A method of forming a low-density three-dimensional article is provided. The method includes printing a low-density composition on a substrate to form at least one layer comprising the low-density composition. The low-density composition includes a (P) polymer component and (M) a microsphere component in a ratio by volume (P):(M). The method also includes selectively controlling a density of the low-density composition during printing to give the at least one layer on the substrate. Selectively controlling the density of the low-density composition includes varying the ratio (P):(M) during printing. The method further includes repeating the printing and selectively controlling the density of the low-density composition to form additional layer(s), thereby forming the low-density three-dimensional article. A low-density three-dimensional article prepared in accordance with the method is also provided.

Kunc, Vlastimil↗

Investigating the AGN-201M research reactor's unique dominance ratio

The AGN-201M reactor is a small, thermal spectrum reactor located at the University of New Mexico (UNM). It is moderated by polyethylene, reflected by graphite, with fuel comprised of uranium microspheres embedded in polyethylene plates that are separated by an aluminum baffle. The dominance ratio of a multiplying system is the ratio of the first higher-mode eigenvalue to the fundamental, k{sub 1}/k{sub 0}. It is a key parameter in characterizing the rate of convergence, analyzing system stability, and determining how tightly coupled the system's neutron fission is. The purpose of this paper is to investigate the system's unusually low dominance ratio of 0.632. This investigation varied the reactor's physical parameters, such as the fuel geometry, fuel density, and reflector thickness, and examined their impact on the reactor's dominance ratio. Additionally, this study examined neutronically similar systems in hopes of identifying common causes for systems with low dominance ratios. The reason why the dominance ratio of the reactor is small compared to larger thermal reactors was determined to be because of its significantly smaller geometry and the composition of the fuel plates. The reflector's effect on the dominance ratio is small in comparison to the other factors, but was found to have a non-zero effect. Furthermore, the AGN-201M was found to have a significantly lower dominance ratio than systems in which it shares a very high (c{sub k} >95%) degree of neutronic similarity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Internal-Gelation Production of Uranium Oxide Sol-Gel Particles for Forensic Applications

The purpose of this project was to develop and demonstrate a novel method for the production of uranium oxide microsphere particles with tunable chemical compositions via a sol-gel process using a 3D-printer setup. These particles can serve several purposes in research and development as a forensic training tool or as standard reference materials. A key component of the project was to demonstrate the ability to control physical and chemical parameters of the particles created. First, we demonstrated the ability to employ an internal gelation sol-gel process to create individual uranium oxide particles. The particles were successfully dispensed using a unique 3D-printing setup onto a substrate to react and then were collected and thermally processed. A series of temperatures for the annealing process was tested on individual samples to investigate the effect on the sol-gel chemical composition and physical integrity. Next, we demonstrated the ability to control matrix composition of the particles by separately incorporating fission product isotopes as well as Np-237 into the sol-gel solution. It was shown by gamma-ray spectroscopy that these matrix elements were successfully retained during the gelation process. We studied the retention of the elements across a series of annealing temperatures. Additionally, we demonstrated the ability to quantitatively control the isotopic composition of the particles by altering the U-237/U-238 ratio to a controlled value. Finally, X-ray diffraction analysis (XRD) was used to investigate the oxidation state of the sol-gel after annealing at different temperatures.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Trichloroethylene replacements for the cleaning of silicone oil used in the internal gelation process

Silicone oil continues to be used as a gelation medium for internal gelation process. Typically, the silicone oil has been removed from the gel spheres using trichloroethylene (TCE) washes. However, TCE is no longer a viable option for large-scale operations because of environmental issues, health concerns, and disposal costs. Furthermore, during the development of a large gelation system at the Y-12 National Security Complex, two new TCE wash replacements were identified. NuSolv SOR-C and FluoSolv WS were used in a number of uranium runs and found to effectively remove silicone oil. NuSolv SOR-C was determined to be the best option.

36 MATERIALS SCIENCE↗

Outcomes After Transarterial Embolization of Neuroendocrine Tumor Liver Metastases Using Spherical Particles of Different Sizes

Purpose: To evaluate initial response and overall survival of neuroendocrine tumor (NET) liver metastases initially treated with transarterial embolization (TAE) using spherical particles of different sizes. Methods: A single-institution retrospective review was performed of 160 patients with NET liver metastases initially treated with TAE using < 100 µm (n = 77) or only ≥ 100 µm (n = 83) spherical particles. For each patient, we evaluated: initial response by mRECIST, time to progression, overall survival, complications, primary site, tumor grade and degree of differentiation, volume of liver disease, extrahepatic disease, NET-related symptoms, comorbidities, Child–Pugh score, performance status, lobar versus selective embolization, and arteriovenous shunting. Results: Initial response was higher for TAE using particles < 100 versus TAE using only particles ≥ 100 μm (64 vs 42%, p = 0.007). Multivariate logistic regression showed that use of particles < 100 μm and liver < 50% replaced with tumor were independent predictors of a better initial response rate. There was no difference in major or minor complications between the two particle size groups. Median overall survival after TAE was 55 months for well- to moderately differentiated NET and 13 months for poorly differentiated or undifferentiated NET. There was no significant difference in survival between TAE patients treated with < 100 versus only ≥ 100-μm particles. Conclusion: NET patients treated with TAE using particles < 100 μm had better initial response, but the same overall survival, compared to TAE using only particles ≥ 100 μm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Relationship Between Gelatin Sponge Preparation Methods and the Incidence of Intrauterine Synechia Following Uterine Artery Embolization for Postpartum Hemorrhage

Purpose: To evaluate the relationship between gelatin sponge preparation methods and the incidence of intrauterine synechia following uterine artery embolization (UAE) for postpartum hemorrhage (PPH). Materials and Methods: In a retrospective monocentric study, we used data from 20 consecutive UAE procedures (19 patients) for PPH, performed in 2007–2016, in which gelatin sponge had been used. The gelatin sponge was processed either into a slurry by pumping it back and forth about 10 times through two syringes connected to a three-way stopcock or into pledgets using a scalpel and small scissors to obtain pieces approximately 2 × 2 × 2 mm in size. Patient information was obtained from medical records, and the data were compared between patients treated with the slurry (n = 7) or pledgets (n = 13) forms. Due to the lack of follow-up data and hysterectomy after UAE, the sample size was 6 and 12 because 1 patient with 2 procedures was excluded. Results: The rate of intrauterine synechia was significantly higher in the slurry group (5/6, 83.3%) than that in the pledgets group (0/12, 0%; P < 0.001). In contrast, there were no significant differences in population characteristics, such as the incidence of placenta accreta, non-placental diseases, and severity of shock (DIC score, shock index, or blood loss) between the groups. Conclusions: Although non-randomization and small sample size were the two main limitations, our observations suggest that UAE using gelatin sponge slurry may be associated with a high incidence of intrauterine synechia compared to UAE using pledgets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uterine Artery Embolization in Women with Symptomatic Cervical Leiomyomata: Efficacy and Safety

Purpose: To perform an evaluation on safety and efficacy of uterine artery embolization (UAE) in the patients with symptomatic cervical leiomyomata. Methods: Patients with symptomatic cervical leiomyomata who underwent UAE in one specialized hospital were retrospectively analyzed, both clinically and with MR imaging. The 3-month outcomes were assessed with MR imaging and a validated questionnaire. Long-term follow-up was assessed by direct contact or file review. To determine the efficacy of UAE for cervical leiomyomata, the primary objective was to assess the clinical outcome with the UFS-QOL questionnaire, containing the health-related quality of life (HRQOL) and symptom severity score (SSS). To assess safety, the secondary objective included leiomyomata volume reduction, the infarction/complication rate and secondary interventions were needed. Results: Between 2006 and 2017, eight of 1180 patients underwent UAE and were eligible for inclusion. All embolizations were technically successful (n = 8). At 3 months, all patients showed cervical leiomyomata volume reduction with a median reduction of 41.5% (38.8 cm{sup 3}) compared to baseline (p = 0.012). No complications occurred. At a median follow-up of 3 months (range 1–7, n = 7), the HRQOL and SSS improved with a median difference of 13 points (range − 5 to 60, p = 0.063) and − 13 points (range − 79 to 3, p = 0.046), respectively. Long-term follow-up showed two secondary interventions (median of 43.5 months). Six patients reported no symptom recurrence. Conclusion: UAE in women with symptomatic cervical leiomyomata is effective and safe with significant improvement in symptoms and quality of life. UAE is a valuable option for women seeking a non-surgical solution.