Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

Regulatory and ratemaking approaches to mitigate financial impacts of net-metered PV on utilities and ratepayers

The financial interests of U.S. utilities are poorly aligned with customer-sited solar photovoltaics (PV) under traditional regulation. Customer-sited PV, especially under a net-metering arrangement, may result in revenue erosion and lost earnings opportunities for utility shareholders as well as increases in average retail rates for utility ratepayers. Regulators are considering alternative regulatory and ratemaking approaches to mitigate these financial impacts. We performed here a scoping analysis using a financial model to quantify the efficacy of mitigation approaches in reducing financial impacts of customer-sited PV on utility shareholders and ratepayers. We find that impacts can be mitigated through various incremental changes to utility regulatory and business models, though the efficacy varies considerably depending on design and particular utility circumstances. Based on this analysis, we discuss tradeoffs policymakers should consider, which ultimately might need to be resolved within broader policy contexts.

14 SOLAR ENERGY↗

Drug distribution transients in solution and suspension-based pressurised metered dose inhaler sprays

This work introduces in situ time-resolved drug mass fraction measurements in pressurised metered dose inhaler (PMDI) sprays, using a novel combination of synchrotron X-ray fluorescence and scattering. Equivalent suspension and solution formulations of ipratropium bromide in HFA-134a propellant were considered. Measurements were made both inside the expansion chamber behind the nozzle orifice, and in the first few millimeters of the spray where droplet and particle formation occur. We viewed a consistent spike in drug mass fraction at the beginning of the spray when the first fluid exits the nozzle orifice. Approximately 20% of the total delivered dose exits the nozzle in the first 0.1 s of the spray. The drug mass fraction in the droplets immediately upon exiting the nozzle peaked at approximately 50% of the canister mass fraction, asymptoting to approximately 20% of the canister concentration. The result is due to a change in the drug mass fraction inside the droplets, rather than changes in droplet size or distribution. The transient was found to originate inside the expansion chamber. We propose that this effect may be a major contributor to low delivery efficiency in PMDIs, and have important implications for oropharyngeal deposition and inhalation technique. This reflects the importance of expansion chamber and nozzle design on the structure of PMDI sprays, and indicates areas of focus that may lead to improvement in drug delivery outcomes.

42 ENGINEERING↗

Prospective Study Validating Inter- and Intraobserver Variability of Tissue Compliance Meter in Breast Tissue of Healthy Volunteers: Potential Implications for Patients With Radiation-Induced Fibrosis of the Breast

Purpose: Accurate detection of radiation-induced fibrosis (RIF) is crucial in management of breast cancer survivors. Tissue compliance meter (TCM) has been validated in musculature. We validate TCM in healthy breast tissue with respect to interobserver and intraobserver variability before applying it in RIF. Methods and Materials: Three medical professionals obtained three consecutive TCM measurements in each of the four quadrants of the right and left breasts of 40 women with no breast disease or surgical intervention. The intraclass correlation coefficient (ICC) assessed interobserver variability. The paired t test and Pearson correlation coefficient (r) were used to assess intraobserver variability within each rater. Results: The median age was 45 years (range, 24-68 years). The median bra size was 35C (range, 32A-40DD). Of the participants, 27 were white (67%), 4 black (10%), 5 Asian (13%), and 4 Hispanic (10%). ICCs indicated excellent interrater reliability (low interobserver variability) among the three raters, by breast and quadrant (all ICC {>=}0.99). The paired t test and Pearson correlation coefficient both indicated low intraobserver variability within each rater (right vs. left breast), stratified by quadrant (all r{>=} 0.94, p < 0.0001). Conclusions: The interobserver and intraobserver variability is small using TCM in healthy mammary tissue. We are now embarking on a prospective study using TCM in women with breast cancer at risk of developing RIF that may guide early detection, timely therapeutic intervention, and assessment of success of therapy for RIF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Randomized Trial of Pentoxifylline and Vitamin E vs Standard Follow-up After Breast Irradiation to Prevent Breast Fibrosis, Evaluated by Tissue Compliance Meter

Purpose: To conduct a randomized clinical trial to determine whether the combination of pentoxifylline (PTX) and vitamin E given for 6 months after breast/chest wall irradiation effectively prevents radiation-induced fibrosis (RIF). Methods and Materials: Fifty-three breast cancer patients with localized disease were enrolled and randomized to treatment with oral PTX 400 mg 3 times daily and oral vitamin E 400 IU daily for 6 months after radiation (n=26), or standard follow up (n=27). Tissue compliance meter (TCM) measurements were obtained at 18 months to compare tissue compliance in the irradiated and untreated breast/chest wall in treated subjects and controls. Measurements were obtained at 2 mirror image sites on each breast/chest wall, and the average difference in tissue compliance was scored. Differences in TCM measurements were compared using a t test. Subjects were followed a minimum of 2 years for local recurrence, disease-free survival, and overall survival. Results: The mean difference in TCM measurements in the 2 groups was 0.88 mm, median of 1.00 mm (treated) and 2.10 mm, median of 2.4 mm (untreated). The difference between the 2 groups was significant (P=.0478). Overall survival (100% treated, 90.6% controls at 5 years) and disease-free survival (96.2% treated, 86.8% controls at 5 years) were not significantly different in the 2 groups. Conclusions: This study of postirradiation breast cancer patients treated with PTX/vitamin E or standard follow-up indicated a significant difference in radiation-induced fibrosis as measured by TCM. There was no observed impact on local control or survival within the first 2 years of follow-up. The treatment was safe and well tolerated. Pentoxifylline/vitamin E may be clinically useful in preventing fibrosis after radiation in high-risk patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser ablation of high-loading Li-ion battery electrodes improves accessible capacity and cycle life for Behind-the-Meter Storage

Adoption of Behind-the-Meter Storage (BTMS) requires design of batteries that enable high safety, long cycle life, and low cost at the system level. Pairing Li 4 Ti 5 O 12 (LTO) with LiMn 2 O 4 (LMO) achieves targets related to safety and cycle life, but these materials' low energy densities contribute to higher cost at the system scale. Increasing electrode loading is a simple approach to improve energy density, but comes with a trade-off in electrode utilization due to long, tortuous Li + diffusion pathways. Here, laser ablation is used to microstructure (pattern) high-loading electrodes to enhance electrode performance through improved Li + diffusion pathways. Four cell types, comprising combinations of standard or patterned anode and cathode, were prepared to evaluate the effects of laser ablation at each electrode. A rate test shows that patterning electrodes enhances active material utilization at ≳1C rates. Patterning the cathode yields the most benefit, as cells with a patterned cathode demonstrate a ~20% higher accessible capacity than those without at 1.4C. Additionally, 1C capacity retention of cells with patterned cathode (91% through 3000 cycles) is significantly improved over cells with only the anode patterned (64%) and non-patterned electrodes (50%). Characterization of post-mortem cells before and after refreshing their electrolyte suggests that 1C capacity retention is improved by mitigation of electrode "dry-out". We hypothesize that the microstructure acts as a reservoir of additional electrolyte, or a path for gas to escape, so that active material remains wetted throughout long-term cycling, and/or the microstructure may reduce localized, gas-forming overpotentials in the high-loading electrode.

25 ENERGY STORAGE↗

Customer bill impacts of energy efficiency and net-metered photovoltaic system investments

We report utility regulators and policymakers are concerned about potential increases in retail rates driven by energy efficiency (EE) programs and distributed solar photovoltaic (PV) systems, which may adversely affect utility customers that do not invest in these technologies (i.e., non-participants) and more so than those that do (i.e., participants). We assess customer bill impacts of illustrative EE programs and net-metered PV systems for a prototypical northeast utility. We find that the timing of customer EE or PV investments matters and that modest energy savings may fail to yield financial benefits sufficient to offset concomitant increases in retail rates.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Standoff trace explosives vapor detection at meter distances

Vapor detection is a noncontact sampling method, which is a less invasive means of explosives screening than physical swiping. Explosive vapor detection is a challenge due to the low levels of vapors available for detection. This study demonstrates that the parts-per-quadrillion sensitivity of atmospheric flow tube-mass spectrometry (AFT-MS) combined with a high-volume air sampler enables standoff detection of trace explosives vapor at distances of centimeters to meters. Standoff detection of explosives vapor was possible both upstream and downstream of the vapor source relative to room air currents. RDX vapor from a saturated source was detected at up to 2.5 m. Vapors from RDX residue and nitroglycerin residue were detected at distances up to 0.5 m. The sampling can be optimized by accounting for air movement in the room or environment, which could further extend standoff detection distances. In conclusion, using AFT-MS with a high-volume sampler could also be effective for standoff vapor detection of drugs and additional chemical threats and could be useful for security screening applications such as at mail facilities, border crossings, and security checkpoints.

47 OTHER INSTRUMENTATION↗

Incorporating Diurnal and Meter-Scale Variations of Ambient CO 2 Concentrations in Development of Direct Air Capture Technologies

To be implemented on climate-relevant scales, direct air capture of CO 2 (DAC) will require large capital-intensive facilities and careful attention to cost minimization. In making decisions among potential sites for DAC facilities, all of the factors that will impact process cost and efficiency should be considered. In this paper we focus on a factor that has previously received little attention in the DAC community, namely variations in atmospheric conditions on hourly time scales and length scales of meters. We present data curated from extensive previous studies of biosphere-atmosphere fluxes with observations of CO 2 concentration, temperature, and relative humidity (RH) with hourly resolution from many sites in North America. These include locations where typical diurnal variations in CO 2 concentration during summer months exceeds 150 ppm. These variations are larger than the seasonal variations that exist between averaged CO 2 concentrations in winter and summer, and they are highly correlated with diurnal variations in temperature and RH. Diurnal variations are dependent on the height above ground at which CO 2 concentrations are measured, with smaller variations existing at heights of 10 m or more than at ground level. We illustrate the potential implications of these short-term variations for the operation and optimization of a DAC process with process-level calculations for a specific adsorption-based process using amine-rich adsorbents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Seismic Ambient Noise Analyses Reveal Changing Temperature and Water Signals to 10s of Meters Depth in the Critical Zone

The critical zone sustains terrestrial life, but we have few tools to explore it efficiently beyond the first few meters of the subsurface. Using analyses of high-frequency ambient seismic noise from densely spaced seismometers deployed in the forested Shale Hills subcatchment of the Susquehanna Shale Hills Critical Zone Observatory (SSHCZO), we show that temporal changes in seismic velocities at depths from ~1 m to tens of m can be detected. Furthermore, these changes are driven by variations at the land surface. The Moving-Window Cross-Spectral (MWCS) method was employed to measure seismic-velocity changes in coda waves at hourly resolution in 10 different frequency bands. We observed a diurnal signal, a seasonal signal, and a meteorological-event-based signal. These signals were compared to time-series measurements of precipitation, well water levels, soil moisture, soil temperature, air temperature, latent heat flux, and air pressure in the heavily instrumented catchment. Most of the velocity changes can be explained by variations in temperature that result in thermoelastic strains that propagate to depth. But some double minima in seismic velocity time-series observed after large rain events were attributed in part to the effects of water infiltration. These results show that high-frequency ambient noise data may in some locations be used to detect changes in the critical zone from ~1 to ~100 m or greater depth with hourly resolution. But interpretation of such data requires multiple environmental data sets to deconvolve the complex interrelationships among thermoelastic and hydrological effects in the subsurface critical zone.

54 ENVIRONMENTAL SCIENCES↗

Theory of an Automatic Seepage Meter and Ramifications for Applications

A new approach for measuring fluxes across surface water—groundwater interfaces was recently proposed. The Automatic Seepage Meter (ASM) is equipped with a precise water level sensor and digital memory that analyzes water level time series in a vertical tube inserted into a streambed. The ability to infer flux values with high temporal resolution relies on an accurate interpretation of water level dynamics inside the tube. Here, we reduce the three-dimensional hydrodynamic problem that describes the ASM water level in a variety of field conditions to a single ordinary differential equation. This novel general analytical solution for estimating ASM responses is more comprehensive and flexible than previous approaches and is applicable to the entire range of field conditions, including steady or transient stream stages, evaporation, rainfall, and noise. For example, our analysis determines the timing of the nonmonotonic ASM response to a monotonic linear stream stage variation and explains previously used empirical parabolic approximation for estimating fluxes. We present algorithms for simultaneous inference of vertical interface flux and hydraulic conductivity values together with an example code. We quantify how the accuracy of parameter estimation depends on test duration and noise amplitude and propose how our analysis can be used to optimize field test protocols. On this basis, changing the ASM geometry by increasing the radius and decreasing tube insertion depth may enable ASM field test protocols that estimate interface flux and hydraulic conductivity faster while maintaining desired accuracy. Potential applications of joint parameter estimation are suggested.

47 OTHER INSTRUMENTATION↗

Cubic-meter scale laboratory fault re-activation experiments to improve the understanding of induced seismicity risks

Abstract To understand fluid induced seismicity, we have designed a large-scale laboratory experiment consisting of a one-cubic-meter sandstone with an artificial fault cut and fluid-injection boreholes. The sandstone block is assembled in a true triaxial loading frame and equipped with 38 piezoelectric sensors to locate and characterise acoustic emission events. The differential stress on the artificial fault is increased in stages to bring it towards a critically stressed state. After each stage of differential stress increase, fluids are injected at low pressures through boreholes to test the potential of fault re-activation. In addition, a high-pressure injection was conducted that created a hydraulic fracture from the injection borehole towards the artificial fault. The newly generated fluid pathway resulted in an activation of the complete block through a stick–slip movement. We compare acoustic emission measurements from the laboratory experiment with seismicity observations from the field-scale CO 2 injection at Decatur, Illinois, U.S., and conclude that the existence of fluid pathways plays a decisive role for the potential of induced seismicity.

47 OTHER INSTRUMENTATION↗

Interaction of soft x-ray laser pulse radiation with aluminum surface: Nano-meter size surface modification

Interaction of soft x-ray laser radiation with material and caused modification of the exposed surface has both physical and practical interests. We irradiated the focusing soft x-ray laser (SXRL) pulses having a wavelength of 13.9 nm and the duration of 7 ps to aluminum (Al) surface. After the SXRL irradiation process, the irradiated Al surface was observed with a scanning electron microscope. The surface modifications caused by SXRL single pulse exposure were clearly seen. In addition, it was found that the conical structures having around 100 nm in diameters were formed in the shallow features. The nano-meter size modified structures at Al surface induced by SXRL pulse is interesting as the newly surface structure. Hence, the SXRL beam would be a candidate for a tool of micromachining. We also provide a thermomechanical modeling of SXRL interaction with Al briefly to explain the surface modification.

36 MATERIALS SCIENCE↗

A pepper-pot emittance meter for low-energy heavy-ion beams

A novel emittance meter has been developed to measure the four-dimensional, transverse phase-space distribution of a low-energy ion beam using the pepper-pot technique. A characteristic feature of this instrument is that the pepper-pot plate, which has a linear array of holes in the vertical direction, is scanned horizontally through the ion beam. This has the advantage that the emittance can also be measured at locations along the beam line where the beam has a large horizontal divergence. A set of multi-channel plates, scintillation screen, and ccd camera is used as a position-sensitive ion detector allowing a large range of beam intensities that can be handled. This paper describes the design, construction, and operation of the instrument as well as the data analysis used to reconstruct the four-dimensional phase-space distribution of an ion beam. Measurements on a 15 keV He{sup +} beam are used as an example.

43 PARTICLE ACCELERATORS↗

Thoron detection with an active Radon exposure meter—First results

For state-of-the-art discrimination of Radon and Thoron several measurement techniques can be used, such as active sampling, electrostatic collection, delayed coincidence method, and alpha-particle-spectroscopy. However, most of the devices available are bulky and show high power consumption, rendering them unfeasible for personal exposition monitoring. Based on a Radon exposure meter previously realized at the Helmholtz Center Munich (HMGU), a new electronic prototype for Radon/Thoron monitoring is currently being developed, which features small size and weight. Operating with pin-diode detectors, the low-power passive-sampling device can be used for continuous concentration measurements, employing alpha-particle-spectroscopy and coincidence event registration to distinguish decays originating either from Radon or Thoron isotopes and their decay products. In open geometry, preliminary calibration measurements suggest that one count per hour is produced by a 11 Bq m{sup −3} Radon atmosphere or by a 15 Bq m{sup −3} Thoron atmosphere. Future efforts will concentrate on measurements in mixed Radon/Thoron atmospheres.

54 ENVIRONMENTAL SCIENCES↗

Optical pulling of airborne absorbing particles and smut spores over a meter-scale distance with negative photophoretic force

We demonstrate optical pulling of single light-absorbing particles and smut spores in air over a meter-scale distance using a single collimated laser beam based on negative photophoretic force. The micron-sized particles are pulled towards the light source at a constant speed of 1–10 cm/s in the optical pulling pipeline while undergoing transverse rotation at 0.2–10 kHz. The pulled particles can be manipulated and precisely positioned on the entrance window with an accuracy of ∼20 μm, and their chemical compositions can be characterized with micro-Raman spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control of the domain of multiple filamentation of terawatt laser pulses along a hundred-meter air path

We report the results of experiments and numerical simulation for multiple filamentation of terawatt femtosecond pulses of a Ti : sapphire laser on a 106-meter long air path under varied initial spatial focusing and laser output power. Highly efficient control of the position and length of the filamentation domain is realised by varying the initial focusing of the laser beam, which provides the movement of the filamentation domain along the entire optical path. The unimodal character of the distribution of the number of plasma channels formed by the laser beam along the optical path is revealed and a correlation of the coordinates corresponding to the maximal number of plasma channels and to the nonlinear focus of the beam as a whole is established. (extreme light fields and their applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Volatile propellant droplet evaporation measurements in metered dose inhaler sprays

Many aerosol products rely on the rapid vaporization of volatile propellants to produce a fine spray. In the simplest case, these are binary mixtures of propellant and a delivered product which undergo a flash-evaporation process leaving only the less volatile product in the resultant droplet. In more complex applications, such as pressurized metered-dose inhalers, the non-propellant component may contain dissolved or suspended drug which precipitates or dries to form a matured particle. The size and morphology of the particles depend strongly on the time-history of the droplet as the propellant evaporates. However, measuring the dynamic evaporation processes that occur in dense sprays containing millions of droplets is challenging. In this paper, we demonstrate a novel application of Ultra Small Angle X-ray Scattering to measure the bulk composition of volatile HFC134a–ethanol sprays and compare the obtained results with simple evaporation models in a dry nitrogen environment. The data reveal that diffusion-limiting processes inside the droplet are equally important as external convection and mixing-limited factors in determining evaporative timescales.

42 ENGINEERING↗