Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploration of Electrochemical Reactions at Organic–Inorganic Halide Perovskite Interfaces via Machine Learning in In Situ Time-of-Flight Secondary Ion Mass Spectrometry

The instability of hybrid organic–inorganic perovskite (HOIP) devices is one of the significant challenges preventing commercialization. Exploring these phenomena is severely limited by the complexity of the intrinsic electrochemistry of HOIPs, the presence of multiple volatile and mobile ionic species, and the possible role of environmentally induced reactions at surfaces and triple-phase junctions. Here, in situ studies of the electrochemistry of methylammonium lead bromide perovskite with the Au electrode interface are reported via light- and voltage-dependent time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging of lateral perovskite heterostructures. While ToF-SIMS allows for the visualization of the chemical composition along the surface and its evolution with light and electrical bias, the interpretation of the multidimensional data obtained is often limited due to strong correlations between chemical signatures and the need to track multiple peaks at once. Here, a machine learning workflow combining the Hough transform and non-negative matrix factorization and no-negative tensor decomposition is developed to avoid this limitation and extract salient features of associated chemical changes and to separate the light- and voltage-dependent dynamics. Finally, combining these in situ characterizations and the machine learning workflow provides comprehensive information on the chemical nature of moving species, ion accumulation, and interfacial electrochemical reactions in HOIP devices.

36 MATERIALS SCIENCE↗

A Search for Amino Acids and Nucleobases in the Martian Meteorite Roberts Massif 04262 Using Liquid Chromatography-Mass Spectrometry

The investigation into whether Mars contains signatures of past or present life is of great interest to science and society. Amino acids and nucleobases are compounds that are essential for all known life on Earth and are excellent target molecules in the search for potential Martian biomarkers or prebiotic chemistry. Martian meteorites represent the only samples from Mars that can be studied directly in the laboratory on Earth. Here, we analyzed the amino acid and nucleobase content of the shergottite Roberts Massif (RBT) 04262 using liquid chromatography-mass spectrometry. We did not detect any nucleobases above our detection limit in formic acid extracts; however, we did measure a suite of protein and nonprotein amino acids in hot-water extracts with high relative abundances of beta-alanine and gamma-amino-eta-butyric acid. The presence of only low (to absent) levels of several proteinogenic amino acids and a lack of nucleobases suggest that this meteorite fragment is fairly uncontaminated with respect to these common biological compounds. The distribution of straight-chained amine-terminal eta-omega-amino acids in RBT 04262 resembled those previously measured in thermally altered carbonaceous meteorites. A carbon isotope ratio of -24(0/00) +/- 6(0/00) for beta-alanine in RBT 04262 is in the range of reduced organic carbon previously measured in Martian meteorites (Steele et al. 2012). The presence of eta-omega-amino acids may be due to a high temperature Fischer-Tropschtype synthesis during igneous processing on Mars or impact ejection of the meteorites from Mars, but more experimental data are needed to support these hypotheses.

Laboratory analysis↗

ExoMars Mars Organic Molecule Analyzer (MOMA) Laser Desorption/Ionization Mass Spectrometry (LDI-MS) Analysis of Phototrophic Communities from a Silica-Depositing Hot Spring in Yellowstone National Park, USA

The Mars Organic Molecule Analyzer (MOMA) is a key scientific instrument on the ExoMars Rover mission. MOMA is designed to detect and characterize organic compounds, over a wide range of volatility and molecular weight, in samples obtained from up to two meters below the martian surface. Thorough analog sample studies are required to best prepare to interpret MOMA data collected on Mars. We present here the MOMA characterization of Mars analog samples collected from an alkaline silica depositing hot spring in Yellowstone National Park, WY, USA. These samples contain microbial streamer communities composed primarily of oxygenic and anoxygenic phototrophs. Additionally, in a study focused on detection of key classes of nonvolatile organics, samples of microbial streamers and their total lipid extract (TLE) have been measured on a MOMA Engineering Test Unit (ETU) instrument using its laser desorption/ionization mass spectrometry (LDI-MS) mode. MOMA LDI-MS detected a variety of lipids and pigments in the TLE sample. Species such as chlorophyll a were also detected from the streamer sample with the help of mass isolation. The results add to the LDI-MS sample characterization database, as well as demonstrate the benefit of using mass isolation on the MOMA instrument to reveal the presence of complex organics, and potential biomarkers, preserved in a natural sample, providing guidance to the in situ analysis of surface samples during Mars operations.

59 BASIC BIOLOGICAL SCIENCES↗

Mass spectrometry and spectroscopic characterization of a tetrameric photosystem I supercomplex from Leptolyngbya ohadii , a desiccation-tolerant cyanobacterium

Cyanobacteria inhabiting desert biological soil crusts face the harsh conditions of the desert. They evolved a suite of strategies toward desiccation-hydration cycles mixed with high light irradiations, etc. In this study we purified and characterized the structure and function of Photosystem I (PSI) from Leptolyngbya ohadii, a desiccation-tolerant desert cyanobacterium. We discovered that PSI forms tetrameric (PSI-Tet) aggregate. We investigated it by using sucrose density gradient centrifugation, clear native PAGE, high performance liquid chromatography, mass spectrometry (MS), time-resolved fluorescence (TRF) and time-resolved transient absorption (TA) spectroscopy. MS analysis identified the presence of two PsaB and two PsaL proteins in PSI-Tet and uniquely revealed that PsaLs are N-terminally acetylated in contrast to non-modified PsaL in the trimeric PSI from Synechocystis sp. PCC 6803. Chlorophyll (Chl) a fluorescence decay profiles of the PSI-Tet performed at 77 K revealed two emission bands at ∼690 nm and 725 nm with the former appearing only at early delay time. The main fluorescence emission peak, associated with emission from the low energy Chls a, decays within a few nanoseconds. TA studies demonstrated that the 725 nm emission band is associated with low energy Chls a with absorption band clearly resolved at ∼710 nm at 77 K. As a result, our work suggests that the heterogenous composition of PsaBs and PsaL in PSI-Tet is related with the adaptation mechanisms needed to cope with stressful conditions under which this bacterium naturally grows.

59 BASIC BIOLOGICAL SCIENCES↗

Direct Observation of Plasma-Stimulated Activation of Surface Species Using Multimodal In Situ/Operando Spectroscopy Combining Polarization-Modulation Infrared Reflection-Absorption Spectroscopy, Optical Emission Spectroscopy, and Mass Spectrometry

Nonthermal plasmas (NTPs) produce reactive chemical environments, including electrons, ions, radicals, and vibrationally excited molecules, that can drive chemistry at temperatures at which such species are thermally inaccessible. There has been growing interest in the integration of conventional catalysis with reactive NTPs to promote novel chemical transformations. Unveiling the full potential of plasma-catalytic processes requires a comprehensive understanding of plasma-catalytic synergies, including characterization of plasma-catalytic surface interactions. In this work, we report on a newly designed multimodal spectroscopic instrument combining polarization-modulation infrared reflection-absorption spectroscopy (PM-IRAS), mass spectrometry, and optical emission spectroscopy (OES) for the investigation of plasma–surface interactions such as those found in plasma catalysis. In particular, this tool has been utilized to correlate plasma-phase chemistry with both surface chemistry and gas-phase products in situ (1) during the deposition of carbonaceous surface species via NTP-promoted nonoxidative coupling of methane and (2) during subsequent activation of surface deposits with an atmospheric pressure and temperature argon plasma jet on both nickel (Ni) and silicon dioxide (SiO 2 ) surfaces. For the first time, the activation of carbonaceous surface species by a NTP on Ni and SiO 2 surfaces to form hydrogen gas and C 2 hydrocarbons was directly observed, where both PM-IRAS and OES measurements suggest that they may form through different pathways. Furthermore, this unique tool for studying plasma–surface interactions could enable more rational design of plasma-stimulated catalytic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A History of Molecular Level Analysis of Natural Organic Matter by FTICR Mass Spectrometry and The Paradigm Shift in Organic Geochemistry

Natural organic matter (NOM) is a complex mixture of biogenic molecules resulting from the deposition and transformation of plant and animal matter. It has long been recognized that NOM plays an important role in many geological, geochemical, and environmental processes. Of particular concern is the fate of NOM in response to a warming climate in environments that have historically sequestered carbon (e.g., peatlands and swamps) but may transition to net carbon emitters. In this review, we will highlight developments in the application of high-field Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) in identifying the individual components of complex NOM mixtures, focusing primarily on the fraction that is dissolved in natural waters (dissolved organic matter or DOM). We will first provide some historical perspective on developments in FTICR technology that made molecular-level characterizations of DOM possible. In conclusion, a variety of applications of the technique will then be described, followed by our view of the future of high-field FTICR MS in carbon cycling research, including a particularly exciting metabolomic approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Picoflow Liquid Chromatography–Mass Spectrometry for Ultrasensitive Bottom-Up Proteomics Using 2-μm-i.d. Open Tubular Columns

In many areas of applications key objectives of chemical separations and analysis are to minimize the sample quantity while maximizing the chemical information obtained. Increasing measurement sensitivity is especially critical for proteomics research, especially when processing trace samples and where multiple measurements are desired. A rich collection of technologies has been developed, but the resulting sensitivity remains insufficient for achieving in-depth coverage of proteomic samples as small as single cells. In this paper, we combine picoliter-scale liquid chromatography (picoLC) with mass spectrometry (MS) to address this issue. The picoLC employs 2-µm-i.d. open tubular column to reduce the sample input needed to greatly increase the sensitivity achieved using electrospray ionization (ESI) with MS. With this picoLC-MS system, we show that we can identify ~1000 proteins reliably using only 30 pg of tryptic peptides, representing a 10–100-fold sensitivity improvement compared with the state-of-the-art liquid chromatography (LC) or capillary electrophoresis (CE)-MS methods. PicoLC-MS extends the limit of separation science and is expected to be a powerful tool for single cell proteomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Absolute quantitation of propranolol from 200-μm regions of mouse brain and liver thin tissues using laser ablation-dropletProbe-mass spectrometry

Rationale: The ability to quantify drugs and metabolites in tissue with sub-mm resolution is a challenging but much needed capability in pharmaceutical research. To fill this void, a novel surface sampling approach combining laser ablation with the commercial dropletProbe automated liquid surface sampling system (LA-dropletProbe) was developed and presented here.Methods: Parylene C-coated 200 × 200 μm tissue regions of mouse brain and kidney thin tissue sections were analyzed for propranolol by laser ablation of tissue directly into a preformed liquid junction. Propranolol was detected by high performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry. Quantitation was achieved via application of a stable isotope-labeled internal standard and an external calibration curve.Results: Absolute concentration of propranolol determined from 200 × 200 µm tissue regions were compared to propranolol concentrations obtained from 2.3-mm-diameter tissue punches of adjacent, non-coated sections using standard bulk tissue extraction protocols followed by regular HPLC-MS/MS analysis. Average concentration of propranolol in both organs determined by the two employed methods agreed within ±12%. Furthermore, the relative abundance of phase II hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous results.Conclusions: This work illustrates that depositing a thin parylene C layer onto thin tissue prior to analysis, which seals the surface and prevents direct liquid extraction of the drug from the tissue, coupled to the novel LA-dropletProbe surface sampling system is a viable approach for sub-mm resolution quantitative drug distribution analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of different getter substrates using two-dimensional gas chromatography with time of flight mass spectrometry

We report while understanding hydrogen uptake by organic based getters such as 1,4-bis(phenylethynyl)benzene (DEB) combined with a palladium(0)bis(dibenzylideneacetone) (Pd(dba) 2 ) catalyst is essential, another crucial element to understand is the decomposition of the DEB, Pd(dba) 2 , and/or substrate material. The breakdown of these materials may create unwanted volatiles, which may interact with and lead to deterioration of sensitive materials. Moreover, it is critical to understand if different substrates cause the getter and/or catalyst to degrade in different manners. Utilizing comprehensive two-dimensional gas chromatography (GC×GC) with time-of-flight mass spectrometry (TOFMS), the presence of volatiles located in the headspace of various DEB/Pd(dba) 2 getter substrates is examined. These samples include a getter infused silicone foam, a hydrogenated getter infused silicone foam, an activated carbon getter pellet, and a hydrogenated activated carbon getter pellet. Application of Fisher ratio (F-ratio) analyses lead to the identification of several compounds that are generated or consumed through the hydrogenation process. These include benzene derivatives such as bibenzyl, benzaldehyde, and vinyl benzoate in the activated carbon pellets and 1,5-diphenyl-3-pentanone, toluene, styrene, and 1–1'(2-pentene 1,5-diyl)bis benzene in the silicone foams, and alkane/alkene derivatives such undecane, 4-tridecene, and decane in the activated carbon pellets and 2,6-dimethyl undecane in the silicone foams. Further comparison of the different hydrogenated getter substrates (e.g. activated carbon pellet and silicone foam) indicates that the different substrates alter the decomposition products created from the degradation of the DEB and Pd(dba) 2 .

47 OTHER INSTRUMENTATION↗

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]↗

The balance of orbital overlap and orbital energy in the activation of methane by actinide cations: insights from inductively coupled plasma tandem mass spectrometry

The actinides present a unique challenge to chemical theory. The classical view of covalent bonding is driven by the extent of spatial overlap of valence orbitals. Modern theory has expanded assessments of covalency to include considerations of orbital energy degeneracy to assess orbital energy mixing between metal and ligand valence orbitals. Actinide–ligand (An–L) bonding has more recently been described as a balance between orbital overlap and orbital energy mixing, where 5f and L valence orbital overlap decreases while energy mixing between An 5f and L valence orbitals increases across the series. To test these existing views, we employed inductively coupled plasma tandem mass spectrometry to examine the kinetic energy dependences of reactions of actinide cations, Th + –Am + , with methane. Further, this is the first experimental report of the energy dependences of methane activation reactions involving the cations of Pa, Np, Pu, and Am and the first experimental determination of transuranic An + –D, An + –CD 2 , An + –CD 3 , and An + –CD bond dissociation energies. The correlation of the measured An + –CD 2 bond energies with E p (6d 2 ) indicates that An + 6d orbitals are the dominant contributors in the An + –CD 2 bonds. Close examination of the relative reactivities of An + offers additional support that the balance of classical and modern views of molecular bonding may lie between Np + and Pu + and that the increased reactivity of Th + –Np + may be attributed to the increased spatial extension of the 5f orbitals whereas covalent An + bond formation may be more driven by the decreasing energies of the 5f orbitals across the actinide series.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of Polar Compounds Condensed on Particulate Matter Using Capillary Electrophoresis-Mass Spectrometry

A new analytical method to aid in the understanding of the organic carbon (OC) phase of particulate matter (PM) from advanced compression ignition (ACI) operating modes, is presented. The presence of NO2 and unburned fuel aromatics in ACI emissions, and the low exhaust temperatures that result from this low temperature combustion strategy, provide the right conditions for the formation of carboxylic acids and nitroaromatic compounds. These polar compounds contribute to OC in the PM and are not typically measured using nonpolar solvent extraction methods such as the soluble organic fraction (SOF) method. The new extraction and detection method employs capillary electrophoresis with electrospray ionization mass spectrometry (CE-ESI MS) and was specifically developed to determine polar organic compounds in the ACI PM emissions. The new method identified both nitrophenols and aromatic carboxylic acids in the ACI PM. The ACI air-fuel stratification mode and NOx emissions were found to correlate with the presence and amount of the individual polar species identified.

Lewis Sr, Samuel↗

Human RNome Project draft human RNome sequence of GM12878, B-cell line, obtained by mass-spectrometry sequencing, long-read sequencing and short-read sequencing.

Here we report the first draft of the human RNome sequence, a reference map of RNA chemical modifications in a human B-cell line. RNA carries a diverse repertoire of chemical modifications that regulate gene expression, cellular function, and responses to physiological and pathological cues. Yet, unlike the genome, no reference map of RNA modifications is available for any human cell. To generate this resource, the Human RNome Project Consortium analyzed a shared RNA preparation from the well-characterized GM12878 B-cell line using short-read sequencing, long-read direct RNA sequencing, and mass spectrometry, generating more than 7.1 billion sequencing reads spanning approximately 1.2 trillion nucleotides. The resulting maps of the human RNome reveal that RNA modifications are organized according to function, transcript architecture, and cellular identity. Modifications concentrate at functional centers of ribosomal and transfer RNAs, follow the canonical topology of N6-methyladenosine in coding transcripts, and form coordinated hotspots in immune regulatory genes. This first reference human RNome provides a foundation for understanding how RNA chemistry shapes cellular identity, human disease, and the development of RNA-based therapeutics.

59 BASIC BIOLOGICAL SCIENCES↗

Quantification of SARS-CoV-2 spike protein expression from mRNA vaccines using isotope dilution mass spectrometry

The advent of mRNA vaccine technology has been vital in rapidly creating and manufacturing COVID-19 vaccines at an industrial scale. To continue to accelerate this leading vaccine technology, an accurate method is needed to quantify antigens produced by the transfection of cells with a mRNA vaccine product. This will allow monitoring of protein expression during mRNA vaccine development and provide information on how changes to vaccine components affects the expression of the desired antigen. Developing novel approaches that allow for high-throughput screening of vaccines to detect changes in antigen production in cell culture prior to in vivo studies could aid vaccine development. Here, we have developed and optimized an isotope dilution mass spectrometry method to detect and quantify the spike protein expressed after transfection of baby hamster kidney cells with expired COVID-19 mRNA vaccines. Five peptides of the spike protein are simultaneously quantified and provide assurance that protein digestion in the region of the target peptides is complete since results between the five peptides had a relative standard deviation of less than 15 %. In addition, two housekeeping proteins, actin and GAPDH, are quantified in the same analytical run to account for any variation in cell growth within the experiment. IDMS allows a precise and accurate means to quantify protein expression by mammalian cells transfected with an mRNA vaccine.

60 APPLIED LIFE SCIENCES↗

Temporal Sampling of Enzymes from Live Cells by Localized Electroporation and Quantification of Activity by SAMDI Mass Spectrometry

Abstract Measuring changes in enzymatic activity over time from small numbers of cells remains a significant technical challenge. In this work, a method for sampling the cytoplasm of cells is introduced to extract enzymes and measure their activity at multiple time points. A microfluidic device, termed the live cell analysis device (LCAD), is designed, where cells are cultured in microwell arrays fabricated on polymer membranes containing nanochannels. Localized electroporation of the cells opens transient pores in the cell membrane at the interface with the nanochannels, enabling extraction of enzymes into nanoliter‐volume chambers. In the extraction chambers, the enzymes modify immobilized substrates, and their activity is quantified by self‐assembled monolayers for matrix‐assisted laser desorption/ionization (SAMDI) mass spectrometry. By employing the LCAD‐SAMDI platform, protein delivery into cells is demonstrated. Next, it is shown that enzymes can be extracted, and their activity measured without a loss in viability. Lastly, cells are sampled at multiple time points to study changes in phosphatase activity in response to oxidation by hydrogen peroxide. With this unique sampling device and label‐free assay format, the LCAD with SAMDI enables a powerful new method for monitoring the dynamics of cellular activity from small populations of cells.

Mukherjee, Prithvijit↗

In Situ Detection of Amino Acids from Bacterial Biofilms and Plant Root Exudates by Liquid Microjunction Surface-Sampling Probe Mass Spectrometry

The plant rhizosphere is a complex and dynamic chemical environment where the exchange of molecular signals between plants, microbes, and fungi drives the development of the entire biological system. Exogenous compounds in the rhizosphere are known to affect plant-microbe organization, interactions between organisms, and ultimately, growth and survivability. The function of exogenous compounds in the rhizosphere is still under much investigation, specifically with respect to their roles in plant growth and development, the assembly of the associated microbial community, and the spatiotemporal distribution of molecular components. A major challenge for spatiotemporal measurements is developing a nondisruptive and nondestructive technique capable of analyzing the exogenous compounds contained within the environment. A methodology using liquid microjunction-surface sampling probe-mass spectrometry (LMJ-SSP-MS) and microfluidic devices with attached microporous membranes was developed for in situ, spatiotemporal measurement of amino acids (AAs) from bacterial biofilms and plant roots. Exuded arginine was measured from a living Pantoea YR 343 biofilm, which resulted in a chemical image indicative of biofilm growth within the device. Spot sampling along the roots of Populus trichocarpa with the LMJ-SSP-MS resulted in the detection of 15 AAs. Of note, variation in AA concentrations across the root system was observed, indicating that exudation is not homogeneous and may be linked to local rhizosphere architecture and different biological processes along the root.

59 BASIC BIOLOGICAL SCIENCES↗

Isolation of Histone from Sorghum Leaf Tissue for Top Down Mass Spectrometry Profiling of Potential Epigenetic Markers

Histones belong to a family of highly conserved proteins in eukaryotes. They pack DNA into nucleosomes as functional units of chromatin. Post-translational modifications (PTMs) of histones, which are highly dynamic and can be added or removed by enzymes, play critical roles in regulating gene expression. In plants, epigenetic factors including histone PTMs are related to their adaptive responses to the environment. Understanding the molecular mechanisms of epigenetic control can bring unprecedented opportunities for engineering solutions to increase the resilience of crops to climate change. Herein, we describe a protocol to isolate the nuclei and purify histones from sorghum leaf tissue. The extracted histones can be analyzed as their intact forms by top-down mass spectrometry (MS) coupled to online reversed-phase (RP) liquid chromatography (LC). Combinations and stoichiometry of multiple PTMs on the same histone proteoform can be readily identified. In addition, histone tail clipping can be detected using the top-down LC-MS workflow thus yielding the global PTM profile of core histones (H4, H2A, H2B, H3). By comparing the PTM profile among samples corresponding to different conditions (e.g. drought vs. control), potential epigenetic marks can be discovered as targets for further characterization using approaches such as chromatin immunoprecipitation – sequencing (ChIP-seq).

59 BASIC BIOLOGICAL SCIENCES↗