Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

The NASA Ames Mars Global Climate Model: Benchmarking Publicly Released Source Code and Model Output

We have recently publicly released source code from the new NASA Ames Mars Global Climate Model (MGCM), which is based on NOAA/GFDL cubed-sphere finite volume (FV3-based) dynamical core (https://github.com/nasa/AmesGCM). We also we have a manuscript in preparation that aims to document the status of the new MGCM, and present selected simulations generated from it with interpretations and comparisons to both observations and the Ames Legacy MGCM. Output from our reference simulation will be made publicly available as well. One of our ongoing goals is to understand the underlying causes for differences between results produced with the new FV3-based dynamical core compared to the Legacy C-grid dynamical core. While the thermal and dynamical fields predicted with the new and Legacy GCMs are broadly similar for much of the year, there are key differences at low resolution when no external drag is applied to the new MGCM. This is particularly clear during a seasonal window of ~100 degrees of Ls surrounding southern summer solstice, when the predicted northern hemisphere polar warming is significantly over-predicted in the new MGCM. When we apply Rayleigh drag throughout much of the tropics and sub-tropics to the new MGCM, the simulated zonal mean structure of the atmosphere is much more consistent with both MCS observations and Legacy MGCM simulations. We note that the Kling et al. (2023; this meeting) study demonstrates that the behavior that we see with Rayleigh drag here can be recovered with high resolution simulations (in the horizontal and in the vertical) or with parameterized orographic and non-orographic gravity waves at lower resolution. While this work is still in progress, our preliminary conclusion is that the new dynamical core is less dissipative than the Legacy dynamical core. At low to moderate resolution, users of the new MGCM will need to be careful to use some sort of external drag, either in the form of gravity wave drag parameterizations or the simpler Rayleigh drag.

Melinda April Kahre↗

Martian B Storm Evolution: Modeling Dust Activity over the Receding South Polar CO 2 Ice Cap at Southern Hemisphere Summer Solstice

Observations of annually recurring, elevated (25 km) atmospheric warming and associated dust concentrations over the south polar cap near Southern Hemisphere (SH) summer solstice are the defining features of the regional dust storm known as the B storm [1]. Our observational analysis of MCS and TES temperature and dust retrievals include all Mars Years (MY) lacking a global dust storm (GDS) between MY 26 and MY 33 (Figure 1). The data indicate the B storm is initiated around perihelion (L s =252°) in the southern midlatitudes and reaches maximum height and intensity over the south pole near SH summer solstice at L s ~267°. At peak intensity, mid-level atmospheric temperatures are elevated by as much as 30 K and mid-level atmospheric dust mixing ratios are more than triple pre-B storm levels (1.5-2 ppm to 7-8 ppm). Cap edge lifting may contribute significantly to initial dust mobilization in the B storm since surface wind stress along the receding cap edge is likely strengthened by the combined effects of the sea breeze circulation and katabatic winds at this time of year [2, 3, 4]. We are investigating dust lifting and lofting near the south pole of Mars during SH summer using the NASA Ames Mars Global Climate Model (MGCM). The NASA Ames MGCM is a finite-volume numerical model with a cubed sphere grid ideal for modeling processes at high latitudes. Initial simulations at low resolution (4x4 degrees) capture some elevated dust and associated warming at the south pole around L s =265°, but the model fails to capture the intensity of the B storm. We will examine and present the model-predicted surface stress and vertical velocities near the receding seasonal CO 2 cap edge and at the south pole during solstice. Finally, we will present higher resolution simulations to better capture small-scale dynamics and features at the pole.

Courtney M. L. Batterson↗

The B Regional Dust Storm in the New NASA Ames Mars GCM

Introduction The Thermal Emission Spectrometer (TES) and the Mars Climate Sounder (MCS) instruments have been ob- serving global dust and temperature on Mars twice daily for a combined ∼12 Mars Years (MYs). Analysis of these data by [5] reveal three highly repeatable, regional scale dust events occurring annually during years lack- ing a global dust storm (GDS). Named the "A," "B," and "C" storms in seasonal order, these recurring dust storms develop in the southern hemisphere of Mars during the perihelion season(Ls =180°–360°)when Mars is closest to the sun and the southern hemisphere experiences sum- mer [5]. The "A" and "C" storms occur in the southern midlatitudes where they amplify the Hadley circulation causing dynamical warming in the northern hemisphere. In contrast, the "B" storm (hereafter, B storm) and its ef- fects are entirely confined to the south pole [5]. All three storms are large enough to inject dust above the boundary layer [8]. As a result, the annually-recurring regional storms produce significant temperature perturbations in the middle atmosphere, raising zonal mean 50 Pa ( 25 km) temperatures above 200 K (Figure 1) [5]. In this work, we seek to identify the mechanisms responsible for lofting dust into the middle atmosphere during the B storm by simulating the storm with the new NASA Ames Mars Global Climate Model (MGCM). We find that the simulated B storm is driven by a series of dust plumes that form in the high southern latitudes during southern summer solstice. We also find that radiative-dynamic feedbacks between airborne dust and incoming shortwave radiation are crucial for the pluming mechanism.

C M L Batterson↗

Exploring the Climatic Impact of Bi-Modal Dust Particle Size Distributions During the MY34/2018 Global Dust Storm with the NASA Ames Mars Global Climate Model.

We have implemented a bi-modal dust lifting scheme in the NASA Ames Mars Global Climate Model (GCM) and investigated the climatic impact on the MY34/2018 Global Dust Storm (GDS). We found that the climate is measurably responsive to the inclusion of a second, smaller dust mode. Dust tends to be lifted through a deeper column in the atmosphere, which is reflected in the climate as changes to atmospheric temperature, tide amplitudes, and surface temperatures. Adding a modest fraction of a smaller dust mode improves simulations during the GDS compared to Curiosity semi-diurnal tide observations as well as Mars Climate Sounder (MCS) T15 brightness temperatures

R A Urata↗

EVALUATION OF SPRING OPERATED RELIEF VALVE MAINTENANCE INTERVALS AND EXTENSION OF MAINTENANCE TIMES USING A WEIBULL ANALYSIS WITH MODIFIED BAYESIAN UPDATING

The Savannah River Site (SRS) spring operated pressure relief valve (SORV) maintenance intervals were evaluated using an approach provided by the American Petroleum Institute (API RP 581) for risk-based inspection technology (RBI). In addition, the impact of extending the inspection schedule was evaluated using Monte Carlo Simulation (MCS). The API RP 581 approach is characterized as a Weibull analysis with modified Bayesian updating provided by SRS SORV proof testing experience. Initial Weibull parameter estimates were updated as per SRS's historical proof test records contained in the Center for Chemical Process Safety (CCPS) Process Equipment Reliability Database (PERD). The API RP 581 methodology was used to estimate the SORV's probability of failing on demand (PFD), and the annual expected risk. The API RP 581 methodology indicates that the current SRS maintenance plan is conservative. Cost savings may be attained in certain mild service applications that present low PFD and overall risk. Current practices are reviewed and recommendations are made for extending inspection intervals. The paper gives an illustration of the inspection costs versus the associated risks by using API RP 581 Risk Based Inspection (RBI) Technology. A cost effective maintenance frequency balancing both financial risk and inspection cost is demonstrated.

02 PETROLEUM↗

Application of spectral summing to suspect low level debris drums at Los Alamos National Laboratory

The spectral summing technique developed by Pajarito Scientific Corporation (PSC) is a unique modeling technique that is being employed by the Waste Disposition Project - Low Level Waste Disposal (WDP-LLWD) Group at Los Alamos National Laboratory (LANL). This technique is being used to disposition low-level radioactive waste that has dropped out of the transuranic (TRU) category and has no place to go unless it can be proven to be LLW and not TRU. The TRU program at LANL run by Mobile Characterization Services (MCS) employs two High Efficiency Neutron Counters (HENC) with built-in gamma assay systems to assay radioactive waste for shipment and disposal as TRU waste at the Waste Isolation Pilot Plant (WIPP) at Carlsbad, New Mexico. As well as being certified for WIPP assays, the HENC systems can also be used for low-level waste assays for disposal at LANL or off-site disposal facilities, such as the Nevada Test Site (NTS). Some of the waste processed through the HENC systems cannot be confirmed TRU due to the absence of detected TRU alpha emitters above the TRU cutoff of 100 nCi/g. This waste becomes suspect low-level waste (SLLW). In many cases, the waste also can't be classified as LLW because the minimum detectable activity (MDA) of TRU radionuclides is above the 100 nCi/g level. These wastes that do not have enough detectable TRU activity to be classified as TRU waste and have too high a MDA to be classified as LLW enter a radioactive waste characterization limbo that prevents their dispositioning as either TRU waste or LLW. Spectral summing allows an experienced gamma spectroscopy analyst to add the HENC gamma spectra of a number of similar waste items together to form a consolidated (summed) spectrum. This summed spectrum contains the assay results of the group of items rather than the individual item, and gamma peaks that were not discernable in the individual spectra become quantifiable in the summed spectrum. The group of waste items can then be properly classified as LLW based on the summed spectrum and valid assay values can be assigned for disposal. This technique is being successfully used to dispose of LLW debris drums from LANL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of spectral summing to indeterminate suspect low-level drums at Los Alamos National Laboratory

An analytical technique developed by Pajarito Scientific Corporation (PSC), utilizing spectral summing of spectra from groups of drums of similar waste type, is being employed by the Waste Disposition Project - Low Level Waste Disposal (WDP-LLWD) Group at Los Alamos National Laboratory (LANL). This technique has been used to disposition low-level radioactive waste that has dropped out of the transuranic (TRU) category and has no place to go unless it can be proven to be LLW and not TRU. The TRU program at LANL run by Mobile Characterization Services (MCS) employs two High Efficiency Neutron Counters (HENC) with built-in gamma assay systems to assay radioactive waste for shipment and disposal as TRU waste at the Waste Isolation Pilot Plant (WIPP) at Carlsbad, New Mexico. As well as being certified for WIPP assays, the HENC systems can also be used for low-level waste assays for disposal at LANL or off-site disposal facilities, such as the Nevada Test Site (NTS). Some of the waste processed through the HENC systems cannot be confinned TRU due to the absence of detected TRU alpha emitters above the TRU cutoff of 100 nCi/g. This waste becomes suspect low-level waste (SLLW). In many cases, the waste also can't be classified as LLW because the minimum detectable activity (MDA) of TRU radio nuclides is above the 100 nCi/g level. These wastes that do not have enough detectable TRU activity to be classified as TRU waste and have too high a MDA to be classified as LLW enter a radioactive waste characterization indetenninate status that prevents their dispositioning as either TRU waste or LLW. Spectral summing allows an experienced ganuna spectroscopy analyst to add the HENC gamma spectra of a number of similar waste items together to form a consolidated (summed) spectrum. This summed spectrum contains the assay results of the group of items rather than the individual item, and gamma peaks that were not discernable in the individual spectra can become quantifiable in the summed spectrum and the MDA for group sum is reduced. The group of waste items can then be properly classified as LLW based on the summed spectrum and valid assay values can be assigned for disposal. This technique has been successfully applied to a set of 52 debris drums - with individual MDA > 100 nCi/g - with a resulting group total TRU alpha activity concentration below 40nCi/g. Further application of the technique at LANL to other waste drums that are measured on a WIPP certified HENC system is planned and good candidate drum sets are being evaluated as indeterminate situations develop.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of spectral summing to indeterminate suspect low-level drums at Los Alamos National Laboratory

The spectral summing technique developed by Pajarito Scientific Corporation (PSC) is a unique modeling technique that is being employed by the Waste Disposition Project - Low Level Waste Disposition (WDP-LLWD) Group at Los Alamos National Laboratory (LANL). This technique has been used to disposition low-level radioactive waste that has dropped out of the transuranic (TRU) category and has no disposal path unless it can be proven to be LLW and not TRU. The TRU program at LANL run by Mobile Characterization Services (MCS) employs High Efficiency Neutron Counters (HENC) with built-in gamma assay systems to assay radioactive waste for shipment and disposal as TRU waste at the Waste Isolation Pilot Plant (WIPP) at Carlsbad, New Mexico. As well as being certified for WIPP assays, the HENC systems can also be used for low-level waste assays for disposal at LANL or off-site disposal facilities, such as the Nevada Test Site (NTS). Some of the waste processed through the HENC systems cannot be confirmed TRU due to the absence of detected TRU alpha emitters above the TRU cutoff of 100 nCi/g. This waste becomes suspect low-level waste (SLLW). In many cases, the waste also can't be classified as LLW because the minimum detectable activity (MDA) of TRU radionuclides is above the 100 nCi/g level. These wastes that do not have enough detectable TRU activity to be classified as TRU waste and have TRU MDAs > 100nCi/g enter a radioactive waste characterization indeterminate state that prevents their dispositioning as either TRU waste or LLW. Spectral summing allows an experienced gamma spectroscopy analyst to add the HENC gamma spectra of a number of similar waste items together to form a consolidated (summed) spectrum. This summed spectrum contains the assay results of the group of items rather than the individual item, and gamma peaks that were not discemable in the individual spectra become quantifiable in the summed spectrum and the MDA for the group sum is reduced. The group of waste items can then be properly classified as LLW waste on the summed spectrum and valid assay values can be assigned for disposal. This technique has been successfully applied to a set of 52 debris drums - with individual MDA > 100nCi/g - with a resulting group total TRU alpha activity concentration below 40nCi/g. Further application of the technique at LANL to other debris drums and sludge drums that were measured on a WIPP certified HENe is planned and good candidate drum sets are being evaluated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building America Case Study: Field Testing an Unvented Roof with Asphalt Shingles in a Cold Climate, Boilingbrook, Illinois

Insulating roofs with dense-pack cellulose (instead of spray foam) has moisture risks, but is a lower cost approach. If moisture risks could be addressed, buildings could benefit from retrofit options, and the ability to bring HVAC systems within the conditioned space. Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a 'control' vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except the vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only had slight issues, such as rusted fasteners and sheathing grain raise. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a 'diffusion vent' detail, capped with vapor permeable roof membrane. Some ridge sections were built as a conventional unvented roof, as a control. In the control unvented roofs, roof peak RHs reached high levels in the first winter; as exterior conditions warmed, RHs quickly fell. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Predictive Control of A Matrix-Converter Based Solid State Transformer for Utility Grid Interaction

The matrix converter solid state transformer (MC-SST), formed from the back-to-back connection of two three-to-single-phase matrix converters, is studied for use in the interconnection of two ac grids. The matrix converter topology provides a light weight and low volume single-stage bidirectional ac-ac power conversion without the need for a dc link. Thus, the lifetime limitations of dc-bus storage capacitors are avoided. However, space vector modulation of this type of MC-SST requires to compute vectors for each of the two MCs, which must be carefully coordinated to avoid commutation failure. An additional controller is also required to control power exchange between the two ac grids. In this paper, model predictive control (MPC) is proposed for an MC-SST connecting two different ac power grids. The proposed MPC predicts the circuit variables based on the discrete model of MC-SST system and the cost function is formulated so that the optimal switch vector for the next sample period is selected, thereby generating the required grid currents for the SST. Simulation and experimental studies are carried out to demonstrate the effectiveness and simplicity of the proposed MPC for such MC-SST-based grid interfacing systems.

Xue, Yaosuo↗

Multi-scale processes driving tropical convection and influence of the aerosol (Final Technical Report)

This DOE GoAmazon collaborative project between scientists in the US and Brazil addresses fundamental processes that drive tropical deep convection including aerosol effects. The results provide guidance for improving the parameterizations of cloud and aerosol effects by increasing the knowledge of processes at work in tropical convection, especially over tropical land. Highlights include: • GoAmazon2014/5 observations permitted, for the first time, a comprehensive evaluation of the strong relationship between lower free tropospheric moisture and deep convective onset over the Amazon (Schiro et al. 2016, JAS; Schiro et al. 2018b, PNAS; Chakraborty et al. 2018, ACP; Schiro and Neelin 2018c). A set of diagnostics for deep convective onset has been established using data from the GoAmazon2014/5 campaign (Schiro et al. 2016, JAS), highlighting similarities and differences between the convective transition statistics over tropical land versus corresponding statistics from ARM campaigns in the tropical Western Pacific. The initial set of diagnostics has been provided as a module to be incorporated into the ARM Diagnostics Package of Shaocheng Xie and coworkers, which is being integrated into the PCMDI and E3SM diagnostics packages. Additionally, a set of downdraft diagnostics to inform model parameterizations has been developed (Schiro and Neelin 2018a, ACP). • These diagnostics have been used in constraining the behavior of modeled convective parameterizations. This includes using them with parameter perturbation experiments in the Community Earth System Model to show which parameter ranges are consistent with observed onset statistics, and to show that the primary causal direction of the water vapor-precipitation relationship is via the impact of mixing processes and free tropospheric moisture on convection (Kuo et al. 2017, JAS). Lintner et al. (2017, GRL) used this impact of free tropospheric moisture to systematically analyze issues in the simulation of Amazon rainfall in the CMIP5 model ensemble. • Leveraging the multi-instrument GoAmazon observations, Schiro et al. (2018, PNAS) are able to provide for the first time an empirical mixing using radar wind profiler data that provides a good predictor of precipitation for both mesoscale convective systems and smaller-scale convection. In addition, buoyancy estimated from these results is a good predictor of precipitation across the seasonal and diurnal cycles (Schiro and Neelin 2018c, JAS) and permits the effects of aerosols to be distinguished from those of the thermodynamic environment in the transition to deep convection (Chakraborty et al. 2018, ACP). • Placing the GoAmazon campaign in a larger context, in collaboration with U. São Paulo investigators, Rehbein et al. (2018) analyzed the characteristics of the mesoscale convective systems (MCS) that affect Amazon rainfall, including origins, lifetimes, propagation speed and displacement. de Barros Soares et al. (2017) establish statistically significant observed warming trends over much of South America and are able to attribute the origin of this to anthropogenic forcing based on the agreement of climate model simulations with and without anthropogenic forcings. This analysis left open the attribution of precipitation trends due to large natural variability. Barkhardorian et al. (2018) provide evidence indicating that the observed regional precipitation decrease and drying during recent over northern South America during recent austral springs will continue and intensify in the course of unfolding anthropogenic climate change.

54 ENVIRONMENTAL SCIENCES↗

Muon-Computed Tomography using POCA Trajectory for Imaging Spent Nuclear Fuel in Dry Storage Casks

Cosmic ray muon-computed tomography (μCT) is a new imaging modality with unique characteristics that can be particularly important for applications in nuclear proliferation detection and international treaty verification. Using cosmic ray muons for nuclear security presents several potential advantages. Among others, muons are generated naturally in the atmosphere, can penetrate high-density materials, and are freely available. No radiological sources are required and consequently there is no associated radiological dose. Recently, the feasibility of using muons for imaging spent nuclear fuel stored in shielded casks has been explored and has been proved beneficial. However, challenges in μCT imaging include low muon flux of ~10,000 muons/m2/min, the effects of multiple Coulomb scattering (MCS) blurring the image, and inefficiency in being able to use all recorded muons for imaging. In this paper, we argue that the use of muon tracing should produce tomographic muon images with improved quality – or more quickly for the same image quality – compared to the case where conventional methods are used. In our paper, we report on the development and assessment of a novel muon tracing method for μCT. The proposed method back projects the muon’s scattering angle into each pixel crossed by its PoCA trajectory then forward projects the variance of the scattering angle in each pixel to detector bins along the muon’s incident horizontal direction. Two scenarios were simulated to assess the expected detection capability of this proposed method. GEANT4 was used to model the main characteristics of 1-60 GeV muons through matter. The simulated images showed an expected improvement in resolution and a reduced the reliance on the muon momentum information compared to a more conventional muon tomography method.

Liu, Zhengzhi↗

Megawatt Scale Charging System Architecture

The paper presents a novel and futuristic architecture for a megawatt charging system (MCS) capable of charging light, medium, and heavy-duty vehicles. The station architecture consists of multiport systems with each multiport interfacing the grid, EV, PV, and energy storage system through an intermediate DC bus. The station being a “system of systems” requires a complex software layer with intelligence, control, and communication for effective coordination and utilization of the power electronic interfaces and the assets. The paper elaborates on the station architecture and the associated software layer used for control and coordination. Additionally, the paper provides an approach to utilize hardware-in-the-loop (HIL) capabilities to validate such architectures.

Krishna Moorthy, Radha↗

Protecting Lake Ontario - Treating Wastewater from the Remediated Low-Level Radioactive Waste Management Facility - 13227

The Port Granby Project is part of the larger Port Hope Area Initiative, a community-based program for the development and implementation of a safe, local, long-term management solution for historic low level radioactive waste (LLRW) and marginally contaminated soils (MCS). The Port Granby Project involves the relocation and remediation of up to 0.45 million cubic metres of such waste from the current Port Granby Waste Management Facility located in the Municipality of Clarington, Ontario, adjacent to the shoreline of Lake Ontario. The waste material will be transferred to a new suitably engineered Long-Term Waste Management Facility (LTWMF) to be located inland approximately 700 m from the existing site. The development of the LTWMF will include construction and commissioning of a new Wastewater Treatment Plant (WWTP) designed to treat wastewater consisting of contaminated surface run off and leachate generated during the site remediation process at the Port Granby Waste Management Facility as well as long-term leachate generated at the new LTWMF. Numerous factors will influence the variable wastewater flow rates and influent loads to the new WWTP during remediation. The treatment processes will be comprised of equalization to minimize impacts from hydraulic peaks, fine screening, membrane bioreactor technology, and reverse osmosis. The residuals treatment will comprise of lime precipitation, thickening, dewatering, evaporation and drying. The distribution of the concentration of uranium and radium - 226 over the various process streams in the WWTP was estimated. This information was used to assess potential worker exposure to radioactivity in the various process areas. A mass balance approach was used to assess the distribution of uranium and radium - 226, by applying individual contaminant removal rates for each process element of the WTP, based on pilot scale results and experience-based assumptions. The mass balance calculations were repeated for various flow and load scenarios. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential of U.S. Marine and Offshore Wind Energy to Power Marine Carbon Dioxide Removal

The goal of this project was to provide a preliminary feasibility assessment of powering different marine carbon dioxide removal (mCDR), carbon capture (mCC), and carbon sequestration (mCS) strategies with marine energy. The investigation focused on methods with clear power requirements at sea beyond monitoring such as artificial upwelling, deep ocean storage, electrochemical (eChem) mCDR and mCC, offshore microalgae cultivation, and seaweed farming and sinking. The project found that eChem mCDR powered by marine energy and offshore wind energy available in the United States could meet global CDR scales needed by 2040 and 2050 to limit warming to 1.5 degrees C by 2100 and marine energy alone could greatly contribute to reaching scales needed by 2040. Note that this preliminary estimate assumes that it is possible to harvest all the marine and offshore wind resources available in the United States with existing technology options. Though the biological methods were limited in scale they still hold promise in developing carbon negative fuels and products which can reduce emissions in the short term.

afforestation↗

Conceptual design of inverted core lead bismuth eutectic fast reactor for marine applications

The development of an inverted core fast reactor aims to generate 60 MWth for about 30 Effective Full Power Years without refueling. The reactor design is a transportable reactor using UO{sub 2} fuel and lead-bismuth-eutectic cooled designed for marine applications and is intended to improve the reactor performances compared to the normal core design: better condition for passive cooling system capability by lower core pressure drop, taking advantage of potential power uprate from the lower maximum fuel temperature. Systematic design processes are presented in this work: fuel pin geometry selection, fuel assembly (FA) design, and core design. A relationship between pressure drops, coolant velocity, maximum fuel temperature, coolant channel diameter, and fuel volume fraction was introduced in a single graph used as a tool to select fuel pin geometry. Fuel fabrication capability also took place in consideration of FA design which led to 7 holes per FA, and two-dimensional temperature distribution studies were also carried out. Core design processes including radial zoning, axial zoning, and core optimization were conducted using Monte Carlo code MCS, which is UNIST CORE laboratory in-house code. The current core design uses 3 fuel enrichment levels and 3 FA types to control the local power distribution and power shift during its lifetime. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Feasibility of lead-bismuth-cooled fast reactor with fuel shuffling strategy

This paper investigates the feasibility of fuel shuffling of the Advanced Nitride-fueled Simplified 100 MWe (ANTS-100e) Lead-bismuth-cooled Fast Reactor (LFR). The preliminary design has the active core of 235 cm in diameter and 100 cm high. The core is composed of 138 hexagonal fuel assemblies enclosed with a 15-15Ti steel duct. The core adopts the onion zoning with the two zones of low-enriched uranium for a better breeding capability to maximize the first cycle length to 10 effective full-power years (EFPYs). The fuel shuffling study is performed by using the UNIST in-house Monte Carlo code MCS. The neutronic parameters such as the multiplication factor and burnup are being investigated. The fuel shuffling strategy is evaluated through several loading patterns for flattening radial power distribution. It is also found that the core with fuel shuffling could lengthen the core lifetime by more than 5 EFPYs without introducing fresh fuel. Thus, it appears that the ANTS-100e can be principally designed to have the second cycle with another 10 EFPYs if introducing fresh fuel into the core. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Muon momentum reconstruction in ICARUS-T600 LArTPC via Multiple Scattering

The SBN program at Fermilab investigates the possible existence of eV-scale sterile neutrinos. This work focuses on reconstructing muon momentum in $\nu$-Ar interactions within the ICARUS-T600 LArTPC detector using Multiple Coulomb Scattering (MCS), the only viable method for non-contained muons. Two algorithms are evaluated: the Gran Sasso algorithm (2D, Collection view) and the MicroBooNE algorithm (3D angles), applied to 2391 simulated and 2255 real stopping muon tracks (0.4-1 GeV/c). Performance is assessed via bias and resolution, using range-based momentum as a reference. Two enhanced versions of the Gran Sasso algorithm are also developed: one combining all three wire plane views, and one using 3D angles. Results show that the MicroBooNE algorithm performs slightly better, with resolution down to 14\% in simulation and 16\% in real data. These improvements significantly boost $\nu_\mu$ CC statistics, enhancing sensitivity to $\nu_\mu$ disappearance and 3+1 oscillation signals.

Chiello, Giovanni [Pisa U.] (ORCID:000900064571071↗