Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Preventing Reverse Engineering of Critical Industrial Data with DIOD

Business analytics augmented by artificial intelligence and machine learning (AI/ML) have revolutionized the role of data in the modern world. In recent years, businesses have incorporated data into their decision-making process for better prediction, risk-assessment, content creation, etc. While such businesses often seek to leverage the full use of their data through third-party AI/ML services, they are often hampered by the risks of data leaks, reverse-engineering, stolen technology, etc. that often have disastrous consequences for businesses and their stakeholders alike. Thus, there arises a need for data masking prior to its transmission that obfuscates proprietary information while preserving the information relevant for AI/ML applications. In order to meet the needs of industrial data which are significantly different from those of data warehouses, previous work proposed an efficient time and space-scalable data masking paradigm known as the deceptive infusion of data (DIOD) methodology. The present work expands upon this work by leveraging existing reverse-engineering capabilities to facilitate the decomposition of industrial data into its proprietary and AI/ML-relevant parts, referred to as fundamental and inference metadata respectively. Both sets of metadata are further obfuscated in accordance with the DIOD methodology to create the DIOD rendition of the industrial data, which is rendered immune to reverse-engineering by discarding proprietary information and only preserving AI/ML-relevant information. Additionally, constraints of the original DIOD manuscript are relaxed using mutual information by configuring the methodology to the target AI/ML application to unlock the full potential of the DIOD methodology. As an example, data from a nuclear reactor is transformed into that from a nonlinear spring-mass system with different levels of data masking as required by the generic system and the target application.

97 MATHEMATICS AND COMPUTING↗

Enabling EUV Resist Research at the 1x and Smaller Regime

With the slipping of the insertion node for extreme ultraviolet lithography, demands on resist resolution have increased further stressing sensitivity requirements. A variety of resists, both chemically amplified and not, have been developed meeting resolution needs, but falling short on sensitivity and line-width roughness (LWR). Note that resolution is an absolute mandatory requirement, the true tradeoff that must be considered is between sensitivity and contact hole printing is a crucial application for extreme ultraviolet lithography and is particularly challenged by resist sensitivity due to inherent inefficiencies in darkfield contact printing. Checkerboard strong phase shift masks have the potential to alleviate this problem through a 4× increase in optical efficiency. The feasibility of this method is demonstrated using the SEMATECH-Berkeley Microfield Exposure Tool pseudo phase shift mask configuration and preliminary results are provided on the fabrication of an etched multilayer checkerboard phase shift mask.

36 MATERIALS SCIENCE↗

Birefringent Glass‐Engraved Quasi‐Linear Nanograting Metasurface Based on Self‐Organizing Process for Large Aperture High Power Laser Applications

All-glass metasurface “nanograting” structures that exhibit birefringence in the formed layer are reported. The key enabler of this work is ion beam processing at an angle sufficiently off-normal incidence, inducing self-assembly of a deposited metal layer into quasi-linear metallic features that can function as an etching mask. As a result, a fused silica metasurface, monolithic to the underlying substrate, is demonstrated at 375 nm wavelength to exhibit a phase delay angle of 30° between the principal axes. The capability of an angled etch mask replenishment process is also demonstrated for achieving deeper etch depth and for increasing the grating period, another first – to the best of the knowledge. This is the first display of a technology capable of fabricating glass-engraved near-linear grating structure with a feature-to-feature period as small as 118.6 nm. Furthermore, this technology has the potential to generate grating-like structures with periods as small as 12.4 nm, as demonstrated here with reactive ion beam processing assisted mask assembly. Furthermore, these structures are shown to have reflectivity < 0.4% across the wavelength band 350 nm – 1000 nm. Such a technology can enable laser-durable grating structures for the deep-UV and even down to soft X-ray wavelengths.

Ray, Nathan J. [Lawrence Livermore National Labora↗

High resolution for confocal fluorescence microscopy via extending zero-region of super-oscillation

Superoscillation is the phenomenon that is observed when a wave oscillates locally faster than its highest Fourier component. Although previous reports have been shown that the superoscillation is highly attractive for imaging, however, the small zero-region area of the superoscillation increases the remarkable effect of the outsidelobes. In this work, we introduce a method using a binary phase mask with radial polarization to extend the zero-region of the superoscillation for high numerical aperture objectives. We successfully design a binary phase mask combining with a radial polarization to obtain a big zero-region of the superoscillation. Evaluation methods rely on point spread function and simulation images are presented. The results demonstrate that our proposed method is very effective for suppressing the outsidelobes. In addition, we show that our technique becomes more effective by adding an amplitude mask.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Image-Guided Positioning for Frameless Intracranial Radiosurgery

Purpose: The standard for target alignment and immobilization in intracranial radiosurgery is frame-based alignment and rigid immobilization using a stereotactic head ring. Recent improvements in image-guidance systems have introduced the possibility of image-guided radiosurgery with nonrigid immobilization. We present data on the alignment accuracy and patient stability of a frameless image-guided system. Methods and Materials: Isocenter alignment errors were measured for in vitro studies in an anthropomorphic phantom for both frame-based stereotactic and frameless image-guided alignment. Subsequently, in vivo studies assessed differences between frame-based and image-guided alignment in patients who underwent frame-based intracranial radiosurgery. Finally, intratreatment target stability was determined by image-guided alignment performed before and after image-guided mask immobilized radiosurgery. Results: In vitro hidden target localization errors were comparable for the framed (0.7 {+-} 0.5 mm) and image-guided (0.6 {+-} 0.2 mm) techniques. The in vivo differences in alignment were 0.9 {+-} 0.5 mm (anteroposterior), -0.2 {+-} 0.4 mm (superoinferior), and 0.3 {+-} 0.5 mm (lateral). For in vivo stability tests, the mean distance differed between the pre- and post-treatment positions with mask-immobilized radiosurgery by 0.5 {+-} 0.3 mm. Conclusion: Frame-based and image-guided alignment accuracy in vitro was comparable for the system tested. In vivo tests showed a consistent trend in the difference of alignment in the anteroposterior direction, possibly due to torque to the ring and mounting system with frame-based localization. The mask system as used appeared adequate for patient immobilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging Protocol Optimization for Delineation of Gross Tumor Volume in Hypopharyngeal and Laryngeal Tumors

Purpose: To optimize the use of MRI for delineation of gross tumor volume for radiotherapy treatment planning purposes in hypopharyngeal and laryngeal tumors. Methods and Materials: Magnetic resonance images (T1 weighted and T2 weighted) of a healthy volunteer were acquired using a 1.5 T and 3.0 T MR scanner. Various receiver coils were investigated that were compatible with the immobilization mask needed for reliable coregistration with computed tomography data. For the optimal receiver coil, the influence of resolution, slice thickness, and strength of magnetic field on the signal-to-noise ratio (SNR) was studied. Feasibility of the definitive protocol was tested on patients with hypopharyngeal (n = 19) and laryngeal (n = 42) carcinoma. Results: Large differences in SNR were obtained for the various coils. The SNR values obtained using surface coils that were compatible with the immobilization mask were three times higher than those obtained using a standard head-and-neck coil and five times higher than those obtained using a body coil. High-resolution images (0.4 x 0.4 x 4 mm{sup 3}) showed superior anatomic detail and resulted in a 4-min scan time. Image quality at 3.0 T was not significantly better compared with 1.5 T. In 3 patients the MR study could not be performed; for 5 patients images were severely deteriorated by motion artefacts. High-quality MR images were obtained in 53 patients. Conclusions: High-resolution MR images of the hypopharynx and larynx can be obtained in the majority of patients using surface receiver coils in combination with the radiotherapy mask. These MR images can be successfully used for tumor delineation in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale graph neural network autoencoders for interpretable scientific machine learning

The goal of this work is to address two limitations in autoencoder-based models: latent space interpretability and compatibility with unstructured meshes. This is accomplished here with the development of a novel graph neural network (GNN) autoencoding architecture with demonstrations on complex fluid flow applications. To address the first goal of interpretability, the GNN autoencoder achieves reduction in the number nodes in the encoding stage through an adaptive graph reduction procedure. Further, this reduction procedure essentially amounts to flowfieldconditioned node sampling and sensor identification, and produces interpretable latent graph representations tailored to the flowfield reconstruction task in the form of so-called masked fields. These masked fields allow the user to (a) visualize where in physical space a given latent graph is active, and (b) interpret the time-evolution of the latent graph connectivity in accordance with the time-evolution of unsteady flow features (e.g. recirculation zones, shear layers) in the domain. To address the goal of unstructured mesh compatibility, the autoencoding architecture utilizes a series of multi-scale message passing (MMP) layers, each of which models information exchange among node neighborhoods at various lengthscales. The MMP layer, which augments standard single-scale message passing with learnable coarsening operations, allows the decoder to more efficiently reconstruct the flowfield from the identified regions in the masked fields. Analysis of latent graphs produced by the autoencoder for various model settings are conducted using unstructured snapshot data sourced from large-eddy simulations in a backward-facing step (BFS) flow configuration with an OpenFOAM-based flow solver at high Reynolds numbers.

97 MATHEMATICS AND COMPUTING↗

Successful delivery of adjuvant external beam radiotherapy for ependymoma in a patient with Ondine's curse

Ondine's curse is a rare, potentially life-threatening disorder characterized by loss of automatic breathing during sleep and preserved voluntary breathing. It is seldom encountered in the radiotherapy clinic but can pose significant technical challenges and safety concerns in the delivery of a prescribed radiation course. We report a unique case of successful delivery of radiotherapy for ependymoma in a patient with Ondine's curse. A 53-year-old gentleman presented with vertigo when lying down. Brain magnetic resonance imaging revealed an enhancing mass in the floor of the fourth ventricle. He underwent maximal safe resection. Pathology revealed ependymoma. The patient was referred for radiotherapy. Computed tomography simulation was performed in supine position with 3-point thermoplastic mask immobilization. Sequential TomoTherapy plans were developed. At first scheduled treatment, shortly after mask placement, his arms went limp and he was unresponsive. Vitals showed oxygen saturation 83%, pulse 127, and blood pressure 172/97 mm Hg. He was diagnosed with Ondine's curse thought secondary to previous brainstem damage; the combination of lying flat and pressure from the mask was causing him to go into respiratory arrest. As supine positioning did not seem clinically advisable, he was simulated in prone position. A RapidArc plan and a back-up conformal plan were developed. Prescriptions were modified to meet conservative organs-at-risk constraints. Several strategies were used to minimize uncertainties in set-up reproducibility associated with prone positioning. He tolerated prone RapidArc treatments well. The report highlights the importance of applying practical patient safety and treatment planning/delivery strategies in the management of this challenging case.

61 RADIATION PROTECTION AND DOSIMETRY↗

Phase Imaging: A Compressive Sensing Approach

Since Wolfgang Pauli posed the question in 1933, whether the probability densities |Ψ(r)|² (real-space image) and |Ψ(q)|² (reciprocal space image) uniquely determine the wave function Ψ(r) [1], the so called Pauli Problem sparked numerous methods in all fields of microscopy [2, 3]. Reconstructing the complete wave function Ψ(r) = a(r)e-iφ(r) with the amplitude a(r) and the phase φ(r) from the recorded intensity enables the possibility to directly study the electric and magnetic properties of the sample through the phase. In transmission electron microscopy (TEM), electron holography is by far the most established method for phase reconstruction [4]. Requiring a high stability of the microscope, next to the installation of a biprism in the TEM, holography cannot be applied to any microscope straightforwardly. Recently, a phase retrieval approach was proposed using conventional TEM electron diffractive imaging (EDI). Using the SAD aperture as reciprocal-space constraint, a localized sample structure can be reconstructed from its diffraction pattern and a real-space image using the hybrid input-output algorithm [5]. We present an alternative approach using compressive phase-retrieval [6]. Our approach does not require a real-space image. Instead, random complimentary pairs of checkerboard masks are cut into a 200 nm Pt foil covering a conventional TEM aperture (cf. Figure 1). Used as SAD aperture, subsequently diffraction patterns are recorded from the same sample area. Hereby every mask blocks different parts of gold particles on a carbon support (cf. Figure 2). The compressive sensing problem has the following formulation. First, we note that the complex-valued reciprocal-space wave-function is the Fourier transform of the (also complex-valued) real-space wave-function, Ψ(q) = F[Ψ(r)], and subsequently the diffraction pattern image is given by |Ψ(q)|2 = |F[Ψ(r)]|2. We want to find Ψ(r) given a few differently coded diffraction pattern measurements yn = |F[HnΨ(r)]|2, where the matrices Hn encode the mask structure of the aperture. This is a nonlinear inverse problem, but has been shown to be solvable even in the underdetermined case [6]. Since each diffraction pattern yn contains diffraction information from selected regions of the same sample, the differences in each pattern contain local phase information, which can be combined to form a full estimate of the real-space wave-function[7]. References: [1] W. Pauli in “Die allgemeinen Prinzipien der Wellenmechanik“, ed. H Geiger and W Scheel, (Julius Springer, Berlin). [2] A. Tonomura, Rev. Mod. Phys. 59 (1987), p. 639. [3] J. Miao et al, Nature 400 (1999), p. 342. [4] H. Lichte et al, Annu. Rev. Mater. Res. 37 (2007), p. 539. [5] J. Yamasaki et al, Appl. Phys. Lett. 101 (2012), 234105. [6] P Schniter and S Rangan. Signal Proc., IEEE Trans. on. 64(4), (2015), pp. 1043. [7] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Schneider, Sebastian↗

Pressure-Induced Local Structure Distortions in Cu(pyz)F(2)(H(2)O)(2)

We employed infrared spectroscopy along with complementary lattice dynamics and spin density calculations to investigate pressure-driven local structure distortions in the copper coordination polymer Cu(pyz)F{sub 2}(H{sub 2}O){sub 2}. Here, pyz is pyrazine. Our study reveals rich and fully reversible local lattice distortions that buckle the pyrazine ring, disrupt the bc-plane O-H {hor_ellipsis} F hydrogen-bonding network, and reinforce magnetic property switching. The resiliency of the soft organic ring is a major factor in the stability of this material. Interestingly, the collective character of the lattice vibrations masks direct information on the Cu-N and Cu-O linkages through the series of pressure-induced Jahn-Teller axis switching transitions, although Cu-F bond softening is clearly identified above 3 GPa. These findings illustrate the importance of combined bulk and local probe techniques for microscopic structure determination in complex materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient facemask decontamination via forced ozone convection

The COVID-19 crisis has taken a significant toll on human life and the global economy since its start in early 2020. Healthcare professionals have been particularly vulnerable because of the unprecedented shortage of Facepiece Respirators (FPRs), which act as fundamental tools to protect the medical staff treating the coronavirus patients. In addition, many FPRs are designed to be disposable single-use devices, creating an issue related to the generation of large quantities of non-biodegradable waste. In this contribution, we describe a plasma-based decontamination technique designed to circumvent the shortages of FPRs and alleviate the environmental problems posed by waste generation. The system utilizes a Dielectric Barrier Discharge (DBD) to generate ozone and feed it through the fibers of the FPRs. The flow-through configuration is different than canonical ozone-based sterilization methods, in which the equipment is placed in a sealed ozone-containing enclosure without any flow through the mask polymer fibers. We demonstrate the rapid decontamination of surgical masks using Escherichia coli ( E. coli ) and Vesicular Stomatitis Virus (VSV) as model pathogens, with the flow-through configuration providing a drastic reduction in sterilization time compared to the canonical approach. We also demonstrate that there is no deterioration in mask structure or filtration efficiency resulting from sterilization. Finally, we show that this decontamination approach can be implemented using readily available tools, such as a plastic box, a glass tube, few 3D printed components, and the high-voltage power supply from a plasma globe toy. The prototype assembled for this study is portable and affordable, with effectiveness comparable to that of larger and more expensive equipment.

36 MATERIALS SCIENCE↗

Planck intermediate results: LIV. The Planck multi-frequency catalogue of non-thermal sources$^\star$

This paper presents the Planck Multi-frequency Catalogue of Non-thermal (i.e. synchrotron-dominated) Sources (PCNT) observed between 30 and 857 GHz by the ESA Planck mission. This catalogue was constructed by selecting objects detected in the full mission all-sky temperature maps at 30 and 143 GHz, with a signal-to-noise ratio (S/N)> 3 in at least one of the two channels after filtering with a particular Mexican hat wavelet. As a result, 29 400 source candidates were selected. Then, a multi-frequency analysis was performed using the Matrix Filters methodology at the position of these objects, and flux densities and errors were calculated for all of them in the nine Planck channels. This catalogue was built using a different methodology than the one adopted for the Planck Catalogue of Compact Sources (PCCS) and the Second Planck Catalogue of Compact Sources (PCCS2), although the initial detection was done with the same pipeline that was used to produce them. The present catalogue is the first unbiased, full-sky catalogue of synchrotron-dominated sources published at millimetre and submillimetre wavelengths and constitutes a powerful database for statistical studies of non-thermal extragalactic sources, whose emission is dominated by the central active galactic nucleus. Together with the full multi-frequency catalogue, we also define the Bright Planck Multi-frequency Catalogue of Non-thermal Sources (PCNTb), where only those objects with a S/N > 4 at both 30 and 143 GHz were selected. In this catalogue 1146 compact sources are detected outside the adopted Planck GAL070 mask; thus, these sources constitute a highly reliable sample of extragalactic radio sources. We also flag the high-significance subsample (PCNThs), a subset of 151 sources that are detected with S/N > 4 in all nine Planck channels, 75 of which are found outside the Planck mask adopted here. The remaining 76 sources inside the Galactic mask are very likely Galactic objects.

79 ASTRONOMY AND ASTROPHYSICS↗

A statistical approach to optimization of alumina etching in a high density plasma

Inductively coupled plasma (ICP) reactive ion etching of Al{sub 2}O{sub 3} with fluorine-based gas chemistry in a high density plasma reactor was carried out in an initial investigation aimed at data storage applications. A statistical design of experiments was implemented to optimize etch performance with respect to process variables such as ICP power, platen power, direct current (dc) bias, and pressure. Both soft photoresist masks and hard metal masks were investigated in terms of etch selectivity and surface properties. The reverse power dependence of dc bias on the ratio of ICP to platen power was elucidated. Etch mechanisms in terms of physical and ion enhanced chemical etchings were discussed. The F-based chemistry greatly enhances the etch rate of alumina compared to purely physical processes such as ion milling. Etch rates as high as 150 nm/min were achieved using this process. A practical process window was developed for high etch rates, with reasonable selectivity to hard masks, with the desired profile, and with low substrate bias for minimal damage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temporal Dispersion of a Spectrometer

The temporal dispersion of an optical spectrometer has been characterized for a variety of conditions related to optical diagnostics to be fielded at the National Ignition Facility (e.g., Full-Aperture Backscatter Station, Thomson Scattering). Significant time smear is introduced into these systems by the path length difference through the spectrometer. The temporal resolution can be calculated to depend only on the order of the grating, wavelength, and the number of grooves illuminated. To enhance the temporal dispersion, the spectral gratings can be masked limiting the number of grooves illuminated. Experiments have been conducted to verify these calculations. The size and shape of masks are investigated and correlated to the exact shape of the temporal instrument function, which is required when interpreting temporally resolved data. The experiments used a 300fs laser pulse and a picosecond optical streak camera to determine the temporal dispersion. This was done for multiple spectral orders, gratings, and optical masks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Contrast of Subpicosecond Microelectron Bunch Trains

We recently demonstrated that electron bunch trains with a controllable number of bunches and adjustable subpicosecond spacing can be produced using a mask technique. In this paper we calculate the bunch train contrast as a function of the beam betatron size at the mask {sigma}{sub {beta}} and of the diameter d of the mask wires separated by a period D. As expected, when {sigma}{sub {beta}}/(d/2) the contrast is high and decreases with increasing {sigma}{sub {beta}}/(d/2)

43 PARTICLE ACCELERATORS↗

Effect of interwire separation on growth kinetics and properties of site-selective GaAs nanowires

We report tuning of the growth kinetics, geometry, and properties of autocatalytic GaAs nanowires (NW) by precisely controlling their density on SiO{sub 2}-mask patterned Si (111) substrates using selective area molecular beam epitaxy. Using patterned substrates with different mask opening size (40–120 nm) and pitch (0.25–3 μm), we find that the NW geometry (length, diameter) is independent of the opening size, in contrast to non-catalytic GaAs NWs, whereas the NW geometry strongly depends on pitch, i.e., interwire separation and NW density. In particular, two distinct growth regimes are identified: a diffusion-limited regime for large pitches (low NW density) and a competitive growth regime for smaller pitches (high NW density), where axial and radial NW growth rates are reduced. The transition between these two regimes is significantly influenced by the growth conditions and shifts to smaller pitches with increasing As/Ga flux ratio. Ultimately, the pitch-dependent changes in growth kinetics lead to distinctly different photoluminescence properties, highlighting that mask template design is a very critical parameter for tuning intrinsic NW properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Negative ion beam characterisation in BATMAN by mini-STRIKE: Improved design and new measurements

The ITER project requires additional heating provided by two injectors of neutral beams resulting from the neutralisation of accelerated negative ions. To study and optimise negative ion production, the SPIDER test facility (particle energy 100keV; beam current 50A) is under construction in Padova, with the aim of testing beam characteristics and to verify the source proper operation. The SPIDER beam will be characterised by the instrumented calorimeter STRIKE, whose main components are one-directional carbon fibre carbon composite tiles. Some prototype tiles have been employed in 2012 as a small-scale version (mini-STRIKE) of the entire system to investigate the features of the beam from BATMAN at IPP-Garching. As the BATMAN beamlets are superposed at the measurement position, about 1m from the grounded grid, an actively cooled copper mask is located in front of the tiles; holes in the mask create an artificial beamlet structure. Recently the mini-STRIKE has been updated, taking into account the results obtained in the first campaign. In particular the spatial resolution of the system has been improved by increasing the number of the copper mask holes. Moreover a custom measurement system has been realized for the thermocouple signals and employed in BATMAN in view of its use in SPIDER. The present contribution gives a description of the new design of the system as well as of the thermocouple measurements system and its field test. A new series of measurements has been carried out in BATMAN. The BATMAN beam characterisation in different experimental conditions is presented.

43 PARTICLE ACCELERATORS↗