Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Design and Fabrication of the Superconducting Horizontal Bend Magnet for the Super High Momentum Spectrometer at Jefferson Lab

A collaboration exists between NSCL and JLab to design and build JLab's Super High Momentum Spectrometer (SHMS) horizontal bend magnet that allows the bending of the 12 GeV/c particles horizontally by 3° to allow SHMS to reach angles as low as 5.5°. Two full size coils have been wound and are cold tested for both magnetic and structural properties. Each coil is built from 90 layers of single-turn SSC outer conductor cable. An initial test coil with one third the turns was fabricated to demonstrate that the unique saddle shape with fully contoured ends could be wound with Rutherford superconducting cable. Learned lessons during the trial winding were integrated into the two complete full-scale coils that are now installed in the helium vessel. The fabrication of the iron yoke, cold mass, and thermal shield is complete, and assembly of the vacuum vessel is in progress. This paper presents the process and progress along with the modified magnet design to reduce the fringe field in the primary beam region and also includes the impact of the changes on coil forces and coil restraint system.

43 PARTICLE ACCELERATORS↗

Preliminary Radiological Considerations for the Design and Operation of NSLS-II Storage Ring and Booster Synchrotron

Radiological conditions for the design and operation of NSLS II Storage Ring and Booster Synchrotron have been analyzed using the presently available design parameters. The Booster Synchrotron will be housed in the same tunnel as the Storage Ring at NSLS II. Calculations of the resulting radiation fields and required shielding have been made for normal stored beam loss and loss of beam during injection at the septum/extraction magnets.

36 MATERIALS SCIENCE↗

Activation Analysis of Soil, Air and Water near the NSLS-II Accelerator Enclosures

The radiation environment in the accelerator enclosures is sufficiently high energy to permit the activation of air inside the accelerator enclosures, soil surrounding the concrete shielding of the enclosures and the coolant water used for cooling various components of the accelerator system like magnets etc. Bremsstrahlung is generated inside the accelerator enclosures by the radiative interaction of the electron beam with the accelerator components.

36 MATERIALS SCIENCE↗

Transversely driven coherent beam oscillations and specifications for high-frequency ESR dipole power supply current ripple

We study coherent transverse beam oscillations in the EIC electron storage ring (ESR), to specify the tolerance for high-frequency ripple of the dipole magnet power supplies. To avoid unacceptable proton emittance growth from the oscillating beam-beam kick from the electrons, the amplitude of these oscillations at the proton betatron frequency needs to be limited to about 1e-4 fraction of the beam size at the interaction point. We show that the oscillations potentially caused by the ESR magnet dipole power supply ripple could be substantial, but still tolerable, if we account for the eddy current shielding in the vacuum chamber.

43 PARTICLE ACCELERATORS↗

Engineering Challenges in Antiproton Triggered Fusion Propulsion

During the last decade antiproton triggered fusion propulsion has been investigated as a method for achieving high specific impulse, high thrust in a nuclear pulse propulsion system. In general the antiprotons are injected into a pellet containing fusion fuel with a small amount of fissionable material (i.e., an amount less than the critical mass) where the products from the fission are then used to trigger a fusion reaction. Initial calculations and simulations indicate that if magnetically insulated inertial confinement fusion is used that the pellets should result in a specific impulse of between 100,000 and 300,000 seconds at high thrust. The engineering challenges associated with this propulsion system are significant. For example, the antiprotons must be precisely focused. The pellet must be designed to contain the fission and initial fusion products and this will require strong magnetic fields. The fusion fuel must be contained for a sufficiently long time to effectively release the fusion energy, and the payload must be shielded from the radiation, especially the excess neutrons emitted, in addition to many other particles. We will review the recent progress, possible engineering solutions and the potential performance of these systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic field extraction of trap-based electron beams using a high-permeability grid

A method to form high quality electrostatically guided lepton beams is explored. Test electron beams are extracted from tailored plasmas confined in a Penning-Malmberg trap. The particles are then extracted from the confining axial magnetic field by passing them through a high magnetic permeability grid with radial tines (a so-called “magnetic spider”). An Einzel lens is used to focus and analyze the beam properties. Numerical simulations are used to model non-adiabatic effects due to the spider, and the predictions are compared with the experimental results. Improvements in beam quality are discussed relative to the use of a hole in a high permeability shield (i.e., in lieu of the spider), and areas for further improvement are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection efficiency of microchannel plates for e{sup −} and π{sup −} in the momentum range from 17.5 to 345 MeV/c

High-energy e{sup –} and π{sup –} were measured by the multichannel plate (MCP) detector at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The measurements provide the absolute detection efficiencies for these particles: 5.8% ± 0.5% for electrons in the beam momenta range 17.5–300 MeV/c and 6.0% ± 1.3% for pions in the beam momenta range 172–345 MeV/c. The pulse height distribution determined from the measurements is close to an exponential function with negative exponent, indicating that the particles penetrated the MCP material before producing the signal somewhere inside the channel. Low charge extraction and nominal gains of the MCP detector observed in this study are consistent with the proposed mechanism of the signal formation by penetrating radiation. A very similar MCP ion detector will be used in the Neutral Ion Mass (NIM) spectrometer designed for the JUICE mission of European Space Agency (ESA) to the Jupiter system, to perform measurements of the chemical composition of the Galilean moon exospheres. The detection efficiency for penetrating radiation determined in the present studies is important for the optimisation of the radiation shielding of the NIM detector against the high-rate and high-energy electrons trapped in Jupiter’s magnetic field. Furthermore, the current studies indicate that MCP detectors can be useful to measure high-energy particle beams at high temporal resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adult head-sized coil-based low-field MRI

An ultra-low field pre-pulse Magnetic Resonance Imaging (PMRI) system for a head includes RF coils defining a bore for head access, a pre-pulse coil outside the RF coils, and a coil assembly including a main magnetic field coil and gradient coils outside the pre-pulse coil. The PMRI system includes a first cylindrical shield concentric with the RF coils and made from conductive materials. The first cylindrical shield partially encloses the RF coils and inside the pre-pulse coil for shielding the RF coils from environmental electromagnetic disturbances.

Schiff, Steven J.↗

Improving the Fermilab Booster Notching Efficiency, Beam Losses and Radiation Levels

A fast vertical 1.08-m long kicker (notcher) located in the Fermilab Booster Long-05 straight section is currently used to remove 3 out of 84 circulating bunches after injection to generate an abort gap. With the maximum magnetic field of 72.5 Gauss, it removes only 87% of the 3-bunch intensity at 400 MeV, with 75% loss on pole tips of the focusing Booster magnets, 11% on the Long-06 collimators, and 1% in the rest of the ring. We propose to improve the notching efficiency and reduce beam loss in the Booster by using three horizontal kickers in the Long-12 section. STRUCT calculations show that using horizontal notchers, one can remove up to 96% of the 3-bunch intensity at 400-700 MeV, directing 95% of it to a new beam dump at the Long-13 section. This fully decouples notching and collimation. The beam dump absorbs most of the impinging proton energy in its jaws. The latter are encapsulated into an appropriate radiation shielding that reduces impact on the machine components, personnel and environment to the tolerable levels. MARS simulations show that corresponding prompt and residual radiation levels can be reduced ten times compared to the current ones.

43 PARTICLE ACCELERATORS↗

SU-GG-T-49: Real Time Dose Verification for Novel Shielded Balloon Brachytherapy

Purpose: The validation of a novel approach for reducing skindoses to an acceptable level during Accelerated Partial Breast Irradiation (APBI) when the balloon-to-skin distance is inadequate (less than 7 mm) is reported. The study uses a real time dose verification method for a metallic shielded balloon applicator using scintillation fiber technology. Method and Materials: Partial shielding of the radiationdose to the skin using iron or other ferrous powder could enable the extension of APBI to some patients. With small external and pre-determined magnetic fields (<few Gauss), the metallic elements deposition can be controlled on the inner surface of a balloon. Geant4 simulations were used to generate an attenuation dose curve for various radiation lengths after cross-calibration with dedicated data acquired at Jefferson Lab. Some powder was then injected into various inflated MammoSite and rectal balloons within realistic breast and torso phantoms of differing sizes. The dose on the external surface of the skin was measured from a 6.1 Ci {sup 192}Ir of a GammaMed 12i afterloader unit, with a MOSFET,ion chamber and scintillating fiber array detectors. Results: Realistic Monte Carlo simulation studies for the amount and distribution of the required shielding material were compared to dedicated phantom data. A decrease of the skindose was measured to an acceptable level (~350-450 cGy) during standard breast Brachytherapy treatments with relatively weak magnetic fields. Additional measurements provided negligible corrections (< few %) on the saline water density from the suspended ironpowder.Conclusion: This project opens the possibility to increasing the survival expectancy and minimizing negative side effects during brachytherapy treatments, as well as improving cosmetic outcome for all APBI patients. The proposed method may also be used in other procedures for brain, heart, rectal, or vaginal cancers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Remote Handling and Maintenance in the Facility for Rare Isotope Beams

Michigan State University (MSU) in East Lansing, MI was selected by the U.S. Department of Energy (DOE) to design and establish a Facility for Rare Isotope Beams (FRIB), a cutting-edge research facility to advance the understanding of rare nuclear isotopes and the evolution of the cosmos. The research conducted at the FRIB will involve experimentation with intense beams of rare isotopes within a well-shielded target cell that will result in activation and contamination of components. The target cell is initially hands-on accessible after shutdown and a brief cool-down period. Personnel are expected to have hands-on access to the tops of shielded component modules with the activated in-beam sections suspended underneath. The modules are carefully designed to include steel shielding for protecting personnel during these hand-on operations. However, as the facility has greater levels of activation and contamination, a bridge mounted servomaniputor may be added to the cell, to perform the disconnecting of services to the component assemblies. Dexterous remote handling and exchange of the modularized activated components is completed at a shielded window workstation with a pair of master-slave manipulators. The primary components requiring exchange or maintenance are the production target, the beam wedge filter, the beam dump, and the beam focusing and bending magnets. This paper provides an overview of the FRIB Target Facility remote handling and maintenance design requirements, concepts, and techniques.

36 MATERIALS SCIENCE↗

Structural, Electrical, and Magnetic Properties of Ferrite-Reinforced PANI Composites

A Y-type hexagonal ferrite with chemical composition CaBaCo{sub 2}In{sub 0.5}Fe{sub 11.5}O{sub 22} was prepared by a sol-gel auto combustion technique. Y-ferrite/PANI nanocomposites were prepared by in situ polymerization of PANI with general formula CaBaCo{sub 2}In{sub 0.5}Fe{sub 11.5}O{sub 22} (1-x) + PANI (x) (x = 0.30, 0.50, 0.8, and 1) with nomenclature CF1, CF2, CF3, and P respectively. The samples were characterized by X-ray diffraction (XRD) and electrical and magnetic measurements. X-ray diffraction revealed that Y-type ferrite was successfully prepared in a single phase form. DC resistivity increases with increasing ferrite filler in nanocomposites due to large resistive behavior of ferrite in conducting polymer matrix. The dielectric constant, dielectric loss, and AC conductivity decreases with the increase of ferrite content. The dielectric is high due to interfacial polarization at low frequency, and it is low at high frequency following Maxwell-Wagner model. The coercivity increases with the decrease of ferrite filler content whereas saturation magnetization and remanence decreases which is due to random distribution of ferrite filler particles in PANI matrix. Due to large coercivity and low values of ε′ and ε″, the present samples may be useful in recording media and electromagnetic shielding.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cluster Synthesis and Direct Ordering of Rare-Earth Transition-Metal Nanomagnets

Rare-earth transition-metal (R-TM) alloys show superior permanent magnetic properties in the bulk, but the synthesis and application of R-TM nanoparticles remains a challenge due to the requirement of high-temperature annealing above about 800 degrees C for alloy formation and subsequent crystalline ordering. Here we report a single-step method to produce highly ordered R-TM nanoparticles such as YCo(5) and Y(2)Co(17), without high-temperature thermal annealing, by employing a cluster-deposition system and investigate their structural and magnetic properties. The direct ordering is highly desirable to create and assemble R-TM nanoparticle building blocks for future permanent-magnet and other significant applications.

Balasubramanian, B↗

High-precision evaluation of the magnetic moment of the helion

NMR spectra of samples containing a mixture of hydrogen deuteride HD with pressure of about 80 atm and helium-3 with partial pressure of about 1 atm are analyzed. The ratio of the resonance frequencies of the nuclei, F({sup 3}He)/F(H{sub 2}), is determined to be 0.761786594(2), which is equal to the magnetic moment of the helion (bound in a helium atom) in the units of the magnetic moment of a proton (bound in molecular hydrogen). The uncertainty of two digits in the last place corresponds to a relative error of {delta}[F({sup 3}He)/F(H{sub 2})] = 2.6 Multiplication-Sign 10{sup -9}. The use of the known calculated data on the shielding of nuclei in the helium-3 atom ({sigma}({sup 3}He) = 59924(2) Multiplication-Sign 10{sup -9}) and on the shielding of protons in hydrogen ({sigma}(H{sub 2}) = 26288(2) Multiplication-Sign 10{sup -9}) yields a value of {mu}({sup 3}He)/{mu}{sub p} = -0.761812217(3) for the free magnetic moment of the helion in the units of the proton magnetic moment.

74 ATOMIC AND MOLECULAR PHYSICS↗

Functional Janus structured liquids and aerogels

Janus structures have unique properties due to their distinct functionalities on opposing faces, but have yet to be realized with flowing liquids. We demonstrate such Janus liquids with a customizable distribution of nanoparticles (NPs) throughout their structures by joining two aqueous streams of NP dispersions in an apolar liquid. Using this anisotropic integration platform, different magnetic, conductive, or non-responsive NPs can be spatially confined to opposite sides of the original interface using magnetic graphene oxide (mGO)/GO, Ti 3 C 2 T x /GO, or GO suspensions. The resultant Janus liquids can be used as templates for versatile, responsive, and mechanically robust aerogels suitable for piezoresistive sensing, human motion monitoring, and electromagnetic interference (EMI) shielding with a tuned absorption mechanism. The EMI shields outperform their current counterparts in terms of wave absorption, i.e., SE T ≈ 51 dB, SE R ≈ 0.4 dB, and A = 0.91, due to their high porosity ranging from micro- to macro-scales along with non-interfering magnetic and conductive networks imparted by the Janus architecture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Verification of the Prompt Radiation Shielding Design of the ESS Accelerator

Fermilab will perform prompt radiation and shielding verification studies for the European Spallation Source ERIC (ESS) accelerator tunnel and existing penetration layouts using the latest information on the beam line and existing models of magnets and cryomodules. The input information about the assumptions, geometry layout, etc. will be provided by the Safety Group (accelerator division, ESS). The MEDT department of the Accelerator Division, Fermilab will provide the results of the studies. MARS15, a Fermilab a multi-purpose Monte-Carlo code developed since 1974, is at the heart of this effort. MARS15 is used for detailed simulation of hadronic and electromagnetic cascades in an arbitrary 3-D geometry of shielding, accelerator, detector and spacecraft components with energy ranging from a fraction of an electronvolt to 100 TeV. This work will provide additional validation of recent additions to the physical models in the code, including the code capabilities to simulate cascades and generate a variety of results in complex media.

43 PARTICLE ACCELERATORS↗

A portable cryostat for the cold transfer of polarized solid HD targets: HDice-I

We developed a device with moveable liquid nitrogen and liquid helium volumes that is capable of reaching over 2 m into the coldest regions of a cryostat or dilution refrigerator and reliably extracting or installing a target of solid, polarized hydrogen deuteride (HD). This Transfer Cryostat incorporates a cylindrical neodymium rare-earth magnet that is configured as a Halbach dipole, which is maintained at 77 K and produces a 0.1 T field around the HD target. Multiple layers provide a hermetic 77 K-shield as the device is used to maintain a target at 2 K during a transfer between cryostats. Our tests with frozen-spin HD show very little polarization loss for either H (-1±2%, relative) or D (0±3%, relative) over typical transfer periods. Multiple target transfers with this apparatus have shown an overall reliability of about 95% per transfer, which is a significant improvement over earlier versions of the device.

42 ENGINEERING↗

OPTICAL SPECTRAL VARIABILITY OF THE VERY HIGH ENERGY GAMMA-RAY BLAZAR 1ES 1011+496

We present results of five years of optical (UBVRI) observations of the very high energy gamma-ray blazar 1ES 1011+496 at the MDM Observatory. We calibrated UBVRI magnitudes of five comparison stars in the field of the object. Most of our observations were done during moderately faint states of 1ES 1011+496 with R {approx}> 15.0. The light curves exhibit moderate, closely correlated variability in all optical wavebands on timescales of a few days. A cross-correlation analysis between optical bands does not show significant evidence for time lags. We find a positive correlation (Pearson's r = 0.57; probability of non-correlation P(>r) {approx} 4 x 10{sup -8}) between the R-band magnitude and the B-R color index, indicating a bluer-when-brighter trend. Snapshot optical spectral energy distributions exhibit a peak within the optical regime, typically between the V and B bands. We find a strong (r = 0.78; probability of non-correlation P(>r) {approx} 10{sup -15}) positive correlation between the {nu}F{sub {nu}} peak flux and the peak frequency, best fit by a relation {nu}F {sup pk}{sub {nu} {proportional_to}} {nu} {sup k}{sub pk} with k = 2.05 {+-} 0.17. Such a correlation is consistent with the optical (synchrotron) variability of 1ES 1011+496 being primarily driven by changes in the magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗