Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Characteristics of Ferromagnetic Flux Focusing Lens in the Development of Surface/Subsurface Flaw Detector

Electromagnetic NDE techniques have in the past steered away from the use of ferromagnetic materials. Although their high permeabilities lead to increased field levels, the properties of ferrous elements in the presence of alternating magnetic fields are difficult to determine. In addition, their use leads to losses which can be minimized through the use of low conductivity ferrites. In fact, the eddy current probes which do incorporate ferromagnetic materials have focused on these losses and the shielding which can be obtained by surrounding a probe with a high permeability, conducting material. Eddy current probes enclosed in conducting and magnetic shields have been used to prevent the generated fields from interacting with materials in the vicinity of the probe, such as when testing near material boundaries. A recent invention has used ferromagnetic shielding to magnetically separate individual concentric eddy current probes in order to eliminate cross-talk between the probes so that simultaneous detection of different types of flaws at different depths can be achieved. In contrast to the previous uses of ferromagnetic materials purely as magnetic shields, an electromagnetic flaw detector recently developed at NASA Langley Research Center takes advantage of the flux focusing properties of a ferromagnetic mild steel in order to produce a simple, effective device for the non-destructive evaluation of conducting materials. The Flux Focusing Eddy Current Probe has been shown to accurately measure material thickness and fatigue damage. The straight forward flaw response of the probe makes the device ideal for rapid inspection of large structures, and has lead to its incorporation in a computer controlled search routine to locate fatigue crack tips and monitor experimental fatigue crack growth experiments.

Wincheski, Buzz↗

Structural Design and Thermal Analysis for Thermal Shields of the MICE Coupling Magnets

A superconducting coupling magnet made from copper matrix NbTi conductors operating at 4 K will be used in the Muon Ionization Cooling Experiment (MICE) to produce up to 2.6 T on the magnet centerline to keep the muon beam within the thin RF cavity indows. The coupling magnet is to be cooled by two cryocoolers with a total cooling capacity of 3 W at 4.2 K. In order to keep a certain operating temperature margin, the most important is to reduce the heat leakage imposed on cold surfaces of coil cold mass assembly. An ntermediate temperature shield system placed between the coupling coil and warm vacuum chamber is adopted. The shield system consists of upper neck shield, main shields, flexible connections and eight supports, which is to be cooled by the first stage cold heads of two ryocoolers with cooling capacity of 55 W at 60 K each. The maximum temperature difference on the shields should be less than 20 K, so the thermal analyses for the shields with different thicknesses, materials, flexible connections for shields' cooling and structure design for heir supports were carried out. 1100 Al is finally adopted and the maximum temperature difference is around 15 K with 4 mm shield thickness. The paper is to present detailed analyses on the shield system design.

42 ENGINEERING↗

Compact ExB mass separator for heavy ion beams

A compact ExB mass separator that deflects beam by 30 deg. has been designed and built to prove its principle of operation. The main part of the separator is contained in a shielding box of 11 cm long, 9 cm wide, and 1.5 cm high. An electromagnet of 7 cm pole diameter produced variable magnetic field in the mass separation region instead of a couple of permanent magnets which is to be used in the final design. The experimental result agreed well with the theoretical prediction, and larger mass ions is bent with less magnetic field with the aid of the deflection electric field. The reduction in resolving power for mass separation due to the deflection electric field has been investigated experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FMEA on the superconducting torus for the Jefferson Lab 12 GeV accelerator upgrade

As part of the Jefferson Lab 12GeV accelerator upgrade project, Hall B requires two conduction cooled superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration and the second is an actively shielded solenoidal magnet system consisting of 5 coils. Both magnets are to be wound with Superconducting Super Collider-36 NbTi strand Rutherford cable soldered into a copper channel. This paper describes the various failure modes in torus magnet along with the failure modes that could be experienced by the torus and its interaction with the solenoid which is located in close proximity.

43 PARTICLE ACCELERATORS↗

Jefferson Lab CLAS12 Superconducting Solenoid magnet Requirements and Design Evolution

As part of the Jefferson Lab 12GeV accelerator upgrade project, one of the experimental halls (Hall B) requires two superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration and the second is an actively shielded solenoidal magnet system consisting of 5 coils. In this presentation the physics requirements for the 5 T solenoid magnet, design constraints, conductor decision, and cooling choice will be discussed. The various design iterations to meet the specification will also be discussed in this presentation.

Rajput-Ghoshal, Renuka↗

Options for Shielding Tokamak Cooling Water Electrical Components against High Magnetic Fields

The Tokamak Cooling Water System (TCWS) Instrumentation and Control (I&C) components of ITER will be located in areas of relatively high magnetic fields. Previous tests on electrical and I&C components have indicated that shielding will be required to protect these components from such magnetic fields. To accomplish this, studies were performed by AREVA Federal Services (AFS) in support of the TCWS Design project with the intent of identifying an optimal solution for shielding I&C components. This report presents a summary of these studies and presents design options for providing magnetic shielding to ITER TCWS I&C components and electrical equipment that are susceptible to the magnetic fields present.

Korsah, Kofi↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase and Frequency Locked Magnetron

Phase and Frequency locked magnetrons have many important uses from phased array ground penetrating radars to SRF sources. We report on the recent progress in making such a magnetron. The ferrite/garnet material has passed bakeout and outgassi ng tests with outgassing rates well below the requirements. The magnetic field requirements for adjusting the frequency by changing the microwave properties of the ferrite/garnet have been determined. The design of the anode structure with ferrites, magne tic shielding, and magnetic bias has been completed for a low power test. We report on the design status. Muons, Inc. has negotiated an contract with a manufacturing firm, L-3 Electron Devices California Tube Laboratory, Inc., to be the Manufacturing Part ner for the commercialization of this technology and support these Phase II efforts.

43 PARTICLE ACCELERATORS↗

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

Simulations for preliminary design of a multi-cathode DC electron gun for eRHIC

The proposed electron ion collider, eRHIC, requires a large average polarized electron current of 50 mA, which is more than 20 times higher than the present experimental output of a single, highly polarized electron source, based on cesiated super-lattice GaAs. To meet eRHIC's requirement for current, we designed a multicathode DC electron gun for injection. The twenty-four GaAs cathodes emit electrons in sequence, then are combined on axis by a rotating field (or 'funnelled'). In addition to its ultra-high vacuum requirements, the multicathode DC electron gun will place high demand on the electric field symmetry, the magnetic field shielding, and on preventing arcing. In this paper, we discuss our results from a 3D simulation of the latest model for this gun. The findings will guide the actual design in future. Their preliminary design of a multi-cathode electron source for eRHIC demonstrated tolerable fields and reasonable results in both field and particle simulations.

43 PARTICLE ACCELERATORS↗

Non-perturbative calculation of molecular magnetic properties within current-density functional theory

We present a novel implementation of Kohn–Sham density-functional theory utilizing London atomic orbitals as basis functions. External magnetic fields are treated non-perturbatively, which enable the study of both magnetic response properties and the effects of strong fields, using either standard density functionals or current-density functionals—the implementation is the first fully self-consistent implementation of the latter for molecules. Pilot applications are presented for the finite-field calculation of molecular magnetizabilities, hypermagnetizabilities, and nuclear magnetic resonance shielding constants, focusing on the impact of current-density functionals on the accuracy of the results. Existing current-density functionals based on the gauge-invariant vorticity are tested and found to be sensitive to numerical details of their implementation. Furthermore, when appropriately regularized, the resulting magnetic properties show no improvement over standard density-functional results. An advantage of the present implementation is the ability to apply density-functional theory to molecules in very strong magnetic fields, where the perturbative approach breaks down. Comparison with high accuracy full-configuration-interaction results show that the inadequacies of current-density approximations are exacerbated with increasing magnetic field strength. Standard density-functionals remain well behaved but fail to deliver high accuracy. The need for improved current-dependent density-functionals, and how they may be tested using the presented implementation, is discussed in light of our findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of a weakly 3-D equilibrium on ideal magnetohydrodynamic instabilities

The effect of a small three-dimensional equilibrium distortion on an otherwise axisymmetric configuration is shown to be destabilizing to ideal magnetohydrodynamic modes. The calculations assume that the 3-D fields are weak and that shielding physics is present so that no islands appear in the resulting equilibrium. An eigenfunction that has coupled harmonics of different toroidal mode number is constructed using a perturbation approach. The theory is applied to the case of tokamak H-modes with shielded resonant magnetic perturbations (RMPs) present indicating RMPs can be destabilizing to intermediate-n peeling-ballooning modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relativistic theory of nuclear spin-rotation tensor with kinetically balanced rotational London orbitals

Both kinetically balanced (KB) and kinetically unbalanced (KU) rotational London orbitals (RLO) are proposed to resolve the slow basis set convergence in relativistic calculations of nuclear spin-rotation (NSR) coupling tensors of molecules containing heavy elements [Y. Xiao and W. Liu, J. Chem. Phys. 138, 134104 (2013)]. While they perform rather similarly, the KB-RLO Ansatz is clearly preferred as it ensures the correct nonrelativistic limit even with a finite basis. Moreover, it gives rise to the same “direct relativistic mapping” between nuclear magnetic resonance shielding and NSR coupling tensors as that without using the London orbitals [Y. Xiao, Y. Zhang, and W. Liu, J. Chem. Theory Comput. 10, 600 (2014)].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

QSHS: an axion dark matter resonant search apparatus

We describe a resonant cavity search apparatus for axion dark matter constructed by the quantum sensors for the hidden sector collaboration. The apparatus is configured to search for QCD axion dark matter, though also has the capability to detect axion-like particles, dark photons, and some other forms of wave-like dark matter. Initially, a tuneable cylindrical oxygen-free copper cavity is read out using a low noise microwave amplifier feeding a heterodyne receiver. The cavity is housed in a dilution refrigerator (DF) and threaded by a solenoidal magnetic field, nominally 8 T. The apparatus also houses a magnetic field shield for housing superconducting electronics, and several other fixed-frequency resonators for use in testing and commissioning various prototype quantum electronic devices sensitive at a range of axion masses in the range 2.0–40 μ eV c -2 . The apparatus as currently configured is intended as a test stand for electronics over the relatively wide frequency band attainable with TM 010 the cavity mode used for axion searches. We present performance data for the resonator, DF, and magnet, and plans for the first science run.

Physics - Physics of elementary particles and fiel↗

Micro-aligned 1 Tesla Solenoid for High-energy Bunched-beam Electron Cooling

Electron cooling of ion beams requires precise alignment of the electron beam with the equilibrium trajectory of the ion bunch. In magnetized cooling the cooling rate is enhanced by transverse confinement of each electron on a magnetic line of force. The magnetic lines of force must therefore be aligned with the ion bunch trajectory everywhere along the extent of the solenoid. For the parameters required for JLEIC, a solenoid with bore field ~1 T, length ~30 m, and rms alignment of ~micro-radian is required. Such alignment has never been accomplished. The design of a micro-aligned solenoid is presented. A gap-separated stack of thin steel washers is located along the bore of the solenoid. The flux plate stack shields transverse magnetic fields from the interior, so that axial alignment is enhanced by a factor of ~10.

43 PARTICLE ACCELERATORS↗

Single Pixel Characterization of X-Ray TES Microcalorimeter Under AC Bias at MHz Frequencies

In this paper we present the progress made at SRON in the read-out of GSFC x-ray transition-edge sensor (TES) micro-calorimeters in the frequency domain. The experiments reported so far, whose aim was to demonstrate an energy resolution of 2eV at 6 keV with a TES acting as a modulator, were carried out at frequencies below 700 kHz using a standard flux locked loop (FLL) SQUID read-out scheme. The TES read-out suffered from the use of sub-optimal circuit components, large parasitic inductances, low quality factor resonators and poor magnetic field shielding. We have developed a novel experimental set-up, which allows us to test several read-out schemes in a single cryogenic run. In this set-up, the TES pixels are coupled via superconducting transformers to 18 high-Q lithographic LC filters with resonant frequencies ranging between 2 and 5 MHz. The signal is amplified by a two-stage SQUID current sensor and baseband feedback is used to overcome the limited SQUID dynamic range. We study the single pixel performance as a function of TES bias frequency, voltage and perpendicular magnetic field.

Gottardi, L.↗

Parity violation in nuclear magnetic resonance frequencies of chiral tetrahedral tungsten complexes NWXYZ (X, Y, Z = H, F, Cl, Br or I)

Density functional theory within the two-component quasi-relativistic zeroth-order regular approximation (ZORA) is used to predict parity violation shifts in {sup 183}W nuclear magnetic resonance shielding tensors of chiral, tetrahedrally bonded tungsten complexes of the form NWXYZ (X, Y, Z = H, F, Cl, Br or I), as well as for the heavier systems NWHAtF and NWH(117)F for comparison. The calculations reveal that sub-mHz accuracy is required to detect such tiny effects in this class of compounds, and that parity violation effects are very sensitive to the choice of ligands.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experiments to Quantify the Shielding Efficacy of Materials to be Implemented for Portable Shielding Enclosures that Adequately Mitigate EMI from Lighting Attachment Events

Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling” regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of ~33 kA and a risetime of 1.4 μs is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.

61 RADIATION PROTECTION AND DOSIMETRY↗