Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Net energy gain in direct laser acceleration due to enhanced dephasing induced by an applied magnetic field

Even in the situation where an electron interacts with a single plane wave, the well-known dynamical adiabaticity can be broken when an applied magnetic field is present, which will act to increase the dephasing rate of the electron during the interaction. Here we demonstrate this for the case where there is a uniform static magnetic field which is oriented either parallel or perpendicular to the electric field of the incident plane wave, and perpendicular to the direction of its propagation. The described energy gain phenomenon has direct relevance to laser-plasma interactions that involve external magnetic fields generated by laser-driven capacitor coils.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Supersonic Gas Injector for Plasma Fueling in the National Spherical Torus Experiment

A supersonic gas injector (SGI) has been developed for fueling and diagnostic applications on the National Spherical Torus Experiment (NSTX). It is comprised of a graphite converging-diverging Laval nozzle and a commercial piezoelectric gas valve mounted on a movable probe at a low-field-side midplane port location. Also mounted on the probe is a diagnostic package: a Langmuir probe, two thermocouples, and five pick-up coils for measuring toroidal, radial, vertical magnetic field components and magnetic fluctuations at the location of the SGI tip. The SGI flow rate is up to 33.25 Pa m 3 / (1.75 × 10 22 euterium particles/s), comparable to conventional NSTX gas injectors. The nozzle operates in a pulsed regime at room temperature and a reservoir gas pressure up to 665 kPa (5000 Torr). The deuterium jet Mach number of about 4 and the divergence half-angle of 5 to 25 deg have been measured in laboratory experiments simulating the NSTX environment. Reliable operation of the SGI and all mounted diagnostics at distances 0.01 to 0.20 m from the plasma separatrix has been demonstrated in NSTX experiments. The SGI has been used for fueling of ohmic and 2- to 4-MW neutral beam injection–heated L- and H-mode plasmas. Fueling efficiency in the range 0.1 to 0.3 has been obtained from the plasma electron inventory analysis. In conclusion, the SGI-fueling–based plasma discharge scenarios enabling better density control have been developed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

120-mm supercondcting quadrupole for interaction regions of hadron colliders

Magnetic and mechanical designs of a Nb{sub 3}Sn quadrupole magnet with 120-mm aperture suitable for interaction regions of hadron colliders are presented. The magnet is based on a two-layer shell-type coil and a cold iron yoke. Special spacers made of a low-Z material are implemented in the coil mid-planes to reduce the level of radiation heat deposition and radiation dose in the coil. The quadrupole mechanical structure is based on aluminum collars supported by an iron yoke and a stainless steel skin. Magnet parameters including maximum field gradient and field harmonics, Nb3Sn coil pre-stress and protection at the operating temperatures of 4.5 and 1.9 K are reported. The level and distribution of radiation heat deposition in the coil and other magnet components are discussed.

43 PARTICLE ACCELERATORS↗

Final Technical Report for DOE DE-FG02-05ER54831 "Laboratory Studies of Dynamos."

Laboratory Studies of Dynamos: Executive Summary. The self-generation of magnetic fields by astrophysical bodies like planets, stars, accretion disks, galaxies, and even galaxy clusters arises due to a mechanism referred to as a homogeneous dynamo. It is quite simple to demonstrate the generation of a magnetic fi eld from a rotating copper disk coupled with a coil of wire, a device known as the homopolar dynamo. The device works like a magnetic fi eld ampli er with a feedback circuit: the differential rotation of a metal disk past an infinitesimally small seed magnetic field induces currents in the disk which, when coupled to a coil winding, can amplify the field until it becomes strong enough to slow the rotation of the disk. What is remarkable is that the same type of circuit may be achieved in a flowing conducting fluid such as a liquid metal in the case of planetary dynamos or a plasma in the case of astrophysical dynamos. The complexity of describing planetary and stellar dynamos despite their ubiquity and the plethora of observational data from the Earth and the Sun motivates the demonstration of a laboratory homogenous dynamo. To create a homogenous dynamo, one first needs a su fficiently large, fast flow of a highly conducting fluid that the velocity shear in the fluid can bend magnetic field lines. With a high Rm-flow, the magnetic fi eld can be ampli ed by the stretching action provided by di fferential rotation. The other critical ingredient is a flow geometry that provides feedback so that the ampli ed eld reinforces the initial in nitesimal seed field - a mechanism that recreates the feedback provided by the coil of wire in the homopolar dynamo. In the Madison Dynamo Experiment, this combination of magnetic ampli cation and feedback is feasible in the simple geometry of two counter-rotating helical vortices in a 1 meter-diameter spherical vessel lled with liquid sodium. For an optimal helical pitch of the flow the threshold for exciting a dynamo is predicted from laminar flow modeling to be at peak flow speeds of 5 m/s. Liquid metals tend to have viscosities similar to that of water yielding inviscid flows. Whereas the timescale for the dynamo instability is on the resistive dissipation time, the timescale for hydrodynamic instability of the shear layer is quite short meaning that the shear layer required to generate the magnetic eld is broken up by Kelvin-Helmholtz instabilities. The eddies generated by large-scale flow drive instabilities at progressively smaller scale giving rise to a cascade of turbulent eddies driven at the largest scale of the experiment. The major contribution of the Madison Dynamo Experiment has been quantifying the role this turbulence plays in the generation of magnetic elds. Overall, the Madison Dynamo Experiment has now operated for about 1 decade and carried out experiments related to magnetic fi eld generation by turbulent flows of liquid metal. The principle thrust of research and indeed the main scienti fic outcomes are related to how turbulent flows create and transport magnetic fi elds.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bioinspired aligned magnetic features in aerogels for humidity sensing

Many natural plant tissues, such as pinecones, utilize structures to transduce changes in humidity into movement or strain. These often employ layered structures with aligned features in order to create differential stress across the material as different portions swell at different rates. Here, by replicating these types of structures in synthetic materials we can create structures that respond to humidity in a similar manner. Taking these aligned features as inspiration, silica aerogels with tailored humidity reactive properties were created. This behavior was achieved by creating aligned features in these aerogels using a Helmholtz coil to produce a uniform magnetic field that aligned ferrofluid droplets into chains and needle like features. These magnetite-based structures were shown to retain their superparamagnetic properties, allowing them to easily be removed from the aerogels, leaving a large number of aligned channels. Aerogels with the removed needles experienced significantly different strains than both unmodified aerogels and aerogels with the aligned features still in place. Aerogels with these tunable aligned features could be used in humidity sensors that can transduce changes in humidity into strain and could be used in applications such as volatile organic compound capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DEIMOS: A beamline dedicated to dichroism measurements in the 350–2500 eV energy range

The DEIMOS (Dichroism Experimental Installation for Magneto-Optical Spectroscopy) beamline was part of the second phase of the beamline development at French Synchrotron SOLEIL (Source Optimisée de Lumière à Energie Intermédiaire du LURE) and opened to users in March 2011. It delivers polarized soft x-rays to perform x-ray absorption spectroscopy, x-ray magnetic circular dichroism, and x-ray linear dichroism in the energy range 350–2500 eV. The beamline has been optimized for stability and reproducibility in terms of photon flux and photon energy. The main end-station consists in a cryo-magnet with 2 split coils providing a 7 T magnetic field along the beam or 2 T perpendicular to the beam with a controllable temperature on the sample from 370 K down to 1.5 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quasi-linear toroidal simulations of resonant magnetic perturbations in eight ITER H-mode scenarios

Abstract Both linear and quasi-linear aspects of the plasma response to the resonant magnetic perturbation (RMP) field are numerically investigated for various H-mode scenarios in ITER, covering the pre-fusion power operation and the fusion power operation phases. Linear response computations for eight ITER scenarios, with varying plasma current and toroidal magnetic field, reveal that the best coil current phasing for controlling the type-I edge localized modes (ELMs) scales roughly linearly with the edge safety factor. The coil phasing is defined as the relative toroidal phase of the coil currents between different rows, for a given toroidal harmonic. Quasi-linear initial value simulation, which is the focus of the present study, shows that application of the n = 3 ( n is the toroidal mode number) RMP field has a minimum side effect on the plasma core momentum confinement but potentially a large effect on the global particle transport. Generally, the RMP field with the best (worst) coil phasing for ELM control produces the strongest (weakest) effect on the plasma edge flow and the overall density. This robustly holds for all eight ITER scenarios. Consequently, in order to minimize the RMP induced side effects while achieving ELM control (suppression) in ITER, a compromise is necessary in choosing the coil current configuration.

Physics↗

Modeling of Macroscopic Dynamics in Three-Dimensional Plasma Configurations (Final Technical Report)

A numerical simulation-based study to investigate the stability properties of inherently three-dimensional plasma magnetic configurations is presented. These configurations, called stellarators and heliotrons, use external helical coils to provide the twisting magnetic field that is required to confine ionized plasma particles. In contrast to the tokamak configuration, which nominally has the property of axisymmetry, electrical current does not need to be induced in stellarator and heliotron plasma. Experiments have shown that these three-dimensional configurations are remarkably robust to macroscopic instability, even when driven to relatively high levels of plasma pressure. Our understanding of how the plasma is able to withstand macroscopic instability will be enhanced by the work proposed here. The effort will generalize existing numerical modeling capability, and it will apply the new capability to model macroscopic dynamics in these three-dimensional configurations. The development work has been applied to the NIMROD simulation code (https://nimrodteam.org) that was originally based on axisymmetric problem domains. It has been generalized to accommodate the three-dimensional shaping of the plasma volume in stellarators and heliotrons. Its use of equilibrium data has also been generalized, and the implementation allows different numerical representation of the magnetic field. Analysis has been performed to inform the selection of numerical methods, and a method to accelerate the iterative solution of the necessary algebraic systems has been developed and implemented. Verification of the new NIMSTELL code on benchmark problems has also been an important part of the effort.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Dynamically Polarized Solid Target for CLAS12

The 12 GeV physics program in Hall B at Jefferson Lab will be centered on the newly commissioned, high acceptance spectrometer CLAS12 and will utilize a variety of nuclear targets, including a dynamically polarized solid target for experiments on longitudinally polarized protons, deuterons, and lithium nuclei. The target, under construction in a collaborative effort between the Jefferson Lab Target Group, Christopher Newport University, Old Dominion University, and the University of Virginia, is designed with a number of innovative features. These include multiple target cells for reduced systematic uncertainties, internal superconducting shim coils to adjust the polarizing magnetic field, and a 1 K evaporation refrigerator with an integrated load lock system for the target samples. The current status of the system's design, construction, and various R&D efforts are described.

Keith, Christopher↗

The SAS-3 attitude control system

SAS-3 uses a reaction wheel to provide torque to control the spin rate. If the wheel speed becomes too great or too small, it must be restored to its nominal rate by momentum dumping which is done by magnetic torquing against the earth's magnetic field by the satellite's magnetic coils. A small rate-integrating gyro is used to sense the spin rate so that closed loop control of the spin rate can be achieved. These various systems are described in detail including the reaction wheel system, the gyro system, along with control modes (spin rate control and the star lock mode).

Mobley, F. F.↗

A spaceborne superconducting gravity gradiometer for mapping the earth's gravity field

The principles of a satellite gravity gradiometer system which measures all five independent components of the gravity gradient tensor with a sensitivity of 0.001 E/Hz to the 1/2 power or better, are analyzed, and the status of development of the system is reviewed. The superconducting gravity gradiometer uses sensitive superconducting accelerometers, each of which are composed of a weakly suspended superconducting proof mass, a superconducting magnetic transducer, and a low-noise superconducting magnetometer. The magnetic field produced by the transducer coils is modulated by the motion of the proof mass and detected by the magnetometer. A combination of two or four of such accelerometers with proper relative orientation of sensitive axes results in an in-line or a cross component gravity gradiometer.

Paik, H. J.↗

Development of LC-13C NMR

This study involves the development of C-13 nuclear resonance as an on-line detector for liquid chromatography (LC-C-13 NMR) for the chemical characterization of aviation fuels. The initial focus of this study was the development of a high sensitivity flow C-13 NMR probe. Since C-13 NMR sensitivity is of paramount concern, considerable effort during the first year was directed at new NMR probe designs. In particular, various toroid coil designs were examined. In addition, corresponding shim coils for correcting the main magnetic field (B sub 0) homogeneity were examined. Based on these initial probe design studies, an LC-C-13 NMR probe was built and flow C-13 NMR data was obtained for a limited number of samples.

Dorn, H. C.↗

CRRES plasma wave experiment

The CRRES plasma wave experiment is designed to provide information on the plasma wave environment and the total plasma density in the Earth's radiation belts and throughout the CRRES orbit. This information is valuable both for studying the naturally occurring wave-particle interactions affecting the plasma and particle environment in the plasmasphere and magnetosphere as well as for studying the chemical releases. The electric field sensors for this instrument consist of two long electric dipole antennas (about 100 m tip-to-tip), and the magnetic field sensor is a search coil magnetometer mounted at the end of a 6-m boom. The instrument has a 14-channel spectrum analyzer covering the frequency range from 5.6 Hz to 10 kHz, and a 128-step sweep frequency receiver covering the frequency range from 100 Hz to 400 kHz.

Anderson, Roger R.↗

Magnetic power piston fluid compressor

A compressor with no moving parts in the traditional sense having a housing having an inlet end allowing a low pressure fluid to enter and an outlet end allowing a high pressure fluid to exit is described. Within the compressor housing is at least one compression stage to increase the pressure of the fluid within the housing. The compression stage has a quantity of magnetic powder within the housing, is supported by a screen that allows passage of the fluid, and a coil for selectively providing a magnetic field across the magnetic powder such that when the magnetic field is not present the individual particles of the powder are separated allowing the fluid to flow through the powder and when the magnetic field is present the individual particles of the powder pack together causing the powder mass to expand preventing the fluid from flowing through the powder and causing a pressure pulse to compress the fluid.

Gasser, Max G.↗

Non-Contact Thrust Stand Calibration Method for Repetitively-Pulsed Electric Thrusters

A thrust stand calibration technique for use in testing repetitively-pulsed electric thrusters for in-space propulsion has been developed and tested using a modified hanging pendulum thrust stand. In the implementation of this technique, current pulses are applied to a solenoidal coil to produce a pulsed magnetic field that acts against the magnetic field produced by a permanent magnet mounted to the thrust stand pendulum arm. The force on the magnet is applied in this non-contact manner, with the entire pulsed force transferred to the pendulum arm through a piezoelectric force transducer to provide a time-accurate force measurement. Modeling of the pendulum arm dynamics reveals that after an initial transient in thrust stand motion the quasisteady average deflection of the thrust stand arm away from the unforced or zero position can be related to the average applied force through a simple linear Hooke s law relationship. Modeling demonstrates that this technique is universally applicable except when the pulsing period is increased to the point where it approaches the period of natural thrust stand motion. Calibration data were obtained using a modified hanging pendulum thrust stand previously used for steady-state thrust measurements. Data were obtained for varying impulse bit at constant pulse frequency and for varying pulse frequency. The two data sets exhibit excellent quantitative agreement with each other as the constant relating average deflection and average thrust match within the errors on the linear regression curve fit of the data. Quantitatively, the error on the calibration coefficient is roughly 1% of the coefficient value.

Wong, Andrea R.↗

Normally-Closed Zero-Leak Valve with Magnetostrictive Actuator

A non-pyrotechnic, normally-closed, zero-leak valve is a replacement for the pyrovalve used for both in-space and launch vehicle applications. The valve utilizes a magnetostrictive alloy for actuation, rather than pyrotechnic charges. The alloy, such as Terfenol-D, experiences magnetostriction, i.e. a gross elongation, when exposed to a magnetic field. This elongation fractures a parent metal seal, allowing fluid flow through the valve. The required magnetic field is generated by redundant coils that are isolated from the working fluid.

Ramspacher, Daniel J.↗

EMAT enhanced dispersion of particles in liquid

Particulate matter is dispersed in a fluid material. A sample including a first material in a fluid state and second material comprising particulate matter are placed into a chamber. The second material is spatially dispersed in the first material utilizing EMAT force. The dispersion process continues until spatial distribution of the second material enables the sample to meet a specified criterion. The chamber and/or the sample is electrically conductive. The EMAT force is generated by placing the chamber coaxially within an induction coil driven by an applied alternating current and placing the chamber and induction coil coaxially within a high field magnetic. The EMAT force is coupled to the sample without physical contact to the sample or to the chamber, by another physical object. Batch and continuous processing are utilized. The chamber may be folded within the bore of the magnet. Acoustic force frequency and/or temperature may be controlled.

36 MATERIALS SCIENCE↗