Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Liquid flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Flow behavior in liquid molding

The liquid molding (LM) process for manufacturing polymer composites with structural properties has the potential to significantly lower fabrication costs and increase production rates. LM includes both resin transfer molding and structural reaction injection molding. To achieve this potential, however, the underlying science base must be improved to facilitate effective process optimization and implementation of on-line process control. The National Institute of Standards and Technology (NIST) has a major program in LM that includes materials characterization, process simulation models, on-line process monitoring and control, and the fabrication of test specimens. The results of this program are applied to real parts through cooperative projects with industry. The key feature in the effort is a comprehensive and integrated approach to the processing science aspects of LM. This paper briefly outlines the NIST program and uses several examples to illustrate the work.

Hunston, D.↗

Influence of Two-Phase Thermocapillary Flow on Cryogenic Liquid Retention in Microscopic Pores

Previous experiments indicate that the bubble point pressure of spacecraft liquid hydrogen acquisition devices is reduced substantially when the ullage is pressurized with heated hydrogen vapor. The objective is to determine whether the two-phase thermocapillary convection arising from thermodynamic non-equilibrium along the porous surfaces of such devices could lead to this observed degradation in retention performance. We also examine why retention capability appears to be unaffected by pressurization with heated helium or direct heating through the porous structure. Computational assessments based on coupled solution of the flowfield and liquid free surface indicate that for highly wetting fluids in small pores, dynamic pressure and vapor recoil dictate surface morphology and drive meniscus deformation. With superheating, the two terms exert the same influence on curvature and promote mechanical equilibrium, but with subcooling, the pressure distribution produces a suction about the pore center-line that degrades retention. This result points to thermocapillary-induced deformation arising from condensation as the cause for retention loss. It also indicates that increasing the level of non-equilibrium by reducing accommodation coefficient restricts deformation and explains why retention failure does not occur with direct screen heating or helium pressurization.

Schmidt, G. R.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted simultaneously with native fluorescence spectroscopy to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted simultaneously with native fluorescence spectroscopy to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

The use of liquid crystals for surface flow visualization

The use of shear-sensitive liquid crystals has become an established technique for diagnostic flow visualization. This technique has been demonstrated to illustrate laminar boundary-layer transition, laminar bubbles, shocks, and separation in flight and wind-tunnel environments. Typical results demonstrate the range of flow features which can be illustrated and some of the challenges and pitfalls which must be addressed. A few remaining issues are discussed which should be resolved to develop this technique to full maturity.

Smith, Stephen C.↗

Computation of turbulent flow in a thin liquid layer of fluid involving a hydraulic jump

Numerically computed flow fields and free surface height distributions are presented for the flow of a thin layer of liquid adjacent to a solid horizontal surface that encounters a hydraulic jump. Two kinds of flow configurations are considered: two-dimensional plane flow and axisymmetric radial flow. The computations used a boundary-fitted moving grid method with a k-epsilon model for the closure of turbulence. The free surface height was determined by an optimization procedure which minimized the error in the pressure distribution on the free surface. It was also checked against an approximate procedure involving integration of the governing equations and use of the MacCormack predictor-corrector method. The computed film height also compared reasonably well with previous experiments. A region of recirculating flow was found to be present adjacent to the solid boundary near the location of the jump, which was caused by a rapid deceleration of the flow.

Rahman, M. M.↗

TEMPO allegro: liquid catholyte redoxmers for nonaqueous redox flow batteries

Redoxmers are organic active molecules storing energy in redox flow batteries (RFBs). Liquid redoxmers represent an extreme scenario where maximum concentration may be achieved by minimizing supporting solvents, thus maximizing the energy density of RFBs. Herein, a series of (2,2,6,6-tetramethylpiperidin-1-yl)oxyl (TEMPO)-based high potential (catholyte) liquid redoxmers, TEMPO-EG1, TEMPO-EG2, and TEMPO-EG3, were developed by incorporating polyethylene glycol (PEG) chains. Such modifications not only afford dramatic physical changes from solid to liquid and full miscibility in acetonitrile, but also impact the redox behavior. DFT calculations indicate that the incorporated PEG chains impact the charge distribution, which may account for the electrochemical changes. Importantly, compared to our previous liquid catholytes, the new redoxmers exhibit lower viscosity, which is desired for enhancing high concentration cycling performance. Furthermore, by using a hybrid flow cell, TEMPO-EG1 demonstrated more than 70% capacity retention over 100 cycles at 0.1 M and 66% capacity retention at 0.5 M, affording excellent cyclability at various concentrations. The study exemplifies how molecular engineering tuned the rheological properties of redoxmers, such as viscosity, to improve the high concentration cycling performance of RFBs, which may represent a promising avenue for a high energy density and low-cost flow battery system.

25 ENERGY STORAGE↗

Bubble Transport through a Porous Lattice with an Applied Inlet Flow

Within gas-evolving electrochemical systems, bubbles negatively impact performance by covering electrode active sites for reactions, blocking electric field lines, and obstructing liquid electrolyte flow causing pressure buildup. Recent additive manufacturing advances have enabled tuned porous electrode microstructures to be created, but producing systems that maximize electrochemical throughput and minimize bubble impact remains challenging. Thus, improved physical understanding of and modeling capabilities for bubble behavior are critical to improve electrolyzer design. To address this need, this study examines rising stage bubbles within a lattice with an applied liquid flow—an underexplored regime that strongly influences an electrochemical bubble’s fate. Notably, theoretical predictions and resolved bubble simulations are complemented by experiments from a 3D-printed visualization cell that matches the simulation geometry. The minimum threshold flow rate to achieve bubble breakthrough is found to be larger for higher porosities and for smaller bubbles. Different-sized bubbles decrease expected electrochemical performance in different ways; smaller bubbles tend to stay stuck but cover less solid surface, while larger bubbles more readily break through but cover more surface while in the lattice. The bubble trajectory, deformation, and contact area provide insight into these different behaviors. These findings provide design guidelines toward creating more effective electrolyzers.

Guo, Jack [Lawrence Livermore National Laboratory ↗

Prediction of gas-liquid two-phase flow regime in microgravity

An attempt is made to predict gas-liquid two-phase flow regime in a pipe in a microgravity environment through scaling analysis based on dominant physical mechanisms. Simple inlet geometry is adopted in the analysis to see the effect of inlet configuration on flow regime transitions. Comparison of the prediction with the existing experimental data shows good agreement, though more work is required to better define some physical parameters. The analysis clarifies much of the physics involved in this problem and can be applied to other configurations.

Lee, Jinho↗