Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Peripheral Stent Thrombosis Leading to Acute Limb Ischemia and Major Amputation: Incidence and Risk Factors in the Aortoiliac and Femoropopliteal Arteries

PurposeTo report the real-world incidence and risk factors of stent thrombosis in the aortoiliac and femoropopliteal arteries in case of bare nitinol stent (BNS) or covered nitinol stent (CNS) placement from a single-centre retrospective audit.Materials and MethodsMedical records of consecutive patients treated with peripheral stent placement for claudication or critical limb ischemia were audited for definite stent thrombosis defined as imaging confirmed stent thrombosis that presented as acute limb-threatening ischemia. Cases were stratified between aortoiliac and femoropopliteal anatomy. Cox regression analysis was employed to adjust for baseline clinical and procedural confounders and identify predictors of stent thrombosis and major limb loss.Results256 patients (n = 277 limbs) were analysed over a 5-year period (2009–2014) including 117 aortoiliac stents (34 CNS; 12.8 ± 5.0 cm and 83 BNS; 7.8 ± 4.0 cm) and 160 femoropopliteal ones (60 CNS; 21.1 ± 11.0 cm and 100 BNS; 17.5 ± 11.9 cm). Median follow-up was 1 year. Overall stent thrombosis rate was 6.1% (17/277) after a median of 43 days (range 2–192 days) and affected almost exclusively the femoropopliteal segment (12/60 in the CNS cohort vs. 4/100 in the BNS; p = 0.001). Annualized stent thrombosis rates (per 100 person-years) were 12.5% in case of CNS and 1.4% in case of BNS (HR 6.3, 95% CI 2.4–17.9; p = 0.0002). Corresponding major amputations rates were 8.7 and 2.5%, respectively (HR 4.5, 95% CI 2.7–27.9; p = 0.0006). On multivariable analysis, critical leg ischemia and CNS placement were the only predictors of stent thrombosis. Diabetes, critical leg ischemia, femoropopliteal anatomy, long stents and CNS were independent predictors of major amputations.ConclusionsPlacement of long femoropopliteal covered nitinol stents is associated with an increased incidence of acute stent thrombosis and ensuing major amputation. Risks are significantly lower in the aortoiliac vessels and with use of bare nitinol stents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reliable Thermoelectric Module Design under Opposing Requirements from Structural and Thermoelectric Considerations

Structural reliability of thermoelectric generation (TEG) systems still remains an issue especially for applications such as large scale industrial or automobile exhaust heat recovery where a TEG system is subject to dynamic loads and thermal cycling. Traditional thermoelectric (TE) system design and optimization techniques, focused on performance alone, could result in designs that may fail during operation as the geometric requirements for optimal performance (especially the power) are often in conflict with the requirements for mechanical reliability. This study focused on reducing the thermomechanical stresses in a TEG system without compromising the optimized system performance. Finite element simulations were carried out to study the effect of TE element (leg) geometry such as the leg length and cross-sectional shape under constrained material volume requirements. Results indicated that the element length has a major influence on the element stresses whereas the regular cross-sectional shapes have minor influence. Additionally, the impact of TE element stresses on the mechanical reliability is evaluated with the brittle material failure theory based on Weibull analysis. An alternate couple configuration that relies on the industry practice of redundant element design is investigated. Results showed that the alternate configuration considerably reduced the TE element and metallization stresses thereby enhancing the structural reliability with little trade-off in the optimized performance. The proposed alternate configuration could serve as a potential design modification for improving the reliability of systems optimized for thermoelectric performance.

36 MATERIALS SCIENCE↗

Load Mitigation on Floating Offshore Wind Turbines with Advanced Controls and Tuned Mass Dampers

General Electric, the National Renewable Energy Laboratory (NREL), the University of Massachusetts Amherst (UMass), and Glosten have recently completed a US Department of Energy (DOE)-funded research program to study technologies for mitigating loads on floating offshore wind turbines through the use of advanced turbine controls and tuned mass dampers (TMDs). The analysis was based upon the Glosten PelaStar tension leg platform (TLP) with GE Haliade 150 turbine, a system developed in a previous front end engineering design (FEED) study funded by the Energy Technology Institute (ETI) in the UK. The platform was designed for the WaveHub wave energy research site, with a mean water depth of 59-m. Loads were analyzed by running time-domain simulations in four 50-year return period (50-YRP) ultimate load state (ULS) conditions and 77 fatigue load state (FLS) environmental conditions. In 50-YRP conditions advanced controls are not active. The influence of TMDs on ULS loads have been reported previously (Park et al. [2]). In FLS conditions advanced controls and TMDs afford dramatic reductions in fatigue damage, offering the potential of significant savings in tower structural requirements. Simulations in turbine idling conditions were run in OrcaFlex, and simulations in operating conditions were run in FAST. Simulations were run with a baseline turbine controller, representative of the current state of the art, and an advanced controller developed by NREL to use collective and individual blade pitch control to maintain rotor speed and reduce tower loads. UMass developed a number of TMD types, with varying system configurations, including passive nonlinear dampers and semi-actively controlled dampers with an inverse velocity groundhook control algorithm. Loads and accelerations in FLS conditions were evaluated on the basis of damage equivalent loads (DELs), and fatigue damage was computed by Miner's summations of stress cycles at the tower base. To study sensitivity to water depth, loads were analyzed at both the 59-m WaveHub depth and a more commercially realistic depth of 100 m. TMDs reduce fatigue damage at the tower-column interface flange by up to 52% in 59-m water depth and up to 28% in 100 m water depth. Advanced controls reduce fatigue damage at the tower-column flange by up to 22% in 59-m water depth and up to 40% in 100 m water depth. The most effective load-mitigation strategy is combining advanced controls with TMDs. This strategy affords a 71% reduction in fatigue damage in both 59-m and 100-m water depths.

17 WIND ENERGY↗

A quantification strategy for missing bone mass in case of osteolytic bone lesions

Purpose: Most of the patients who died of breast cancer have developed bone metastases. To understand the pathogenesis of bone metastases and to analyze treatment response of different bone remodeling therapies, preclinical animal models are examined. In breast cancer, bone metastases are often bone destructive. To assess treatment response of bone remodeling therapies, the volumes of these lesions have to be determined during the therapy process. The manual delineation of missing structures, especially if large parts are missing, is very time-consuming and not reproducible. Reproducibility is highly important to have comparable results during the therapy process. Therefore, a computerized approach is needed. Also for the preclinical research, a reproducible measurement of the lesions is essential. Here, the authors present an automated segmentation method for the measurement of missing bone mass in a preclinical rat model with bone metastases in the hind leg bones based on 3D CT scans. Methods: The affected bone structure is compared to a healthy model. Since in this preclinical rat trial the metastasis only occurs on the right hind legs, which is assured by using vessel clips, the authors use the left body side as a healthy model. The left femur is segmented with a statistical shape model which is initialised using the automatically segmented medullary cavity. The left tibia and fibula are segmented using volume growing starting at the tibia medullary cavity and stopping at the femur boundary. Masked images of both segmentations are mirrored along the median plane and transferred manually to the position of the affected bone by rigid registration. Affected bone and healthy model are compared based on their gray values. If the gray value of a voxel indicates bone mass in the healthy model and no bone in the affected bone, this voxel is considered to be osteolytic. Results: The lesion segmentations complete the missing bone structures in a reasonable way. The mean ratiov{sub r}/v{sub m} of the reconstructed bone volume v{sub r} and the healthy model bone volume v{sub m} is 1.07, which indicates a good reconstruction of the modified bone. Conclusions: The qualitative and quantitative comparison of manual and semi-automated segmentation results have shown that comparing a modified bone structure with a healthy model can be used to identify and measure missing bone mass in a reproducible way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An innovative SR-WEC for a market-disruptive LCOE

The objective of DE-EE0008630: An innovative SR-WEC for a market-disruptive LCOE was to develop and test a scaled prototype of the Surface-Riding Wave Energy Converter that can result in a market-disruptive Levelized Cost of Energy by a combination of an extended operating window, substantially lowered cost and amplified average power output by simple optimum control. Initially conceptualized as a floating linear electrical generator (LEG), the SR-WEC evolved into an intermediate-scale version where multiple LEGs were mounted on a floating cylindrical body, driven by the need to enhance scalability and improve power performance.

16 TIDAL AND WAVE POWER↗

A numerical and experimental study on weld lines formation and strength in extrusion

In this work, we present a study on numerical and experimental approaches aiming to improve our understanding about the relation between the flow conditions and the strength of weld lines in extruded profiles. For this purpose, a prototype extrusion die that comprises a movable spider leg is used to produce tapes under different flow conditions, by varying the location of the spider leg and the flow rate. The same case studies are numerically studied, considering a viscoelastic Giesekus constitutive model. The numerical results are then investigated to identify potential relationships between the flow conditions, in which the weld lines are formed, with the strength of the weld line experimentally characterized. The results obtained allow identifying a clear correlation between the flow conditions and the weld‐line strength. POLYM. ENG. SCI., 58:249–260, 2018. © 2017 Society of Plastics Engineers

Ferrás, Luís L.↗

A new Wilson line-based action for gluodynamics

We perform a canonical transformation of fields that brings the Yang-Mills action in the light-cone gauge to a new classical action, which does not involve any triple-gluon vertices. The lowest order vertex is the four-point MHV vertex. Higher point vertices include the MHV and $\overline{\mathrm{MHV}}$ vertices, that reduce to the corresponding amplitudes in the on-shell limit. In general, any n -leg vertex has 2 ≤ m ≤ n - 2 negative helicity legs. The canonical transformation of fields can be compactly expressed in terms of path-ordered exponentials of fields and their functional derivative. We apply the new action to compute several tree-level amplitudes, up to 8-point NNMHV amplitude, and find agreement with the standard methods. The absence of triple-gluon vertices results in fewer diagrams required to compute amplitudes, when compared to the CSW method and, obviously, considerably fewer than in the standard Yang-Mills action.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Role of Sexual Dimorphism and Tissue Selection in Ecotoxicological Studies Using the Riparian Spider Tetragnatha elongata

Tetragnathid spiders (Tetragnatha spp.) found in riparian habitats have recently been used as bioindicators of sediment contamination and insect-mediated contaminant flux. We investigated whether sexual dimorphism (size and behavior) influenced the female:male ratio in composite samples, stable isotope ratios (carbon [δ{sup 13}C], nitrogen [δ{sup 15}N]), and Hg concentrations in the southern United States. Additionally, we explored whether biomass for contaminant analysis could be preserved by using the legs of tetragnathids as a surrogate for whole-body δ{sup 13}C and δ{sup 15}N signatures. We found that female tetragnathids were significantly larger than male spiders and represented a larger proportion of spiders collected at all sites. However, despite the difference in size between sexes, no differences in growth dynamics, isotopic signatures (δ{sup 13}C and δ{sup 15}N), or mercury concentrations were observed. It was determined that the leg of a tetragnathid can accurately represent the stable isotope signature of an entire spider.

54 ENVIRONMENTAL SCIENCES↗

An International Round-Robin Study on Thermoelectric Module Testing and Development of Standard Power Generation Modules

An international round-robin study on thermoelectric power generation modules was conducted with nine participating laboratories. Two types of commercially available bismuth telluride modules, 30 mm × 30 mm and 40 mm × 40 mm, were used. A test protocol was followed with five temperature set points from 50°C to 150°C. Graphite sheets were used as thermal interface materials with test pressure at 100 psi (0.69 MPa). The results showed large lab-to-lab variations and the key source of uncertainty for module efficiency was identified as the heat flux measurement. In the meantime, significant uncertainty was also found in maximum electrical power (P max ) measurements. As a result of the round-robin, a “standard module” with 4 × 4 legs on a 20 mm × 20 mm platform was suggested. A skutterudite module and a half-Heusler module were produced with identical geometry and 4 mm × 4 mm × 8 mm legs. All transport properties to calculate the figure-of-merit, zT, were measured from ambient temperature to 500°C. Module performance was measured by two laboratories. Two finite-element-analysis (FEA)-based models were developed independently to simulate and predict the module performance. In conclusion, the standard modules eliminated significant test uncertainties and are aimed at assisting device design and achieving more accurate performance predictions.

Round-robin↗

Spinful fermionic ladders at incommensurate filling: Phase diagram, local perturbations, and ionic potentials

We study the effect of external potential on transport properties of the fermionic two-leg ladder model. The response of the system to a local perturbation is strongly dependent on the ground state properties of the system and especially on the dominant correlations. We categorize all phases and transitions in the model (for incommensurate filling) and introduce “hopping-driven transitions” that the system undergoes as the inter-chain hopping is increased from zero. We also describe the response of the system to an ionic potential. The physics of this effect is similar to that of the single impurity, except that the ionic potential can affect the bulk properties of the system and in particular induce true long range order. -- Highlights: •We study low temperature electronic properties of a two leg ladder. •We find a wide variety of phase transitions as a function of model parameters. •We study the effect of impurities on these models. •Conductance may be very sensitive to the structure of these impurities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CFD modeling of natural circulation in LiCl-KCl molten salt closed loop

Characterizing flow within a molten salt closed-loop system is crucial for assessing system requirements, evaluating performance, and identifying potential flaws. Direct flow measurement using instrumentation is challenging due to extreme environmental conditions and the limitations associated with measuring molten salt flow under natural convection. Here, this study aims to provide comprehensive insights into the thermal-hydraulic behavior of a closed loop, with a particular focus on temperature distribution and velocity prediction. The Computational Fluid Dynamics (CFD) model demonstrated the capability to effectively simulate and predict both temperature distributions and flow velocities within the molten salt loop. The CFD model's predictive capability was validated by its ability to replicate temperature measurements under varying boundary conditions. The analysis revealed that the CFD model tends to underpredict temperatures in the cold leg and overpredict them in the hot leg, highlighting the need for continuous model refinement and acknowledging the limitations of using a steady-state approach. Furthermore, the potential of using external temperature measurements to estimate internal molten salt temperatures and predict flow velocity was explored, revealing that this approach could introduce up to a 5.5% error in flow velocity calculations. Line probes mapping temperature distributions across the tube's cross-section and molten salt provided valuable insights into temperature gradients, emphasizing the need for a thermal conductivity equation for molten salt with lower uncertainty to achieve more accurate temperature predictions of the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Cost-Performance Trade-off in thermoelectric air conditioning system with graded and constant material properties

Thermoelectric (TE) air cooling is a solid-state technology that has the potential to replace conventional vapor compression-based air conditioning. In this paper, we present a detailed system-level modeling for thermoelectric air conditioning system with position-dependent (graded) and constant material properties. Strategies for design optimization of the system are provided in terms of cost-performance trade-off. Realistic convection heat transfer at both sides of the system are taken into account in our modeling. Here, the effects of convection heat transfer coefficients, air flowrate, and thermoelectric material properties are investigated with varying key parameters such as TE leg thickness, module fill factor, and input current. Both constant material properties and graded properties are considered for the TE materials, and they are compared in terms of the degree of cooling, coefficient of performance (COP), and power consumption. For graded materials, we employ one-dimensional finite element methods to solve the coupled electrical and thermal current equations with arbitrary profile of material properties varying with position along the TE legs. We find that graded materials can enhance the degree of cooling, but only at the expense of COP, compared to the case of constant property materials. With constant material properties of ZT = 1 and relatively low electric current, the power consumption of TE coolers can be lower than those of conventional air conditioners at an equivalent cooling capacity. Considering additional advantages such as demand-flexible operation, low noise, and high scalability, thermoelectric cooling could be a competitive technology for future air conditioning applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Compatibility of SiC with ODS FeCrAl in flowing Pb-Li at 600° - 700°C

To establish the maximum operating temperature for the dual coolant lead lithium (DCLL) blanket concept, thermal convection loop (TCL) experiments were conducted for 1000 h with a peak temperature of 700 °C to determine compatibility with commercial eutectic Pb~17at.%Li. Two TCLs were fabricated from alloy APMT (FeCrAlMo) and the baseline TCL experiment contained only APMT specimens. The second TCL experiment exposed more fusion relevant CVD SiC and ODS Fe-10Cr-6Al specimens in the hot and cold legs. In the second experiment, the mass losses were much larger for the ODS FeCrAl specimens and most of the CVD SiC specimens experienced a mass gain as SiC reacted to form an Fe- and Cr-rich carbide reaction product. Dissolved Fe and Cr reacted with the SiC and removing Fe and Cr from the liquid appeared to increase ODS FeCrAl dissolution. Such a dissimilar material interaction appears consistent with thermodynamic calculations. Significant attack at the top of the hot leg in both experiments suggests that the Pb-Li compatibility of FeCrAl alloys is inadequate at 700 °C in a flowing environment and the maximum PbLi temperature is < 675 °C.

36 MATERIALS SCIENCE↗

Validation of the strike point position estimation with the local expansion method for MAST upgrade on the DIII-D tokamak

A local expansion method has been proposed for estimating the strike point position for the advanced divertor configuration on the MAST Upgrade tokamak. The paper discusses the application and assesses the performance of the technique on a long-legged divertor plasma configuration on an operating device - the DIII-D tokamak. A comparison of the spatial location of the outer strike point estimated with the local expansion method against the plasma boundary reconstruction and divertor diagnostics on the DIII-D tokamak is reported. A good agreement with the equilibrium reconstruction and diagnostic data is achieved with respect to estimation of the spatial location of the outer strike point for the long-legged divertor plasma discharge.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Liquid metal compatibility of pre-oxidized FeCrAl in flowing Sn

Here, a flowing Sn thermal convection loop (TCL) experiment was conducted in FeCrAlMo (Kanthal alloy APMT) tubing for 1000 h with a peak temperature of 400 °C. Oxide dispersion strengthened (ODS) Fe-(10–12)Cr-6Al and APMT specimens were exposed and all were pre-oxidized to form an external alumina scale. Unlike static exposures at 400° and 500 °C where pre-oxidation prevented dissolution, large mass losses were observed in the TCL hot leg after the specimens were cleaned in Li. The observed pitting suggests that localized failure of the pre-formed alumina surface oxide caused significant metal loss. Specimen mass gains were not observed on the cold leg implying that mass transfer did not occur and the small levels of Fe and Cr in the Sn after the experiment implies that Sn-rich phases may have formed. Post exposure room temperature tensile testing showed limited impact of the Sn exposure on the 12Cr ODS FeCrAl alloy, comparable to a 1000 h anneal in Ar at 400 °C. These results suggest that pre-oxidation is not sufficient to protect FeCrAl alloys in contact with flowing liquid Sn at 350°-400 °C.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New metastable phases in an oxyborate compound obtained by an evolutionary algorithm and Density Functional Theory

New metastable phases in the Fe homometallic ludwigite compound are obtained and studied using anevolutionary algorithm and Density Functional Theory. Our lowest energy monoclinic structure is identified as P21/m with space group number of 11. This structure evolves towards the monoclinic structureas the result of the spin orbit coupling and a particular zigzag magnetic structure. A zigzag distortion in aclass of three-leg ladders follows similar to the experimental one observed below the transition temper-ature of Tc= 283 K. In this distortion long and short bonds inside rungs alternating in a zigzag way alongthe ladder legs. Furthermore, a new type of zigzag structural ordering is observed in other two low-energy phases analyzed. In this case, the magnetic ordering behaves qualitatively similar to the experimental structure at 82 K, with antiferromagnetically coupled ferromagnetic rungs. Our calculations showthat magnetic symmetry is not favorable for zigzag structural ordering. Finally, structural and magneticproperties will be discussed in comparison with the experimentally known phases.

Vallejo, E.↗

Enhancement of thermoelectric performance in n-type PbTe 1-y Se y by doping Cr and tuning Te:Se ratio

Lead telluride and its alloys have been extensively studied for medium temperature thermoelectric applications due to decent figure-of-merit (ZT) at temperature close to 900 K. However, little emphasis has been given to improve the ZT near room temperature. We report a systematic study of Cr doping in PbTe 1-y Se y with y=0, 0.25, 0.5, 0.75, 0.85, and 1. We found the peak ZT temperature increased with increasing concentration of Se. The highest ZT of ~0.6 at room temperature in Te-rich Cr 0.015 Pb 0.985 Te 0.75 Se 0.25 was obtained due to a lowered thermal conductivity and enhanced power factor resulted from high Seebeck coefficient of about -220 µV K -1 and high Hall mobility ~1120 cm 2 V -1 s -1 at room temperature. A room temperature ZT of ~0.5 and peak ZT of ~1 at about 573–673 K is shown by Se-rich sample Cr 0.01 Pb 0.99 Te 0.25 Se 0.75 . This improvement of the room temperature ZT improved the average ZT over a wide temperature range and could potentially lead to a single leg efficiency of thermoelectric conversion for Te-rich Cr 0.015 Pb 0.985 Te 0.75 Se 0.25 up to ~11% and Se-rich Cr 0.01 Pb 0.99 Te 0.25 Se 0.75 up to ~13% with cold side and hot side temperature at 300 K and 873 K, respectively, if matched with appropriate p-type legs.

42 ENGINEERING↗

2D analysis of tokamak divertor-plasma detachment-bifurcation with operational parameters and geometries

UEDGE simulations with density scans for various input power, transport coefficients and outer poloidal leg length are performed to study the conditions for the existence of a bifurcation-like drop of T e at the outer strike point, commonly referred to as a detachment cliff, when transitioning to a detached plasma from an attached plasma in the outer divertor as the upstream density increases (McLean et al., 2015). The simulation results show that a detachment cliff tends to occur with a higher power input regardless of diffusivities and leg length. Further analysis of change of plasma profiles at a cliff indicate that, in addition to the sharp reduction of the E x B drift fluxes in the outer divertor studied in Jaervinen et al., (2018), the substantial change of the Mach number in the outer divertor and the decrease of the outer mid-plane T e due to the radiation front moving across the separatrix into the confinement region above the X-point consistently occur for all UEDGE density scans that have a detachment cliff. UEDGE time-dependent simulation of the evolution of a detachment cliff shows that the rapid increase of radiation above the X-point occurs in a time scale of ~0.3–0.5, which could possibly be the trigger for the formation of a detachment cliff, quicker than the Mach number change in a time scale of ~1 ms and the drop of T e in a time scale of ~2–3 ms in the outer divertor.