Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “KHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A 20 kiloHertz space station power system

The space station represents the next major U.S. commitment in space. The efficient delivery of power to multiple user loads is key to that success. In 1969, NASA Lewis Research Center began a series of studies with component and circuit developments that led to the high frequency, bi-directional, four quadrant resonant driven converter. Additional studies and subsequent developments into the early 1980's have shown how the high frequency ac power system could provide overall advantages to many aerospace power systems. Because of its wide versatility, it also has outstanding advantages for the Space Station Program and its wide range of users. High frequency ac power provides higher efficiency, lower cost, and improved safety. The 20 kHz power system has exceptional flexibility, is inherently user friendly, and is compatible with all types of energy sources - photovoltaic, solar dynamic, rotating machines or nuclear. Lewis has recently completed development under contract a 25 kW, 20 kHz ac power distribution system testbed. The testbed demonstrates flexibility, versatility, and transparency to user technology as well as high efficiency, low mass, and reduced volume.

Hansen, I. G.↗

Sound Absorption of a 2DOF Resonant Liner with Negative Bias Flow

This report describes an experimental study conducted to determine the effect of negative bias flow on the sound absorption of a two degree-of-freedom liner. The backwall for the liner was designed to act as a double-Helmholtz resonator so as to act as a hard wall at all frequencies except at its resonant frequencies. All normal incident impedance data presented herein was acquired in an impedance tube. The effect of bias flow is investigated for a buried septum porosity of 2% and 19.5% for bias flow orifice mach numbers up to 03 11. As a porous backwall is needed for the flow to pass through, the effect of bias flow on this backwall all had to be evaluated first. The bias flow appears to modify the resistance and reactance of the backwall alone at lower frequencies up to about 2 kHz, with marginal effects at higher frequencies. Absorption coefficients close to unity are achieved for a frequency range of 500-4000 Hz for the overall liner for a septum porosity of 2% and orifice mach number of 0.128. Insertion loss tests performed in a flow duct facility for grazing flow Mach numbers up to 0.2 and septum mach numbers up to 0.15 showed that negative bias flow can increase insertion loss by as much as 10 dB at frequencies in the range of 500 - 1400 Hz compared to no grazing flow. The effectiveness of the negative bias flow is diminished as the grazing flow velocity is increased.

Ahuja, K. K.↗

Sound Absorption of a 2DOF Resonant Liner with Negative Bias Flow

This report describes an experimental study conducted to determine the effect of negative bias flow on the sound absorption of a two degree-of-freedom liner. The backwall for the liner was designed to act as a double-Helmholtz resonator so as to act as a hard wall at all frequencies except at its resonant frequencies. The effect of bias flow is investigated for a buried septum porosity of 2% and 19.5% for bias flow orifice Mach numbers up to 0.311. The bias flow appears to modify the resistance and reactance of the backwall alone at lower frequencies up to about 2 kHz, with marginal effects at higher frequencies. Absorption coefficients close to unity are achieved for a frequency range of 500 - 4000 Hz for the overall liner for a septum porosity of 2% and orifice Mach number of 0.128. Insertion loss tests performed in a flow duct facility for grazing flow Mach numbers up to 0.2 and septum Mach numbers up to 0.15 showed that negative bias flow can increase insertion loss by as much as 10 dB at frequencies in the range of 500 D 1400 Hz compared to no grazing flow. The effectiveness of the negative bias flow is diminished as the grazing flow velocity is increased.

Ahuja, K. K.↗

The earth as a radio source - The nonthermal continuum

It is shown that a weak nonthermal continuum is produced by the earth's magnetosphere extending over a very wide range of frequencies, from 500 Hz in the low-density regions of the magnetotail to above 100 kHz. The frequency spectrum of the continuum radiation consists of two components: a trapped component within the magnetosphere at frequencies below the solar wind plasma frequency and an escaping component propagating freely away from the earth at frequencies above the solar wind plasma frequency. It is also shown that the continuum radiation is generated in a broad region extending through the morning and early afternoon from about 4.0 to 14.0 hours local time immediately beyond the plasmapause boundary, at radial distances from 4.0 to 8.0 earth radii. Possible mechanisms underlying the generation of this radiation are discussed, including the gyrosynchrotron radiation from energetic electrons in the outer radiation zone.

Gurnett, D. A.↗

High power density dc/dc converter: Component selection and design

Further work pertaining to design considerations for the new high power, high frequency dc/dc converters is discussed. The goal of the project is the development of high power, high power density dc/dc converters at power levels in the multi-kilowatt to megawatt range for aerospace applications. The prototype converter is rated for 50 kW at a switching frequency of 50 kHz, with an input voltage of 200 Vdc and an output of 2000 Vdc. The overall power density must be in the vicinity of 0.2 to 0.3 kg/kW.

Divan, Deepakraj M.↗

Design of a near-IR coherent lidar for high spatial and velocity resolution wind measurement

A coherent Doppler lidar based on a CW diode-pumped, injection seeded, Th:YAG laser operating at approx. 2.02 microns is currently under development. This system is optimized for measurements of boundary layer winds with high spatial, temporal, and velocity resolution. Initially, the system will run alongside a new high repetition rate (5-10 kHz) CO2 mini-Master Oscillator Power Amplifier (mini-MOPA) Doppler lidar, which will provide simultaneous range-resolved Differential Absorption Lidar (DIAL) water vapor measurements. Water vapor DIAL operation of the 2 micron system is being considered as a future option. The anticipated specifications and the preliminary design are discussed.

Grund, Christian J.↗

A Low Frequency Radio and Radar Instrument to Explore Jupiter's Icy Moons

The addition of a comprehensive wave investigation to the Jupiter Icy Moons Orbiter (JIMO) science payload will provide a broad range of information on the icy moons of Jupiter including the detection of subsurface liquid oceans; mapping of their ionospheres; their interaction with the magnetospheric environment; and on the Jovian magnetosphere. These measurements are obtained through the use of both passive and active (sounding) means over broad frequency ranges. The frequency range of interest extends from less than 1 Hz to 40 MHz for passive measurements, from approximately 1 kHz to a few MHz for magnetospheric and ionospheric sounding, and between 1 and approximately 10 MHz for subsurface radar sounding. An instrument to detect subsurface radar sounding, magnetospheric interactions, and ionospheric sounding is discussed.

Kurth, W. S.↗

Conventional and cross-correlation brain-stem auditory evoked responses in the white leghorn chick: rate manipulations

Rate-dependent changes in the chick brain-stem auditory evoked response (BAER) using conventional averaging and a cross-correlation technique were investigated. Five 15- to 19-day-old white leghorn chicks were anesthetized with Chloropent. In each chick, the left ear was acoustically stimulated. Electrical pulses of 0.1-ms duration were shaped, attenuated, and passed through a current driver to an Etymotic ER-2 which was sealed in the ear canal. Electrical activity from stainless-steel electrodes was amplified, filtered (300-3000 Hz) and digitized at 20 kHz. Click levels included 70 and 90 dB peSPL. In each animal, conventional BAERs were obtained at rates ranging from 5 to 90 Hz. BAERs were also obtained using a cross-correlation technique involving pseudorandom pulse sequences called maximum length sequences (MLSs). The minimum time between pulses, called the minimum pulse interval (MPI), ranged from 0.5 to 6 ms. Two BAERs were obtained for each condition. Dependent variables included the latency and amplitude of the cochlear microphonic (CM), wave 2 and wave 3. BAERs were observed in all chicks, for all level by rate combinations for both conventional and MLS BAERs. There was no effect of click level or rate on the latency of the CM. The latency of waves 2 and 3 increased with decreasing click level and increasing rate. CM amplitude decreased with decreasing click level, but was not influenced by click rate for the 70 dB peSPL condition. For the 90 dB peSPL click, CM amplitude was uninfluenced by click rate for conventional averaging. For MLS BAERs, CM amplitude was similar to conventional averaging for longer MPIs.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Neuroscience↗

Ultrasonic/sonic drilling/coring (USDC) for planetary applications

One of the major limitations of sampling on Mars and other low gravity environments is the need for high axial force when using conventional drilling. To address this limitation an ultrasonic/sonic drilling/coring (USDC) mechanism has been developed that employs an ultrasonic horn driven by a piezoelectric stack. The horn dnves a free mass that resonates between the horn and drill stein. Tests have shown that the USDC addresses some of the key challenges to the NASA sampling objectives. The USDC is lightweight (450 g), requires low preload (<5N) and can be driven at low power (5W), The device has been shown to drill rocks with various levels of hardness including granite, diorite, basalt and limestone. The hammering action involved with the coring process can produce cores of various shapes, which need not necessarily be round. Because it is driven by piezoelectric ceramics, the USDC is highly tolerant to changes in its operating environment. These actuation materials can be designed to operate at a wide range of temperatures including those expected on Mars and Venus. Although the drill is driven electrically at 20 kHz, a substantial sub-harmonic acoustic component is found that is crucial to drilling performance. An analytical model has been developed to explain this low frequency coupling in the horn, free mass, drill stem and rock.

Peterson, Thomas↗

High Altitude Re-entry Plasma Emulation Experiment (HARPEE)

A table-top apparatus has recently been constructed at the NASA Glenn Research Center to investigate potential solutions for the radio-frequency communication blackout problem -- experienced by landing modules during high-speed atmospheric entry. This customized plasma chamber was designed to emulate Earth-based atmospheric entry plasmas with electron densities in the range of 10^16 m^-3 to 10^19 m^-3. The system makes use of a 40-kHz, perforated coaxial electrode pair to generate a disk-shaped, static plasma with an approximate diameter and thickness of 405 mm and 100 mm, respectively. A translatable Langmuir probe was employed to characterize the radial profile of electron temperature and density as a function the 40-kHz power (< 1 kW) and dry-nitrogen flow rate (< 160 SCCM).

plasma↗

Orbital debris radar instrumentation

In order to increase the usefulness of Goldstone orbital debris observations, several improvements are planned to the experimental Goldstone radar. The first improvement is to add a ranging capability of 1-km accuracy to the radar. This would provide much more detailed information about whatever debris is observed. The second improvement is to widen the bandwidth of the system from 10 kHz to 85 kHz so that particles in more elliptical orbits can be monitored. The two antennas could then also be pointed away from the zenith, say south, where orbits of lesser inclination might also be observed. In any case, the addition of ranging requires a substantial increase of system bandwidth. This article describes the instrumentation necessary to achieve this, together with required signal-processing modifications.

Goldstein, Richard M.↗

Novel Quadratic High Gain Boost Converter With Adaptive Soft-Switching Scheme and Reduced Conduction Loss

In this article, an improved soft-switching quadratic boost converter is proposed. Instead of inserting an additional active clamp or auxiliary zero-voltage transition circuit at the switching node, the proposed topology connects the high-voltage switching node to the input diode node by replacing one of the input diodes with a low-rated switch. The proposed topology can attain soft-switching condition for all the switches and input diode turns- off under zero-current switching (ZCS). The operation of input-side switch not only aids zero-voltage switching (ZVS) turn- on for the main switch but also helps in reducing the conduction loss. Also, the input-side switch operates under ZCS turn- on and ZVS turn- off , making it a loss economical solution. An adaptive timing scheme for driving the input switch is proposed, which can ensure soft-switching condition under varying gain and load range. The detailed operational modes, analysis, and design considerations of the proposed topology are presented. A 250 W hardware prototype is built to validate the performance of the proposed converter operating at 100 kHz switching frequency. Results with adaptive soft-switching scheme shows that the converter is modulated to achieve its best efficiency condition under various system conditions. Furthermore, a peak efficiency of 96.1% at 155 W and efficiencies above 95.75% over a wide load range are achieved using all Si devices.

14 SOLAR ENERGY↗

High-power few-cycle Cr:ZnSe mid-infrared source for attosecond soft x-ray physics

The development of mid-infrared, high-energy pulses of extremely short pulse duration is of great importance to the strong-field physics community, as it enables extension of the high-harmonic cutoff towards the keV range of photon energies. Here we demonstrate a C r 2 + : Z n S e laser amplifier delivering 7 mJ, 100 fs pulses at 1 kHz repetition rate and 2.4 µm central wavelength with excellent energy stability and beam quality. These pulses are post-compressed to 39 fs, 6.2 mJ, and 115 GW peak power in a novel nonlinear compression scheme. The laser system was used to generate coherent soft x-ray radiation up to 0.6 keV covering the entire water window, which is of high importance for bio-relevant applications. The obtained results open a wide range of applications in nonlinear optics, attosecond and strong-field physics, and remote sensing.

Leshchenko, Vyacheslav E. (ORCID:0000000199708559)↗

Ferroresonant Flux-Coupled Battery Charger

Portable battery charger operates at about 20 kHz to take advantage of relatively low weight and low acoustical noise of ferroresonant circuits operating in this frequency range. Charger split into stationary unit connected to powerline and mobile unit connected to battery or other load. Power transferred to mobile unit by magnetic coupling between mating transformer halves. Advantage where sparking at electrical connection might pose explosion hazard or where operator disabled and cannot manipulate plug into wall outlet. Likely applications for charger include wheelchairs and robots.

Mclyman, C. W.↗

Models of Neptune's smooth recurrent radio emission

The quantitative response of the Planetary Radio Astronomy (PRA) instrument to a wave with polarization ellipse of arbitrary shape and orientation, arriving at the antennas from any direction, can be determined. This capability is used to model the time variation of intensity and circular polarization over a range of radio frequencies for proposed radio-source locations and emission characteristics at Neptune. At frequencies below 400 kHz the observed variation of intensity, polarization, and phase are closely simulated in an offset tilted dipole magnetic field by conjugate sources at midlatitude with filled emission cones. The phase of emission at higher frequencies is reproduced by sources at lower latitude. Modeled wide-cone emission does not reach the spacecraft at the observed phase nor have the polarization sense observed before closest approach. Source-surface maps of apparent polarization for the period before closest approach when instrumental response is especially sensitive to source location is presented. The method is capable of extension to more realistic models of the magnetic field.

Sawyer, Constance↗

An NMR study of microvoids in polymers

An understanding of polymer defect structures, like microvoids in polymeric matrices, is crucial to their fabrication and application potential. In this project guest atoms are introduced into the microvoids in PMR-15 and NMR is used to determine microvoid sizes and locations. Xenon is a relatively inert probe that would normally be found naturally in polymer or in NMR probe materials. There are two NMR active xenon isotopes, Xe-129 and Xe-131. The Xe atom has a very high polarizability, which makes it sensitive to the intracrystalline environment of polymers. Interactions between the Xe atoms and the host matrix perturb the Xe electron cloud, deshielding the nuclei, and thereby expanding the range of the observed NMR chemical shifts. This chemical shift range which may be as large as 5000 ppm, permits subtle structural and chemical effects to be studied with high sensitivity. The Xe(129)-NMR line shape has been found to vary in response to changes in the pore symmetry of the framework hosts line Zeolites and Clathrasil compounds. Before exposure to Xe gas, the PMR-15 samples were dried in a vacuum oven at 150 C for 48 hours. The samples were then exposed to Xe gas at 30 psi for 72 hours and sealed in glass tubes with 1 atmosphere of xenon gas. Xenon gas at 1 atmosphere was used to tune up the spectrometer and to set up the appropriate NMR parameters. A single Xe-129 line at 83.003498 Mhz (with protons at 300 Mhz) was observed for the gas. With the xenon charged PMR-15 samples, a second broader line is observed 190 ppm downfield from the gas line (also observed). The width of the NMR line from the Xe-129 absorbed in the polymer is at least partially due to the distribution of microvoid sizes. From the chemical shift (relative to the gas line) and the line width, we estimate the average void sizes to be 2.74 +/- 0.20 angstroms. Since Xe-129 has such a large chemical shift range (approximately 5000 ppm), we expect the chemical shift anisotropy to contribute to the line width (delta upsilon = 2.5 kHz).

Toy, James↗

First Assessments of ICESat-2 Performance Using Aircraft Data

The Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) Is a next-generation laser altimeter designed to continue key observations of ice sheet elevation change, sea ice freeboard, vegetation canopy height, earth surface elevation, and sea surface height. Scheduled for launch in early 2016, ICESat-2 will use a high repetition rate (approximately 10 kHz), small footprint (10m diameter) laser, and a single-photon-sensitive detection strategy (photon counting) to measure precise ranges to the earth's surface. Operating in the green (approximately 532nm), the six beams of ICESat-2 will provide improved spatial coverage compared with ICESat while the differences in transmit energy among the beams provide a large dynamic range. In order to evaluate models of predicted ICESat-2 performance, and provide ICESat-2-like data for algorithm development an airborne ICESat-2 simulator was developed and first flown in 2010, this simulator, the Multiple Altimeter Beam Experimental Lidar (MABEL) has now had three deployments in the western US, and will be deployed to the polar regions in spring of 2012. MABEL uses a similar measurement strategy to what will be used on ICESat-2. MABEL collects more spatially-dense data than ICESat-2 (approximately 2-cm along track) with a smaller 2m diameter footprint in 16 green channels and an additional 8 channels in the infrared. The comparison between frequencies allows for analysis of possible penetration of green energy into water or snow. We present MABEL data collected over deserts, forests, ocean water, lakes. snow covered mountains, and saft flats, provide examples of how these data are being used to develop algorithms that derive geophysical products from ICESat 2 and assess expected performances.

Neumann, Tom↗

Design of a Thomson scattering diagnostic for the SMall Aspect Ratio Tokamak (SMART)

Here, we describe the design of a Thomson scattering (TS) diagnostic to be used on the SMall Aspect Ratio Tokamak (SMART). SMART is a spherical tokamak being commissioned in Spain that aims to explore positive triangularity and negative triangularity plasma scenarios at a low aspect ratio. The SMART TS diagnostic is designed to operate at high spatial resolution, 6 mm scattering length in the low-field side and 9 mm in the high-field side regions, and a wide dynamic range, electron temperature from 1 eV to 1 keV and density from 5 x 10 18 m -3 to 1 x 10 20 m -3 ⁠, to resolve large gradients formed at the plasma edge and in the scrape-off layer (SOL) under different triangularities and low aspect ratios. A 2 J @1064 nm laser will be used that is capable of operating in the burst mode at 1, 2, and 4 kHz to investigate fast phenomena and at 30 Hz to study 1 s (or more) long discharges. The scattered light will be collected over an angular range of 60° – 120° from 28 spatial points in the midplane covering the entire plasma width and the outer midplane SOL. Each scattering signal will be spectrally resolved on five wavelength channels of a polychromator to obtain the electron temperature measurement. We will also present a method to monitor in situ laser alignment in the core during calibrations and plasma operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗