First Dark Matter Results from the XENON100 Experiment

The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter weakly interacting massive particles (WIMPs) scattering off 62 kg of liquid xenon in an ultralow background dual-phase time projection chamber. In this Letter, we present first dark matter results from the analysis of 11.17 live days of nonblind data, acquired in October and November 2009. In the selected fiducial target of 40 kg, and within the predefined signal region, we observe no events and hence exclude spin-independent WIMP-nucleon elastic scattering cross sections above 3.4x10{sup -44} cm{sup 2} for 55 GeV/c{sup 2} WIMPs at 90% confidence level. Below 20 GeV/c{sup 2}, this result constrains the interpretation of the CoGeNT and DAMA signals as being due to spin-independent, elastic, light mass WIMP interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Matter Results from 100 Live Days of XENON100 Data

We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time-projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows the selection of only the innermost 48 kg as the ultralow background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in the signal region with an expected background of (1.8{+-}0.6) events. This leads to the most stringent limit on dark matter interactions today, excluding spin-independent elastic weakly interacting massive particle (WIMP) nucleon scattering cross sections above 7.0x10{sup -45} cm{sup 2} for a WIMP mass of 50 GeV/c{sup 2} at 90% confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results from CUORE: A Search for Lepton Number Violation via 0 ν β β Decay of Te 130

The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-numberviolating process: 130 Te neutrinoless double-beta decay. Examining a total TeO 2 exposure of 86.3 kg yr, characterized by an effective energy resolution of d7.7 ± 0.5T keV FWHM and a background in the region of interest of d0.014 ± 0.002T counts=dkeV kg yrT, we find no evidence for neutrinoless double-beta decay. Including systematic uncertainties, we place a lower limit on the decay half-life of T 0ν 1/2 ( 130 Te) > 1.3 × 10 25 yr (90% C.L.); the median statistical sensitivity of this search is 7.0 × 10 24 yr. Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find T 0ν 1/2 ( 130 Te) > 1.5 × 10 25 yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find m ββ < (110 - 520) meV, where the range reflects the nuclear matrix element estimates employed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Direct Limit on Neutrinoless Double Beta Decay Half-Life of 128 $\mathrm{Te}$ with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) at Laboratori Nazionali del Gran Sasso of INFN in Italy is an experiment searching for neutrinoless double beta (0νββ) decay. Its main goal is to investigate this decay in 130 Te, but its ton-scale mass and low background make CUORE sensitive to other rare processes as well. Here, in this Letter, we present our first results on the search for 0νββ decay of 128 Te, the Te isotope with the second highest natural isotopic abundance. We find no evidence for this decay, and using a Bayesian analysis we set a lower limit on the 128 Te 0νββ decay half-life of T 1/2 > 3.6 x 10 24 yr (90% CI). This represents the most stringent limit on the half-life of this isotope, improving by over a factor of 30 the previous direct search results, and exceeding those from geochemical experiments for the first time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A compact and flexible induction furnace for in situ X-ray microradiograhy and computed microtomography at Elettra: design, characterization and first tests

A compact and versatile induction furnace for in situ high-resolution synchrotron and laboratory hard X-ray microradiography and computed microtomography is described. The furnace can operate from 773 to 1723 K. Its programmable controller enables the user to specify multiple heating and cooling ramp rates as well as variable dwell times at fixed temperatures allowing precise control of heating and cooling rates to within 5 K. The instrument can work under a controlled atmosphere. Thanks to the circular geometry of the induction coils, the heat is homogeneously distributed in the internal volume of the graphite cell ( ca . 150 mm 3 ) where the sample holder is located. The thermal gradient within the furnace is less than 5 K over a height of ca . 5 mm. This new furnace design is well suited to the study of melting and solidification processes in geomaterials, ceramics and several metallic alloys, allowing fast heating (tested up to 6.5 K s -1 ) and quenching (up to 21 K s -1 ) in order to freeze the sample microstructure and chemistry under high-temperature conditions. The sample can be held at high temperatures for several hours, which is essential to follow phenomena with relatively slow dynamics, such as crystallization processes in geomaterials. The utility of the furnace is demonstrated through a few examples of experimental applications performed at the Elettra synchrotron laboratory (Trieste, Italy).

Kudrna Prašek, Marko↗

Kinetic parameters of the GUINEVERE reference configuration in VENUS-F reactor obtained from a pile noise experiment using Rossi and Feynman methods

A pile noise measurement campaign has been conducted by the CEA in the VENUS-F reactor (SCK-CEN, Mol Belgium) in April 2011 in the reference critical configuration of the GUINEVERE experimental program. The experimental setup made it possible to estimate the core kinetic parameters: the prompt neutron decay constant, the delayed neutron fraction and the generation time. A precise assessment of these constants is of prime importance. In particular, the effective delayed neutron fraction is used to normalize and compare calculated reactivities of different subcritical configurations, obtained by modifying either the core layout or the control rods position, with experimental ones deduced from the analysis of measurements. This paper presents results obtained with a CEA-developed time stamping acquisition system. Data were analyzed using Rossi-α and Feynman-α methods. Results were normalized to reactor power using a calibrated fission chamber with a deposit of Np-237. Calculated factors were necessary to the analysis: the Diven factor was computed by the ENEA (Italy) and the power calibration factor by the CNRS/IN2P3/LPC Caen. Results deduced with both methods are consistent with respect to calculated quantities. Recommended values are given by the Rossi-α estimator, that was found to be the most robust. The neutron generation time was found equal to 0.438 ± 0.009 μs and the effective delayed neutron fraction is 765 ± 8 pcm. Discrepancies with the calculated value (722 pcm, calculation from ENEA) are satisfactory: -5.6% for the Rossi-α estimate and -2.7% for the Feynman-α estimate. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Forward modeling of an atmospheric scenario: path characterization in terms of scattering intensity

The knowledge of possible impairments due to atmospheric propagation is of importance in the framework of future 5G mobile networks that use spectrum resource up to the W band. Here, the authors propose the scalar Scatter Indicator (SI), defined as the difference between the simulated TB at 72 GHz and the TB value at the same frequency estimated from a combination of TBs values at 23.8 and 31.4 GHz under assumed scatter-free condition. On the basis of radiosonde profiles observed in Milan, Linate (Italy) in 2005, clear-sky scenarios are used as reference to define a scatter-free TB’s database. A second database of simulated TBs including scattering effects is generated with ARTS to build the SI. Numerical results show that the SI assumes significant positive values with increasing drop effective radius and total liquid water LWP and it can be used to identify the scattering due to hydrometeor

54 ENVIRONMENTAL SCIENCES↗

Image reconstruction of shielded mixed-oxide fuel using a dual-particle imaging system

The dual-particle imaging system being developed at the University of Michigan was used at the Joint Research Centre in Ispra, Italy for measurements on samples of special nuclear material. A 1,150-g mixed-oxide (MOX) fuel sample was measured with various shielding configurations to determine how the presence of lead and/or polyethylene shielding degrades the system's ability to localize a source by simultaneous neutron and photon imaging. Three two-hour measurements were taken with the source shielded by an: a) 8-mm lead sheath and 5.1-cm lead bricks, b) 8-mm lead sheath and 6.5-cm polyethylene bricks, and c) 8-mm lead sheath, 5.1-cm lead bricks, and 6.5-cm polyethylene bricks. The 8-mm lead sheath was used in all cases to reduce the measured photon count rate. A “bare” measurement was also made by using only the 8-mm lead sheath, but the unexpected presence of additional sources has rendered the measurement unsuitable for comparison. Here, the resulting images show that the dual-particle imaging system is able to accurately localize the MOX canister in the presence of intervening material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation of Advanced Accelerated Stress Testing with Polyamide-Based Photovoltaic Backsheet Field-Failures

Cracking of polyamide (PA)-based photovoltaic (PV) backsheet materials has been widely reported for field-aged modules. Failure was not detected by conventional accelerated stress tests (ASTs), which lacked the necessary combination of stress factors and/or factor sequences. PA-based AAA backsheet cracking has since been reproduced through combined and sequential stress testing. Planar- and cross-sectional-optical microscopy as well as Fourier-transform Infrared Spectroscopy (FTIR), have been used to elucidate the mechanical and chemical changes which lead to failure of the backsheet. Field-aged backsheet samples demonstrating failure in various climates (including locations in China and Italy) are also analyzed. Through the analysis, a comparison is made between the different stress testing protocols and the field-aged samples to validate relevance of the advanced stress tests. It is shown that the changes induced through combined-accelerated stress testing (C-AST) were most representative of changes induced by the field, supporting the relevance of C-AST and providing validity for the test protocol.

14 SOLAR ENERGY↗

Status and Challenges of the Interaction Region Magnets for HL-LHC

About one hundred magnets of six different types shall be installed in the High Luminosity LHC (HL-LHC) in the years 2026-2028 at CERN. The magnets design, construction and test are based on CERN collaborations with institutes and industrial partners in USA, Spain, Italy, Japan and China. Three types of correctors are based on Nb-Ti technology and feature conductor peak fields in the 2 to 4 T range: for all of them the prototype phase has been successfully completed. The production is well advanced for the superferric correctors, and is starting for the canted cosine theta correctors and for the nested correctors. The separation and recombination Nb-Ti dipoles D1 and D2, with a 4.5-6 T bore field range, are both in the prototype phase after the completion of the short model program. The most challenging magnet, the Nb 3 Sn quadrupole with conductor peak field above 11 T, is in the prototype phase at CERN and halfway through the production phase in the USA. In this paper we will give, for each type of magnet, an overview of the main achievements obtained so far and we will outline the technical points still needing validation from the prototype program.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO

Future ton-scale liquefied noble gas detectors depend on efficient light detection in the vacuum ultraviolet (VUV) range. In the past years, silicon photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large-area avalanche photodiodes. The next-generation double-beta decay experiment, nEXO, with a 5-ton liquid xenon time projection chamber will use SiPMs for detecting the 175-nm xenon scintillation light, in order to achieve an energy resolution of σ/Q ββ =1 %. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler, Trento, Italy, in two complementary setups. It includes measurements of the photon-detection efficiency (PDE) with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. Here, we report improved PDE at 175 nm compared to previous generation devices that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Consumption-Based Conservation Targeting: Linking Biodiversity Loss to Upstream Demand through a Global Wildlife Footprint: Global wildlife footprint

Although most conservation efforts address the direct, local causes of biodiversity loss, effective long-term conservation will require complementary efforts to reduce the upstream economic pressures, such as demands for food and forest products, which ultimately drive these downstream losses. Here, we present a wildlife footprint analysis that links global losses of wild birds to consumer purchases across 57 economic sectors in 129 regions. The United States, India, China, and Brazil have the largest regional wildlife footprints, while per-person footprints are highest in Mongolia, Australia, Botswana, and the United Arab Emirates. A US$100 purchase of bovine meat or rice products occupies approximately 0.1 km 2 of wild bird ranges, displacing 1–2 individual birds, for 1 year. Globally significant importer regions, including Japan, the United Kingdom, Germany, Italy, and France, have large footprints that drive wildlife losses elsewhere in the world and represent important targets for consumption-focused conservation attention.

Biodiversity & Conservation↗

Elevated CO2 increases tree-level intrinsic water use efficiency: insights from carbon and oxygen isotope analyses in tree rings across three forest FACE sites

Elevated CO2 increases intrinsic water use efficiency (WUEi) of forests, but the magnitude of this effect and its interaction with climate is still poorly understood. We combined tree ring analysis with isotope measurements at three Free Air CO2 Enrichment (FACE, POP-EUROFACE, in Italy; Duke FACE in North Carolina and ORNL in Tennessee, USA) sites, to cover the entire life of the trees. We used 13C to assess carbon isotope discrimination ( 13C ci/ca) and changes in WUEi, while direct CO2 effects on stomatal conductance were explored using 18O as a proxy. Across all the sites, elevated CO2 increased 13C-derived WUEi on average by 73% for Liquidambar styraciflua, 77% for Pinus taeda and 75% for Populus sp., but through different ecophysiological mechanisms. Our findings provide a robust means of predicting WUEi responses from a variety of tree species exposed to variable environmental conditions over time, and species-specific relationships that can help modeling elevated CO2 and climate impacts on forest productivity, carbon and water balances.

Battipaglia, Giovanna↗

Genotype-dependent contribution of CBF transcription factors to long-term acclimation to high light and cool temperature

When grown under cool temperature, winter annuals upregulate photosynthetic capacity as well as freezing tolerance. Here, the role of three cold-induced C-repeat-binding factor (CBF1–3) transcription factors in photosynthetic upregulation and freezing tolerance was examined in two Arabidopsis thaliana ecotypes originating from Italy (IT) or Sweden (SW), and their corresponding CBF1–3-deficient mutant lines it: cbf123 and sw: cbf123 . Photosynthetic, morphological and freezing-tolerance phenotypes, as well as gene expression profiles, were characterized in plants grown from the seedling stage under different combinations of light level and temperature. Under high light and cool (HLC) growth temperature, a greater role of CBF1–3 in IT versus SW was evident from both phenotypic and transcriptomic data, especially with respect to photosynthetic upregulation and freezing tolerance of whole plants. Overall, features of SW were consistent with a different approach to HLC acclimation than seen in IT, and an ability of SW to reach the new homeostasis through the involvement of transcriptional controls other than CBF1–3. These results provide tools and direction for further mechanistic analysis of the transcriptional control of approaches to cold acclimation suitable for either persistence through brief cold spells or for maximisation of productivity in environments with continuous low temperatures.

59 BASIC BIOLOGICAL SCIENCES↗

Natural variation in the C‐repeat binding factor cold response pathway correlates with local adaptation of Arabidopsis ecotypes

Summary The natural range of Arabidopsis thaliana (Arabidopsis) encompasses geographical regions that have greatly differing local climates, including harshness of winter temperatures. A question thus raised is whether differences in freezing tolerance might contribute to local adaptation in Arabidopsis. Consistent with this possibility is that Arabidopsis accessions differ in freezing tolerance and that those collected from colder northern latitudes are generally more tolerant to freezing than those collected from warmer southern latitudes. Moreover, recent studies with Arabidopsis genotypes collected from sites in Sweden ( SW ) and Italy ( IT ) have established that the two accessions are locally adapted, that the SW ecotype is more tolerant of freezing than the IT ecotype, and that genetic differences between the two ecotypes that condition local adaptation and freezing tolerance map to a region that includes the C‐repeat binding factor ( CBF ) locus. The CBF locus includes three genes – CBF 1 , CBF 2 and CBF 3 – that are induced by low temperature and encode transcription factors that regulate a group of more than 100 genes, the CBF regulon, which impart freezing tolerance. Here we show that cold induction of most CBF regulon genes is lower in IT plants compared with SW plants, and that this is due to the IT CBF 2 gene encoding a non‐functional CBF 2 protein. The non‐functional IT CBF 2 protein also contributes to the lower freezing tolerance of the IT plants compared with the SW plants. Taken together, studies on the SW and IT ecotypes provide evidence that natural variation in the CBF pathway has contributed to adaptive evolution in these Arabidopsis populations.

Gehan, Malia A.↗

Energy Savings Certificate Markets: Opportunities and Implementation Barriers

Early experiences with energy savings certificates (ESCs) have revealed their merits and the challenges associated with them. While in the United States ESC markets have yet to gain significant traction, lessons can be drawn from early experiences in the states of Connecticut and New York, as well as from established markets in Italy, France, and elsewhere. The staying power of European examples demonstrates that ESCs can help initiate more efficiency projects. This article compares ESCs with renewable energy certificates (RECs), looks at the unique opportunities and challenges they present, and reviews solutions and best practices demonstrated by early ESC markets. Three major potential ESC market types are also reviewed: compliance, voluntary, and carbon. Additionally, factors that will benefit ESC markets in the United States are examined: new state EEPS policies, public interest in tools to mitigate climate change, and the growing interest in a voluntary market for ESCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of PHADEC method for the decontamination of radioactive steam piping components

The dismantling of nuclear plants is a complex activity that originates often a large quantity of radioactive contaminated residue. In this paper the attention was focused on the PHADEC (Phosphoric Acid Decontamination) plant adopted for the clearance of Caorso NPP (in Italy) metallic systems and components contaminated by Co{sup 60} (produced by the neutron capture in the iron materials), like the main steam lines, moisture separator of the turbine buildings, etc.. The PHADEC plant consists in a chemical off line treatment: the crud, deposited along the steam piping during life plant as an example, is removed by means of acid attacks in ponds coupled to a high pressure water washing. Due to the fact that the removed contaminated layers, essentially, iron oxides of various chemical composition, depend on components geometry, type of contamination and time of treatment in the PHADEC plant, it becomes of meaningful importance to suggest a procedure capable to improve the control of the PHADEC process parameters. This study aimed thus at the prediction and optimization of the mentioned treatment time in order to improve the efficiency of the plant itself and to achieve, in turn, the minimization of produced wastes. To the purpose an experimental campaign was carried out by analysing several samples, i.e. taken along the main steam piping line. Smear tests as well as metallographic analyses were carried out in order to determine respectively the radioactivity distribution and the crud composition on the inner surface of the components. Moreover the radioactivity in the crud thickness was measured. These values allowed finally to correlate the residence time in the acid attack ponds to the level of the achieved decontamination. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation protection measurements around a 12 MeV mobile dedicated IORT accelerator

Purpose: The aim of this study is to investigate radioprotection issues that must be addressed when dedicated accelerators for intraoperative radiotherapy (IORT) are used in operating rooms. Recently, a new version of a mobile IORT accelerator (LIAC Sordina SpA, Italy) with 12 MeV electron beam has been implemented. This energy is necessary in some specific pathology treatments to allow a better coverage of thick lesions. At an electron energy of 10 MeV, leakage and scattered x-ray radiation (stray radiation) coming from the accelerator device and patient must be considered. If the energy is greater than 10 MeV, the x-ray component will increase; however, the most meaningful change should be the addition of neutron background. Therefore, radiation exposure of personnel during the IORT procedure needs to be carefully evaluated. Methods: In this study, stray x-ray radiation was measured and characterized in a series of spherical projections by means of an ion chamber survey meter. To simulate the patient during all measurements, a polymethylmethacrylate (PMMA) slab phantom with volume 30x30x15 cm{sup 3} and density 1.19 g/cm{sup 3} was used. The PMMA phantom was placed along the central axis of the beam in order to absorb the electron beams and the tenth value layer (TVL) and half value layer (HVL) of scattered radiation (at 0 deg., 90 deg., and 180 deg. scattering angles) were also measured at 1 m of distance from the phantom center. Neutron measurements were performed using passive bubble dosimeters and a neutron probe, specially designed to evaluate ambient dose equivalent H{sup *}(10). Results: The x-ray equivalent dose measured at 1 m along the beam axis at 12 MeV was 260 {mu}Sv/Gy. The value measured at 1 m at 90 deg. scattering angle was 25 {mu}Sv/Gy. The HVL and TVL values were 1.1 and 3.5 cm of lead at 0 deg., and 0.4 and 1 cm at 90 deg., respectively. The highest equivalent dose of fast neutrons was found to be at the surface of the phantom on the central beam axis (2.9{+-}0.6 {mu}Sv/Gy), while a lower value was observed below the phantom (1.6{+-}0.3 {mu}Sv/Gy). The neutron dose equivalent at 90 deg. scattering angle and on the floor plane on the beam axis below the beam stopper was negligible. Conclusions: Our data confirm that neutron exposure levels around the new dedicated IORT accelerator are very low. Mobile shielding panels can be used to reduce x-ray levels to below regulatory levels without necessarily providing permanent shielding in the operating room.

61 RADIATION PROTECTION AND DOSIMETRY↗