Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Fiber-coupled digital photo sensors for large Time Projection Chambers

Here, this paper presents a novel approach to addressing challenges in neutrino event reconstruction within large Time Projection Chambers (TPCs). By integrating fiber-coupled digital silicon photomultipliers, we propose a design that enhances light detection and improves both energy resolution and event reconstruction. Advancements in power and signal over fiber technologies are leveraged to deploy digital sensors within the TPC bulk volume, enabling precise timing and robust particle identification.

47 OTHER INSTRUMENTATION↗

Measurement of the mean excitation energy of liquid argon

The mean excitation energy (I-value) of liquid argon is a critical input for energy estimation in neutrino oscillation experiments. It is measured to be 199 +4 -5 eV using the range of 402.2 MeV protons from the Fermilab Linac. This compares to the author's recent evaluation of (197 ± 7) eV based on a combination of an oscillator strength distribution analysis, gaseous argon range measurements, sparse stopping power data on solid argon, and an extrapolation of data on the effect of phase from other substances. Using all sources of information, we recommend a value of (198 ± 4) eV for liquid argon, which is significantly higher than 188 eV, from ICRU-37's gaseous argon evaluation, commonly used in Monte Carlo codes such as Geant4.

47 OTHER INSTRUMENTATION↗

Characterization of proton-induced damage in thick, p-channel skipper-CCDs

Here, in this work, we characterize the radiation-induced damage in two thick, p-channel skipper-CCDs irradiated unbiased and at room temperature with 217-MeV protons. We evaluate the overall performance of the sensors and demonstrate their single-electron/single-photon sensitivity after receiving a fluence on the order of 10 10 protons/cm 2 . Using the pocket-pumping technique, we quantify and characterize the proton-induced defects from displacement damage. We report an overall trap density of 0.134 traps/pixel for a displacement damage dose of 2.3 × 10 7 MeV/g. Three main proton-induced trap species were identified, V 2 , C i O i and V n O m , and their characteristic trap energies and cross sections were extracted. We found that while divacancies are the most common proton-induced defects, C i O i defects have a greater impact on charge integrity at typical operating temperatures because their emission-time constants are comparable or larger than typical readout times. To estimate ionization damage, we measure the characteristic output transistor curves. We found no threshold voltage shifts after irradiation. Our results highlight the potential of skipper-CCDs for applications requiring high-radiation tolerance and can be used to find the operating conditions in which effects of radiation-induced damage are mitigated.

47 OTHER INSTRUMENTATION↗

Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC

Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.

47 OTHER INSTRUMENTATION↗

tomoCAM : fast model-based iterative reconstruction via GPU acceleration and non-uniform fast Fourier transforms

X-ray-based computed tomography is a well established technique for determining the three-dimensional structure of an object from its two-dimensional projections. In the past few decades, there have been significant advancements in the brightness and detector technology of tomography instruments at synchrotron sources. These advancements have led to the emergence of new observations and discoveries, with improved capabilities such as faster frame rates, larger fields of view, higher resolution and higher dimensionality. These advancements have enabled the material science community to expand the scope of tomographic measurements towards increasingly in situ and in operando measurements. In these new experiments, samples can be rapidly evolving, have complex geometries and restrictions on the field of view, limiting the number of projections that can be collected. In such cases, standard filtered back-projection often results in poor quality reconstructions. Iterative reconstruction algorithms, such as model-based iterative reconstructions (MBIR), have demonstrated considerable success in producing high-quality reconstructions under such restrictions, but typically require high-performance computing resources with hundreds of compute nodes to solve the problem in a reasonable time. Here, tomoCAM , is introduced, a new GPU-accelerated implementation of model-based iterative reconstruction that leverages non-uniform fast Fourier transforms to efficiently compute Radon and back-projection operators and asynchronous memory transfers to maximize the throughput to the GPU memory. The resulting code is significantly faster than traditional MBIR codes and delivers the reconstructive improvement offered by MBIR with affordable computing time and resources. tomoCAM has a Python front-end, allowing access from Jupyter -based frameworks, providing straightforward integration into existing workflows at synchrotron facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

femto-PIXAR: a self-supervised neural network method for reconstructing femtosecond X-ray free electron laser pulses

X-ray Free Electron Lasers (X-FELs) operate in a wide range of lasing configurations for a broad variety of scientific applications at ultrafast time-scales such as structural biology, materials science, and atomic and molecular physics. Shot-by-shot characterization of the X-FEL pulses is crucial for analysis of many experiments as well as tuning the X-FEL performance. However, for the weak pulses found in advanced configurations, e.g. those needed for coherent, two-pulse studies of quantum materials, there is no current method for reliably resolving pulse profiles. Here we show that a physics-based U-net model can reconstruct the individual pulse power profiles for sub-picosecond pulse separation without the need for simulations. Using experimental data from weak X-FEL pulse pairs, we demonstrate we can learn the pulse characteristics on a shot-by-shot basis when conventional methods fail.

43 PARTICLE ACCELERATORS↗

Exploring Novel Technologies for Particle Tracking in Gas TPCs (Final Technical Report)

This report provides the final results from R&D on a novel 2D readout for a time projection chamber (TPC), which operates with negative-ion drift. The readout consists of two gas electron multiplier (GEM) devices places at an angle with respect to each other. The 2D range of particles interacting in the TPC is reconstructed using pulse-shape timing only. Due to the low diffusion and drift speeds of the negative-ions carrying the track information to the anode, the track resolution is <200 microns. Acquiring this level of resolution for short, low energy particle tracks in a standard TPC would require a fine granularity strip or pixel readout with many 1000s of electronic channels. With this novel readout, only two channels are needed. Our results showed that the concept is fundamentally sound. We found a number of issues related to how well the timing signals are determined from the pulse waveforms. Solutions for these had to be left for future R&D.

47 OTHER INSTRUMENTATION↗

The Muon Collider

Muons offer a unique opportunity to build a compact high-energy electroweak collider at the 10 TeV scale. A Muon Collider enables direct access to the underlying simplicity of the Standard Model and unparalleled reach beyond it. It will be a paradigm-shifting tool for particle physics representing the first collider to combine the high-energy reach of a proton collider and the high precision of an electron-positron collider, yielding a physics potential significantly greater than the sum of its individual parts. A high-energy muon collider is the natural next step in the exploration of fundamental physics after the HL-LHC and a natural complement to a future low-energy Higgs factory. Such a facility would significantly broaden the scope of particle colliders, engaging the many frontiers of the high energy community. The last European Strategy for Particle Physics Update and later the Particle Physics Project Prioritisation Panel in the US requested a study of the muon collider, which is being carried on by the International Muon Collider Collaboration. In this comprehensive document we present the physics case, the state of the work on accelerator design and technology, and propose an R\&D project that can make the muon collider a reality.

Accelerator Physics (physics.acc-ph)↗

First Light from Beam Neutrinos on an LAPPD in ANNIE,

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) probes the physics of neutrino-nucleus interactions in a gadolinium-loaded water (Gd-water) target while serving as a flexible testbed for advanced next-generation optical neutrino detection technologies. These advanced technologies include novel detection media (particularly Gd-water and hybrid Cherenkov-scintillation through water-based liquid scintillator) and novel photosensors. In this paper we demonstrate the first implementation of a fully-integrated setup for Large Area Picosecond PhotoDetectors (LAPPDs) in a neutrino experiment. Details are presented regarding the design, commissioning, and deployment of an LAPPD and the supporting systems. We also present the first neutrino interactions ever observed with an LAPPD.

FOS: Physical sciences↗

Some comments on electrostatic analysers.

Electrostatic spectrometers discussing deflection type, retarding-potential type and magnetic analyzers, advantages, uses, flux measurement techniques via energy selectors, etc

ROCKET SOUNDING↗

POLAR 5 - An electron accelerator experiment within an aurora. III - Evidence for significant spacecraft charging by an electron accelerator at ionospheric altitudes

The POLAR 5 rocket experiment carried an electron accelerator on a 'daughter' payload which injected a 0.1 A beam of 10 keV electrons in a pulsed mode every 410 ms. With spin and precession, injections were made over a wide range of pitch angles. Measurements from a double probe electric field instrument and from particle detectors on the 'mother' payload and from a crude RPA on the 'daughter' payload are interpreted to indicate that the 'daughter' charges to a potential between several hundred volts and 1 kV. The neutralizing return current to the 'daughter' is shown to be asymmetrically distributed with the majority being collected from the direction of the beam. The additional electrons necessary to neutralize the daughter are thought to be produced and heated through beam-plasma interactions postulated by Maehlum et al. (1980) and Grandal et al. (1980) to explain the particle and optical measurements. Significant electric fields emanating from the charged 'daughter' and the beam are seen at distances exceeding 100 m at the 'mother' payload.

Jacobsen, T. A.↗