Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

An Integrated Optimal Estimation Approach to Spitzer Space Telescope Focal Plane Survey

This paper discusses an accurate and efficient method for focal plane survey that was used for the Spitzer Space Telescope. The approach is based on using a high-order 37-state Instrument Pointing Frame (IPF) Kalman filter that combines both engineering parameters and science parameters into a single filter formulation. In this approach, engineering parameters such as pointing alignments, thermomechanical drift and gyro drifts are estimated along with science parameters such as plate scales and optical distortions. This integrated approach has many advantages compared to estimating the engineering and science parameters separately. The resulting focal plane survey approach is applicable to a diverse range of science instruments such as imaging cameras, spectroscopy slits, and scanning-type arrays alike. The paper will summarize results from applying the IPF Kalman Filter to calibrating the Spitzer Space Telescope focal plane, containing the MIPS, IRAC, and the IRS science Instrument arrays.

optimal estimations↗

A Dynamic Optimization Technique for Siting the NASA-Clark Atlanta Urban Rain Gauge Network (NCURN)

NASA satellites and ground instruments have indicated that cities like Atlanta, Georgia may create or alter rainfall. Scientists speculate that the urban heat island caused by man-made surfaces in cities impact the heat and wind patterns that form clouds and rainfall. However, more conclusive evidence is required to substantiate findings from satellites. NASA, along with scientists at Clark Atlanta University, are implementing a dense, urban rain gauge network in the metropolitan Atlanta area to support a satellite validation program called Studies of PRecipitation Anomalies from Widespread Urban Landuse (SPRAWL). SPRAWL will be conducted during the summer of 2003 to further identify and understand the impact of urban Atlanta on precipitation variability. The paper provides an. overview of SPRAWL, which represents one of the more comprehensive efforts in recent years to focus exclusively on urban-impacted rainfall. The paper also introduces a novel technique for deploying rain gauges for SPRAWL. The deployment of the dense Atlanta network is unique because it utilizes Geographic Information Systems (GIS) and Decision Support Systems (DSS) to optimize deployment of the rain gauges. These computer aided systems consider access to roads, drainage systems, tree cover, and other factors in guiding the deployment of the gauge network. GIS and DSS also provide decision-makers with additional resources and flexibility to make informed decisions while considering numerous factors. Also, the new Atlanta network and SPRAWL provide a unique opportunity to merge the high-resolution, urban rain gauge network with satellite-derived rainfall products to understand how cities are changing rainfall patterns, and possibly climate.

Shepherd, J. Marshall↗

Measuring Solar Doppler Velocities in the He II 30.38 nm Emission Using the EUV Variability Experiment (EVE)

The EUV Variability Experiment (EVE) onboard the Solar Dynamics Observatory has provided unprecedented measurements of the solar EUV irradiance at high temporal cadence with good spectral resolution and range since May 2010. The main purpose of EVE was to connect the Sun to the Earth by providing measurements of the EUV irradianceas a driver for space weather and Living With a Star studies, but after launch the instrument has demonstrated the significance of its measurements in contributing to studies looking at the sources of solar variability for pure solar physics purposes. This paper expands upon previous findings that EVE can in fact measure wavelength shifts during solar eruptive events and therefore provide Doppler velocities for plasma at all temperatures throughout the solar atmosphere from the chromosphere to hot flaring temperatures. This process is not straightforward as EVE was not designed or optimized for these types of measurements. In this paper we describe the many detailed instrumental characterizations needed to eliminate the optical effects in order to provide an absolute baseline for the Doppler shift studies. An example is given of a solar eruption on 7 September 2011 (SOL2011-09-07), associated with an X1.2 flare, where EVE Doppler analysis shows plasma ejected from the Sun in the He II 30.38 nm emission at a velocity of almost 120 km s(exp -1) along the line-of-sight.

Chamberlin, Phillip Clyde↗

Online submicron particle sizing by dynamic light scattering using autodilution

Efficient production of a wide range of commercial products based on submicron colloidal dispersions would benefit from instrumentation for online particle sizing, permitting real time monitoring and control of the particle size distribution. Recent advances in the technology of dynamic light scattering (DLS), especially improvements in algorithms for inversion of the intensity autocorrelation function, have made it ideally suited to the measurement of simple particle size distributions in the difficult submicron region. Crucial to the success of an online DSL based instrument is a simple mechanism for automatically sampling and diluting the starting concentrated sample suspension, yielding a final concentration which is optimal for the light scattering measurement. A proprietary method and apparatus was developed for performing this function, designed to be used with a DLS based particle sizing instrument. A PC/AT computer is used as a smart controller for the valves in the sampler diluter, as well as an input-output communicator, video display and data storage device. Quantitative results are presented for a latex suspension and an oil-in-water emulsion.

Nicoli, David F.↗

Polarization Phase-Compensating Coats for Metallic Mirrors

A method of compensating for or minimizing phase differences between orthogonal polarizations of light reflected from metallic mirrors at oblique incidence, as, for example, from weakly curved mirrors, is undergoing development. The method is intended to satisfy a need to maintain precise polarization phase relationships or minimum polarization differences needed for proper operation of telescopes and other scientific instruments that include single or multiple mirrors. The basic idea of the method is to optimally coat mirrors with thin engineered layers of materials that introduce phase differences that, as nearly precisely as possible, are opposite of the undesired phase differences arising in reflection with non-optimum coatings. Depending on the specific optical system, the method could involve any or all of the following elements: a) Optimization of a single coat on all the mirrors in the system. b) Optimization of a unique coat for each mirror such that the polarization phase effects of the coat on one mirror compensate, to an acceptably high degree over an acceptably wide wavelength range, for those of the coat on another mirror. c) Tapering the coat on each mirror. Optimization could involve the choice of a single dielectric coating material and its thickness, or design of a more complex coat consisting of multiple layers of different dielectric materials and possibly some metallic materials. Such designs and coatings are particularly significant and needed for obtaining very high quality of wavefront required in high-contrast imaging instruments such as the NASA Terrestrial Planet Finder Coronagraph.

Balasubramanian, Kunjithapatham↗

Thermal Infrared Spectral Imager for Airborne Science Applications

An airborne thermal hyperspectral imager is under development which utilizes the compact Dyson optical configuration and quantum well infrared photo detector (QWIP) focal plane array. The Dyson configuration uses a single monolithic prism-like grating design which allows for a high throughput instrument (F/1.6) with minimal ghosting, stray-light and large swath width. The configuration has the potential to be the optimal imaging spectroscopy solution for lighter-than-air (LTA) vehicles and unmanned aerial vehicles (UAV) due to its small form factor and relatively low power requirements. The planned instrument specifications are discussed as well as design trade-offs. Calibration testing results (noise equivalent temperature difference, spectral linearity and spectral bandwidth) and laboratory emissivity plots from samples are shown using an operational testbed unit which has similar specifications as the final airborne system. Field testing of the testbed unit was performed to acquire plots of apparent emissivity for various known standard minerals (such as quartz). A comparison is made using data from the ASTER spectral library.

QWIP↗

The Mark III stellar interferometer

The Mark III interferometer is an operational long baseline stellar interferometer on Mt. Wilson with four-possible baseline configurations from 9m NE-SW to 20m N-S. The interferometer was designed to be a highly automated astronomical instrument to measure stellar positions and diameters to a magnitude limit of seven. Initial fringe observations were made in September 1986 with a 12-m N-S baseline. In the following months, semi-automated astrometric and stellar diameter measurements were also made. This paper describes the hardware and software components of the instrument and its operational characteristics. The interferometer has several novel features. One is the use of optimal estimation and control algorithms (e.g. Kalman filters) in the control loops. Another is the ability to operate both as a closed-loop phased interferometer and eventually as an open-loop or absolute coherent interferometer. High thermal stability and mechanical accuracy should permit the instrument to point blind at an astronomical object and maintain optical path equality to within the limits set by the atmosphere. In this absolute interferometric mode of operation, it should be possible to observe faint astronomical objects that are too dim for phase tracking. In theory, measurements of amplitude, group delay, and closure phase will be possible to 14 mag.

Shao, M.↗

Extreme Longitudinal Compression of Optimized Beams for MEV Ultrafast Electron Diffraction (Final Technical Report)

We worked out the design of a high repetition rate MeV energy ultrafast electron diffraction instrument based on the existing Cornell photoinjector, which can readily be applied to the presented findings. This example is a blueprint of other similarly arranged UED setups. Using particle tracking simulations in conjunction with multiobjective genetic algorithm optimization, we explored the smallest bunch lengths, emittance, and probe spot sizes achievable. As two limits, we defined stroboscopic conditions (with single electrons per pulse) and operation with 10 5 electrons per bunch which may be suitable for single-shot diffraction images. In the stroboscopic case, the flexibility provided by the many cavity bunching and acceleration allows for longitudinal phase space linearization without a higher harmonic field, providing sub-fs bunch lengths at the sample. Given low emittance photoemission conditions, these small bunch lengths can be maintained with probe transverse sizes at the single micron (1 μm) scale and below. In the case of 10 5 electrons per pulse, we simulated state-of-the-art 5D brightness conditions: rms bunch lengths of 10 fs with 3-nm normalized emittances, while permitting repetition rates as high as 1.3 GHz. We showed that in conjunction with collimating apertures, a novel focusing scheme achieves very high-quality emittance compensation for the central core of the beam composing 40% of particles, for a resulting beam size of 5 μm (rms). Finally, to aid in the design of new SRF-based ultrafast electron diffraction machines, we simulated the trade-off between the number of cavities used and achievable bunch length and emittance. In the longitudinal dimension, we made use of the fact that MeV UED requires much lower energy than the 15-MeV maxi mum energy of Cornell’s CBETA injector, and we may therefore use several of the SRF cavities for bunch length compression. In practice, we used a genetic optimization algorithm to choose the phases and amplitudes of the cavities appropriately for optimal bunching. In the zero space charge case, we found that bunching and acceleration are distributed across the six cavities in a way that produces a linearizing effect. And we showed that the ultimate bunch length can be limited by time-of-flight differences arising from transverse size and transverse momentum spread. The space charge code developed and used for this development is now permanent part of the Bmad accelerator simulation code and has already contributed to other developments, e.g., for the EIC electron cooler design.

43 PARTICLE ACCELERATORS↗

Thinning and mounting a Texas Instruments 3-phase CCD

Thin CCDs with precise control of thickness and surface quality allow astronomers to optimize chips for specific applications. A means of mechanically thinning a TI 800 x 800 CCD with an abrasive slurry of aluminum oxide is presented. Using the same techniques, the abrasives can be replaced with a chemical solution to eliminate subsurface damage. A technique of mounting the CCD which retains the high quality surface generated during thinning is also demonstrated. This requires the backside of the chip to be bonded to a glass window which closely matches silicon's thermal expansion properties. Thinned CCDs require backside treatment to enhance blue and UV quantum efficiency. Two methods are discussed which may be effective with this mounting system.

Lesser, M. P.↗

Mercury-Cadmium-Telluride Focal Plane Array Performance Under Non-Standard Operating Conditions

This paper highlights a new technique that allows the Teledyne Scientific & Imaging LLC TCM6604A Mercury-Cadmium-Telluride (MCT) Focal Plane Array (FPA) to operate at room temperature. The Teledyne MCT FPA has been a standard in Imaging Spectroscopy since its creation in the 1980's. This FPA has been used in applications ranging from space instruments such as CRISM, M3 and ARTEMIS to airborne instruments such as MaRS and the Next Generation AVIRIS Instruments1. Precise focal plane alignment is always a challenge for such instruments. The current FPA alignment process results in multiple cold cycles requiring week-long durations, thereby increasing the risk and cost of a project. These alignment cycles are necessary because optimal alignment is approached incrementally and can only be measured with the FPA and Optics at standard operating conditions, requiring a cold instrument. Instruments using this FPA are normally cooled to temperatures below 150K for the MCT FPA to properly function. When the FPA is run at higher temperatures the dark current increases saturating the output. This paper covers the prospect of warm MCT FPA operation from a theoretical and experimental perspective. We discuss the empirical models and physical laws that govern MCT material properties and predict the optimal settings that will result in the best MCT PA performance at 300K. Theoretical results are then calculated for the proposed settings. We finally present the images and data obtained using the actual system with the warm MCT FPA settings. The paper concludes by emphasizing the strong positive correlation between the measured values and the theoretical results.

Focal Plane Array (FPA)↗

Optimal 1D Ly α forest power spectrum estimation – I. DESI-lite spectra

ABSTRACT The 1D Ly α forest flux power spectrum P1D is sensitive to scales smaller than a typical galaxy survey, and hence ties to the intergalactic medium’s thermal state, suppression from neutrino masses, and new dark matter models. It has emerged as a competitive framework to study new physics, but also has come with various challenges and systematic errors in analysis. In this work, we revisit the optimal quadratic estimator for P1D, which is robust against the relevant problems such as pixel masking, time evolution within spectrum, and quasar continuum errors. We further improve the estimator by introducing a fiducial power spectrum, which enables us to extract more information by alleviating the discreteness of band powers. We meticulously apply our method to synthetic Dark Energy Spectroscopic Instrument (DESI) spectra and demonstrate how the estimator overcomes each challenge. We further apply an optimization scheme that approximates the Fisher matrix to three elements per row and reduces computation time by 60 per cent. We show that we can achieve per cent precision in P1D with 5-yr DESI data in the absence of systematics and provide forecasts for different spectral qualities.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of dislocation configurations in SiC crystals through X-ray topography aided by ray tracing simulations

Silicon carbide as a wide bandgap semiconductor is of great research interest for its widespread deployment in a range of electronic and optoelectronic devices, particularly in power electronics. However, defects in silicon carbide crystals are still major concerns that is hampering the development of high-performance devices. X-ray topography, particularly using the synchrotron beam has been instrumental in characterizing and analyzing defect configurations in silicon carbide crystals to optimize crystal growth as well as understand the effect of defects on device performance. Here, in recent years, the use of ray-tracing simulation technique based on the orientation contrast mechanism to simulate contrast of defects observed on actual X-ray topographs has proven to be an effective approach to investigate the nature of crystallographic defects in various semiconductors. This review discusses the principle of ray-tracing simulation and its application and modifications to incorporate the effects of surface relaxation and photoelectric absorption to better simulate different dislocations observed in 4H–SiC as well as 6H–SiC crystals of various orientations. The adaptation to weak beam topography and plane wave topography is also discussed. The application of ray-tracing simulation in dislocation characterization of silicon carbide of different polytypes is systematically reviewed including different types of dislocations observed in both off-axis wafers and axial-sliced samples through synchrotron X-ray topography under various beam conditions, recording geometries and reflections. The result of ray-tracing simulation is further utilized in other studies including the investigation of effective penetration depth of all types of dislocations lying on the basal plane on grazing-incidence X-ray topography.

Engineering↗

Advancing conventional High-Resolution Electron Microscopy

Due to the exceptional performance of most modern commercial transmission electron microscopes, the achievement of phase-contrast imaging resolution in the sub-2Å range is today a routine exercise, provided the samples are compliant. Nonetheless, there remains room for improvement, and the purpose of this manuscript is to highlight procedures that might be employed by the practicing microscopist for advancing conventional high resolution electron microscopy.

440800* -- Miscellaneous Instrumentation-- (1990-)↗

Mixed-precision iterative refinement using tensor cores on GPUs to accelerate solution of linear systems

Double-precision floating-point arithmetic (FP64) has been the de facto standard for engineering and scientific simulations for several decades. Problem complexity and the sheer volume of data coming from various instruments and sensors motivate researchers to mix and match various approaches to optimize compute resources, including different levels of floating-point precision. In recent years, machine learning has motivated hardware support for half-precision floating-point arithmetic. A primary challenge in high-performance computing is to leverage reduced-precision and mixed-precision hardware. We show how the FP16/FP32 Tensor Cores on NVIDIA GPUs can be exploited to accelerate the solution of linear systems of equations Ax = b without sacrificing numerical stability. The techniques we employ include multiprecision LU factorization, the preconditioned generalized minimal residual algorithm (GMRES), and scaling and auto-adaptive rounding to avoid overflow. We also show how to efficiently handle systems with multiple right-hand sides. On the NVIDIA Quadro GV100 (Volta) GPU, we achieve a 4×-5× performance increase and 5× better energy efficiency versus the standard FP64 implementation while maintaining an FP64 level of numerical stability.

GMRES↗

Optics-on-a-chip for ultrafast manipulation of 350-MHz hard x-ray pulses

Microelectromechanical systems (MEMS) are miniature devices integrated into a vast range of industrial and consumer applications. Optical MEMS are developed for dynamic spatiotemporal control in lightwave manipulation and communication as modulators, switches, multiplexers, spectrometer, etc. However, they have not been shown to function similarly in sub-nm wavelength regimes, namely, with hard x-rays, as high-brilliance pulsed x-rays have proven powerful for addressing challenges in time-domain science, from energy conversion to neurobiological control. While desirable temporal properties of x-ray pulses can be enhanced by optics, conventional x-ray optics are inherently massive in size, hence, never dynamic. We demonstrate highly ultrafast x-ray optics-on-a-chip based on MEMS capable of modulating hard x-ray pulses exceeding 350 MHz, 10 3 × higher than any other mechanical modulator, with a pulse purity >10 6 without compromising the spectral brilliance. Moreover, the timing characteristics of the devices can be tuned on-the-fly to deliver optimal pulse properties to create a host of dynamic x-ray instruments and applications, impossible with traditional optics of 10 9 × bulkier and more massive. The advent of the ultrafast optics-on-a-chip heralds a new paradigm of x-ray photonics, time-domain science, and accelerator diagnostics, especially at not only the future-generation light sources that offer coherent and high-frequency pulses but also lab-based facilities that normally do not offer timing structures.

42 ENGINEERING↗

Modern fluid dynamics of subsonic and transonic flight

The paper discusses a number of factors, termed research drivers, which are expected to provide much of the stimulus for research in the subsonic and transonic flight regimes in the coming decade. The research drivers discussed comprise the need for energy efficiency, new and improved facilities, better instrumentation, more capable and efficient computers, theoretical methodology refinements, increased use of optimization techniques, and military requirements. Illustrations of advances in aircraft aerodynamics at subsonic and transonic speeds are presented, along with a discussion of future research opportunities and trends. Particular attention is given to airfoil and basic fluids research designed to reduce skin-friction drag.

Bobbitt, P. J.↗

Genesis Noble Gas Measurements

The original thrust of our Genesis funding was to extend and refine the noble gas analytical capabilities of this laboratory to improve the precision and accuracy of noble gas measurements in order to optimize the scientific return from the Genesis Mission. This process involved both instrumental improvement (supplemented by a SRLIDAP instrument grant) and refinement of technique. The Genesis landing mishap shifted our emphasis to the irregular aluminum heat shield material from the flat collector wafers. This has required redesign of our laser extraction cells to accommodate the longer focal lengths required for laser extraction from non-flat surfaces. Extraction of noble gases from solid aluminum surfaces, rather than thin coatings on transparent substrates has required refinement of controlled-depth laser ablation techniques. Both of these bring new problems, both with potentially higher blanks form larger laser cells and the larger quantities of evaporated aluminum which can coat the sapphire entrance ports. This is mainly a problem for the heavy noble gases where larger extraction areas are required, necessitating the new aluminum vapor containment techniques described below. With the Genesis Mission came three new multiple multiplier noble gas mass spectrometers to this laboratory, one built solely by us (Supergnome-M), one built in collaboration with Nu-Instruments (Noblesse), and one built in collaboration with GVI (Helix). All of these have multiple multiplier detection sections with the Nu-Instruments using a pair of electrostatic quad lenses for isotope spacing and the other two using mechanically adjustable positions for the electron multipliers. The Supergnome-M and Noblesse are installed and running. The GVI instrument was delivered a year late (in March 2005) and is yet to be installed by GVI. As with all new instruments there were some initial development issues, some of which are still outstanding. The most serious of these are performance issues with the miniature channel electron multipliers. The delayed installation of Helix by the GVI is partly due to failure of the initial batch of Burle channel multipliers to perform as expected. A number of the channel multipliers designed for Noblesse by Burle have also failed upon baking. Burle has now refined the design of these and we have installed two of the new multipliers and are assessing their performance. The remaining multipliers Will be upgraded to the new design from Burle once we confirm that the problem has been fixed.

Hohenberg, Charles M.↗

Spitzer Observatory Operations -- Increasing Efficiency in Mission Operations

This paper explores the how's and why's of the Spitzer Mission Operations System's (MOS) success, efficiency, and affordability in comparison to other observatory-class missions. MOS exploits today's flight, ground, and operations capabilities, embraces automation, and balances both risk and cost. With operational efficiency as the primary goal, MOS maintains a strong control process by translating lessons learned into efficiency improvements, thereby enabling the MOS processes, teams, and procedures to rapidly evolve from concept (through thorough validation) into in-flight implementation. Operational teaming, planning, and execution are designed to enable re-use. Mission changes, unforeseen events, and continuous improvement have often times forced us to learn to fly anew. Collaborative spacecraft operations and remote science and instrument teams have become well integrated, and worked together to improve and optimize each human, machine, and software-system element.

operational efficiency↗