Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Individual Differences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Accelerate Nuclear Research and Development by Reducing Time and Cost Spend in the Pre-conceptual Design Phase of Advanced Reactor Experiments

The design process of every new concept, such as advanced nuclear reactors or associated experiments, starts with the pre-conceptual design phase. In this phase, the viability of a wide range of design options needs to be assessed quickly, to understand the operating envelope and its feasibility. A variety of physics models (thermal-hydraulics, neutronics, mechanical design, etc.) has to be considered at this very first design stage and optimum component sizes and materials (e.g. heat exchangers, piping, turbomachinery, coolant type, etc.) have to be chosen for a given set of boundary conditions (e.g. heat source, heat sink, flow rate, etc.). Detailed solutions such as provided by high fidelity methods like computational fluid dynamics (CFD), Monte Carlo methods, etc. and even lower fidelity tools such as system or subchannel codes, etc. are usually not used during the pre-conceptual design due to the relatively long time needed to create input models, the computational time to obtain a solution and the lack of flexibility to quickly investigate different combinations of components, individual component sizes and material properties. High fidelity tools are usually only employed in the conceptual design and later phases once a base concept has been identified during the pre-conceptual design stage. The current practice during the pre-conceptual design stage is that analysts collect the needed equations, material properties, closure laws, etc. and create ad-hoc solutions form scratch for every new problem. There clearly is a lack of a flexible scoping tool that can be used during pre-conceptional design before higher fidelity tools (as described above) come into play. To reduce user errors in ad-hoc solutions and increase fidelity and efficiency, this project aims to investigate and develop a user-friendly scoping tool to address the thermal-hydraulic designing needs during preconceptual experiment design, i.e. Thermal-hydraulic Research Universal Scoping Tool (TRUST). The success of TRUST will provide the nuclear engineers with an easy-to-use and affordable calculator for early reactor system design and optimization.

42 ENGINEERING↗

Devices and methods for increasing the speed and efficiency at which a computer is capable of modeling a plurality of random walkers using a particle method

A method for increasing a speed or energy efficiency at which a computer is capable of modeling a plurality of random walkers. The method includes defining a virtual space in which a plurality of virtual random walkers will move among different locations in the virtual space. The method also includes either assigning a corresponding set of ringed neurons in a spiking neural network to a corresponding virtual random walker, or assigning a corresponding set of ringed neurons to a point in the virtual space. Movement of a given virtual random walker is tracked by decoding differences between states of individual neurons in a corresponding given set of ringed neurons. A virtual random walk of the plurality of virtual random walkers is executed using the spiking neural network.

Aimone, James Bradley↗

Distributed Embedded Energy Converter Technologies (DEEC-Tec)

Distributed Embedded Energy Converter Technologies (also known as DEEC-Tec) is based upon the amalgamation and combining of numerous, relatively small, distributed embedded energy converters (DEECs) that, in aggregate, can form a larger overall energy harvesting-converting structure. Such DEEC-Tec based structures can be employed to harvest and convert marine renewable energy - e.g., ocean waves - into more desirable forms such as electricity. In this way, the DEEC-Tec hierarchy can be viewed via three different technology levels: (1) individual distributed embedded energy converters, (2) DEEC-Tec metamaterials (pseudo-materials made from the interconnection of many DEECs), and (3) DEEC-Tec-based marine energy converters built from DEEC-Tec metamaterials.

BFSF↗

ENDF/B-VIII.0 testing with AMPX and SCALE

As the new ENDF/B-VIII.0 data has continued development from its initial beta release into the final release version, it has subsequently undergone processing and testing at Oak Ridge National Laboratory with AMPX and SCALE. Each of the beta releases has been processed with AMPX to create both multigroup (MG) and continuous-energy (CE) libraries. The MG libraries were all processed using the SCALE 252-group structure. These libraries were then used with the VALID suite for benchmarking the new data library's performance against the currently distributed ENDF/B-VII.1 (VII.1)-based SCALE libraries. Here, we compare the MG and CE VALID results for the two current ENDF releases, versions VII.1 and the most recent beta release of ENDF/B-VIII.0 as of this writing (VIII.0.β4). Generally, both the MG and CE VALID aggregate results for VIII.0.β4 compare reasonably well with their VII.1-derived counterparts. As can be expected of any new ENDF release, some of the individual cases have substantially different computed neutron multiplicity (k{sub eff}) values between the two releases, although typically the differences are less than 100 percent-milli (pcm). However, changes to the plutonium cross sections have induced much larger changes in the ratio of the computed k{sub eff} to the experimental value (C/E) for thermal spectrum plutonium solution critical systems. This paper details the comparative performance of the VII.1 and VIII.0.β4 data for the broad range of test cases covered by the VALID suite. A companion paper at this conference provides details of the baseline validation of SCALE 6.2, including the first release of the VII.1 data. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of Kinetic Parameters by Oscillated Experiments

The availability of reliable values of the kinetic parameters (effective delayed neutron fraction {beta} and effective mean neutron generation time {Lambda}) is important for reactor kinetic analyses and for reactivity monitoring when adopting the point kinetic approach. The kinetic parameters may be obtained either by simulations (Monte Carlo or deterministic) of the system or by direct measurements. Several methods have been proposed for the direct experimental determination of the kinetic parameters, e.g. control rod drops and noise analysis approaches, e.g. In this work, the problem of the determination of kinetic parameters in subcritical systems is tackled. The system is subjected to an oscillated source and the value of the ratio {beta}/{Lambda} is related to a measurable quantity when the system response reaches an equilibrium condition. In the analysis presented, a pure frequency is considered: when analyzing more complicated source periodic behaviours, a Fourier analysis can allow to isolate the contributions of individual frequencies. The phase difference between the oscillating source and the system response is adopted as the experimental observable. The method for the interpretation of the measurements is based on the standard point kinetic model. The response of the system is obtained by localized neutron detectors and, therefore, spatial and spectral effects may also affect the results. This drawback needs some further discussion and will be considered in the future work. The phase shift between the source signal and the system response may be analytically retrieved by Laplace transforming the point kinetic equations in the presence of an oscillated source. An explicit formula relates the phase shift to the ratio {beta}/{Lambda} and to the frequency of the source. Based on this relationship, the ratio {beta}/{Lambda} can be determined. To validate the technique, the experimental data are simulated by a numerical code solving the time-dependent diffusion equations for a source-driven system. The work allows to assess the possibility of the technique and its limits of applicability. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimal coupler and power setting for superconductive linear accelerators

The modeling analysis presented in this paper addresses the question of how to achieve the highest vector sum gradient for all beam currents when individual cavities operate at different gradients due to their inherent quenching limitations. The analytical method explained here constitutes a step forward toward the operability of the International Linear Collider (ILC), Project X [8], or XFEL [7]. Unlike previously proposed methods [1, 2], this approach prevents cavities from quenching should the beam current be lower than its maximum value.

43 PARTICLE ACCELERATORS↗

From Existing and New Nuclear and Astrophysical Constraints to Stringent Limits on the Equation of State of Neutron-Rich Dense Matter

Through continuous progress in nuclear theory and experiment and an increasing number of neutron-star (NS) observations, a multitude of information about the equation of state (EOS) for matter at extreme densities is available. To constrain the EOS across its entire density range, this information needs to be combined consistently. However, the impact and model dependency of individual observations vary. Given their growing number, assessing the various methods is crucial to compare the respective effects on the EOS and discover potential biases. For this purpose, we present a broad compendium of different constraints and apply them individually to a large set of EOS candidates within a Bayesian framework. Specifically, we explore different ways of how chiral effective field theory and perturbative quantum chromodynamics can be used to place a likelihood on EOS candidates. We also investigate the impact of nuclear experimental constraints, as well as different radio and x-ray observations of NS masses and radii. This is augmented by reanalyses of the existing data from binary neutron star coalescences, in particular of GW170817, with improved models for the tidal waveform and kilonova light curves, which we also utilize to construct a tight upper limit of 2.39 M ⊙ on the TOV mass based on GW170817’s remnant. Our diverse set of constraints is eventually combined to obtain stringent limits on NS properties. We organize the combination in a way to distinguish between constraints where the systematic uncertainties are deemed small and those that rely on less conservative assumptions. For the former, we find the radius of the canonical 1.4 M ⊙ neutron star to be R 1.4 = 12.2 6 − 0.91 + 0.80 km and the TOV mass at M TOV = 2.2 5 − 0.22 + 0.42 M ⊙ (95% credibility). Including all the presented constraints yields R 1.4 = 12.2 0 − 0.48 + 0.50 km and M TOV = 2.3 0 − 0.20 + 0.07 M ⊙ . When comparing these limits to individual data points, we find that the quoted radius of HESS J1731-347 displays noticeable tension with other constraints. Constraining microphysical properties of the EOS proves more challenging. For instance, the symmetry energy slope is restricted to L sym = 48 − 25 + 21 MeV , where this constraint is mainly dominated by our reanalysis of the PREX-II and CREX experiment. Published by the American Physical Society 2025

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity study of voxel-based PET image comparison to image registration algorithms

Purpose: Accurate deformable registration is essential for voxel-based comparison of sequential positron emission tomography (PET) images for proper adaptation of treatment plan and treatment response assessment. The comparison may be sensitive to the method of deformable registration as the optimal algorithm is unknown. This study investigated the impact of registration algorithm choice on therapy response evaluation. Methods: Sixteen patients with 20 lung tumors underwent a pre- and post-treatment computed tomography (CT) and 4D FDG-PET scans before and after chemoradiotherapy. All CT images were coregistered using a rigid and ten deformable registration algorithms. The resulting transformations were then applied to the respective PET images. Moreover, the tumor region defined by a physician on the registered PET images was classified into progressor, stable-disease, and responder subvolumes. Particularly, voxels with standardized uptake value (SUV) decreases >30% were classified as responder, while voxels with SUV increases >30% were progressor. All other voxels were considered stable-disease. The agreement of the subvolumes resulting from difference registration algorithms was assessed by Dice similarity index (DSI). Coefficient of variation (CV) was computed to assess variability of DSI between individual tumors. Root mean square difference (RMS{sub rigid}) of the rigidly registered CT images was used to measure the degree of tumor deformation. RMS{sub rigid} and DSI were correlated by Spearman correlation coefficient (R) to investigate the effect of tumor deformation on DSI. Results: Median DSI{sub rigid} was found to be 72%, 66%, and 80%, for progressor, stable-disease, and responder, respectively. Median DSI{sub deformable} was 63%–84%, 65%–81%, and 82%–89%. Variability of DSI was substantial and similar for both rigid and deformable algorithms with CV > 10% for all subvolumes. Tumor deformation had moderate to significant impact on DSI for progressor subvolume with R{sub rigid} = − 0.60 (p = 0.01) and R{sub deformable} = − 0.46 (p = 0.01–0.20) averaging over all deformable algorithms. For stable-disease subvolumes, the correlations were significant (p < 0.001) for all registration algorithms with R{sub rigid} = − 0.71 and R{sub deformable} = − 0.72. Progressor and stable-disease subvolumes resulting from rigid registration were in excellent agreement (DSI > 70%) for RMS{sub rigid} < 150 HU. However, tumor deformation was observed to have negligible effect on DSI for responder subvolumes with insignificant |R| < 0.26, p > 0.27. Conclusions: This study demonstrated that deformable algorithms cannot be arbitrarily chosen; different deformable algorithms can result in large differences of voxel-based PET image comparison. For low tumor deformation (RMS{sub rigid} < 150 HU), rigid and deformable algorithms yield similar results, suggesting deformable registration is not required for these cases.

60 APPLIED LIFE SCIENCES↗

Rapid Relaxation and Embrittlement of Zr-based Bulk Metallic Glasses by Electropulsing

Mechanical relaxation and embrittlement of Zr52.5Cu17.9Ni14.6Al10Ti5 bulk metallic glasses were achieved rapidly by the direct current electropulsing treatment. The temperature profile was recorded by an infrared camera and it was found to be non-uniform in the treated specimen. Specifically, temperatures below the glass transition temperature, near and above the crystallization temperature could be ach- ieved, respectively, at different locations in the same treated specimen. Two sets of nanoindentation were conducted. While the first set investigated the mechanical properties of three individually elec- tropulsed specimens with different conditions, the second set indented a single treated specimen along its temperature gradient. Both sets of indentation revealed that by Joule heating to different tempera- tures, relaxation, embrittlement, and crystallization were significantly accelerated by electrical pulses. Results suggest that electropulsing provides an opportunity to simultaneously achieve plastic forming and mechanical property control of metallic glasses.

Yiu, P↗

InterCarb: A Community Effort to Improve Interlaboratory Standardization of the Carbonate Clumped Isotope Thermometer Using Carbonate Standards

Abstract Increased use and improved methodology of carbonate clumped isotope thermometry has greatly enhanced our ability to interrogate a suite of Earth‐system processes. However, interlaboratory discrepancies in quantifying carbonate clumped isotope (Δ 47 ) measurements persist, and their specific sources remain unclear. To address interlaboratory differences, we first provide consensus values from the clumped isotope community for four carbonate standards relative to heated and equilibrated gases with 1,819 individual analyses from 10 laboratories. Then we analyzed the four carbonate standards along with three additional standards, spanning a broad range of δ 47 and Δ 47 values, for a total of 5,329 analyses on 25 individual mass spectrometers from 22 different laboratories. Treating three of the materials as known standards and the other four as unknowns, we find that the use of carbonate reference materials is a robust method for standardization that yields interlaboratory discrepancies entirely consistent with intralaboratory analytical uncertainties. Carbonate reference materials, along with measurement and data processing practices described herein, provide the carbonate clumped isotope community with a robust approach to achieve interlaboratory agreement as we continue to use and improve this powerful geochemical tool. We propose that carbonate clumped isotope data normalized to the carbonate reference materials described in this publication should be reported as Δ 47 (I‐CDES) values for Intercarb‐Carbon Dioxide Equilibrium Scale.

58 GEOSCIENCES↗

Superresolved Motions of Single Molecular Catalysts during Polymerization Show Wide Distributions

The motion of single molecular ruthenium catalysts during and after single turnover events of ring-opening metathesis polymerization is imaged through single-molecule superresolution tracking with a positional accuracy of ±32 nm. This tracking is achieved through the real-time incorporation of spectrally tagged monomer units into active polymer chain ends during living polymerization; thus, by design, only active-catalyst motion is detected and imaged, without convolution by inactive catalysts. The catalysts show diverse individualistic diffusive behaviors with respect to time that persist for up to 20 s. Catalysts occupy three mobility populations: quasi-stationary (23%), intermediate (53%, 65 nm), and large (24%, 145 nm) step sizes. Differences in catalyst mobility populations also exist between individual aggregates (p < 0.001). Such differential motion indicates widely different local catalyst microenvironments during the catalytic turnover. These mobility differences are uniquely observable through single-catalyst microscopy and are not measurable through traditional ensemble analytical techniques for characterizing the behavior of molecular catalysts, such as nuclear magnetic resonance spectroscopy. The measured distributions of active molecular catalyst motions would not be readily predictable through modeling or first-principles, and the range likely impacts individual catalyst turnover rate and selectivity. This range plausibly contributes to property distributions observable in bulk polymers, such as molecular weight polydispersity (e.g., 1.9 in this system), leading to a revised understanding of the mechanistic, microscale origins of macroscale polymer properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous probing of phase transformations in Ni-Ti thin film shape memory alloy by synchrotron radiation-based X-ray diffraction and electrical resistivity

Nickel–Titanium (Ni–Ti) thin film shape memory alloys (SMAs) have been widely projected as novel materials which can be utilized in microdevices. Characterization of their physical properties and its correlation with phase transformations has been a challenging issue. In the present study, X-ray beam diffraction has been utilized to obtain the structural information at different temperatures while cooling. Simultaneously, electrical resistivity (ER) was measured in the phase transformation temperature range. The variation of ER and integral area of the individual diffraction peaks of the different phases as a function of temperature have been compared. A mismatch between the conventional interpretation of ER variation and the results of the XRD data has been clearly identified. - Highlights: ► Phase transformation characterization of Ni–Ti thin film SMA has been carried out. ► Simultaneous monitoring of the XRD and ER with temperature is performed. ► The variation of ER and integral area of the diffraction peaks have been compared. ► A shift of the transformation temperatures obtained by two techniques is discussed.

36 MATERIALS SCIENCE↗

Forest response to rising CO 2 drives zonally asymmetric rainfall change over tropical land

Understanding how anthropogenic CO 2 emissions will influence future precipitation is critical for sustainably managing ecosystems, particularly for drought-sensitive tropical forests. Although tropical precipitation change remains uncertain, nearly all models from the Coupled Model Intercomparison Project Phase 5 predict a strengthening zonal precipitation asymmetry by 2100, with relative increases over Asian and African tropical forests and decreases over South American forests. Here we show that the plant physiological response to increasing CO 2 is a primary mechanism responsible for this pattern. Applying a simulation design in the Community Earth System Model in which CO 2 increases are isolated over individual continents, we demonstrate that different circulation, moisture and stability changes arise over each continent due to declines in stomatal conductance and transpiration. The sum of local atmospheric responses over individual continents explains the pan-tropical precipitation asymmetry. Our analysis suggests that South American forests may be more vulnerable to rising CO 2 than Asian or African forests.

54 ENVIRONMENTAL SCIENCES↗

Large Individual Ion FTICR Measurements from the Mid-1990s Using Reactions for Charge Determination Mass Spectrometry

This article discusses from a personal and present-day perspective the first studies of large highly charged individual molecular ions that were conducted using electrospray ionization (ESI) with Fourier transform ion cyclotron resonance (FTICR) MS in the mid-1990s. These studies are distinguished from current Charge Detection Mass Spectrometry (CDMS) research primarily by their use of individual ion charge state changes due to reactions. Here this work describes the key differences in technologies and methods with present CDMS, and the likely implications of these differences. I also comment on surprising individual ion behavior observed in some measurements involving increases in charge state, as well as their possible basis, and also briefly discuss the potential utility of the reaction-based mass measurement approach used in the context of what might more globally be referred to as ‘Charge Determination Mass Spectrometry’.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Species- and element-specific patterns of metal flux from contaminated wetlands versus metals shed with exuviae in emerging dragonflies

Dragonfly adults and their aquatic immature stages are important parts of food webs and provide a link between aquatic and terrestrial components. During emergence, contaminants can be exported into terrestrial food webs as immature adults fly away or be shed with their exuviae and remain in the wetland. Our previous work established metals accumulating in dragonfly nymphs throughout a contaminated constructed wetland designed to regulate pH and sequester trace metals from an industrial effluent line. In this paper we evaluated the concentration and mass of metals leaving the wetland in flying emergents versus remaining in the wetland with the shed exuviae in 10 species of dragonflies belonging to 8 genera. Nine elements (Cu, Zn, Cd, Mn, V, Mg, Fe, Al, Pb) were evaluated that include essential and nonessential elements as well as trace and major metals. Metal concentrations in the emergent body and exuviae can differ by orders of magnitude. Aluminum, Fe, Mn, and Pb were largely shed in the exuviae. Vanadium and Cd were more variable among species but also tended to be shed with the exuviae. In contrast, Cu, Zn, and Mg showed a higher tendency to leave the wetland with an emerging dragonfly. Metals shed in dragonfly exuviae can moderate the transport of metals from contaminated wetlands. Taxonomic- and metal-specific variability in daily metal flux from the wetland depended upon concentration accumulated, individual body mass, and number of individuals emerging, with each factor's relative importance often differing among species. This illustrates the importance of evaluating the mass of metals in an individual and not only concentrations. Furthermore, differences in numbers of each species emerging will magnify differences in individual metal flux when calculating community metal flux. A better understanding of the variability of metal accumulation in nymphs/larvae and metal shedding during metamorphosis among both metals and species is needed.

54 ENVIRONMENTAL SCIENCES↗

Modelling and experimental study of temperature profiles in cw laser diode bars

Three-dimensional simulation is used to theoretically assess temperature profiles in proposed 10-mm-wide cw laser diode bars packaged in a standard heat spreader of the C – S mount type with the aim of raising their reliable cw output power. We obtain calculated temperature differences across the emitting aperture and along the cavity. Using experimental laser bar samples with up to 60 W of cw output power, the emission spectra of individual clusters are measured at different pump currents. We compare and discuss the simulation results and experimental data. The bibliography includes 9 references. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-605: A New Design for a Rotating Gamma Knife. Monte Carlo Simulation

Purpose: to determine the characteristics of the 60Co beam emerging from a new design of a rotating Gamma Knife system and to calculate 3D dose distributions at the isocenter for different source configurations and collimator openings. Methods: We employed the BEAM-Monte Carlo code to realistically model the geometry design, including 30 60Co source capsules, two circular primary collimators (diameter of 6.6mm and 6.1mm) and four different changeable collimators. The shielding of the head design was also simulated. The sources (2.8mm diameter) are distributed in six groups in the spherical geometry. Each source is individually collimated to obtained four different circular fields at the isocenter (3mm, 3.5mm, 6mm and 8mm).The phase-space particles reaching the scoring plane below the primary collimation assembly were recorded and the BEAMDP code was used to determine the fluence and energy spectra of the particles emerging from each source-collimator configuration. The dose distributions at the isocenter plane (397.6mm from the source) were calculated in a spherical component module for the circular field sizes studied. Results: The energy spectra below the head assembly and primary collimators have been obtained, which exhibited the typical 60Co peaks and a small low-energy tail due to scattered photons (from about 200keV to 1MeV). The scattered component of the spectra represents about 8 % of the total number of photons reaching the scoring plane. The radial photon fluence does not vary significantly inside the collimator openings. The spectra of particles from different source groups are compared. Conclusion: The 60Co beam emerging from each source configuration was characterized, which can be used to establish a generic source model for all the sources for fast MC dose calculation. Further investigations are needed to determine the dose variations as a result of partial switching on/off different groups of sources for advanced Gamma Knife SRS/SBRT planning.

07 ISOTOPE AND RADIATION SOURCES↗

Initial Comparison of Baseline Physical and Mechanical Properties for the VHTR Candidate Graphite Grades

High-purity graphite is the core structural material of choice in the Very High Temperature Reactor (VHTR) design, a graphite-moderated, helium-cooled configuration capable of producing thermal energy for power generation as well as process heat for industrial applications that require temperatures higher than the outlet temperatures of present nuclear reactors. The Baseline Graphite Characterization Program is establishing accurate as-manufactured mechanical and physical property distributions in nuclear-grade graphites by providing comprehensive data that captures the level of variation in measured values. In addition to providing a thorough comparison between these values in different graphite grades, the program is also carefully tracking individual specimen source, position, and orientation information in order to provide comparisons both in specific properties and in the associated variability between different lots, different billets, and different positions from within a single billet. This report is a preliminary comparison between each of the grades of graphite that are considered “candidate” grades from four major international graphite producers. These particular grades (NBG-18, NBG-17, PCEA, IG-110, and 2114) are the major focus of the evaluations presently underway on irradiated graphite properties through the series of Advanced Graphite Creep (AGC) experiments. NBG-18, a medium-grain pitch coke graphite from SGL from which billets are formed via vibration molding, was the favored structural material in the pebble-bed configuration. NBG-17 graphite from SGL is essentially NBG-18 with the grain size reduced by a factor of two. PCEA, petroleum coke graphite from GrafTech with a similar grain size to NBG-17, is formed via an extrusion process and was initially considered the favored grade for the prismatic layout. IG-110 and 2114, from Toyo Tanso and Mersen (formerly Carbone Lorraine), respectively, are fine-grain grades produced via an isomolding process. An analysis of the comparison between each of these grades will include not only the differences in fundamental and statistically-significant individual strength levels, but also the differences in the overall variability in properties within each of the grades that will ultimately provide the basis for predicting in-service performance. The comparative performance of the different types of nuclear-grade graphites will naturally continue to evolve as thousands more specimens are fully characterized with regard to strength, physical properties, and thermal performance from the numerous grades of graphite being evaluated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗