Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Top-down mass spectrometry and assigning internal fragments for determining disulfide bond positions in proteins

Disulfide bonds in proteins have a substantial impact on protein structure, stability, and biological activity. Localizing disulfide bonds is critical for understanding protein folding and higher-order structure. Conventional top-down mass spectrometry (TD-MS), where only terminal fragments are assigned for disulfide-intact proteins, can access disulfide information, but suffers from low fragmentation efficiency, thereby limiting sequence coverage. Here, we show that assigning internal fragments generated from TD-MS enhances the sequence coverage of disulfide-intact proteins by 20–60% by returning information from the interior of the protein sequence, which cannot be obtained by terminal fragments alone. Further, the inclusion of internal fragments can extend the sequence information of disulfide-intact proteins to near complete sequence coverage. Importantly, the enhanced sequence information that arise from the assignment of internal fragments can be used to determine the relative position of disulfide bonds and the exact disulfide connectivity between cysteines. The data presented here demonstrates the benefits of incorporating internal fragment analysis into the TD-MS workflow for analyzing disulfide-intact proteins, which would be valuable for characterizing biotherapeutic proteins such as monoclonal antibodies and antibody–drug conjugates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overview of the OECD-NEA Working Party on International Nuclear Data Evaluation Cooperation (WPEC)

The OECD Nuclear Energy Agency (NEA) Working Party on International Nuclear Data Evaluation Cooperation (WPEC) was established in 1989 to facilitate collaboration in nuclear data activities. Over its thirty year history, different Subgroups have been created to address topics in nearly every aspect of nuclear data, including: experimental measurements, evaluation, validation, model development, quality assurance of databases and the development of software tools. WPEC has recently completed activities on fission yield evaluation, the general nuclear database structure (GNDS) to replace the ENDF-6 format, methods to provide feedback to evaluation, studies of specific capture cross sections, new methods in thermal scattering kernel evaluation and the Collaborative International Evaluated Library Organisation (CIELO) Pilot Project. Ongoing activities in GNDS application programming interface (API) development, methods for covariance evaluation and quality assurance in nuclear data validation using the International Criticality Safety Benchmark Evaluation Project (ICSBEP) database are complemented by the work of two Expert Groups that oversee the High-Priority Request List (HPRL) for Nuclear Data and the continuous development of the GNDS. New activities on the use of integral experiments for nuclear data validation and adjustment, as well as the use of the Shielding Integral Benchmark Archive and Database (SINBAD) for validation have begun and will be coordinated alongside future Subgroups. After three decades we will review the status of WPEC, how it integrates other collections and activities organised by the NEA and how it dovetails with the initiatives of the IAEA and other bodies to effectively coordinate international activities in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The International Framework for Maintaining Equivalence and Traceability in Radionuclide Metrology

Confidence that a testing or calibration laboratory consistently obtains reliable results is of major importance to users of laboratory services and participation in proficiency testing schemes provides laboratories with an objective means of assessing and demonstrating the level of confidence that can be ascribed to the reliability of the data they are producing. That level of confidence, in turn, depends on the quality of the proficiency tests and, in particular, on the accuracy of the property values associated with the test samples. In the ideal situation, the relevant property value, such as the activity of a particular radionuclide in a test matrix, will be directly traceable to the SI via comparisons with a national or international metrology institute (NMI). This, in turn, begs the question of, how reliable are the results from that NMI.Demonstration of that reliability at the highest metrological levels is achieved through inter-laboratory comparisons that are conducted between national and international metrological institutes. These are coordinated primarily by the Bureau International des Poids et Mesures (BIPM) via Key Comparisons or by comparisons within Regional Metrological Organisations (RMOs), with the results from those RMO exercises being linked to the BIPM Key Comparison results. Such programmes have been in place for many years but they have grown in importance and frequency over the past decade. Tabulation of these comparison data has been regularized recently and made available to the user communities via the BIPM Key Comparison Database (KCDB).In the field of ionizing radiation, the radionuclide metrology discipline exhibits a number of special features. For example, these include the number of potential radionuclides in a user sample; the variety of physical and chemical formats that may be presented; the statistical and temporal effects of radioactive decay; the variations in primary standardization techniques; and the restricted applicability of those primary standardization techniques to the full range of potential radionuclides and activities. Each of these, singly or in combination, ensure that there can never be a fully comprehensive set of Key Comparisons which will cover the requirements of the user community and, in turn, compromise the ability to provide a full range of proficiency tests for testing and calibration laboratories.These problems are discussed, in the context of radioactivity measurements, together with the structure and range of Key Comparisons and associated databases at the highest international level that are currently in place to underpin the proficiency tests that are necessary for the user communities in this field of application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Hall sensor array for internal current profile constraint

Measurements of the internal distribution of B in magnetically confined plasmas are required to obtain current profiles via equilibrium reconstruction with sufficient accuracy to challenge stability theory. A 16-channel linear array of InSb Hall effect sensors with 7.5 mm spatial resolution has been constructed to directly measure internal B{sub z}(R,t) for determination of J({psi},t) associated with edge-localized peeling mode instabilities in the Pegasus Toroidal Experiment. The diagnostic is mounted in an electrically isolated vacuum assembly which presents a slim, cylindrical profile ({approx}1 cm outside diameter) to the plasma using graphite as a low-Z plasma facing component. Absolute calibration of the sensors is determined via in situ cross-calibration against existing magnetic pickup coils. Present channel sensitivities are of order of 0.25 mT. Internal measurements with bandwidth of {<=}25 kHz have been obtained without measurable plasma perturbation. They resolve n=1 internal magnetohydrodynamics and indicate systematic variation in J({psi}) under different stability conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Center-of-mass and internal symmetries in classical relativistic systems

The internal symmetry of composite relativistic systems is discussed. It is demonstrated that the Lorentz-Poincare symmetry implies the existence of internal moments associated with the Lorentz boost, which are Laplace-Runge-Lenz (LRL) vectors. The LRL symmetry is thus found to be the internal symmetry universally associated with the global Lorentz transformations, in much the same way as internal spatial rotations are associated with global spatial rotations. Two applications are included for an interacting two-body system and for an interaction-free many-body system of particles. The issue of localizability of the relativistic center-of-mass coordinate is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Internal disruptions and sawtooth like activity in Large Helical Device

Large Helical Device (LHD) inward-shifted configurations are unstable to resistive magnetohydrodynamic (MHD) pressure-gradient-driven modes. These modes drive sawtooth like events during LHD operation. In this work, we simulate sawtooth like activity and internal disruptions in order to improve the understanding of these relaxation events and their effect over the device efficiency to confine the plasma, with the aim to improve the LHD present and future operation scenarios minimizing or avoiding the disadvantageous MHD soft and hard limits. By solving a set of reduced non-linear resistive MHD equations, we have studied the evolution of perturbations to equilibria obtained before and after a sawtooth like event in LHD. The equilibrium {beta} value is gradually increased during the simulation until it reaches the experimental value. Sawtooth like events and internal disruption events take place in the simulation for {beta}{sub 0} values between 1% and 1.48%. The main driver of the sawtooth like events is the resonant and non-resonant effect of the (n = 1, m = 3) mode. The instability is stronger for resonant events, and they only appear when {beta}{sub 0} = 1.48%. Internal disruptions are mainly driven by the (n = 1, m = 2) mode, and they extend throughout the whole plasma core. Internal disruption events do not show up when resonant sawtooth like events are triggered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The internal disruption as hard Magnetohydrodynamic limit of 1/2 sawtooth like activity in large helical device

Large helical device (LHD) inward-shifted configurations are unstable to resistive MHD pressure-gradient-driven modes. Sawtooth like activity was observed during LHD operation. The main drivers are the unstable modes 1/2 and 1/3 in the middle and inner plasma region which limit the plasma confinement efficiency of LHD advanced operation scenarios. The aim of the present research is to study the hard MHD limit of 1/2 sawtooth like activity, not observed yet in LHD operation, and to predict its effects on the device performance. Previous investigations pointed out this system relaxation can be an internal disruption [J. Varela et al., 'Internal disruptions and sawtooth like activity in LHD,' 38th EPS Conference on Plasma Physics (2011), P5.077]. In the present work, we simulate an internal disruption; we study the equilibria properties before and after the disruptive process, its effects on the plasma confinement efficiency during each disruptive phase, the relation between the n/m = 1/2 hard MHD events and the soft MHD events, and how to avoid or reduce their adverse effects. The simulation conclusions point out that the large stochastic region in the middle plasma strongly deforms and tears the flux surfaces when the pressure gradient increases above the hard MHD limit. If the instability reaches the inner plasma, the iota profiles will be perturbed near the plasma core and three magnetic islands can appear near the magnetic axis. If the instability is strong enough to link the stochastic regions in the middle plasma (around the half minor radius {rho}) and the plasma core ({rho}<0.25), an internal disruption is driven.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Disparate effects of an O{sub 2} internal impurity on the elongation and quantum transport of gold and silver nanowires

In this work, we investigated the effects of an internal O{sub 2} impurity on the conductance of elongated gold and silver nanowires (NWs) using density functional theory calculations. We found that the O{sub 2} interacts with these metallic NWs very differently. In the case of gold NWs, the presence of an internal oxygen molecule locally strengthens the wire, therefore, forcing the phase transformations connected to the thinning process (3D to 2D and 2D to single atom chain) to occur far from the oxygen. As a consequence, towards the end of the elongation, the internal O{sub 2} is located far from the main conductance channel and therefore has little influence on the conductance of the NW. In contrast, in silver NWs, the presence of an internal oxygen molecule involves a larger charge transfer from the metallic atoms to the oxygen, therefore, weakening the Ag-Ag binding. During the initial stages of the elongation, several metallic bonds adjacent to the impurity break, so that in most simulations the NW thinning takes place near the O{sub 2}. This thinning mechanism places the O{sub 2} near the main conductance channel, therefore, significantly reducing the conductivity of the elongated silver NWs. For both metals, our findings agree well with the published experimental results.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Internal-strain effect on the valence band of strained silicon and its correlation with the bond angles

By means of the first-principles density-functional theory, we investigate the effect of relative atom displacement in the crystal unit cell, namely, internal strain on the valence-band dispersion of strained silicon, and find close correlation of this effect with variation in the specific bond angles due to internal strain. We consider the [111] ([110]) band dispersion for (111) ((110)) biaxial tensility and [111] ([110]) uniaxial compression, because remarkably small values of hole effective mass m* can be obtained in this dispersion. Under the practical condition of no normal stress, biaxial tensility (uniaxial compression) involves additional normal compression (tensility) and internal strain. With an increase in the internal-strain parameter, the energy separation between the highest and second-highest valence bands becomes strikingly larger, and the highest band with conspicuously small m* extends remarkably down to a lower energy region, until it intersects or becomes admixed with the second band. This is closely correlated with the change in the specific bond angles, and this change can reasonably explain the above enlargement of the band separation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Internal additive noise effects in stochastic resonance using organic field effect transistor

Stochastic resonance phenomenon was observed in organic field effect transistor using poly(3-hexylthiophene), which enhances performance of signal transmission with application of noise. The enhancement of correlation coefficient between the input and output signals was low, and the variation of correlation coefficient was not remarkable with respect to the intensity of external noise, which was due to the existence of internal additive noise following the nonlinear threshold response. In other words, internal additive noise plays a positive role on the capability of approximately constant signal transmission regardless of noise intensity, which can be said “homeostatic” behavior or “noise robustness” against external noise. Furthermore, internal additive noise causes emergence of the stochastic resonance effect even on the threshold unit without internal additive noise on which the correlation coefficient usually decreases monotonically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Role of internal motions and molecular geometry on the NMR relaxation of hydrocarbons

The role of internal motions and molecular geometry on 1 H NMR relaxation rates in liquid-state hydrocarbons is investigated using MD (molecular dynamics) simulations of the autocorrelation functions for intramolecular and intermolecular 1 H– 1 H dipole-dipole interactions. The effects of molecular geometry and internal motions on the functional form of the autocorrelation functions are studied by comparing symmetric molecules such as neopentane and benzene to corresponding straight-chain alkanes n-pentane and n-hexane, respectively. Comparison of rigid versus flexible molecules shows that internal motions cause the intramolecular and intermolecular correlation-times to get significantly shorter, and the corresponding relaxation rates to get increasingly smaller, especially for longer-chain n-alkanes. Site-by-site simulations of 1 H’s across the chains indicate significant variations in correlation times and relaxation rates across the molecule, and comparison with measurements reveals insights into cross-relaxation effects. Moreover, the simulations reveal new insights into the relative strength of intramolecular versus intermolecular relaxation as a function of internal motions, as a function of molecular geometry, and on a site-by-site basis across the chain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toroidal modeling of interaction between internal kink mode and plasma flow

Non-linear interaction between the internal kink mode and toroidal plasma rotation is numerically studied using the MARS-Q code. Simulation results show core plasma flow damping due to various toroidal torques, generated by a weakly stable internal kink mode. Here, the 3-D field perturbation induced torques, including the neoclassical toroidal viscous (NTV) torque, as well as that produced by the Maxwell and Reynolds stresses, act as sink terms in the toroidal momentum balance model. The NTV torque is found to play a dominant role in the flow damping in all cases considered in this study. The modification to the internal kink mode structure is observed during the flow damping. Whilst a steady state can be achieved in the coupled mode-flow evolution with a uniform initial flow, a sheared initial flow affects the linear stability of the mode and consequently changes the non-linear evolution. For cases where the steady state solution is achieved, the saturated plasma flow speed critically depends on the initial flow condition as well as the initial amplitude of the internal kink mode but is less sensitive to the on-axis safety factor q0, as long as the latter stays above 1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tissue-specific geometry and chemistry of modern and fossilized melanosomes reveal internal anatomy of extinct vertebrates

Recent discoveries of nonintegumentary melanosomes in extant and fossil amphibians offer potential insights into the physiological functions of melanin not directly related to color production, but the phylogenetic distribution and evolutionary history of these internal melanosomes has not been characterized systematically. Here, we present a holistic method to discriminate among melanized tissues by analyzing the anatomical distribution, morphology, and chemistry of melanosomes in various tissues in a phylogenetically broad sample of extant and fossil vertebrates. Our results show that internal melanosomes in all extant vertebrates analyzed have tissue-specific geometries and elemental signatures. Similar distinct populations of preserved melanosomes in phylogenetically diverse vertebrate fossils often map onto specific anatomical features. This approach also reveals the presence of various melanosome-rich internal tissues in fossils, providing a mechanism for the interpretation of the internal anatomy of ancient vertebrates. Collectively, these data indicate that vertebrate melanins share fundamental physiological roles in homeostasis via the scavenging and sequestering of metals and suggest that intimate links between melanin and metal metabolism in vertebrates have deep evolutionary origins.

59 BASIC BIOLOGICAL SCIENCES↗

MPS dose reconstruction for internal emitters: some site-specific issues and approaches

Background: As part of the Million Person Study (MPS), dose reconstructions for internal emitters have been performed for several U.S. facilities where large quantities of radionuclides were handled. The main challenges and dominant sources of potential error in retrospective dose estimates for internally exposed workers have been found to vary from site to site. Here in this paper, we discuss some important issues encountered in dose reconstructions performed for selected MPS sites and the approaches used to address those issues. The focus is on some foundational components of retrospective dose assessments that have received little attention in the literature. Methods: The discussion is built around illustrative exposure data and dose reconstructions for workers at selected facilities addressed in the MPS. Related findings at some non-MPS sites are also discussed. Results: Each of the following items has been found to be a major source of potential error in reconstructed tissue doses for some MPS sites: identification of all dosimetrically important internal emitters; the time pattern of intake; the mode(s) of intake; reliability of bioassay measurements; application of surrogate (coworker) information in lieu of, or in conjunction with, worker-specific monitoring data; the chemical and physical forms of inhaled radionuclide; and the relation of air monitoring data to actual intake. Conclusions: (1) Much of the dose reconstruction effort for internal emitters should be devoted to development of best feasible exposure scenarios. (2) Coworker data should be used to assign exposure scenarios or dose estimates to workers with missing exposure data only if there is compelling evidence of similar coworker exposure. (3) Bioassay data for some radionuclides and periods of operation at MPS sites are of questionable reliability due to sizable uncertainties associated with contamination, recovery, or background issues. (4) Dose estimates derived solely from air monitoring data should be treated as highly uncertain values in the absence of site-specific information demonstrating that the data are reasonably predictive of intake. (5) For intakes known or assumed to be via inhalation, the uncertainty in lung dose typically is much greater than the uncertainty in dose to systemic tissues, when dose estimates are based on urinary excretion data. (6) The lung dose estimate often can be improved through development of site-specific respiratory absorption parameter values. (7) There is generally insufficient site-specific information to justify development of site-specific systemic models.

61 RADIATION PROTECTION AND DOSIMETRY↗

Export Controls and International Safeguards: Strengthening Nonproliferation through Interdisciplinary Integration

International safeguards and export controls are central to ensuring international confidence in the peaceful uses of nuclear materials and technologies and to achieving adequate oversight on the transfer and use of nuclear materials, technology, and equipment required for the development of proliferation-sensitive parts of the nuclear fuel cycle. Although the independent strengths of international safeguards and export controls rely largely on universal adherence, there may be opportunities to exploit the shared strengths of these systems. This article provides background information on the separate evolution of export controls and international safeguards, considers how these two elements of the nonproliferation regime interact, and identifies some possible avenues that could, over time, lead to wholly integrated activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THE ROLE OF NEWLY BORN MAGNETARS IN GAMMA-RAY BURST X-RAY AFTERGLOW EMISSION: ENERGY INJECTION AND INTERNAL EMISSION

Swift observations suggest that the central compact objects of some gamma-ray bursts (GRBs) could be newly born millisecond magnetars. Therefore, considering the spin evolution of the magnetars against r-mode instability, we investigate the role of magnetars in GRB X-ray afterglow emission. Besides modifying the conventional energy injection model, we pay particular attention to the internal X-ray afterglow emission, whose luminosity is assumed to track the magnetic dipole luminosity of the magnetars with a certain fraction. Following a comparison between the model and some selected observational samples, we suggest that some so-called canonical X-ray afterglows including the shallow decay, normal decay, and steeper-than-normal decay phases could be internally produced by the magnetars (possibly through some internal dissipations of the magnetar winds), while the (energized) external shocks are associated with another type of X-ray afterglows. If this is true, then from those internal X-ray afterglows we can further determine the magnetic field strengths and the initial spin periods of the corresponding magnetars.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE INTERNAL DYNAMICS OF THE STARLESS CORE L694-2

In order to understand the internal dynamics of starless cores, we take L694-2 as an example of starless cores and investigate its internal dynamics by comparing observed data of L694-2 to our two hydrodynamical simulations, which involve the gravitational collapse of marginally unstable Bonnor-Ebert and uniform cores in a quiescent region. From the comparisons, we find that the density structures of the models agree well with the observed density distribution of L694-2, but the velocity fields and HCN line profiles of the models differ from the observed ones. From the differences in the velocity fields and the HCN line profiles, we have reached the following conclusions on the internal dynamics of L694-2. First, L694-2 has different internal dynamics from the gravitational collapse of the marginally unstable Bonnor-Ebert core. Second, L694-2 has an infall speed faster than any other core that undergoes the gravitational collapse with a Bonnor-Ebert-like density structure in a quiescent region. Third, L694-2 has almost no motion at its surface. From further simulations, in which cores are perturbed by supersonic shocks and affected by an expanding inter-core medium, the differences in the HCN line profiles could be reduced considerably.

79 ASTRONOMY AND ASTROPHYSICS↗

THE INTERNAL ROTATION PROFILE OF THE B-TYPE STAR KIC 10526294 FROM FREQUENCY INVERSION OF ITS DIPOLE GRAVITY MODES

The internal angular momentum distribution of a star is the key to determining its evolution. Fortunately, stellar internal rotation can be probed through studies of rotationally split nonradial oscillation modes. In particular, the detection of nonradial gravity modes (g modes) in massive young stars has recently become feasible thanks to the Kepler space mission. Our goal is to derive the internal rotation profile of the Kepler B8V star KIC 10526294 through asteroseismology. We interpret the observed rotational splittings of its dipole g modes using four different approaches based on the best seismic models of the star and their rotational kernels. We show that these kernels can resolve differential rotation within the radiative envelope if a smooth rotational profile is assumed and if the observational errors are small. Based on Kepler data, we find that the rotation rate near the core-envelope boundary is well constrained to 163 ± 89 nHz. The seismic data are consistent with rigid rotation but a profile with counter-rotation within the envelope has a statistical advantage over constant rotation. Our study should be repeated for other massive stars with a variety of stellar parameters in order to determine the physical conditions that control the internal rotation profile of young massive stars, with the aim of improving the input physics of their models.

79 ASTRONOMY AND ASTROPHYSICS↗