Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Effect of exposure environment on surface decomposition of SiC-silver ion implantation diffusion couples

SiC is a promising material for nuclear applications and is a critical component in the construction of tristructural isotropic (TRISO) fuel. A primary issue with TRISO fuel operation is the observed release of 110m Ag from intact fuel particles. The release of Ag has prompted research efforts to directly measure the transport mechanism of Ag in bulk SiC. Recent research efforts have focused primarily on Ag ion implantation designs. The effect of the thermal exposure system on the ion implantation surface has been investigated. Results indicate the utilization of a mated sample geometry and the establishment of a static thermal exposure environment is critical to maintaining an intact surface for diffusion analysis. In conclusion, the nature of the implantation surface and its potential role in Ag diffusion analysis are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Observations of Ag diffusion in ion implanted SiC

The nature and magnitude of Ag diffusion in SiC has been a topic of interest in connection with the performance of tristructural isotropic (TRISO) coated particle fuel for high temperature gas-cooled nuclear reactors. Ion implantation diffusion couples have been revisited to continue developing a more complete understanding of Ag fission product diffusion in SiC. Ion implantation diffusion couples fabricated from single crystal 4H-SiC and polycrystalline 3C-SiC substrates and exposed to 1500–1625°C, were investigated in this study by transmission electron microscopy and secondary ion mass spectrometry (SIMS). The high dynamic range of SIMS allowed for multiple diffusion régimes to be investigated, including enhanced diffusion by implantation-induced defects and grain boundary (GB) diffusion in undamaged SiC. Lastly, estimated diffusion coefficients suggest GB diffusion in bulk SiC does not properly describe the release observed from TRISO fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of thermal oxidation on helium implanted pure iron

The impact of thermal oxidation on Helium (He) implanted pure iron (Fe) was investigated to experimentally evaluate how thermal oxidation influences the diffusion and distribution of He within the material. In case of the sample with the lowest dose (2 × 10 17 ions/cm 2 ), the thinnest oxide layer was observed compared to the non-implanted pure Fe. It is due to He nano bubbles implanted in the material, which hinder the diffusion of Fe ions necessary for forming the oxide layer. For the medium dose sample (5 × 10 17 ions/cm 2 ), the oxide layer was slightly thicker than that of the lowest dose, however it had more porous structure due to the numerous nano He bubbles. In addition, a large bubble region around 150–200 nm depth was generated. Here, the highest dose sample (1 × 10 18 ions/cm 2 ) was observed that the escape of He was accelerated by the large amount of nano He bubbles from within the metal, forming a porous Fe matrix on the top surface and an oxide layer that is very porous but thicker than those of lower doses.

He implantation↗

Implant breast reconstruction followed by radiotherapy: Can helical tomotherapy become a standard irradiation treatment?

To evaluate the benefits and limitations of helical tomotherapy (HT) for loco-regional irradiation of patients after a mastectomy and immediate implant-based reconstruction. Ten breast cancer patients with retropectoral implants were randomly selected for this comparative study. Planning target volumes (PTVs) 1 (the volume between the skin and the implant, plus margin) and 2 (supraclavicular, infraclavicular, and internal mammary nodes, plus margin) were 50 Gy in 25 fractions using a standard technique and HT. The extracted dosimetric data were compared using a 2-tailed Wilcoxon matched-pair signed-rank test. Doses for PTV1 and PTV2 were significantly higher with HT (V95 of 98.91 and 97.91%, respectively) compared with the standard technique (77.46 and 72.91%, respectively). Similarly, the indexes of homogeneity were significantly greater with HT (p = 0.002). HT reduced ipsilateral lung volume that received {>=}20 Gy (16.7 vs. 35%), and bilateral lungs (p = 0.01) and neighboring organs received doses that remained well below tolerance levels. The heart volume, which received 25 Gy, was negligible with both techniques. HT can achieve full target coverage while decreasing high doses to the heart and ipsilateral lung. However, the low doses to normal tissue volumes need to be reduced in future studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of Defects in N-type 4H-SiC After High-Energy N Ion Implantation by RBS-Channeling and Raman Spectroscopy

Implantation with 1 MeV N ions was performed at room temperature in n-type 4H-SiC(0001) to four implantation fluences (or doses in dpa (displacements per atom) at the damage peak) of 1.5×1013(0.0034), 7.8×1013(0.018), 1.5×1014(0.034), and 7.8×1014(0.18) ions/cm2, respectively. The evolution of disorder was studied using Rutherford backscattering spectrometry in channeling mode (RBS-C) and Raman spectroscopy. The disorder in the Si sub-lattice was found to be less than 10% for the dpa of 0.0034 and 0.0178 and increased to 40% and 60% for the dpa of 0.034 and 0.178 respectively. Raman Spectroscopy was performed using a green laser of wavelength 532 nm as excitation source. The normalized Raman Intensity, In shows disorder of 41%, 69%, 77% and 100% for the dpa of 0.0034, 0.017, 0.034 and 0.178 respectively. In this paper, the characterizations of the defects produced due to the Nitrogen implantation in 4H-SiC are presented and the results are discussed.

Environmental Molecular Sciences Laboratory↗

Taming the Pseudoelastic Response of Nitinol Using Ion Implantation

Implantation of Ni 50.5 Ti 49.5 wire with 30 MeV Ni 6+ ions at doses (< 0.1 DPA) typically smaller than employed in the literature is shown to systematically alter the pseudoelastic response, with extrema in Berkovich nanoindentation load (+50%), hysteresis (–60%), and recoverable displacement (–19%) occurring at ~ 3.6 μm below the implantation surface. These extraordinary values are attributed to ~ 10 to 20 nm amorphous clusters that constrain the stress-induced B2-B19' phase transformation. This is substantiated by phase field simulations of crystalline-amorphous composites and molecular dynamics simulations of crystalline-vacancy cluster composites showing the spatial refinement of martensite caused by nm-scale defects. Finally, the results suggest that ion implantation may potentially expand the processing and performance space for NiTi, by creating amorphous defects at smaller length scales than dislocation substructures produced by conventional deformation processing.

36 MATERIALS SCIENCE↗

Stress engineering for crack and dendrite prevention in solid electrolytes via ion implantation

Solid-state batteries represent a promising technology that offers safer and more densely packed energy storage. A primary cause of failure in solid-state cells is the penetration of metal dendrites through the solid electrolyte. Here, we report that fluorine-ion implantation can enhance the mechanical resistance of solid electrolyte Li 6.5 La 3 Zr 1.5 Ta 0.5 O 12 to dendrite propagation by inducing residual compressive stress in the subsurface of the electrolyte. Ion implantation modifies subsurface residual stress and also alters the electrolyte’s surface, resulting in multifunctional enhancement. The combined chemical and mechanical effects of ion implantation enable reversible lithium metal stripping and plating at elevated current densities while enhancing air stability and mitigating the formation of a harmful carbonate layer at the surface. This study provides new insights into a scalable dendrite-suppression strategy for designing solid-state batteries suitable for cycling at room temperature and low stack pressures.

25 ENERGY STORAGE↗

Tuning Chiral Anomaly Signature in a Dirac Semimetal via Fast-Ion Implantation

Cd 3 As 2 is a Dirac semimetal that hosts a chiral anomaly, functioning as a platform to realize energy applications. We use fast-ion implantation to enhance the negative longitudinal magnetoresistance (NLMR)─signature of a chiral anomaly─in Nb-doped Cd 3 As 2 thin films. High-energy ion implantation is used to investigate semiconductors and nuclear materials but is rarely employed to study topological materials. We use electrical transport and transmission electron microscopy to characterize the NLMR and crystallinity of Nb-doped Cd 3 As 2 . We find surface-doped thin films display a maximum NLMR around B = 7 T and bulk-doped thin films display a maximum over B = 9 T─all while maintaining crystallinity. This is more than a 100% relative enhancement of the maximum NLMR compared to pristine Cd 3 As 2 . As a result, our work demonstrates the potential of high-energy ion implantation as a practical route to explore chiralitronic properties in topological semimetals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low Energy Implantation into Transition-Metal Dichalcogenide Monolayers to Form Janus Structures

Atomically-thin two-dimensional (2D) materials face significant energy barriers for synthesis and processing into functional metastable phases such as Janus structures. Here, in this study, the controllable implantation of hyperthermal species from pulsed laser deposition (PLD) plasmas is introduced as a top-down method to compositionally engineer 2D monolayers. The kinetic energies of Se clusters impinging on suspended monolayer WS 2 crystals were controlled in the <10 eV/atom range with in situ plasma diagnostics to determine the thresholds for selective top layer replacement of sulfur by selenium for the formation of high quality WSSe Janus monolayers at low (300 °C) temperatures, and bottom layer replacement for complete conversion to WSe 2 . Atomic-resolution electron microscopy and spectroscopy in tilted geometry confirm the WSSe Janus monolayer. Molecular dynamics simulations reveal that Se clusters implant to form disordered metastable alloy regions, which then recrystallize to form highly ordered structures, opening the door for low-energy implantation by PLD as a novel method to explore the synthesis of 2D Janus layers and alloys of variable composition.

2D materials↗

Dynamics of Carrier Plasma and Thermal Waves in Ion Implanted Si with Varying Pump and Probe Wavelengths

Dynamics of the carrier plasma- and thermal-waves in ion implanted Si is studied using the Modulated Optical Reflectance (MOR) technique with varying pump and probe beam wavelengths. It is shown that selection of the pump and probe beam wavelengths allows control of the MOR signal behavior on Si samples implanted with a wide range of implantation energies and doses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative Evaluation of Ion-implanted Arsenic in Silicon by Instrumental Neutron Activation Analysis

Certified reference materials (CRMs) of shallow arsenic implants in silicon are now under development at the National Metrology Institute of Japan (NMIJ). The amount of ion-implanted arsenic atoms is quantified by Instrumental Neutron Activation Analysis (INAA) using research reactor JRR-3 in Japan Atomic Energy Agency (JAEA). It is found that this method can evaluate arsenic amounts of 10{sup 15} atoms/cm{sup 2} with small uncertainties, and is adaptable to shallower dopants. The estimated uncertainties can satisfy the industrial demands for reference materials to calibrate the implanted dose of arsenic at shallow junctions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next Generation Angle Control for Medium Current and High Energy Implanters

Angle control continues to increase in importance with device scaling. For instance, threshold voltage and on-state current in advanced logic devices depend critically on the angle accuracy of medium current halo implants. TCAD simulation results, showing that on-state current changes of greater than 1% per degree of implant angle are possible, are presented. We report here on improvements to angle performance and control in both the horizontal and vertical directions. Beam data covering the full operating space of the VIISta 900XP is presented, demonstrating total angle control of better than {+-}0.2 deg. The data set is chosen to emphasize performance of typical halo implants. Single wafer high energy angle control data is also presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface Analytics in Support of the Development of Static AutoClean - an In-Situ Cleaning Process for Ion Implanters

Static AutoClean is a new in-situ cleaning strategy in development at ATMI registered that enables increased process efficiency and safety in the ion implantation process. Like the Dynamic in-situ AutoClean technology previously introduced and released by ATMI, Static AutoClean utilizes XeF{sub 2} chemistry for in-situ cleaning of hazardous contaminants and deposits. Static AutoClean, however, is targeted towards cleaning areas of the beam-line (like electrode insulators or source bushings) where cleaning efforts using Dynamic AutoClean may not be sufficient. An explanation of this cleaning strategy and results showing its effectiveness will be presented in a separate paper at this conference (S. Yedave et al.). This paper presents the surface analytical data and methods used to understand and evaluate the effectiveness of Static AutoClean in removing contaminants from surfaces within the source vacuum chamber. Energy Dispersive Spectroscopy (EDS) was used to track the magnitude and spatial distribution of contaminants present on the surfaces within various regions in the source chamber space of an implanter following ion source operation with a commonly used dopant gas. After in-situ cleaning, these same components and surfaces were re-evaluated by EDS to quantitatively determine the reduction in surface contaminants present within the chamber. Learnings regarding the distribution of implant process contamination within the source chamber as well as Static AutoClean's effectiveness in removing it will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

B{sub 18}H{sub 22} Implantation for the Source-Drain Extension in 45 nm-node PMOSFETs and Beyond

We investigated the application properties of cluster implantation for MSA processing. We successfully replaced BF{sub 2} with B{sub 18}H{sub 22} to SDE implantation in pMOSFETs with the activation processing of MSA and spike-RTA. In the activation processing with only MSA, we found from blank wafer that B{sub 18}H{sub 22} implant is more advantageous from the viewpoint of R{sub s}, X{sub j} and leakage current, compared to B, BF{sub 2} and B with Ge-PAI00.

36 MATERIALS SCIENCE↗

Fabrication of Ultra-Shallow Junctions on 300 mm Wafers Using the Plasma Immersion Implanter PULSION registered Followed by Spike Annealing Using LEVITOR Furnace

Thanks to the European Project SEA-NET, an industrial version of the IBS Plasma Ion Implantation tool has been installed in LETI for the fabrication of Ultra-Shallow Junction for 45 and 32 nm CMOS on 200 and 300 mm wafers. In this study, we present first doping results on 300 mm wafers using BF{sub 3} plasma. Annealing after PULSION implantation is performed by the ASM furnace LEVITOR. This tool, which works on conduction heating is emissivity independent for temperature control and allows reaching high ramp up and ramp down speeds (up to 900 deg. C/s). Main characteristics of as implanted wafers are presented (metal contamination 2E10/cm{sup 2}, SIMS depth profiles down to 5 nm). Then the effect of convection gas in the annealing process on sheet resistance, junction depth and uniformity is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Boron Profile Sharpening in Ultra-Shallow p{sup +}-n Junction Produced by Plasma Immersion Ion Implantation from BF{sub 3} Plasma

We have investigated plasma immersion ion implantation (PI{sup 3}) of boron with energies of 500 eV (doses up to 2x10{sup 15} cm{sup -2}) from BF{sub 3} plasma with He pre-amorphizing implantation (PAI)(energy 3 keV, dose 5x10{sup 16} cm{sup -2}). Implanted samples were subjected to RTA (T = 900 to 1050 deg. C, t = 2 to 24 sec and spike anneal). SIMS analysis of boron profiles revealed its anomalous behavior. For short RTA times the profile tail (below 5x10{sup 19} cm{sup -3}) moves toward the surface and then, as in the usual diffusion, toward the bulk at longer annealing times.

36 MATERIALS SCIENCE↗

The Effect of the Dose and Energy of a Pre-Silicide Implant on Nickel Silicide Formation

Pre-silicide implants have been used to increase the thermal stability of nickel silicide (NiSi) and to improve device performance. This study evaluates the effect of the dose, energy and species of a pre-silicide ion implant on NiSi phase formation. The resulting silicide was evaluated using sheet resistance, scanning electron Microscope (SEM) cross-sections, and Rutherford Backscattering Spectroscopy (RBS) analysis. It was found that a high dose argon implant will completely inhibit the silicide formation.

36 MATERIALS SCIENCE↗

Evolution of implantation induced damage under further ion irradiation: Influence of damage type

The evolution of damage in silicon formed by H, He, and Si ion implantations under further ion irradiation, where the ion energy is primarily deposited into electronic excitation, has been studied at 77 K and at room temperature. For damage introduced by He or Si ion implantation, which primarily consists of vacancy and interstitial type defects, a subsequent irradiation with 110 keV protons at room temperature results in a decrease in ion channeling direct backscattering yield, while no change is observed when the irradiation is carried out at 77 K. In contrast, H ion implantation damage, which mainly consists of H-stabilized defects, is observed to increase under the same following on 110 keV proton irradiation at both room temperature and 77 K. The differences in damage evolutions can be used to construct a coherent picture of how energy deposited into electronic processes affects defect dissociation, migration, and reconstruction and the final damage morphology.

36 MATERIALS SCIENCE↗