Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Demonstration of x-ray fluorescence imaging of a high-energy-density plasma

Experiments at the Trident Laser Facility have successfully demonstrated the use of x-ray fluorescence imaging (XRFI) to diagnose shocked carbonized resorcinol formaldehyde (CRF) foams doped with Ti. One laser beam created a shock wave in the doped foam. A second laser beam produced a flux of vanadium He-α x-rays, which in turn induced Ti K-shell fluorescence within the foam. Spectrally resolved 1D imaging of the x-ray fluorescence provided shock location and compression measurements. Additionally, experiments using a collimator demonstrated that one can probe specific regions within a target. These results show that XRFI is a capable alternative to path-integrated measurements for diagnosing hydrodynamic experiments at high energy density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental evaluation of electrical conductivity imaging of anisotropic brain tissues using a combination of diffusion tensor imaging and magnetic resonance electrical impedance tomography

Anisotropy of biological tissues is a low-frequency phenomenon that is associated with the function and structure of cell membranes. Imaging of anisotropic conductivity has potential for the analysis of interactions between electromagnetic fields and biological systems, such as the prediction of current pathways in electrical stimulation therapy. To improve application to the clinical environment, precise approaches are required to understand the exact responses inside the human body subjected to the stimulated currents. In this study, we experimentally evaluate the anisotropic conductivity tensor distribution of canine brain tissues, using a recently developed diffusion tensor-magnetic resonance electrical impedance tomography method. At low frequency, electrical conductivity of the biological tissues can be expressed as a product of the mobility and concentration of ions in the extracellular space. From diffusion tensor images of the brain, we can obtain directional information on diffusive movements of water molecules, which correspond to the mobility of ions. The position dependent scale factor, which provides information on ion concentration, was successfully calculated from the magnetic flux density, to obtain the equivalent conductivity tensor. By combining the information from both techniques, we can finally reconstruct the anisotropic conductivity tensor images of brain tissues. The reconstructed conductivity images better demonstrate the enhanced signal intensity in strongly anisotropic brain regions, compared with those resulting from previous methods using a global scale factor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On evaluating x-ray imaging crystals with synchrotron radiation

Bent crystals are central to 1-D resolved x-ray spectroscopy and two-dimensional x-ray imaging of plasmas. Nominally identical crystals may differ in their performance with x-rays even though their visible-light images are close to identical. The detailed information needed to understand those differences, viz., the crystal’s local diffraction properties over the area that contributes to the image, is averaged out in the imaging tests that ideally precede the actual crystal’s use. Here the local diffraction of spherically bent crystals made from quartz is examined in the x-ray topography setup at the x-ray optics testing beamline 1-BM at the Advanced Photon Source, with radiation obtained from a flat quartz conditioning crystal made for the purpose.

Pereira, N. R.↗

Optimizing automatic morphological classification of galaxies with machine learning and deep learning using Dark Energy Survey imaging

There are several supervised machine learning methods used for the application of automated morphological classification of galaxies; however, there has not yet been a clear comparison of these different methods using imaging data, or an investigation for maximizing their effectiveness. We carry out a comparison between several common machine learning methods for galaxy classification [Convolutional Neural Network (CNN), K-nearest neighbour, logistic regression, Support Vector Machine, Random Forest, and Neural Networks] by using Dark Energy Survey (DES) data combined with visual classifications from the Galaxy Zoo 1 project (GZ1). Our goal is to determine the optimal machine learning methods when using imaging data for galaxy classification. We show that CNN is the most successful method of these ten methods in our study. Using a sample of ~2800 galaxies with visual classification from GZ1, we reach an accuracy of ~0.99 for the morphological classification of ellipticals and spirals. The further investigation of the galaxies that have a different ML and visual classification but with high predicted probabilities in our CNN usually reveals the incorrect classification provided by GZ1. We further find the galaxies having a low probability of being either spirals or ellipticals are visually lenticulars (S0), demonstrating that supervised learning is able to rediscover that this class of galaxy is distinct from both ellipticals and spirals. We confirm that ~2.5 percent galaxies are misclassified by GZ1 in our study. After correcting these galaxies’ labels, we improve our CNN performance to an average accuracy of over 0.99 (accuracy of 0.994 is our best result).

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

Advanced Photovoltaic Module Characterization: Using Image Transformers for Current–Voltage Curve Prediction From Electroluminescence Images

Individual photovoltaic (PV) module health monitoring can be a daunting task for operation and maintenance of solar farms. Modules can be inspected through luminescence, thermal imaging, and current–voltage (I–V) curve analyzes for identification of damage and power loss. I–V curves provide easily interpretable data to determine module health as they directly provide electrical performance metrics. However, in order to obtain these curves, modules must be disconnected from the array and either removed to a solar simulator or characterized in situ with corrections for module temperature, the incident solar spectrum, and intensity. Luminescence or thermal images of a module are relatively easy to acquire in situ. Electroluminescence (EL) images highlight physical defects in the modules but do not provide easily interpretable features to correlate with electrical performance. This work presents a SWin transformer network to predict I–V curves for PV modules from their corresponding EL images. The predicted I–V curves allow the accurate prediction of the maximum power point (MPP), short-circuit current I sc , and open-circuit voltage V oc with a mean error less of than 1%. Comparing single diode model (SDM) parameters extracted from the predicted curves to those extracted from the true curves, the series resistance R s demonstrates a mean error of 5.19%, and the photocurrent I a mean error of 0.197%. The shunt resistance R sh and dark current Io parameters are predicted with larger errors because of their sensitivity to small changes in the I–V curve.

Byford, Brandon K. [New Mexico State Univ., Las Cr↗

Image reconstruction of shielded mixed-oxide fuel using a dual-particle imaging system

The dual-particle imaging system being developed at the University of Michigan was used at the Joint Research Centre in Ispra, Italy for measurements on samples of special nuclear material. A 1,150-g mixed-oxide (MOX) fuel sample was measured with various shielding configurations to determine how the presence of lead and/or polyethylene shielding degrades the system's ability to localize a source by simultaneous neutron and photon imaging. Three two-hour measurements were taken with the source shielded by an: a) 8-mm lead sheath and 5.1-cm lead bricks, b) 8-mm lead sheath and 6.5-cm polyethylene bricks, and c) 8-mm lead sheath, 5.1-cm lead bricks, and 6.5-cm polyethylene bricks. The 8-mm lead sheath was used in all cases to reduce the measured photon count rate. A “bare” measurement was also made by using only the 8-mm lead sheath, but the unexpected presence of additional sources has rendered the measurement unsuitable for comparison. Here, the resulting images show that the dual-particle imaging system is able to accurately localize the MOX canister in the presence of intervening material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mesoscale imaging with cryo-light and X-rays: Larger than molecular machines, smaller than a cell: Mesoscale imaging with cryo-light and X-rays

In the context of cell biology, the term mesoscale describes length scales ranging from that of an individual cell, down to the size of the molecular machines. In this spatial regime, small building blocks self-organise to form large, functional structures. A comprehensive set of rules governing mesoscale self-organisation has not been established, making the prediction of many cell behaviours difficult, if not impossible. Our knowledge of mesoscale biology comes from experimental data, in particular, imaging. Here, we explore the application of soft X-ray tomography (SXT) to imaging the mesoscale, and describe the structural insights this technology can generate. We also discuss how SXT imaging is complemented by the addition of correlative fluorescence data measured from the same cell. This combination of two discrete imaging modalities produces a 3D view of the cell that blends high-resolution structural information with precise molecular localisation data.

59 BASIC BIOLOGICAL SCIENCES↗

Developing high-frequency ultrasound tomography for testicular tumor imaging in rats: An in vitro study

Purpose: This paper describes a feasibility study for developing a 35-MHz high-frequency ultrasound computed-tomography (HFUCT) system for imaging rat testicles. Methods: The performances of two kinds of HFUCT-attenuation and sound-speed UCT-based on transmission and pulse-echo modes were investigated in this study. Experiments were carried out using phantoms and actual rat testiclesin vitro. HFUCT images were reconstructed using a filtered backprojection algorithm. Results: The phantom experimental results indicated that all types of HFUCT can determine the dimensions of a plastic cylinder with a diameter of 500μm. Compared to sound-speed HFUCT, attenuation HFUCT exhibited a better performance in recognizing a tiny sclerosed region in a gelatin phantom. Therefore, the in vitro testicular experiments were performed using attenuation HFUCT based on transmission and pulse-echo modes. The experimentally measured attenuation coefficient and sound speed for healthy rat testicles were 2.92 ± 0.25 dB/mm and 1537 ± 25 m/s, respectively. Conclusions: A homogeneous texture was evident for healthy testicles using both modes. An artificial sclerosed tumor could also be clearly observed using two- and three-dimensional attenuation HFUCT in both modes. However, an object artifact was apparent in pulse-echo mode because of ultrasound beam refraction. All of the obtained experimental results indicate the potential of using HFUCT as a novel tool for monitoring the preclinical responses of testicular tumors in small animals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-E-18A-01: Imaging: Best Practices In Pediatric Imaging

This imaging educational program will focus on solutions to common pediatric imaging challenges. The speakers will present collective knowledge on best practices in pediatric imaging from their experience at dedicated children's hospitals. Areas of focus will include general radiography, the use of manual and automatic dose management in computed tomography, and enterprise-wide radiation dose management in the pediatric practice. The educational program will begin with a discussion of the complexities of exposure factor control in pediatric projection radiography. Following this introduction will be two lectures addressing the challenges of computed tomography (CT) protocol optimization in the pediatric population. The first will address manual CT protocol design in order to establish a managed radiation dose for any pediatric exam on any CT scanner. The second CT lecture will focus on the intricacies of automatic dose modulation in pediatric imaging with an emphasis on getting reliable results in algorithmbased technique selection. The fourth and final lecture will address the key elements needed to developing a comprehensive radiation dose management program for the pediatric environment with particular attention paid to new regulations and obligations of practicing medical physicists. Learning Objectives: To understand how general radiographic techniques can be optimized using exposure indices in order to improve pediatric radiography. To learn how to establish diagnostic dose reference levels for pediatric patients as a function of the type of examination, patient size, and individual design characteristics of the CT scanner. To learn how to predict the patient's radiation dose prior to the exam and manually adjust technique factors if necessary to match the patient's dose to the department's established dose reference levels. To learn how to utilize manufacturer-provided automatic dose modulation technology to consistently achieve patient doses within the department's established size-based diagnostic reference range. To understand the key components of an enterprise-wide pediatric dose management program that integrates the expanding responsibilities of medial physicists in the new era of dose monitoring.

60 APPLIED LIFE SCIENCES↗

Beyond crystallography: Diffractive imaging using coherent x-ray light sources

X-ray crystallography has been central to the development of many fields of science over the past century. It has now matured to a point that as long as good-quality crystals are available, their atomic structure can be routinely determined in three dimensions. However, many samples in physics, chemistry, materials science, nanoscience, geology, and biology are noncrystalline, and thus their three-dimensional structures are not accessible by traditional x-ray crystallography. Overcoming this hurdle has required the development of new coherent imaging methods to harness new coherent x-ray light sources. Here we review the revolutionary advances that are transforming x-ray sources and imaging in the 21st century.

Miao, Jianwei↗

Small-angle X-ray scattering characteristics of mouse brain: Planar imaging measurements and tomographic imaging simulations

Small-angle x-ray scattering (SAXS) imaging can differentiate tissue types based on their nanoscale molecular structure. However, characterization of the coherent scattering cross-section profile of relevant tissues is needed to optimally design SAXS imaging techniques for a variety of biomedical applications. Reported measured nervous tissue x-ray scattering cross sections under a synchrotron source have had limited agreement. We report a set of x-ray cross-section measurements obtained from planar SAXS imaging of 1 mm thick mouse brain (APP/PS1 wild-type) coronal slices using an 8 keV laboratory x-ray source. Two characteristic peaks were found at 0.96 and 1.60 nm -1 attributed to myelin. The peak intensities varied by location in the slice. We found that regions of gray matter, white matter, and corpus callosum could be segmented by their increasing intensities of myelin peaks respectively. Measured small-angle x-ray scattering cross sections were then used to define brain tissue scattering properties in a GPU-accelerated Monte Carlo simulation of SAXS computed tomography (CT) using a higher monochromatic x-ray energy (20 keV) to study design trade-offs for noninvasive in vivo SAXS imaging on a small-animal head including radiation dose, signal-to-noise ratio (SNR), and the effect of skull presence on the previous two metrics. Simulation results show the estimated total dose to the mouse head for a single SAXS-CT slice was 149.4 mGy. The pixel SNR was approximately 30.8 for white matter material whether or not a skull was present. In this early-stage proof-of-principle work, we have demonstrated our brain cross-section data and simulation tools can be used to assess optimal instrument parameters for dedicated small-animal SAXS-CT prototypes.

59 BASIC BIOLOGICAL SCIENCES↗

Synthetic Aperture Radar Image Geolocation Using Fiducial Images

Synthetic Aperture Radar (SAR) creates imagery of the earth’s surface from airborne or spaceborne radar platforms. However, the nature of any radar is to geolocate its echo data, i.e., SAR images, relative to its own measured radar location. Acceptable accuracy and precision of such geolocation can be quite difficult to achieve, and is limited by any number of parameters. However, databases of geolocated earth imagery do exist, often using other imaging modalities, with Google Earth being one such example. These can often be much more accurate than what might be achievable by the radar itself. Consequently, SAR images may be aligned to some higher accuracy database, thereby improving the geolocation of features in the SAR image. Examples offer anecdotal evidence of the viability of such an approach.

47 OTHER INSTRUMENTATION↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus ‘super-resolution’). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

47 OTHER INSTRUMENTATION↗

Gemini Planet Imager Spectroscopy of the Dusty Substellar Companion HD 206893 B

We present new near-infrared Gemini Planet Imager (GPI) spectroscopy of HD 206893 B, a substellar companion orbiting within the debris disk of its F5V star. The J, H, K1, and K2 spectra from GPI demonstrate the extraordinarily red colors of the object, confirming it as the reddest substellar object observed to date. The significant flux increase throughout the infrared presents a challenging atmosphere to model with existing grids. Best-fit values vary from 1200 to 1800 K for effective temperature and from 3.0 to 5.0 for log(g), depending on which individual wavelength band is fit and which model suite is applied. The extreme redness of the companion can be partially reconciled by invoking a high-altitude layer of submicron dust particles, similar to dereddening approaches applied to the peculiar red field L dwarf population. However, reconciling the HD 206893 B spectra with even those of the reddest low-gravity L dwarf spectra still requires the contribution of additional atmospheric dust, potentially due to the debris disk environment in which the companion resides. Orbit fitting from 4 yr of astrometric monitoring is consistent with a ∼30 yr period, an orbital inclination of 147°, and a semimajor axis of 10 au, well within the estimated disk inner radius of ∼50 au. As one of a very few substellar companions imaged interior to a circumstellar disk, the properties of this system offer important dynamical constraints on companion–disk interaction and provide a benchmark for substellar and planetary atmospheric study.

47 OTHER INSTRUMENTATION↗

Change-point Detection and Image Segmentation for Time Series of Astrophysical Images

Many astrophysical phenomena are time-varying, in the sense that their intensity, energy spectrum, and/or the spatial distribution of the emission suddenly change. This paper develops a method for modeling a time series of images. Under the assumption that the arrival times of the photons follow a Poisson process, the data are binned into 4D grids of voxels (time, energy band, and x-y coordinates), and viewed as a time series of non-homogeneous Poisson images. The method assumes that at each time point, the corresponding multiband image stack is an unknown 3D piecewise constant function including Poisson noise. It also assumes that all image stacks between any two adjacent change points (in time domain) share the same unknown piecewise constant function. The proposed method is designed to estimate the number and the locations of all of the change points (in time domain), as well as all of the unknown piecewise constant functions between any pairs of the change points. The method applies the minimum description length principle to perform this task. A practical algorithm is also developed to solve the corresponding complicated optimization problem. Simulation experiments and applications to real data sets show that the proposed method enjoys very promising empirical properties. Applications to two real data sets, the XMM observation of a flaring star and an emerging solar coronal loop, illustrate the usage of the proposed method and the scientific insight gained from it.

79 ASTRONOMY AND ASTROPHYSICS↗

Hadamard transform imager and imaging spectrometer

An imager and a spectrometric imager, which achieve multiplexing by the use of binary optical encoding masks, have been built and tested. The masks are based on orthogonal, pseudorandom digital codes derived from Hadamard matrices. The spatial (and/or spectral) data are therefore obtained in the form of a Hadamard transform of the spatial (and/or spectral) scene. Computer algorithms are used to decode the data and reconstruct images of the original scene. The hardware, algorithms processing and display facility are described. A number of spatial and spatial/spectral images, obtained in the laboratory, are presented.

Swift, R. D.↗