Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Human Errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Template Engine Applied to Rapid Modeling

Modeling complex problems can require a significant effort, be subject to human error, and contain repeated patterns of input. SCALE 6.2 and the Used Nuclear Fuel-Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS) have attempted to mitigate these problems with the use of a template engine and template syntax. The template syntax allows redundant input to be consolidated into its simplest pattern and parameterized on the parts that change, reducing effort and likelihood of errors and encapsulating user experience into a reusable model component. This paper presents a summary of rapid modeling benefits and techniques that are facilitated when using templates. Specifically, this paper will discuss how these are applied in conducting as-loaded spent nuclear fuel canister criticality calculations using UNF-ST&DARDS and model perturbation and sampling using.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Method to Extract Soiling Loss Data from Soiling Stations with Imperfect Cleaning Schedules: Preprint

Typical PV soiling stations determine the natural soiling losses by comparing the output of a naturally soiled PV cell to that of a PV cell maintained in the clean state. Inadequate cleaning frequency or human error provides opportunity for the cleaned cell to soil, directly resulting in error in the reported soiling ratio. This work investigates an algorithm to automatically detect and correct the data stream for errors associated with soiling of the clean cell. The methodology is tested on several soiling stations with irregular cleaning schedules as well as a soiling station where both ideal and imperfect cleaning schedules are in place. The initial results show that the algorithm can reduce error associated with imperfect cleaning but also confirms the benefits of maintaining an optimal cleaning schedule.

14 SOLAR ENERGY↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy’s National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real- time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI’s Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: 1. Run in real-time on the edge (≥ 12 Hz) 2. Classification: Achieve less than 5% false positive detection 3. Classification: Achieve ≥ 95% methane plume detection rate 4. Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

A Python Library for Radiance Matrix-based Simulation Control and EnergyPlus Integration

Radiance matrix-based methods enable efficient parametric simulations, allowing users to vary sky conditions, fenestration systems, and other model parameters at a minimal cost to computation. However, the steep learning curve and complex workflow hinder the widespread adoption of matrix-based methods. The frads Python library with a series of command-line tools was developed to automate the entire matrix-based simulation process, lowering entry barriers and reducing human error. Co-simulation between EnergyPlus and Radiance was also enabled using the Python library from EnergyPlus. Key Innovations • Command-line based automation of Radiance matrix-based simulation methods • Python library facilitates broader adoption of Radiance matrix-based simulation methods • Radiance EnergyPlus run-time integration enabling the modeling of advanced control systems Practical Implications The frads library, with associated command-line tools, provides practitioners with the capability to easily adopt and use Radiance matrix-based simulation methods for various daylighting, solar control, and energy-related evaluations. Frads' current form is designed for 1) users familiar with a command-line interface and 2) software developers to integrate the matrix-based methods into existing software packages.

Wang, Taoning↗

Energy Management Information Systems Cybersecurity Best Practices

Energy management information systems (EMIS) are a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance. Critical systems are often integrated with or operate on the same networks as EMIS scope systems, necessitating stable, continuous, and secure communication. When connecting EMIS to building automation and utility control systems, there are also many physical assets that could cause harm to the building and its occupants if a malicious act or human error were introduced. It is imperative to ensure all EMIS scope systems are connected securely to the EMIS and do not open vulnerable pathways to other facility networks and operations. The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of EMIS at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of required EMIS cybersecurity standards for compliance and authority to operate along with additional recommendations.

cybersecurity↗

Energy Management Information Systems Cybersecurity Best Practices

Energy management information systems (EMIS) are a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance. Critical systems are often integrated with or operate on the same networks as EMIS scope systems, necessitating stable, continuous, and secure communication. When connecting EMIS to building automation and utility control systems, there are also many physical assets that could cause harm to the building and its occupants if a malicious act or human error were introduced. It is imperative to ensure all EMIS scope systems are connected securely to the EMIS and do not open vulnerable pathways to other facility networks and operations. The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of EMIS at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of required EMIS cybersecurity standards for compliance and authority to operate along with additional recommendations.

Cybersecurity↗

BioSecure Digital Twin: Manufacturing Innovation and Cybersecurity Resilience

U.S. national security, prosperity, economy, and well-being require secure, flexible, and resilient Biopharmaceutical Manufacturing. The COVID-19 pandemic reaffirmed that the biomedical production value-chain is vulnerable to disruption and has been under attack from sophisticated nation-state adversaries. Current cyber defenses are inadequate, and the integrity of critical production systems and processes are inherently vulnerable to cyber-attacks, human error, and supply chain disruptions. The following chapter explores how a BioSecure Digital Twin will improve U.S. manufacturing resilience and preparedness to respond to these hazards by significantly improving monitoring, integrity, security, and agility of our manufacturing infrastructure and systems. The BioSecure Digital Twin combines a scalable manufacturing framework with a robust platform for monitoring and control to increase U.S. biopharma manufacturing resilience. Then, the chapter discusses some of the inherent vulnerabilities and challenges at the nexus of health and advanced manufacturing. Next, the chapter highlights that as the Pandemic evolves, we need agility and resilience to overcome significant obstacles. This section highlights an innovative application of Cyber Informed Engineering to developing and deploying a BioSecure Digital Twin to improve the resilience and security of the biopharma industrial supply chain and production processes. Finally, the chapter concludes with a process framework to complement the Digital Twin platform, called the Biopharma (Observe, Orient, Decide, Act) OODA Loop Framework (BOLF), a four-step approach to decision-making outputs from the Digital Twin. The BOLF will help end users leverage twin technology by distilling the available information, focusing the data on context, and rapidly making the best decision while remaining cognizant of changes that can be made as more data becomes available.

99 GENERAL AND MISCELLANEOUS↗

Expediting Groundwater Sampling at Hanford and Making It Safer - 13158

The CH2M HILL Plateau Remediation Company (CHPRC) manages the groundwater monitoring programs at the Department of Energy's 586-square-mile Hanford site in southeastern Washington state. These programs are regulated by the Resource Conservation and Recovery Act (RCRA), the Comprehensive Environmental Response Compensation and Liability Act (CERCLA), and the Atomic Energy Act (AEA). The purpose of monitoring is to track existing groundwater contamination from past practices, as well as other potential contamination that might originate from RCRA treatment, storage, and disposal (TSD) facilities. An integral part of the groundwater-monitoring program involves taking samples of the groundwater and measuring the water levels in wells scattered across the site. Each year, more than 1,500 wells are accessed for a variety of reasons. Historically, the monitoring activities have been very 'people intensive'. Field personnel or 'samplers' have been issued pre-printed forms showing information about the well(s) for a particular sampling evolution. This information is taken from two official electronic databases: the Hanford Well Information System (HWIS) and the Hanford Environmental Information System (HEIS). The samplers traditionally used these hardcopy forms to document the groundwater samples and well water-levels. After recording the entries in the field, the samplers turned the forms in at the end of the day and other personnel posted the collected information. In Automating Groundwater Sampling at Hanford (HNF-38542-FP Revision 0, Presented at Waste Management 2009 Conference, March 1 - March 5, 2009, Phoenix, AZ), we described the methods, tools, and techniques that would be used in automating the activities associated with measuring water levels. The Field Logging and Electronic Data Gathering (FLEDG) application/database that automates collecting the water-level measurement data has now been implemented at Hanford. In addition to eliminating the need to print out documents, the system saves three-to-four man days each month for the field personnel taking the measurements and the scientists and administrators managing the data and the documentation. After the information has received technical review, FLEDG automatically updates the database for water-level measurements and loads the document management system with the completed sampling report. Due to safety considerations, access to wells is conditional. A spreadsheet with appropriate data not only lists the wells that are cleared for work, but also the safety personnel who must be present before work can start. This spreadsheet is used in planning daily activities. Daily plans are structured to ensure that the wells to be sampled are cleared for work and the appropriate safety personnel have been assigned and are present before the work starts. Historically, the spreadsheets have been prepared manually, and as a result, are potentially subject to human error. However, a companion database application has been developed to work with FLEDG - making the entire sampling process more efficient and safer for personnel. The Well Access List - Electronic, WAL-E, is a database that contains much the same information that was previously manually loaded into the spread sheet. In addition, WAL-E contains a managed work-flow application that shows the access requirements and allows for appropriate reviews of the compiled well. Various CHPRC organizations, including Industrial Hygiene, RADCON, and Well Maintenance and Sample Administration are able to enter and review the wells added or deleted from the WAL-E database. The FLEDG system then accesses this database information to identify appropriate support personnel and provide safety requirements to field personnel. In addition, WAL-E offers the assurance that wells have appropriate locks and are correctly labeled and electrically grounded as required, before well activities begin. This feature is an extremely important aspect of the FLEDG/WAL-E system because it adds another safety check to the work evolution and reduces the potential for unsafe conditions to exist that would lead to a stop-work situation. This paper will further describe the technical aspects of both electronic programs/databases and their successful application at Hanford. (authors)

54 ENVIRONMENTAL SCIENCES↗

Region Three Aerial Measurement System Flight Planning Tool - 12006

The Region 3 Aerial Measurement System Flight Planning Tool is used by the National Nuclear Security Agency (NNSA), United States Department of Energy, Radiological Assistance Program, Region 3, to respond to emergency radiological situations. The tool automates the flight planning package process while decreasing Aerial Measuring System response times and decreases the potential for human error. Deployment of the Region Three Aerial Measurement System Flight Planning Tool has resulted in an immediate improvement to the flight planning process in that time required for mission planning has been reduced from 1.5 hours to 15 minutes. Anecdotally, the RAP team reports that the rate of usable data acquired during surveys has improved from 40-60 percent to over 90 percent since they began using the tool. Though the primary product of the flight planning tool is a pdf format document for use by the aircraft flight crew, the RAP team has begun carrying their laptop computer on the aircraft during missions. By connecting a Global Positioning System (GPS) device to the laptop and using ESRI ArcMap's GPS tool bar to overlay the aircraft position directly on the flight plan in real time, the RAP team can evaluate and correct the aircraft position as the mission is executed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Revised Arrangements for the Management of Solid and Non-Aqueous Radioactive Waste - 12452

In 2010, Atomic Weapons Establishment (AWE) identified a requirement to implement revised management arrangements for the generation, storage and disposal of radioactive waste. A thorough review of the current arrangements/processes was undertaken which included both legal compliance requirements and the identification of business improvement opportunities. On completion of this review a suitable project team was established and in 2011 an integrated Radioactive Waste Management process was implemented throughout the business. Initial results have shown measurable improvements within Radioactive Waste management compliance, operator understanding and increased business efficiency. Through the development and implementation of the revised working arrangements AWE has been able to continue to demonstrate both legal compliance to its regulators along with business efficiency and effectiveness improvements. Simple to follow process maps have improved employees understanding of Radioactive Waste management requirements, provided them with easily accessible information and ensured the business operates in a single coherent manner. The implementation of a modern electronic data management system has ensured all waste related information is easily retrievable and appropriately maintained. The additional functions that have been built into the system have reduced the potential for human error and increased the overall efficiency of the Waste Management department through the use of the automated report generation functionality. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Database dedicated to nuclear criticality events that occurred in fuel cycle facilities

Nuclear fuel cycle facilities can encounter events, resulting from human errors, failure of safety organization or technical failures. However, the application of the concept of defense in depth, especially the first two levels (prevention of abnormal situations and detection) requires to ensure safety in such undesirable situations. Furthermore, the periodic safety reviews of each nuclear fuel cycle facility involve the evaluation of the safety of these facilities with regard to the regulation evolution, the best safety practices, the facility evolution (modifications, aging...) and the global feedback. Part of this work is based on the analysis of the feedback and lessons learned from the events that occurred during the past period. This specific work indeed provides lessons about the operating conditions of the facility and highlights malfunctions that have occurred during operations, maintenance or restart after a shutdown. Taking into account this feedback, IRSN developed a database gathering the events which have affected the safety of French fuel cycle facilities (from conversion to waste storage, laboratories and experimental facilities, facilities under dismantling and decommissioning). Among all the recorded events, it is possible to extract in particular those impacting the criticality safety. In order to extend the analysis of these events, the IRSN criticality safety department developed a specific database dedicated to criticality risks. The 'criticality events' database is continuously updated on the basis of the declared events and their analysis by engineers from the criticality safety department. At this time, about 600 events are described and analyzed in this database. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Template engine applied to rapid modeling

Modeling complex problems can require a significant effort, be subject to human error, and contain repeated patterns of input. SCALE 6.2 and the Used Nuclear Fuel-Storage, Transportation and Disposal Analysis Resource and Data System (UNF-ST-DARDS) have attempted to mitigate these problems with the use of a template engine and template syntax. The template syntax allows redundant input to be consolidated into its simplest pattern and parameterized on the parts that change, reducing effort and likelihood of errors and encapsulating user experience into a reusable model component. This paper presents a summary of rapid modeling benefits and techniques that are facilitated when using templates. Specifically, this paper will discuss how these are applied in conducting as-loaded spent nuclear fuel canister criticality calculations using UNF-ST-DARDS and model perturbation and sampling using SCALE 6.2. (authors)

42 ENGINEERING↗

Numerical simulation of break flows occurring in the reactor cavity cooling system of a very high temperature reactor using a system CFD approach - 18437

To avoid accidents due to human error or the failure of components, the reactor cavity cooling system (RCCS) of a high temperature reactor must be able to operate naturally or passively safe. The system under consideration in this investigation is an air-cooled system which consists of an annular downcomer which is connected via a bottom-header to riser tubes. The downcomer and riser tubes are connected to the atmosphere via inlet and outlet manifold systems respectively. In this study the entire system is simulated using the 1D network codes GAMMA+ and Flownex. The study investigates the effect that breaks, causing a short circuit between one half of the inlet manifold and the corresponding half of the outlet manifold, will have on the performance of the cooling system. The agreement between the results obtained with the two codes is good. When the break size exceeds a certain value the flow may reverse in the relevant half of the outlet manifold. The critical break size is dependent on the elevation at which the break occurs. The reversal in the flow results in a drop of 10% in the heat removal capacity of the RCCS. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of human machine interface (HMI) for digital control rooms in nuclear power plants - 119

The analog control systems of traditional Nuclear Power Plants (NPPs) are being replaced by digital systems due to the fact that analog Instrumentation and Control (I and C) systems are becoming obsolete and such technology is no longer supported by manufacturers. The purpose of this study is to jointly evaluate the performance of an operator with a Human Machine Interface (HMI) in a NPP digital control room ensuring the efficiency and the safety of the NPP. The validity and the accuracy of the operators' actions are the primary goals that have to be preserved through the emergence of the HMI based in digital systems. The transition from analog to digital control systems leads to a more advanced support of the NPP; Video Display Units (VDUs) are used for monitoring the state of the NPP while alarm systems help for directing attention. The operators, in order to monitor information from the different VDUs, have to switch attention between different screens (alarms systems and control systems). Therefore, a well-established HMI is a significant challenge to the overall operation of the NPP, that actually helps the operators to learn from the available information in detecting possible anomalies and making the right decisions, to ensure safety, and in parallel to diminish the human error. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computerized procedure systems: procedure edition and maintenance challenges - 232

Very few nuclear power plants are using computerized procedures to guide the control room operation. A CPS implementation consists of two processes: digitalization and computerization. The former deals with the transformation of paper-based procedure into a digital data; the latter is referred to as the addition to that data of extra information that is meaningful for decision-making. This information may include real-time data (plant parameter values and binary process values to indicate equipment states), provide access to trends and historical data, etc. In order to be efficient and to optimize the digitalization and computerization processes, these set of aids should be implemented at the same time as operating procedures are digitalized There are references of plants having successfully implemented Computerized Procedures Systems (CPS) for emergency procedures, but when questioned about normal or abnormal operating procedures, operators and plant management seem reluctant to take that step. Given that a CPS is meant, by design concept, to increase operation crew efficiency by facilitating the procedures execution and reducing human error, why are we reluctant to enjoy CPS benefits in the most common plant status (i.e. normal operation)? Although there are many answers to this question, one is shared by most of the users: CPSs are not designed for editing and maintaining procedures easily and reliably. Normal operating procedures, in opposition to the emergency procedures, are often reviewed. Nowadays, these edition activities are performed easily with a word processor software and using paper, but what is required when dealing with a CPS? (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On-Line Monitoring to Detect Sensor and Process Degradation under Normal Operational Transients - 327

Calibration assessment of nuclear plant sensors and transmitters is currently performed through periodic maintenance actions during plant refueling outages. On-line monitoring (OLM) can be used to reduce the time and cost of this maintenance process by using empirical models to evaluate sensor calibration. The implementation of OLM can also mitigate human error associated with unnecessary maintenance on sensors operating within calibration tolerances. OLM has been studied and validated for plants under steady-state baseload operation, but the extension to load-following operation is not well-documented in the literature. Auto-associative kernel regression (AAKR) provides an error-corrected prediction of process sensor measurements for OLM through a weighted average of historic data. The current study evaluates the performance of AAKR for prediction under normal operational transients (such as expected under load-following operation). Performance of the AAKR model with two anomaly detection routines, error uncertainty limit monitoring (EULM) and sequential probability ratio test (SPRT), was evaluated for normal operation, sensor faults, and process degradation. The data used to develop and evaluate the OLM system were collected from a forced flow loop with temperature and flow sensors. Three models of well-correlated groups of sensors are trained to predict normal system behavior under planned transients. The anomaly detection routines are tested for sensor faults and process faults. The results of this experimental study suggest AAKR and an appropriate anomaly detection routine can be applied for sensor calibration and process fault detection under transient operation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Systems Engineering (SE) Approach of Developing A Passive Safety Injection System (PSIS) to Cope with APR1400 Extended Station Black-Out (SBO) Accident Using RELAP5

On 11 March 2011 the power supply and cooling of the three Fukushima Daiichi reactors were disabled by a major earthquake followed by a relatively high tsunami waves. The earthquake damaged the electrical grid which is the normal power supply for the reactors, then the tsunami waves disabled the emergency diesel generators of the Fukushima Daiichi reactors, which left the plant with no alternating current (AC) source. This condition is called 'Station Black-Out'. The reactors were tripped immediately, but due to the nuclear physics phenomena, the reactor cores were still producing thermal power, which is generated by the decay of radioactive fission products in the reactor core, known as decay heat. The decay heat had not been circulated to an external heat sink and eventually the accumulative heat produced in the core led to damage to the reactor cores. After the Fukushima Daiichi accident, Design Extension Condition (DEC) such as total loss of feed water (TLOFW), and prolonged Station Black-Out (SBO) attracted the attention of nuclear experts. The attention focuses on the defense in depth concept, redundancy and sustainability of the systems, and development of the passive safety systems, which rely on natural physics laws. The topic of this paper is to discuss the possibility of attaching a Passive Safety Injection System (PSIS) to the APR1400. The PSIS is a safety system which provides adequate cooling water to the steam generators after the loss of the Auxiliary Feed Water System (AFWS) during an extended SBO accident. The PSIS will be available while the power supply of the plant is being recovered and the active safety systems take over the functionality. The anticipated PSIS will be automatically actuated to enhance the engineered safety feature and to reduce the human errors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NUTRON NESHAPs Dashboard

My project aims to enhance the Nuclear Material Tracking Application (NUTRON) software by integrating a tool for the National Emission Standards for Hazardous Air Pollutants (NESHAP) emissions calculations and presenting this data on a dashboard. Inefficiencies in the current NESHAP calculation process were addressed, which will result in more timely regulatory compliance efforts. Key improvements include revising the transfer request system, incorporating effective dose calculations, and developing a data visualization dashboard into NUTRON. The project involved creating a wireframe, preparing an Engineering Calculations and Analysis Report (ECAR), stakeholder meetings, and providing supplemental documentation. Key findings indicate that the proposed modifications will streamline the NESHAP calculation process, reduce human error, and provide REC personnel with accurate and timely data for material use determinations and dose estimations. Future work focuses on completing the NUTRON modifications and fully integrating the new features, ensuring a more efficient and reliable system for tracking and reporting nuclear material transfers.

99 - GENERAL AND MISCELLANEOUS↗