Small Hydro Power Plants with Integrated BESS for Enhance Resiliency

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a black start- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFM controlled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Roadmap for Advanced Power System Measurements

Conditions in the electric power grid are changing rapidly. Changes are driven, in particular, by the increased penetration of renewable resources in the generation mix. Part of the solution to dealing with the changing conditions is the better use of measurement systems, taking advantage of the better understanding of measurements that was heralded by digital technology. Another part of the solution is the communication of samples of the directly observable voltages and currents by means of continuous point-on-wave values. The increased bandwidth capability of such a system allows more complicated measurement models to be built at the point of use. Additional measurements and analyses can then be performed. This Roadmap hinges on these two aspects of measuring: improved measurements supported by high-bandwidth (raw data) communications. Following an introduction to the overall subject, the report explores the impact of what can be thought of as the digital revolution in measurement. In essence, that revolution has served to clarify ideas about measurement and is continuing to lead to improved processes. An extensive survey of the relevant literature was performed . Webinars were held to learn from the wider community of practitioners. Based on this information, a number of gaps were identified whose continued existence would hamper the solution of the challenges now facing measurement and communication in the power grid. The underlying value propositions are interoperability (presently not very satisfactory in many measurements); greater (and less challenging) adoption of distributed energy resources; and improved international competitiveness. Underlying all that, of course, is progress toward a more reliable and resilient power system. The identified gaps were addressed in four major thrusts: technology deployment and demonstration, education, instrumentation testing and standards, and analytical methods. For each of the thrusts, multiple goals are defined to guide the implementation. The thrusts were designed to close gaps and unlock high-value use cases. After discussing the literature review, gap analysis, high-value use cases, and research thrusts in chapters 2-5, the report culminates in chapter 6 with a roadmap that links each aspect together to form a unified plan. Developing a research portfolio aligned with this plan will ensure that advanced measurement systems are in place to support reliable operation of the power system as it modernizes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation: Preprint

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., lost a large generation unit). The NLM engine is a central dispatch control system that provides high-speed cost-optimal coordination of a set of net loads (combination of generation and deferrable loads) connected to the same electrical network. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm. The experimental results indicate that the NLM engine can achieve the targeted system voltage and frequency and balance load and generation to serve the critical facility.

droop control↗

Mathematical Modeling of Hydroxide-Exchange-Membrane Water Electrolyzer

Water electrolyzers can transform intermittent renewable energy like solar energy and wind energy into the chemical energy of hydrogen with zero greenhouse-gas emissions. The hydroxide-exchange membrane electrolyzer (HEME) combines the capability to produce pressurized hydrogen with the advantage of being able to use low or non-platinum group metal (PGM) electrocatalysts in the alkaline environment.1 Hydroxide salts, for example, KOH, are added to the HEME water feed on both anode and cathode to improve its performance. However, the specific mechanism of performance improvement still needs to be further understood. In addition, at high current densities, bubble evolution can result in mass-transport limitations, a less well studied phenomena. Mathematical modeling is ideal to explore these issues as it is cost and time efficient and can deconvolute the physics, processes, and observed phenomena and study the applied-voltage breakdown. In this work, we extend our previously developed 1D two-phase continuum model2 to study the varies processes in the HEME and provide insights on performance optimizations. First, the oxygen evolution reaction (OER) and hydrogen evolution reaction (HER) kinetics at different hydroxide concentrations have been studied by rotating disk electrodes (RDE) and implemented in the model. Then, the model is calibrated and validated against experimental HEME polarization curves for different KOH concentrations as a liquid electrolyte. The model clearly shows a performance increase with increasing KOH concentrations, which is consistent with the experimental results. The reduced ohmic resistance and increased electrochemical active surface area (ECSA) are the two main reasons for performance increase. The large amount of hydroxide in the liquid electrolyte not only helps to distribute the reactant hydroxide throughout the catalyst layer (CL), which reduces ohmic loss, but also enables reaction at the interface between the liquid electrolyte and electrocatalyst, which increases the ECSA. Applied-voltage breakdown demonstrates that the electrolyzer performance is dominated by anode kinetics and ohmic loss. A comparison with the DI water feed shows a more uniform current distribution in the anode CL when KOH is added, which indicates a higher utilization of the CL. Second, we present modeling on the effects of bubble coverage. As gas evolves, part of the ECSA is minimized due to bubble coverage. To account for this effect, an empirical relationship between the fractional bubble coverage and the current density is implemented in the model.3 The model shows this bubble coverage effect is more pronounced at large current densities with DI water feed. Acknowledgements This work was funded under the HydroGEN Consortium by the Energy Efficiency and Renewable Energy, Hydrogen and Fuel Cell Technologies Office, of the U. S. Department of Energy under contract number DE-AC02-05CH11231. References R. Abbasi, B. P. Setzler, S. Lin, J. Wang, Y. Zhao, H. Xu, B. Pivovar, B. Tian, X. Chen, G. Wu and Y. Yan, 31, 1805876 (2019). L. N. Stanislaw, M. R. Gerhardt and A. Z. Weber, ECS Transactions, 92, 767 (2019). H. Vogt and R. J. Balzer, Electrochimica Acta, 50, 2073 (2005).

Liu, Jiangjin↗

Structural, Electrochemical, and (De)lithiation Mechanism Investigation of Cation-Disordered Rocksalt and Spinel Hybrid Nanomaterials in Lithium-Ion Batteries

Significant demand for lithium-ion batteries necessitates alternatives to Co- and Ni-based cathode materials. Cation-disordered materials using earth-abundant elements are being explored as promising candidates. Here, in this paper, we demonstrate a coprecipitation synthetic approach that allows direct preparation of disordered rocksalt Li 2.4 Fe 1.0 Ti 1.0 O 4.7 (r-LFTO·C) and spinel structured hybrid Li 0.5 Fe 1.0 Ti 0.9 O 3.2 ·C (s-LFTO·C) nanoparticles with a conformal conductive carbon coating. High-angle annular dark-field imaging coupled with electron energy loss spectroscopy mapping shows uniform Fe/Ti distribution with minor compositional variation among particles. Cation disorder was confirmed for both of the materials at an atomic level, with a short-range order more pronounced in r-LFTO·C. Operando X-ray absorption spectroscopy, ex situ hard X-ray photoelectron spectroscopy, ex situ soft X-ray absorption spectroscopy, and ex situ synchrotron X-ray diffraction were used to investigate (de)lithiation in the bulk and at the surface. Structurally, the r-LFTO·C demonstrated reversible partial Fe center migration between octahedral and tetrahedral sites during (de)lithiation. The r-LFTO·C evidenced that the redox of O was coincident with iron redox during initial electrochemical cycling, while iron redox dominated later cycling. In contrast, s-LFTO·C electrochemistry involved iron redox throughout the cycling process. The findings rationalize the differences in the electrochemistry where r-LFTO·C shows higher initial capacity yet poorer capacity retention over a voltage window where O redox can be accessed, while the s-LFTO·C shows lower initial capacity yet improved capacity retention.

25 ENERGY STORAGE↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗

Interpretable Data-Driven Probabilistic Power System Load Margin Assessment with Uncertain Renewable Energy and Loads

The increasing uncertainties caused by the high-penetration of stochastic renewable generation resources poses a significant threat to the power system voltage stability. To address this issue, this paper proposes a probabilistic deep kernel learning enabled surrogate model to extract the hidden relationship between uncertain sources, i.e., wind power and loads, and load margin for probabilistic load margin assessment (PLMA). Unlike other deep learning approaches, a kernel SHAP provides the sensitivity analysis as well as interpretability of the inputs to outputs influences. This allows identifying the critical factors that affect load margin so that corrective control can be initiated for stability enhancement. Numerical results carried out on the IEEE 118-bus power system demonstrate the accuracy and efficiency of the proposed data-driven PLMA scheme.

deep kernel learning↗

Three-dimensional modelling of a self-sustained atmospheric pressure glow discharge

The atmospheric pressure glow discharge (APGD) is a relatively simple and versatile plasma source used in diverse applications. Stable APGD operation at high currents, generally a challenge due to instabilities leading to glow-to-arc transition, has been demonstrated using actively-controlled cathodic cooling. This article presents the computational modelling and simulation of a self-sustained direct-current APGD in helium within a 10 mm pin-to-plate inter-electrode gap for currents ranging from 4 to 40 mA. The APGD model is comprised of the conservation equations for total mass, chemical species, momentum, thermal energy of heavy-species and of free electrons, and electric charge. The model equations are discretized using a nonlinear variational multi-scale finite element method that has demonstrated superior accuracy in other plasma flow problems, on a temporal and three-dimensional computational domain suitable to unveil the potential occurrence of instabilities. Modelling results show good agreement with experimental measurements of voltage drop and the same trend but higher values of temperature. The higher temperatures obtained by the simulations appear to be due to the absence of a near-cathode heat dissipation model. Here, the results also reveal that the distribution of electron density and of the ratio of atomic helium ions to total ions transitions from monotonically increasing away from the cathode to presenting a minimum near the centre of the gap with increasing current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient Measurement of Length Distribution of 1D Nanoparticles in Solution via Optical Polarimetry

The efficient measurement of the length distribution of nanotubes, nanowires, and other one-dimensional (1D) nanoparticles in solution is important to enable their incorporation into materials and devices and to optimize their processing for properties of interest, such as thermal/electrical conductivity or mechanical strength, in suspensions and composites. We report an electric-field (E-field)-assisted optical-polarimetry technique to measure the length distribution of ensembles of high-aspect-ratio particles in dilute suspension. The degree of alignment of polarizable 1D particles suspended in a fluid under Brownian motion explicitly depends on the E-field strength and the particle length. We show that it is possible to extract the length distribution of 1D nanoparticles suspended in an insulating fluid by applying a range of E-fields and using optical polarimetry to measure the corresponding alignment order parameter. Notably, the method is relatively insensitive to the diameter of the 1D particles, which can be poorly known or vary within a sample. The technique is validated with silver nanowires and carbon nanotubes of known lengths, as well as polymer-depletion-length-separated single-wall carbon nanotube samples with length distributions independently measured with analytical ultracentrifugation. Finally, we demonstrate the ability of the optical-polarimetry technique to quantify changes in the length distribution of ultranarrow, sub-nanometer-diameter single-wall carbon nanotubes under different types and durations of ultrasonication. Within its range of applicability (polarizable 1D nanoparticles in the 0.5 to 15 μm length range, constrained by the voltage stability of the media and the suspended particles), the E-field-assisted optical-polarimetry method is a particularly efficient and accurate method to measure the length distribution of nanowires and nanotubes in suspension.

1D nanoparticles↗

Edge States Drive Exciton Dissociation in Ruddlesden–Popper Lead Halide Perovskite Thin Films

Efficient photovoltaic cells based on thin films of solution-processed 2D Ruddlesden–Popper hybrid perovskites (RPPs) represent an exciting breakthrough due to their enhanced tunability and chemical stability relative to those fabricated from 3D phases. However, reports of efficient charge separation and current collection are in apparent contradiction with the well-known enhancement of the exciton binding energy in multilayered halide perovskites, which should lower the device’s internal quantum efficiency and voltage. This controversy has led to various proposals for the electronic and physical structure of RPP thin films, including phase inhomogeneity as the driving force for exciton dissociation and transport. We address this apparent paradox in high-quality hot-cast RPP films by correlating ultrafast transient absorption spectroscopy with X-ray scattering measurements. We show that a hot-casting fabrication method produces highly phase pure n = 3 (BA) 2 (MA) n-1 Pb n I 3n+1 RPP structures. The high-phase purity and large grain sizes allow us to observe vertical transport of excitons via a diffusive process and allow us to determine that charge separation is primarily driven by dissociation at surface localized subgap electronic states. Furthermore, we analyze the differential absorption kinetics in films of varying thickness to directly determine that the excitonic diffusion constant is ~0.18 cm 2 s –1 . We propose that a surface localized structural distortion, observed using surface selective grazing incidence X-ray scattering measurements, is responsible for the creation of the surface localized defect states. We find that the density and spatial distribution of these defect states is a function of preparation conditions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

State-of-the-Art Medium- and High-Voltage Silicon Carbide Power Modules, Challenges and Mitigation Techniques: A Review

Silicon carbide (SiC) power modules have been demonstrated potential for improving power density and efficiency for low-voltage power electronics systems. This has resulted in a paradigm shift toward development of medium-voltage and high-voltage (MV/HV) SiC power modules to revolutionize the future power grid and transportation systems. However, designing MV/HV SiC power modules involves significant design challenges due to higher blocking voltage and exacerbation of side effects due to high switching dv/dt and di/dt of SiC devices-concerns that may not be as critical as in low-voltage module development. This article reviews the development of state-of-the-art MV/HV SiC power modules, ranging from 3.3 kV to 40 kV, from both industry and academia. First, a discussion on SiC modules based on voltage level is presented. This is followed by a discussion of challenges associated with designing and testing MV/HV modules- including parasitic controls, electromagnetic interference (EMI), partial discharge, and thermal management-and the corresponding mitigation approaches from various perspectives. We conclude with a summary of major findings and future directions for the development of MV/HV modules.

EMI↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

The Value of Increased HVDC Capacity Between Eastern and Western U.S. Grids: The Interconnections Seam Study

The Interconnections Seam Study examines the potential economic value of increasing electricity transfer between the Eastern and Western Interconnections using high-voltage direct-current (HVDC) transmission and cost-optimizing both generation and transmission resources across the United States, proposing, assessing, justifying, and illustrating a major infrastructure change involving two of the worlds largest power grids. The study conducted a multi-model analysis that used co-optimized generation and transmission expansion planning and production cost modeling. Four transmission designs under eight scenarios were developed and studied to estimate costs and potential benefits. The results show benefit-to-cost ratios that reach as high as 2.5, indicating significant value to increasing the transmission capacity between the interconnections under the cases considered, realized through sharing generation resources and flexibility across regions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HEMP Transformer Defense Through Power Electronics

High altitude electromagnetic pulses and geo-magnetic disturbances have the potential to severely impact the electric power grid by damaging large power transformers and causing severe power quality issues. This impact comes as a result of a quasi-static bias induced on transmission lines by geomagnetically induced currents which saturate magnetic components in the electric power system. This paper introduces the concept of utilizing a h-bridge inverter on the neutral of a LPT to inject a DC bias equivalent voltage onto the neutral side of the transformer windings. This biasing floats the transformer windings, eliminating the effect of the DC current and keeping the transformer from saturating. Schematic diagrams will be presented, along with simulation model data using Typhoon and PLECS, and finally test results from a benchtop hardware test.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quench protection for high-temperature superconductor cables using active control of current distribution

Superconducting magnets of future fusion reactors are expected to rely on composite high-temperature superconductor (HTS) cable conductors. In presently used HTS cables, current sharing between components is limited due to poorly defined contact resistances between superconducting tapes or by design. The interplay between contact and termination resistances is the defining factor for power dissipation in these cables and ultimately defines their safe operational margins. However, the current distribution between components along the composite conductor and inside its terminations is a priori unknown, and presently, no means are available to actively tune current flow distribution in real-time to improve margins of quench protection. Also, the lack of ability to electrically probe individual components makes it impossible to identify conductor damage locations within the cable. In this work, we address both problems by introducing active current control of current distribution between components using cryogenically operated metal-oxide-semiconductor-field-effect transistors (MOSFETs). We demonstrate through simulation and experiments how real-time current controls can help to drastically reduce heat dissipation in a developing hot spot in a two-conductor model system and help identify critical current degradation of individual cable components. Finally, prospects of other potential uses of MOSFET devices for improved voltage detection, AC loss-driven active quench protection, and remnant magnetization reduction in HTS magnets are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Early-Time (E1) High-Altitude Electromagnetic Pulse Effects on Transient Voltage Surge Suppressors

Determining the effectiveness of surge and pulse protection devices in the United States power grid against effects of a High-Altitude Electromagnetic Pulse (HEMP) is crucial in determining the present state of grid resilience. Transient Voltage Surge Suppressors (TVSS) are used to protect loads in substations from transient overvoltages. Designed to mitigate the effects of lightning, their response to a HEMP event is unknown and was determined. TVSSs were tested in two unique configurations using a pulser that generates pulses in the tens of nanoseconds scale to determine their protective capability as well as to determine their self-resilience against HEMP pulses. Testing concluded that TVSS devices adequately protect against microsecond scale pulses like lightning but do not protect against pulses resembling HEMP events. It suggests that TVSS devices should not be relied upon to mitigate the effects of HEMP pulses.

24 POWER TRANSMISSION AND DISTRIBUTION↗