Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Helium cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Superfluid-Tight Cryogenic Receiver With Continuous Sub-Kelvin Cooling for EXCLAIM

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 – 540 GHz frequency range. EXCLAIM uses a fully cryogenic telescope coupled to six on-chip spectrometers featuring kinetic inductance detectors (KIDs) to achieve high sensitivity, allowing for fast integration in dark atmospheric windows. The telescope receiver is cooled to ≈ 1.7 K by immersion in a superfluid helium bath and enclosed in a superfluid-tight shell with a meta-material anti-reflection coated silicon window. In addition to the optics and the spectrometer package, the receiver contains the magnetic shielding, the cryogenic segment of the spectrometer readout, and the sub-Kelvin cooling system. A three-stage continuous adiabatic demagnetization refrigerator (CADR) keeps the detectors at 100 mK while a 4He sorption cooler provides a 900 mK thermal intercept for mechanical suspensions and coaxial cables. We present the design of the EXCLAIM receiver and report on the flight-like testing of major receiver components, including the superfluid-tight receiver window and the sub-Kelvin coolers.

continuous adiabatic demagnetization refrigerator↗

Effects of break geometry and orientation on helium-air mixing in simulated reactor cavities of high temperature gas reactors

Here, this study experimentally examined the spatial and temporal variations in air and helium concentrations and temperature fields within simulated reactor cavities of a High Temperature Gas Reactor (HTGR) following helium discharge into an initially air-filled reactor cavity system. Detailed temperature maps were generated using a combination of fiber optics temperature sensor and multiple thermocouple probes within the simulated reactor cavities. The research scenario involved a hypothetical small pipe break in the Reactor Pressure Vessel, resulting in the release of high-temperature helium into the surrounding cavity. A scaled multi-compartment experimental facility, modeled after the General Atomics Modular High Temperature Gas Reactor (GA-MHTGR) design, was constructed for helium and air mixing experiments. Oxygen sensors and thermocouple probes were installed in all five cavities to measure the concentrations of oxygen (or helium) and the temperature distributions of the gas mixture. The experimental findings highlighted the significant impact of the injected helium jet velocity on the gas mixing process and demonstrated how the direction of the helium jet influences the air-helium temperature profiles within the cavities.

Air-ingress↗

Blind Leak Detection for Closed Systems

The current inspection technique for locating interstitial leaking in the Space Shuttle Main Engine nozzles is the application of a liquid leak check solution in the openings where the interstitials space between the tubing and the structural jacket vent out the aft end of the nozzle, while its cooling tubes are pressurized to 25 psig with Helium. When a leak is found, it is classified, and if the leak is severe enough the suspect tube is cut open so that a boroscope can be inserted to find the leak point. Since the boroscope can only cover a finite tube length and since it is impossible to identify which tube (to the right or left of the identified interstitial) is leaking, many extra and undesired repairs have been made to fix just one leak. In certain instances when the interstitials are interlinked by poor braze bonding, many interstitials will show indications of leaking from a single source. What is desired is a technique that can identify the leak source so that a single repair can be performed. Dr, Samuel Russell and James Walker, both with NASA/MSFC have developed a thermographic inspection system that addresses a single repair approach. They have teamed with Boeing/Rocketdyne to repackage the inspection processes to be suitable to address full scale Shuttle development and flight hardware and implement the process at NASA centers. The methods and results presented address the thermographic identification of interstitial leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera (capable of detecting a delta temperature difference of 0.025 C) is used to record the cooling effects associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner hot wall surface as the nozzle is pressurized, These images are enhanced by digitally subtracting a thermal reference image taken before pressurization. The method provides a non-intrusive way of locating the tube that is leaking and the exact leak source position to within a very small axial distance. Many of the factors that influence the inspectability of the nozzle are addressed; including pressure rate, peak pressure, gas type, ambient temperature and surface preparation. Other applications for this thermographic inspection system are the Reinforced-Carbon-Carbon (RCC) leading edge of the Space Shuttle orbiter and braze joint integrity.

Oelgoetz, Peter↗

Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads

Astrophysical observations at millimeter wavelengths require large (2-to-5- meter diameter) telescopes carried to altitudes above 35 km by scientific research balloons. The scientific performance is greatly enhanced if the telescope is cooled to temperatures below 10 K with no emissive windows between the telescope and the sky. Standard liquid helium bucket dewars can contain a suitable telescope for telescope diameter less than two meters. However, the mass of a dewar large enough to hold a 3-to-5-meter diameter telescope would exceed the balloon lift capacity. The solution is to separate the functions of cryogen storage and in-flight thermal isolation, utilizing the unique physical conditions at balloon altitudes. Conventional dewars are launched cold: the vacuum walls necessary for thermal isolation must also withstand the pressure gradient at sea level and are correspondingly thick and heavy. The pressure at 40 km is less than 0.3% of sea level: a dewar designed for use only at 40 km can use ultra thin walls to achieve significant reductions in mass. This innovation concerns new construction and operational techniques to produce a lightweight liquid helium bucket dewar. The dewar is intended for use on high-altitude balloon payloads. The mass is low enough to allow a large (3-to-5-meter) diameter dewar to fly at altitudes above 35 km on conventional scientific research balloons without exceeding the lift capability of the balloon. The lightweight dewar has thin (250- micron) stainless steel walls. The walls are too thin to support the pressure gradient at sea level: the dewar launches warm with the vacuum space vented continuously during ascent to eliminate any pressure gradient across the walls. A commercial 500-liter storage dewar maintains a reservoir of liquid helium within a minimal (hence low mass) volume. Once a 40-km altitude is reached, the valve venting the vacuum space of the bucket dewar is closed to seal the vacuum space. A vacuum pump then evacuates the dewar vacuum space to provide the necessary thermal isolation. Liquid helium may then be transferred from the storage dewar into the bucket dewar to cool the telescope inside the bucket dewar. By splitting the functions of helium storage and in-flight thermal isolation, the parasitic mass associated with the dewar pressure vessel is eliminated to achieve factor-of-five or better reduction in mass. The lower mass allows flight on conventional scientific research balloons, even for telescopes 3 to 5 meters in diameter.

Kogut, Alan↗

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗

Passive heat removal in horizontally oriented micro-HTGRs

There are novel, horizontally oriented high-temperature gas-cooled micro-reactor (HTGR) designs under consideration because of their portability, simplicity, and reliable operation. These features of the micro-HTGR design can meet the fission battery attributes, such as economic, standardize, installed, unattended and reliable. Although there have been HTGR related safety studies, micro-HTGRs when horizontally oriented are expected to exhibit significantly different thermal physics. During the unavailability of helium circulation, the internal reactor core is designed to cool by block-to-block conduction and radiation, and the reactor vessel surface is cooled by the ambient air. This scenario is anticipated during the transport of the micro-HTGR in a shipping container. The conduction and radiation between the prismatic micro-HTGR blocks in the core can be influenced by variances in the thermal contacts. This work investigated the conduction within a simulated horizontal HTGR core. An experimental setup was used to validate a numerical model. The experimental setup consisted of a hexagonal assembly with scaled prismatic blocks placed within a high-temperature vacuum environment. The gaps between the blocks were well controlled and monitored. The experimental setup was designed in such a way that the temperature variation in the axial direction was minimal, such that the experiment could be observed as a 2D (r, ) heat transfer problem. The pressurized tube was equipped with Infra-Red (IR) transparent windows, and an IR camera was used to capture the spatio-temporal temperature evolution in the hexagonal block assembly during the cooldown experiments. The experimental scenario was computationally modeled with a finite element analysis (FEA) program. Once validated, the computational model was used to investigate the impact of gap conductance on overall decay heat removal. Using a conservative estimate for gap conductance value (100 W/m 2 -K) between the prismatic blocks, there is a negligible increase in temperature observed during decay heat generation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Ambient Inert Gas Properties on Cool-Flame Combustion of Normal-Alkane Droplets in Microgravity

Cool-flame-supported quasi-steady droplet combustion was first observed during droplet combustion experiments conducted onboard the International Space Station (ISS) in the Combustion Integrated Rack (CIR) with n-alkane fuels. These cool flames, not visible to the naked eye, result from the existence of the negative-temperature-coefficient (NTC) region during the combustion n-alkane fuels when the chemical-kinetic pathways experience a transition from the low-temperature chemistry to the normal, high-temperature-controlled chemistry. In this study, we present results for the cool-flame-supported droplet burning rates and extinction diameters for n-alkane fuels (n-heptane, n-octane, n-decane, and n-dodecane) in inert-diluent-substituted ambient environments. In these ISS experiments, some of the nitrogen in the ambient gas mixture is replaced by an inert gas, namely, carbon dioxide, helium, or xenon. Different diluents were observed to exert remarkably different influences on the cool-flame combustion of fuel droplets. The results show that the cool-flame extinction diameter is drastically increased with helium dilution compared to N2, CO2 or Xe, and Xe dilution leads to longer burning with a smaller extinction diameter. Unlike hot flames, the cool-flame burning rates are controlled by the cool-flame temperature established in the NTC region by the chemical kinetics, rather than by equilibrium thermodynamics, and the thermo-physical properties of the ambient gases, which control the heat feed back to the liquid droplet. The cool-flame extinction is triggered by the instability that occurs at the low-temperature end of the NTC region, below which cool diffusion flames become statically unstable. A quasi-steady theoretical model, presented earlier, which involves a six-step reduced-chemistry mechanism, valid around the lower end of the NTC region, is shown to explain the observed experimental trends qualitatively.

microgravity↗

Experimental analysis of gas dynamics in the reactor cavity section of a High-Temperature Gas-Cooled Reactor during an accident scenario

Here, this study investigates the behavior of a High-Temperature Gas-Cooled Reactor (HTGR) during a break of the helium pressure boundary event. Understanding the gas dynamics that occur during a break could help develop safety systems that reduce the probability of air entering the reactor core. To achieve this objective, experimental studies were conducted in a scaled-down HTGR experimental facility to provide information on the air-helium gas mixture within the confinement building and the impact of the ventilation system on the helium/air gas concentration following the depressurization event. The study evaluated different configurations, including active ventilation time scales, break sizes, and locations. The analysis of the active ventilation time revealed that a ventilation time of 22 seconds produced positive results, and smaller break sizes resulted in longer depressurization times, which improved the ventilation process. The orientation and elevation of the breaks had little effect on the oxygen concentration in the cavity but did impact the gas velocities.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Nanostructured Alumina Forming Austenitic Alloy (NAFA) Production Using Mechanical Alloying and High-Temperature Consolidation

Alumina-forming austenitic (AFA) alloys are a promising class of nuclear materials because of their high-temperature oxidation/corrosion resistance and mechanical properties. Unfortunately, these alloys are limited in use for core material applications, and they are specifically limited for use as nuclear fuel cladding because of their high Ni-transmutation and helium generation rate in-service. Improving these alloys through a fine dispersion of oxide precipitates and thus increasing the effective irradiation sink strength of the alloy system may mitigate many of the degradation phenomena expected during alloy deployment. These phenomena include high-temperature helium embrittlement and cavity swelling for lead-cooled fast reactor applications. This work effort uses combination of conventional and advanced manufacturing approaches are being used to fabricate nanostructured AFA (NAFA) materials. As the first objective of this initiative, a conventional AFA was modified using mechanical alloying and extrusion to alter the precipitation characteristics to include a fine dispersion of nanoscale oxides intended to serve as traps for irradiation-induced point defects and transmuted He within the lattice. This analysis compared the efficacy of the conventional mechanical alloying and extrusion approach with the unalloyed AFA consolidated approach using hot isostatic pressing (HIP). It was found that, although the mechanical alloying approach is successful in producing a fine distribution of oxides within the first nanostructured AFA (NAFA-1), the distribution is heterogeneous because of the mild milling parameters used to prevent cold welding of powder to the spherical milling media. The additional dispersion of oxides, coupled with a higher volume fraction of other secondary phases in the NAFA-1, produces higher alloy strengths that range up to 600°C in comparison to the unalloyed HIP AFA, thus exceeding the operating temperature of lead-cooled fast reactors. However, the strength of the NAFA-1 is lower than that of the HIP AFA at 800°C, which is presumed to be a function of increased secondary phases from the nonoptimized AFA chemistry. Future work is planned on a newly procured NAFA-2 chemistry that is more suitable for advanced reactor applications exploring new manufacturing routes.

36 MATERIALS SCIENCE↗

Nanostructured Alumina Forming Austenitic Alloy (NAFA) Production using Advanced Manufacturing

Alumina-forming austenitic (AFA) alloys are well known for their exceptional corrosion-resistant properties due to the formation of a dense oxide scale beneficial in their application as a nuclear material. However, use of the alloys in core material applications is limited due to the high nickel-transmutation and helium generation rate in service, leading to swelling and reduced lifetimes. Enhancing the sink strength to pin gas bubbles and increasing gas management of the material may mitigate many of the degradation phenomena expected during alloy deployment (such as high-temperature helium embrittlement and cavity swelling for lead-cooled fast-reactor applications). Nanostructured materials are usually produced using a time-consuming and expensive batch process like mechanical alloying to achieve the fine homogenous distribution of nanoprecipitates throughout the matrix material. Integrating the nanoprecipitates in modern additive manufacturing processes has proven difficult, as the required nano-sizes or number densities cannot be achieved simultaneously. Efforts to increase the number density of precipitates by adding more precipitate-forming rare-earth elements led to agglomeration of such elements, while the nano-sized precipitates did not form in sufficient quantity when not enough rare-earth element was use. In this work a novel approach to advanced manufacturing and the fabrication of Nanostructured AFA (NAFA) materials was chosen. A dual precipitate-forming NAFA steel with a chemistry more suitable for advanced reactor applications was produced to create an environmentally resistant, high-sink-strength austenitic alloy for advanced reactor cladding applications.

36 MATERIALS SCIENCE↗

Nanostructured Alumina-Forming Austenitic Alloy (NAFA) Production Using Advanced Manufacturing

Alumina-forming austenitic (AFA) alloys are well known for their exceptional corrosion-resistant properties due to the formation of a dense oxide scale beneficial in their application as a nuclear material. However, use of the alloys in core material applications is limited due to the high nickel-transmutation and helium generation rate in service, leading to swelling and reduced lifetimes. Enhancing the sink strength to pin gas bubbles and increasing gas management of the material may mitigate many of the degradation phenomena expected during alloy deployment (such as high-temperature helium embrittlement and cavity swelling for lead-cooled fast-reactor applications). Nanostructured materials are usually produced using a time-consuming and expensive batch process like mechanical alloying to achieve the fine homogenous distribution of nanoprecipitates throughout the matrix material. Integrating the nanoprecipitates in modern additive manufacturing processes has proven difficult, as the required nano-sizes or number densities cannot be achieved simultaneously. Efforts to increase the number density of precipitates by adding more precipitate-forming rare-earth elements led to agglomeration of such elements, while the nano-sized precipitates did not form in sufficient quantity when not enough rare-earth element was use. In this work a novel approach to advanced manufacturing and the fabrication of Nanostructured AFA (NAFA) materials was chosen. A dual precipitate-forming NAFA steel with a chemistry more suitable for advanced reactor applications was produced to create an environmentally resistant, high-sink-strength austenitic alloy for advanced reactor cladding applications.

36 MATERIALS SCIENCE↗

Space simulation experiments on reaction control system thruster plumes.

A space simulation procedure was developed for studying rocket plume contamination effects using a 5-lb bipropellant reaction control system thrustor. Vacuum chamber pressures of 0.00003 torr (70 miles altitude) were achieved with the thrustor firing in pulse trains consisting of eight pulses - 50 msec on, 100 msec off, and seven minutes between pulse trains. The final vacuum was achieved by cooling all vacuum chamber surfaces to liquid-helium temperature and by introducing a continuous argon leak of 48 std. cc/sec into the test chamber. Fast time response liquid flow rate measurements showed that large variations occurred in the ratio of oxidizer to fuel flow for pulse-on times up to 120 msec. These variations could lead to poor combustion efficiency and the production of contamination.

Cassidy, J. F.↗

Shuttle Infrared Telescope Facility

The Shuttle Infrared Telescope Facility (SIRTF) will combine high sensitivity with the flexibility offered by the Space Transportation System. A recently completed study has generated a preliminary design which demonstrates the feasibility of SIRTF. The 1.0 to 1.5 meter aperture, f/8 Gregorian telescope will be cooled to 20 K by a stored supercritical helium system. The telescope will be pointed and stabilized at two levels: the European-developed Instrument Pointing System provides primary pointing and stabilization; and an internal star tracker senses residual errors and drives a folding mirror inside the telescope to null the errors. The folding mirror can also be driven by square or triangular waves to provide space chopping or small-area scanning.

Mccarthy, S. G.↗

BASD: SIRTF Telescope Instrument Changeout and Cryogen Replenishment (STICCR) study

The Space Infrared Telescope Facility (SIRTF) is a long-life cryogenically cooled space-based telescope for infrared astronomy from 2 micrometer to 700 miocrometers currently under study by NASA-ARC, and planned for launch in approximately the mid 90's. SIRTF will operate as a multi-user facility, initially carrying 3 instruments at the focal plane. It will be cooled to below 2 K by superfluid liquid helium to achieve radiometric sensitivity limited only by the statistical fluctuations in the natural infrared background radiation over most of its spectral range. The lifetime of the mission will be limited by the lifetime of the liquid helium supply, and is currently baselined to be 2 years. The telescope changes required to allow in-space replenishment of the 2,000 liter superfluid helium tank are investigated. A preliminary design for the space services equipment is also developed. The impacts of basing the equipment and servicing on the space station are investigated. Space replenishment and changeout of instruments requires changes to the telescope design and preliminary concepts are presented.

Mord, A. J.↗

SIRTF Telescope Instrument Changeout and Cryogen Replenishment (STICCR) Study

The Space Infrared Telescope Facility (SIRTF) is a long-life cryogenically cooled space-based telescope for infrared astronomy from 2 to 700 micrometers. SIRTF is currently under study by NASA-ARC (Reference AP) and planned for launch in approximately the mid 1990s. SIRTF will operate as a multiuser facility, initially carrying three instruments at the focal plane. It will be cooled to below 2 K by superfluid liquid helium to achieve radiometric sensitivity limited only by the statistical fluctuations in the natural infrared background radiation over most of its spectral range. The lifetime of the mission will be limited by the lifetime of the liquid helium supply, and baseline is currently to be 2 years. The telescope changes required to allow in-space replenishment of the 4,000-L superfluid helium tank was investigated. A preliminary design for the space services equipment was also developed. The impacts of basing the equipment and servicing on the space station were investigated. Space replenishment and changeout of instruments required changes to the telescope design. Preliminary concepts are presented.

Nast, T. C.↗

The solar wind mass flux problem

The variation of the proton flux with coronal temperature and density in thermally driven solar wind models is discussed. It is shown that the rapid increase of the proton flux with increasing temperature can be reduced by adiabatic cooling of the expanding plasma. A significant coronal helium abundance can also act as a 'regulator' for the solar wind proton flux.

Leer, E.↗

A two-stage magnetic refrigerator for astronomical applications with reservoir temperatures above 4 K

We propose a novel adiabatic demagnetization refrigerator (ADR) to produce temperatures as low as 100 mK starting from a high temperature reservoir between 4 and 8 K. The high temperature reservoir for the ADR can be provided by a mechanical cooler or an unpumped liquid helium bath. This refrigerator can be used to cool bolometric infrared detectors for low background astronomy from mountain tops, balloons or satellites as well as to cool cryogenic x-ray detectors. The two-stage ADR consists of a single magnet with a paramagnetic chromic-cesium-alum (CCA) salt pill to produce the low temperature and paramagnetic gadolinium-gallium-garnet (GGG) as the first stage to intercept heat from the high temperature reservoir. Thermal contact between the paramagnets and the reservoir during magnetization is made with a mechanical heat switch. The ADR is suspended with Kevlar chords under tension for high mechanical stiffness and low parasitic heat leak. In a single cycle, the ADR maintains a temperature of 100 mK for 10 to 100 hours. This time depends strongly on the magnetic field and reservoir temperature but not on the volume of the paramagnetic material as long as the heat leak is dominated by the suspension.

Hagmann, C.↗

A three-dimensional solution for the orbit of Capella

We have combined new radial velocities of both components of Capella, obtained at McDonald and Kitt Peak, with those recently published by Batten et al. (1991), and with interferometric observations, to derive a new 3D orbit of the Capella system. Our results agree well with those of Bagnuolo and Hartkopf (1989), and yield masses accurate to +/- 3 percent. The cooler component, which is the fainter star visually but the more luminous one bolometrically, is the more massive. The mass ratio differs from unity by more than four times its uncertainty, and this lends strong support to the hypothesis that the cool component has begun to consume its core helium. If so, it may be possible to reconcile, qualitatively at least, the orbit's circularity and the stars' rotational velocities with theories of synchronization and circularization, such as that of the Tassouls (1992).

Barlow, D. J.↗