Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Effect of oxygen potential on Co solubility limit in La–Co co-substituted magnetoplumbite-type strontium ferrite

Highlights: • Oxygen pressure control dramatically affect the substitution range of La–Co co-substituted Sr M-type hexaferrite. • Successful synthesis of LaFe{sub 11}CoO{sub 19} under high oxygen pressure. • LaFe{sub 11}CoO{sub 19} achieves the highest anisotropic field. - Abstract: La–Co co-substituted magnetoplumbite-type (M-type) strontium ferrite is typically used as a base material for high-performance hard ferrite magnets. Generally, the unquenched orbital moment of Co{sup 2+}, substituted for Fe{sup 3+}, is thought to enhance magnetic anisotropy and then coercivity. La{sup 3+} is substituted for Sr{sup 2+} to compensate for the charge unbalance associated with Co{sup 2+} substitution. Even if the synthesis starts with equal amounts of Co and La, the Co contents of the resulting samples are generally lower than the La contents because of the partial reduction of Fe{sup 3+} to Fe{sup 2+}. We studied how the oxygen potential suppresses the formation of Fe{sup 2+} and expands the Co solubility range in this system. Polycrystalline samples, synthesized under oxygen partial pressures of 0.2, 1.0, and 387 atm, were characterized by powder X-ray diffraction, wavelength-dispersive X-ray analysis, and magnetization measurements. We reveal that the application of higher oxygen pressure dramatically expands the Co solubility range, resulting in the enhancement in magnetic anisotropy. We successfully synthesized Sr-free LaFe{sub 11}CoO{sub 19} with high magnetic anisotropy using the hot isostatic pressure (HIP) technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The dosimetric impact of daily setup error on target volumes and surrounding normal tissue in the treatment of prostate cancer with intensity-modulated radiation therapy

The purpose of this study was to evaluate the impact of daily setup error and interfraction organ motion on the overall dosimetric radiation treatment plans. Twelve patients undergoing definitive intensity-modulated radiation therapy (IMRT) treatments for prostate cancer were evaluated in this institutional review board-approved study. Each patient had fiducial markers placed into the prostate gland before treatment planning computed tomography scan. IMRT plans were generated using the Eclipse treatment planning system. Each patient was treated to a dose of 8100 cGy given in 45 fractions. In this study, we retrospectively created a plan for each treatment day that had a shift available. To calculate the dose, the patient would have received under this plan, we mathematically 'negated' the shift by moving the isocenter in the exact opposite direction of the shift. The individualized daily plans were combined to generate an overall plan sum. The dose distributions from these plans were compared with the treatment plans that were used to treat the patients. Three-hundred ninety daily shifts were negated and their corresponding plans evaluated. The mean isocenter shift based on the location of the fiducial markers was 3.3 {+-} 6.5 mm to the right, 1.6 {+-} 5.1 mm posteriorly, and 1.0 {+-} 5.0 mm along the caudal direction. The mean D95 doses for the prostate gland when setup error was corrected and uncorrected were 8228 and 7844 cGy (p < 0.002), respectively, and for the planning target volume (PTV8100) was 8089 and 7303 cGy (p < 0.001), respectively. The mean V95 values when patient setup was corrected and uncorrected were 99.9% and 87.3%, respectively, for the PTV8100 volume (p < 0.0001). At an individual patient level, the difference in the D95 value for the prostate volume could be >1200 cGy and for the PTV8100 could approach almost 2000 cGy when comparing corrected against uncorrected plans. There was no statistically significant difference in the D35 parameter for the surrounding normal tissue except for the dose received by the penile bulb and the right hip. Our dosimetric evaluation suggests significant underdosing with inaccurate target localization and emphasizes the importance of accurate patient setup and target localization. Further studies are needed to evaluate the impact of intrafraction organ motion, rotation, and deformation on doses delivered to target volumes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mechanical behavior of post-processed Inconel 718 manufactured through the electron beam melting process

Here, the electron beam melting (EBM) process was used to fabricate Inconel 718. The microstructure and tensile properties were characterized in both the as-fabricated and post-processed state transverse (T-orientation) and longitudinal (L-orientation) to the build direction. Post-processing involved both a hot isostatic pressing (HIP) and solution treatment and aging (STA) to homogenize the microstructure. In the as-fabricated state, EBM Inconel 718 exhibits a spatially dependent microstructure that is a function of build height. Spanning the last few layers is a cored dendritic structure comprised of the products (carbides and Laves phase) predicted under equilibrium solidification conditions. With increasing distance from the build's top surface, the cored dendritic structure becomes increasingly homogeneous with complete dissolution of the secondary dendrite arms. Further, temporal phase kinetics are observed to lead to the dissolution of the strengthening γ"γ" and precipitation of networks of fine δ needles that span the grains. Microstructurally, post-processing resulted in dissolution of the δ networks and homogeneous precipitation of γ'"γ'" throughout the height of the build. In the as-fabricated state, the monotonic tensile behavior exhibits a height sensitivity within the T-orientation at both 20 and 650 °C. Along the L-orientation, the tensile behavior exhibits strength values comparable to the reference wrought material in the fully heat-treated state. After post-processing, the yield strength, ultimate strength, and elongation at failure for the EBM Inconel 718 were observed to have beneficially increased compared to the as-fabricated material. Further, as a result of post-processing the spatial variance of the ultimate yield strength and elongation at failure within the transverse direction decreased by 4 and 3× respectively.

36 MATERIALS SCIENCE↗

Precipitation hardening of laser powder bed fusion Ti-6Al-4V

Here, the laser powder bed fusion (PBF-L) additive manufacturing (AM) community has dedicated significant efforts into process optimization and control for defect-free Ti-6Al-4V. As defects become less of an issue for PBF-L Ti-6Al-4V, the processing-structure-properties (PSP) relationships between AM microstructures can now be explored to optimize mechanical properties. Lower temperature aging treatments around 550 °C in wrought Ti-6A-4V have been historically understood to precipitation harden the α phase with an ordered, hexagonal close packed (HCP) α 2 phase. The α 2 phase existed as nanoscale Ti 3 Al precipitates coherent with the parent α phase. The goal of the present investigation was to implement a vacuum heat treatment of 545 °C for 100 hours on PBF-L Ti-6Al-4V. This vacuum heat treatment took place after an initial hot isostatic pressure (HIP) treatment that decomposed the as-built, martensitic microstructure. The vacuum aging successfully produced nanoscale precipitates of α 2 phase within α-laths, confirmed via atom probe tomography (APT). Microstructural-length scale and quasi-static mechanical properties were investigated by nanoindentation and uniaxial tensile tests of miniaturized test specimens. Given the sensitivity of Ti-6Al-4V mechanical properties to small changes in chemistry, all test specimens originated from the same build. The α 2 precipitation resulted in significantly harder α-laths (≈ 2 GPa) as measured via nanoindentation, as well as a relative yield and ultimate tensile strength increase of 60 MPa and 38 MPa, respectively. Analysis of Variance (ANOVA) of the datasets revealed no statistical differences in total elongation between the HIPed and HIPed + aged specimens, indicative of the aging treatment producing a net benefit of strength with no loss in ductility.

36 MATERIALS SCIENCE↗

Toward performance-portable PETSc for GPU-based exascale systems

The Portable Extensible Toolkit for Scientific computation (PETSc) library delivers scalable solvers for nonlinear time-dependent differential and algebraic equations and for numerical optimization. The PETSc design for performance portability addresses fundamental GPU accelerator challenges and stresses flexibility and extensibility by separating the programming model used by the application from that used by the library, and it enables application developers to use their preferred programming model, such as Kokkos, RAJA, SYCL, HIP, CUDA, or OpenCL, on upcoming exascale systems. Furthermore, a blueprint for using GPUs from PETSc-based codes is provided, and case studies emphasize the flexibility and high performance achieved on current GPU-based systems.

97 MATHEMATICS AND COMPUTING↗

Cobalt triggers necrotic cell death and atrophy in skeletal C2C12 myotubes

Severe poisoning has recently been diagnosed in humans having hip implants composed of cobalt–chrome alloys due to the release of particulate wear debris on polyethylene and ceramic implants which stimulates macrophagic infiltration and destroys bone and soft tissue, leading to neurological, sensorial and muscular impairments. Consistent with this premise, in this study, we focused on the mechanisms underlying the toxicity of Co(II) ions on skeletal muscle using mouse skeletal C2C12 myotubes as an in vitro model. As detected using propidium iodide incorporation, increasing CoCl{sub 2} doses (from 5 to 200 μM) affected the viability of C2C12 myotubes, mainly by cell necrosis, which was attenuated by necrostatin-1, an inhibitor of the necroptotic branch of the death domain receptor signaling pathway. On the other hand, apoptosis was hardly detectable as supported by the lack of caspase-3 and -8 activation, the latter resulting in only faint activation after exposure to higher CoCl{sub 2} doses for prolonged time points. Furthermore, CoCl{sub 2} treatment resulted in atrophy of the C2C12 myotubes which was characterized by the increased expression of HSP25 and GRP94 stress proteins and other typical 'pro-atrophic molecular hallmarks, such as early activation of the NF-kB pathway and down-regulation of AKT phosphorylation, followed by the activation of the proteasome and autophagy systems. Overall, these results suggested that cobalt may impact skeletal muscle homeostasis as an inducer of cell necrosis and myofiber atrophy. - Highlights: • The effects of cobalt on muscle myofibers in vitro were investigated. • Cobalt treatment mainly causes cell necrosis in skeletal C2C12 myotubes. • Cobalt impacts the PI3K/AKT and NFkB pathways and induces cell stress markers. • Cobalt induces atrophy of C2C12 myotubes through the activation of proteasome and autophagy systems. • Co treatment triggers NF-kB and PI3K/AKT pathways in C2C12 myotubes.

60 APPLIED LIFE SCIENCES↗

Hexavalent chromium induces chromosome instability in human urothelial cells

Numerous metals are well-known human bladder carcinogens. Despite the significant occupational and public health concern of metals and bladder cancer, the carcinogenic mechanisms remain largely unknown. Chromium, in particular, is a metal of concern as incidences of bladder cancer have been found elevated in chromate workers, and there is an increasing concern for patients with metal hip implants. However, the impact of hexavalent chromium (Cr(VI)) on bladder cells has not been studied. We compared chromate toxicity in two bladder cell lines; primary human urothelial cells and hTERT-immortalized human urothelial cells. Cr(VI) induced a concentration- and time-dependent increase in chromosome damage in both cell lines, with the hTERT-immortalized cells exhibiting more chromosome damage than the primary cells. Chronic exposure to Cr(VI) also induced a concentration-dependent increase in aneuploid metaphases in both cell lines which was not observed after a 24 h exposure. Aneuploidy induction was higher in the hTERT-immortalized cells. When we correct for uptake, Cr(VI) induces a similar amount of chromosome damage and aneuploidy suggesting that the differences in Cr(VI) sensitivity between the two cells lines were due to differences in uptake. The increase in chromosome instability after chronic chromate treatment suggests this may be a mechanism for chromate-induced bladder cancer, specifically, and may be a mechanism for metal-induced bladder cancer, in general. - Highlights: • Hexavalent chromium is genotoxic to human urothelial cells. • Hexavalent chromium induces aneuploidy in human urothelial cells. • hTERT-immortalized human urothelial cells model the effects seen in primary urothelial cells. • Hexavalent chromium has a strong likelihood of being carcinogenic for bladder tissue.

60 APPLIED LIFE SCIENCES↗

Composition of plastics from waste electrical and electronic equipment (WEEE) by direct sampling

Highlights: Black-Right-Pointing-Pointer The article shows WEEE plastics characterization from a recycling unit in Portugal. Black-Right-Pointing-Pointer The recycling unit has low machinery, with hand sorting of plastics elements. Black-Right-Pointing-Pointer Most common polymers are PS, ABS, PC/ABS, HIPS and PP. Black-Right-Pointing-Pointer Most plastics found have no identification of plastic type or flame retardants. Black-Right-Pointing-Pointer Ecodesign is still not practiced for EEE, with repercussions in end of life stage. - Abstract: This paper describes a direct analysis study carried out in a recycling unit for waste electrical and electronic equipment (WEEE) in Portugal to characterize the plastic constituents of WEEE. Approximately 3400 items, including cooling appliances, small WEEE, printers, copying equipment, central processing units, cathode ray tube (CRT) monitors and CRT televisions were characterized, with the analysis finding around 6000 kg of plastics with several polymer types. The most common polymers are polystyrene, acrylonitrile-butadiene-styrene, polycarbonate blends, high-impact polystyrene and polypropylene. Additives to darken color are common contaminants in these plastics when used in CRT televisions and small WEEE. These additives can make plastic identification difficult, along with missing polymer identification and flame retardant identification marks. These drawbacks contribute to the inefficiency of manual dismantling of WEEE, which is the typical recycling process in Portugal. The information found here can be used to set a baseline for the plastics recycling industry and provide information for ecodesign in electrical and electronic equipment production.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemical Evolution of CoCrMo Wear Particles: An in Situ Characterization Study

The unexpected high failure rates of CoCrMo hip implants are associated with the release of a large number of inflammatory wear particles. CoCrMo is nominally a stable material; yet, previous chemical speciation studies on CoCrMo wear particles obtained from periprosthetic tissue revealed only trace amounts of Co remaining despite Co being the major component of the alloy. The unexpected high levels of Co dissolution in vivo raised significant clinical concerns particularly related to the Cr speciation in the dissolution process. At high electrochemical potentials, the alloy’s Cr-rich passive film breaks down (transpassive polarization), facilitating alloy dissolution. The potential release of the carcinogenic Cr(VI) species in vivo has been a subject of debate. While the large-scale Co dissolution observed on in vivo produced particles could indicate a highly oxidizing in vivo environment, Cr(VI) species were not previously detected in periprosthetic tissue samples (except in the specific case of post-mortem tissue of diabetic patients). However, Cr(VI) is likely to be an unstable (transient) species in biological environments, and studies on periprosthetic tissue do not provide information about intermediate reaction products or the exposure history of the wear particles. In this work, an in Situ spectromicroscopy approach was developed, utilizing the high chemical resolution of synchrotron radiation, to study CoCrMo reactivity as a function of time and oxidizing conditions. The results reveal limited Co dissolution from CoCrMo particles, which increases dramatically at a critical electrochemical potential. Moreover, in Situ XAS detected only Cr(III) dissolution, even at potentials where Cr(VI) is known to be produced, suggesting that Cr(VI) species are extremely transient in simulated biological environments where the oxidation zone is small.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Discovery of a Selective Covalent Inhibitor of Lysophospholipase-like 1 (LYPLAL1) as a Tool to Evaluate the Role of this Serine Hydrolase in Metabolism

Lysophospholipase-like 1 (LYPLAL1) is an uncharacterized metabolic serine hydrolase. Human genome-wide association studies link variants of the gene encoding this enzyme to fat distribution, waist-to-hip ratio, and nonalcoholic fatty liver disease. We describe the discovery of potent and selective covalent small-molecule inhibitors of LYPLAL1 and their use to investigate its role in hepatic metabolism. In hepatocytes, selective inhibition of LYPLAL1 increased glucose production supporting the inference that LYPLAL1 is a significant actor in hepatic metabolism. The results provide an example of how a selective chemical tool can contribute to evaluating a hypothetical target for therapeutic intervention, even in the absence of complete biochemical characterization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linear complexions enable unprecedented ductility retention in neutron irradiated ferritic steel

Herein, the operando formation of Si-enriched linear complexions during neutron irradiation enables Grade 91 ferritic steel to overcome the strength–ductility tradeoff, one of the most critical life-limiting challenges facing nuclear structural alloys. Linear complexions are a distinct yet confined chemical and structural state at a dislocation, which are rarely reported in engineering alloys. Ferritic steels are amongst the most ubiquitous engineering alloys for current and future nuclear components, but they are susceptible to irradiation hardening and embrittlement. Here, exceptional ductility retention exceeding 90% of pre-irradiation levels is obtained in Grade 91 synthesized using powder metallurgy with hot isostatic pressing (PM-HIP). Powder processing artifacts promote a high density of screw dislocation arrays, on which β-FeSi 2 linear complexions form due to Si segregation during irradiation. Screw dislocation dipoles undergo pinning and unpinning on linear complexions, resulting in extended yielding and significant ductility retention post-irradiation. These findings represent a significant advancement toward design of alloys and manufacturing processes that can autonomously self-regulate their microstructural resilience in-operando during irradiation, enabling exceptional ductility rather than embrittlement.

Chatterjee, Arya [University of Illinois, Urbana, ↗

Imaging and speciation of intracellular metallic implant debris using synchrotron-based X-ray fluorescence micro-spectroscopy: a study of two cases

Debris generated from total hip arthroplasty (THA) components made from metal alloys can cause, in some cases, inflammatory cell (e.g., macrophages) responses that lead to adverse local tissue reactions (ALTR) and implant failure. The lack of information on intracellular chemical alterations of metal debris has hindered the understanding of the pathogenesis of ALTR. The goal of this study was to characterize intracellular debris within macrophages using Synchrotron imaging and spectroscopy. We studied periprosthetic tissues of two retrieved THAs with (1) a metal-on-metal (MoM) articulation and (2) a metal-on-polyethylene (MoP) articulation exhibiting corrosion of the metal femoral head. The MoM-THA exhibited different valence states of chromium- and cobalt-containing debris, suggesting three different moieties: Cr 2 O 3 , CrPO 4 , and an alloy-oxide mixture. The findings further suggest that Cr 2 O 3 formed in the tribological interfaces of the implant, while CrPO 4 is a by-product of the phagocytosis process of cobalt alloy-containing debris. Titanium debris appeared to occur in a mixed crystalline/amorphous oxide state. It remains unclear if this chemical state results from the tribochemical processes at the implant surface or intracellular alterations. The MoP-THA specimen exhibited no intracellular particulate debris associated with macrohpages, indicating that the ALTR may be entirely triggered by metal ionic species in this case. A better understanding of in vivo chemical alteration of implant debris will aid in assessing the risk for ALTR during implant design and material choice. However, various techniques are needed to accurately determine the interaction between metal particles and the inta- and extra-cellular environment.

60 APPLIED LIFE SCIENCES↗

Effect of displacement damage on the stability of oxide nanoparticles in model ODS alloys: TEM studies

Model ODS alloy containing Fe-0.3% yttria was prepared by ball milling and hipping at high temperature and the effect of irradiation on stability of yttria nanoclusters in model ODS alloy is studied by dual beam ion irradiation using 5 MeV Fe{sup +} and 1.5 MeV He{sup +} ions. TEM studies on irradiated sample show that these particles are stable at 25 dpa and 40 appm He concentration. However, at 80 dpa and 360 appm He concentration Yttria particles were found to be unstable as evidenced from increase in average particle size and particle size distribution.

36 MATERIALS SCIENCE↗

Laser shockwave technique for characterization of nuclear fuel plate interfaces

The US National Nuclear Security Agency is tasked with minimizing the worldwide use of high-enriched uranium. One aspect of that effort is the conversion of research reactors to monolithic fuel plates of low-enriched uranium. The manufacturing process includes hot isostatic press bonding of an aluminum cladding to the fuel foil. The Laser Shockwave Technique (LST) is here evaluated for characterizing the interface strength of fuel plates using depleted Uranium/Mo foils. LST is a non-contact method that uses lasers for the generation and detection of large amplitude acoustic waves and is therefore well adapted to the quality assurance of this process. Preliminary results show a clear signature of well-bonded and debonded interfaces and the method is able to classify/rank the bond strength of fuel plates prepared under different HIP conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bifurcation and chaos in the simple passive dynamic walking model with upper body

We present some rich new complex gaits in the simple walking model with upper body by Wisse et al. in [Robotica 22, 681 (2004)]. We first show that the stable gait found by Wisse et al. may become chaotic via period-doubling bifurcations. Such period-doubling routes to chaos exist for all parameters, such as foot mass, upper body mass, body length, hip spring stiffness, and slope angle. Then, we report three new gaits with period 3, 4, and 6; for each gait, there is also a period-doubling route to chaos. Finally, we show a practical method for finding a topological horseshoe in 3D Poincaré map, and present a rigorous verification of chaos from these gaits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synthesis of cobalt alloy through smelting method and its characterization as prosthesis bone implant

Cobalt-based alloys are widely used as total hip and knee replacements because of their excellent properties, such as corrosion resistance, fatigue strength and biocompatibility. In this work, cobalt alloys with variation of Cr (28.5; 30; 31.5; 33, and 34.5% wt) have been synthesized by smelting method began with the process of compaction, followed by smelting process using Tri Arc Melting Furnace at 200A. Continued by homogenization process at recrystallization temperature (1250° C) for 3 hours to allow the atoms diffuses and transform into γ phase. The next process is rolling process which is accompanied by heating at 1200° C for ± 15 minutes and followed by quenching. This process is repeated until the obtained thickness of ± 1 mm. The evaluated material properties included microstructure, surface morphology, and hardness value. It was shown that microstructure of cobalt alloys with variation of Cr is dominant by γ phase, thus making the entire cobalt alloys have high hardness. It was also shown from the surface morphology of entire cobalt alloys sample indicated the whole process of synthesis that had good solubility were at flat surface area. Hardness value test showed all of cobalt alloys sample had high hardness, just variation of 33% Cr be in the range of ASTMF75, it were 345,24 VHN which is potential to be applied as an implant prosthesis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A fast, dense Chebyshev solver for electronic structure on GPUs

Matrix diagonalization is almost always involved in computing the density matrix needed in quantum chemistry calculations. In the case of modest matrix sizes (≲4000), performance of traditional dense diagonalization algorithms on modern GPUs is underwhelming compared to the peak performance of these devices. This motivates the exploration of alternative algorithms better suited to these types of architectures. We newly derive, and present in detail, an existing Chebyshev expansion algorithm whose number of required matrix multiplications scales with the square root of the number of terms in the expansion. Focusing on dense matrices of modest size, our implementation on GPUs results in large speed ups when compared to diagonalization. Additionally, we improve upon this existing method by capitalizing on the inherent task parallelism and concurrency in the algorithm. Furthermore, this improvement is implemented on GPUs by using CUDA and HIP streams via the MAGMA library and leads to a significant speed up over the serial-only approach for smaller (≲1000) matrix sizes. Finally, we apply our technique to a model system with a high density of states around the Fermi level, which typically presents significant challenges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗