Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HELICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

NMR determination of an incommensurate helical antiferromagnetic structure in EuCo 2 As 2

In this paper, we report 153 Eu, 75 As, and 59 Co nuclear magnetic resonance (NMR) results on EuCo 2 As 2 single crystal. Observations of 153 Eu and 75 As NMR spectra in zero magnetic field at 4.3 K below an antiferromagnetic (AFM) ordering temperature T N = 45 K and its external magnetic field dependence clearly evidence an incommensurate helical AFM structure in EuCo 2 As 2 . Furthermore, based on 59 Co NMR data in both the paramagnetic and the incommensurate AFM states, we have determined the model-independent value of the AFM propagation vector k = (0,0,0.73 ± 0.07)2π/c, where c is the c lattice parameter. Finally, the incommensurate helical AFM state was characterized by only NMR data with model-independent analyses, showing NMR to be a unique tool for determination of the spin structure in incommensurate helical AFMs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NMR studies of the incommensurate helical antiferromagnet EuCo 2 P 2 : Determination of antiferromagnetic propagation vector

Recently, Q.-P. Ding et al. reported that their nuclear magnetic resonance (NMR) study on EuCo 2 As 2 successfully characterized the antiferromagnetic (AFM) propagation vector of the incommensurate helix AFM state, showing that NMR is a unique tool for determination of the spin structures in incommensurate helical AFMs. Motivated by this work, we have carried out 153 Eu, 31 P, and 59 Co NMR measurements on the helical antiferromagnet EuCo 2 P 2 with an AFM ordering temperature T N = 66.5 K. An incommensurate helical AFM structure was clearly confirmed by 153 Eu and 31 P NMR spectra on single-crystalline EuCo 2 P 2 in zero magnetic field at 1.6 K and its external magnetic field dependence. Furthermore, based on 59 Co NMR data in both the paramagnetic and incommensurate AFM states, we have determined the model-independent value of the AFM propagation vector k = (0,0,0.73±0.09)2π/c, where c is the c-axis lattice parameter. As a result, the temperature dependence of k is also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic structure and magnetization of helical antiferromagnets in high magnetic fields perpendicular to the helix axis at zero temperature

The zero-temperature angles of magnetic moments in a helix or sinusoidal fan confined to the x y plane, with respect to an in-plane magnetic field H x applied perpendicular to the z axis of a helix or fan, are calculated for commensurate helices and fans with field-independent turn angles k d between moments in adjacent layers of the helix or fan using the classical J 0 - J 1 - J 2 Heisenberg model. For 0 < k d < 4 π / 9 , first-order transitions from helix to a fan structure occur at fields H t as previously inferred, where the fan is found to be approximately sinusoidal. However, for 4 π / 9 ≤ k d ≤ π , different behaviors are found depending on the value of k d and these properties vary nonmonotonically with k d . In this k d range, the change from helix to fanlike structure is usually a crossover with no phase transition between them, although first-order transitions are found for k d = 3 π / 5 and 8 π / 11 and a second-order transition for k d = 3 π / 4 . At a critical field H c , the fan or fanlike structures exhibit a second-order transition to the paramagnetic state. The H c for a helix undergoing a field-induced change to a fan or fanlike structure is found to be the same as for a sinusoidal fan with the same k d and interlayer interactions. We present analytical expressions for H c versus k d. We also calculated the average x -axis moment per spin μ x ave versus H x for helices and fans with crossovers and phase transitions between them. When smooth helix to fanlike crossovers occur in the range 4 π / 9 ≤ k d ≤ π , μ x ave exhibits an S-shape behavior with increasing H x . The behavior we predict is consistent with μ x ave ( H x ) data previously reported by Sangeetha et al. [Phys. Rev. B 94, 014422 (2016)] for single-crystal EuCo 2 P 2 possessing a helix ground state with k d ≈ 0.85 π . The low-field magnetic susceptibility and the ratio H t / H c are calculated analytically or numerically versus k d for helices, and are shown to approach the respective known limits for k d → 0 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tuning the antiferromagnetic helical pitch length and nanoscale domain size in Fe 3 PO 4 O 3 by magnetic dilution

The insulating magnetic material Fe 3 PO 4 O 3 features a noncentrosymmetric lattice composed of Fe 3 + triangular units. Frustration, due to competing near-neighbor (J 1 ) and next-nearest-neighbor (J 2 ) antiferromagnetic interactions, was recently suggested to be the origin of an antiferromagnetic helical ground state with unusual needlelike nanoscale magnetic domains in Fe 3 PO 4 O 3 . Magnetic dilution is shown here to tune the ratio of these magnetic interactions, thus providing deeper insight into this unconventional antiferromagnet. Dilution of the Fe 3+ lattice in Fe 3 PO 4 O 3 was accomplished by substituting nonmagnetic Ga 3+ to form the solid solution series Fe 3-x Ga x PO 4 O 3 with x=0.012, 0.06, 0.25, 0.5, 1.0, 1.5. Magnetic susceptibility and neutron powder diffraction data from this series are presented. A continuous decrease of both the helical pitch length and the domain size is observed with increasing dilution up to at least x=0.25, while for x≥0.5, the compounds lack long-range magnetic order entirely. The decrease in the helical pitch length with increasing x can be qualitatively understood by reduction of the ratio of J 2 /J 1 in the Heisenberg model, consistent with mean-field considerations. Intriguingly, the magnetic correlation length in the ab plane remains nearly equal to the pitch length for each value of x≤0.25, showing that the two quantities are intrinsically connected in this unusual antiferromagnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Helical magnetism in Sr-doped CaM n 7 O 12 films

Noncollinear magnetism can play an important role in multiferroic materials but is relatively understudied in oxide heterostructures compared to their bulk counterparts. Using variable temperature magnetometry and neutron diffraction, we demonstrate the presence of helical magnetic ordering in CaMn 7 O 12 and Ca 1-x Sr x Mn 7 O 12 (for x up to 0.51) thin films. Consistent with bulk Ca 1-x Sr x Mn 7 O 12 , the net magnetization increases with Sr doping. Neutron diffraction confirms that the helical magnetic structure remains incommensurate at all values of x, while the fundamental magnetic wavevector increases upon Sr substitution. Lastly, this result demonstrates a chemical-based approach for tuning helical magnetism in quadruple perovskite films and enables future studies of strain and interfacial effects on helimagnetism in oxide heterostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gluon helicity in the nucleon from lattice QCD and machine learning

We present the first lattice QCD determination of the light cone gluon helicity correlation parton distribution function (PDF) with numerical evidence toward disfavoring negative gluon polarization in the nucleon. We present a solution for eliminating an inevitable contamination term that dominates the Euclidean correlations and makes determining gluon helicity PDF unfeasible. The proposed synergy between lattice QCD and artificial intelligence offers a superior platform to alleviate the defining challenge of extracting quark and gluon PDFs from the lattice data that are available in a limited domain due to a finite range of accessible hadron momenta. We suggest a systematically improvable method to extract PDFs from the lattice data, independent of inadequate parametrizations. The result of the gluon helicity will improve our understanding of the role of spin in the strong interaction and the nucleon-spin structure.

Lattice QCD↗

Helical vortex formation in three-dimensional electrochemical systems with ion-selective membranes

The rate of electric-field-driven transport across ion-selective membranes can exceed the limit predicted by Nernst (the limiting current), and encouraging this “overlimiting” phenomenon can improve efficiency in many electrochemical systems. Overlimiting behavior is the result of electroconvectively induced vortex formation near membrane surfaces, a conclusion supported so far by two-dimensional (2D) theory and numerical simulation, as well as experiments. We show that the third dimension plays a critical role in overlimiting behavior. In particular, the vortex pattern in shear flow through wider channels is helical rather than planar, a surprising result first observed in three-dimensional (3D) simulation and then verified experimentally. We present a complete experimental and numerical characterization of a device exhibiting this recently discovered 3D electrokinetic instability, and show that the number of parallel helical vortices is a jump-discontinuous function of width, as is the overlimiting current and overlimiting conductance. In addition, we show that overlimiting occurs at lower fields in wider channels, because the associated helical vortices are more readily triggered than the planar vortices associated with narrow channels (effective 2D systems). These unexpected width dependencies arise in realistic electrochemical desalination systems, and have important ramifications for design optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neoclassical Transport in the Helical Reversed-Field Pinch

Test particle evaluation of the diffusion coefficient in a fusion plasma in the reversed-field pinch (RFP) configuration shows distinct similarities with stellarators when the plasma spontaneously evolves towards a helical shape. The almost total absence of superbanana particles at the levels of helical deformation seen in experiment (B{sub h}/B=10%) causes transport to be proportional to collision frequency (at low collisions). This fact excludes the possibility that the minimum conceivable transport could be inversely proportional to collision frequency, which is typical of unoptimized stellarators. This result strengthens the perspectives of the helical RFP as a fusion configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helical Spin Order from Topological Dirac and Weyl Semimetals

In this paper, we study dynamical mass generation and the resultant helical spin orders in topological Dirac and Weyl semimetals, including the edge states of quantum spin Hall insulators, the surface states of weak topological insulators, and the bulk materials of Weyl semimetals. In particular, the helical spin textures of Weyl semimetals manifest the spin-momentum locking of Weyl fermions in a visible manner. Finally, the spin-wave fluctuations of the helical order carry electric charge density; therefore, the spin textures can be electrically controlled in a simple and predictable manner.

36 MATERIALS SCIENCE↗

Helical Edge States and Quantum Phase Transitions in Tetralayer Graphene

Helical conductors with spin-momentum locking are promising platforms for Majorana fermions. Here we report observation of two topologically distinct phases supporting helical edge states in charge neutral Bernal-stacked tetralayer graphene in Hall bar and Corbino geometries. As the magnetic field B ⊥ and out-of-plane displacement field D are varied, we observe a phase diagram consisting of an insulating phase and two metallic phases, with 0, 1, and 2 helical edge states, respectively. These phases are accounted for by a theoretical model that relates their conductance to spin-polarization plateaus. Transitions between them arise from a competition among interlayer hopping, electrostatic and exchange interaction energies. Finally, our work highlights the complex competing symmetries and the rich quantum phases in few-layer graphene.

36 MATERIALS SCIENCE↗

Phonon Helicity Induced by Electronic Berry Curvature in Dirac Materials

In two-dimensional insulators with time-reversal (TR) symmetry, a nonzero local Berry curvature of low-energy massive Dirac fermions can give rise to nontrivial spin and charge responses, even though the integral of the Berry curvature over all occupied states is zero. In this Letter, we present a new effect induced by the electronic Berry curvature. By studying electron-phonon interactions in BaMnSb2, a prototype two-dimensional Dirac material possessing two TR-related massive Dirac cones, we find that the nonzero local Berry curvature of electrons can induce a phonon angular momentum. The direction of this phonon angular momentum is locked to the phonon propagation direction, and thus we refer to it as “phonon helicity” in a way that is reminiscent of electron helicity in spin-orbit-coupled electronic systems. We discuss possible experimental probes of such phonon helicity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Janus skyrmion: Interfacial quasiparticle with two-faced helicity

Janus particles are functional particles with at least two surfaces showing asymmetric properties. Here, we show at the interface between two magnetic regions with different antisymmetric exchange interactions, an alternative species of two-dimensional topological quasiparticles can emerge, in which different helicity structures can coexist. We name such an interfacial quasiparticle a “Janus skyrmion,” in analogy to the Janus particle. As the Janus skyrmion shows helicity asymmetry, its size could vary with both the in-plane and out-of-plane magnetic fields. A vertical spin current could drive the Janus skyrmion into one-dimensional motion along the interface without showing the skyrmion Hall effect, at a speed which depends on both the in-plane spin-polarization direction and current density. Thermal fluctuations could also lead to one-dimensional random walk of a Brownian Janus skyrmion. This work uncovers unique dynamics intrinsic to interfacial quasiparticles with exotic helicity, which may be realized in interface-engineered magnetic layers.

36 MATERIALS SCIENCE↗

X-ray diffraction from nonuniformly stretched helical molecules

The fibrous proteins in living cells are exposed to mechanical forces interacting with other subcellular structures. X-ray fiber diffraction is often used to assess deformation and movement of these proteins, but the analysis has been limited to the theory for fibrous molecular systems that exhibit helical symmetry. However, this approach cannot adequately interpret X-ray data from fibrous protein assemblies where the local strain varies along the fiber length owing to interactions of its molecular constituents with their binding partners. To resolve this problem a theoretical formulism has been developed for predicting the diffraction from individual helical molecular structures nonuniformly strained along their lengths. This represents a critical first step towards modeling complex dynamical systems consisting of multiple helical structures using spatially explicit, multi-scale Monte Carlo simulations where predictions are compared with experimental data in a `forward' process to iteratively generate ever more realistic models. Here the effects of nonuniform strains and the helix length on the resulting magnitude and phase of diffraction patterns are quantitatively assessed. Examples of the predicted diffraction patterns of nonuniformly deformed double-stranded DNA and actin filaments in contracting muscle are presented to demonstrate the feasibly of this theoretical approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large Eddy Simulation of the Flow Behavior in a Simplified Helical Coil Steam Generator

Large eddy simulation (LES) is conducted for the flow over the shell side of a helical coil steam generator (HCSG) heat exchanger. Simulations are conducted on a simplified experimental test section that represents a one-column region of the helical coils using half-rods. Although the rods are wall-bounded, the flow still exhibits the turbulent characteristics and fluctuations from vortex shedding that one would expect from crossflow around a cylinder. The spectral element, computational fluid dynamics (CFD) code Nek5000, is used to capture the physics, and the results are compared with particle image velocimetry (PIV) measurements. In order to ensure that the turbulence is resolved, analysis is conducted by using the Taylor length scales and normalized wall distance. Sensitivity to the inlet boundary conditions (BCs) and the spatial discretization for different polynomial order solutions are also studied, finding only minor differences between each case. Pressure drop and velocity statistics show reasonable agreement with PIV. Proper orthogonal decomposition (POD) analysis reveals that the primary modes are similar between experiment and simulation, although the LES predicts higher turbulent kinetic energy than does PIV. Overall, the study establishes the resolution and resources required in order to conduct a high-fidelity simulation over 12 helical rods.

Lai, Jonathan K.↗

A three-dimensional statistical approach to improved image quality for multislice helical CT

Multislice helical computed tomography scanning offers the advantages of faster acquisition and wide organ coverage for routine clinical diagnostic purposes. However, image reconstruction is faced with the challenges of three-dimensional cone-beam geometry, data completeness issues, and low dosage. Of all available reconstruction methods, statistical iterative reconstruction (IR) techniques appear particularly promising since they provide the flexibility of accurate physical noise modeling and geometric system description. In this paper, we present the application of Bayesian iterative algorithms to real 3D multislice helical data to demonstrate significant image quality improvement over conventional techniques. We also introduce a novel prior distribution designed to provide flexibility in its parameters to fine-tune image quality. Specifically, enhanced image resolution and lower noise have been achieved, concurrently with the reduction of helical cone-beam artifacts, as demonstrated by phantom studies. Clinical results also illustrate the capabilities of the algorithm on real patient data. Although computational load remains a significant challenge for practical development, superior image quality combined with advancements in computing technology make IR techniques a legitimate candidate for future clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory motion effects on whole breast helical tomotherapy

The effects of intrafraction respiratory motion on nonhelical intensity-modulated radiotherapy have been well addressed in the literature, both theoretically and experimentally. However, the consequences of respiratory motion on helical tomotherapy, for patient-specific treatment plans, are less well known. Parameters specific to this treatment modality such as pitch, gantry speed, and degree of modulation may play prominent roles in radiation delivery with respect to intrafraction respiratory motion. This phantom-based study specifically addressed the effects of intrafraction respiratory motion on whole breast helical tomotherapy. A device capable of driving an acrylic phantom with reproducible, one-dimensional, anterior-posterior motion resembling a sinusoid of 4.6 mm crest-trough amplitude was developed. A plan to irradiate the corner of an acrylic phantom using parameters typical of a whole breast helical tomotherapy technique was developed using the TomoTherapy Hi-Art-II System registered . The treatment was delivered to the phantom, with Kodak EDR2 film in the axial plane, for each of the following conditions: (i) phantom at 270 deg. initial sinusoidal phase and 12 cycles/min motion, (ii) phantom at 270 deg. initial sinusoidal phase and 18 cycles/min motion, and (iii)-(v) phantom at 18 cycles/min motion with 0 deg., 90 deg., and 180 deg. initial sinusoidal phases. A measure of technique reproducibility was also performed for several irradiations with the phantom static at 270 deg. initial sinusoidal phase. Films were processed using a Kodak MIN-R mammography film processor, scanned with a Vidar NXR-16 Dosimetry Pro scanner and analyzed with RIT113 v.4.2 software. Films were compared to a reference film irradiated under the conditions of no motion and 270 deg. sinusoidal phase. For all comparisons, 5% dose difference threshold, 3% dose difference and 2 mm distance-to-agreement gamma analysis, and isodose plots were generated. The results of this study show a small area of greater than 5% decrease in dose at the phantom's anterior surface and a 1.5-3 mm posterior-medial shift of isodose lines in the penumbral and apex regions of the PTV. Frequency and phase effects are apparent within the PTV where dose varies with high spatial frequency. As the reference film was produced by delivering the treatment plan to the phantom static and in the position corresponding to maximum expiration, results are representative of extreme deviations between planned and delivered dose with respect to sinusoidal motion of clinically relevant magnitudes and frequencies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An absolute dose determination of helical tomotherapy accelerator, TomoTherapy High-Art II

Purpose: A helical tomotherapy accelerator presents a dosimetric challenge because, to this day, there is no internationally accepted protocol for the determination of the absolute dose. Because of this reality, we investigated the different alternatives for characterizing and measuring the absolute dose of such an accelerator. We tested several dosimetric techniques with various metrological traceabilities as well as using a number of phantoms in static and helical modes. Methods: Firstly, the relationship between the reading of ionization chambers and the absorbed dose is dependent on the beam quality value of the photon beam. For high energy photons, the beam quality is specified by the tissue phantom ratio (TPR{sub 20,10}) and it is therefore necessary to know the TPR{sub 20,10} to calculate the dose delivered by a given accelerator. This parameter is obtained through the ratio of the absorbed dose at 20 and 10 cm depths in water and was measured in the particular conditions of the tomotherapy accelerator. Afterward, measurements were performed using the ionization chamber (model A1SL) delivered as a reference instrument by the vendor. This chamber is traceable in absorbed dose to water in a Co-60 beam to a water calorimeter of the American metrology institute (NIST). Similarly, in Switzerland, each radiotherapy department is directly traceable to the Swiss metrology institute (METAS) in absorbed dose to water based on a water calorimeter. For our research, this traceability was obtained by using an ionization chamber traceable to METAS (model NE 2611A), which is the secondary standard of our institute. Furthermore, in order to have another fully independent measurement method, we determined the dose using alanine dosimeters provided by and traceable to the British metrology institute (NPL); they are calibrated in absorbed dose to water using a graphite calorimeter. And finally, we wanted to take into account the type of chamber routinely used in clinical practice and therefore measured the dose using a Farmer-type instrument (model NE 2571) as well. Results: We found the tomotherapy TPR{sub 20,10} value to be around 0.629, which is close to a 4 MV conventional linear accelerator value. During static irradiation, the secondary standard and the alanine dosimeters were compatible within 0.5%. The A1SL relative deviation to the secondary standard was 1.2% and the NE2571 relative deviation to the secondary standard was -1.7%. The measurement in dynamic helical mode found the different dosimeters compatible within 1.4% and the alanine dosimeters and the secondary standard were even found under 0.2%. Conclusions: We found that the different methods are all within uncertainties as well as globally coherent, and the specific limitations of the various dosimeters are discussed in order to help the medical physicist design an independent reference system. We demonstrated that, taking into account the particular reference conditions, one can use an ionization chamber calibrated for conventional linear accelerators to assert the absolute dose delivered by a tomotherapy accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The feasibility of head motion tracking in helical CT: A step toward motion correction

Purpose: To establish a practical and accurate motion tracking method for the development of rigid motion correction methods in helical x-ray computed tomography (CT). Methods: A commercially available optical motion tracking system provided 6 degrees of freedom pose measurements at 60 Hz. A 4 Multiplication-Sign 4 calibration matrix was determined to convert raw pose data acquired in tracker coordinates to a fixed CT coordinate system with origin at the isocenter of the scanner. Two calibration methods, absolute orientation (AO), and a new method based on image registration (IR), were compared by means of landmark analysis and correlation coefficient in phantom images coregistered using the derived motion transformations. Results: Transformations calculated using the IR-derived calibration matrix were found to be more accurate, with positional errors less than 0.5 mm (mean RMS), and highly correlated image voxel intensities. The AO-derived calibration matrix yielded larger mean RMS positional errors ( Asymptotically-Equal-To 1.0 mm), and poorer correlation coefficients. Conclusions: The authors have demonstrated the feasibility of accurate motion tracking for retrospective motion correction in helical CT. Their new IR-based calibration method based on image registration and function minimization was simpler to perform and delivered more accurate calibration matrices. This technique is a useful tool for future work on rigid motion correction in helical CT and potentially also other imaging modalities.

60 APPLIED LIFE SCIENCES↗