Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gamma decay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Photoproduction of the f 2 ( 1270 ) Meson Using the CLAS Detector

The quark structure of the f 2 ( 1270 ) meson has, for many years, been assumed to be a pure quark-antiquark (q$\bar{q}$) resonance with quantum numbers J PC = 2 ++ . Recently, it was proposed that the f 2 ( 1270 ) is a molecular state made from the attractive interaction of two ρ mesons. Such a state would be expected to decay strongly to final states with charged pions due to the dominant decay ρ → π + π - , whereas decay to two neutral pions would likely be suppressed. Here, we measure for the first time the reaction γp → π 0 π 0 p , using the CEBAF Large Acceptance Spectrometer detector at Jefferson Lab for incident beam energies between 3.6 and 5.4 GeV. Differential cross sections, dσ/dt , for f 2 ( 1270 ) photoproduction are extracted with good precision due to low backgrounds and are compared to theoretical calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision measurement of 65 Zn electron-capture decays with the KDK coincidence setup

65 Zn is a common calibration source, moreover used as a radioactive tracer in medical and biological studies. In many cases, γ-spectroscopy is a preferred method of 65 Zn standardization, which relies directly on the branching ratio of Jπ( 65 Zn) = 5/2- → Jπ( 65 Cu) = 5/2 - via electron capture (EC*). We measure the relative intensity of this branch to that proceeding directly to the ground state (EC 0 ) using a novel coincidence technique, finding I EC 0/IEC* = 0.9684 ± 0.0018. Re-evaluating the decay scheme of 65 Zn by adopting the commonly evaluated branching ratio of I β+ = 1.4271(7)% we obtain IEC* = (50.08 ± 0.06)%, and I EC 0 = (48.50 ± 0.06)%. The associated 1115 keV gamma intensity agrees with the previously reported NNDC value, and is now accessible with a factor of ~2 increase in precision. Our re-evaluation removes reliance on the deduction of this gamma intensity from numerous measurements, some of which disagree and depend directly on total activity determination. The KDK experimental technique provides a new avenue for verification or updates to the decay scheme of 65 Zn, and is applicable to other isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SMM hard X-ray observations of the soft gamma-ray repeater 1806-20

Six bursts from the soft gamma-ray repeater (SGR) 1806-20 have been recorded with the SMM Hard X-ray Burst Spectrometer during a highly active phase in 1983. Rise and decay times of less than 5 ns have been detected. Time profiles of these events indicate low-level emission prior to and after the main peaks. The results suggest that SGRs are distinguished from classical gamma-ray bursts by repetition, softer nonvarying spectra, short durations, simple temporal profiles, and a tendency for source locations to correlate with Population I objects. SGR characteristics differ from those of type I X-ray bursts, but they appear to have similarities with the type II bursts from the Rapid Burster.

Kouveliotou, C.↗

Total fusion yield measurements using deuterium–tritium gamma rays

The deuterium–tritium (DT) fusion reaction, D ( T , γ ) 5 He , has a rare (4.2 × 10 – 5 ) branching ratio that releases a ~16 MeV gamma ray instead of the more common 14.1 MeV fusion neutron. These fusion gamma rays can be used as a complementary source of measuring the net fusion yield of experiments. Fusion gamma rays have the advantage of having negligible Doppler broadening, being isotropic and less down-scattered compared to fusion neutrons. At the National Ignition Facility, we measured the DT fusion gamma rays by the Gamma Reaction History diagnostic that thresholds to only measure >10 MeV gamma rays. After removing a ~12% contribution from neutron capture interactions in deuterium, D ( n , γ ) T , and carbon, 12 C ( n , γ ) 13 C , the deviation between GRH measurements and neutron-based yield measurements has been reduced to 10%. Further improvements are needed for detailed physics comparison.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Superradiant pion clouds around primordial black holes

Here, we show that highly spinning primordial black holes of mass M ~ 10 12 kg, potentially born in a matter-dominated era after inflation, can produce clouds of pions in their vicinity via the superradiant instability, with densities up to that of nuclear matter. We discuss the electromagnetic signatures of this process, via neutral pion decay and charged pion annihilation into photons, computing in particular their contribution to the isotropic gamma-ray background. This allows us to place upper bounds on the abundance of such primordial black holes that are comparable to the ones obtained from Hawking evaporation. We also discuss the possibility of directly observing such clouds in high-redshift superclusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process. During irradiation, pressurized helium gas flows through 0.25 mm thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo-100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Longer duration testing will provide more data and verification for the findings presented in this report. The work will be continued in FY 24.

43 PARTICLE ACCELERATORS↗

Energy Dependent Fission Product Yields

This project utilized a 10-meter Fast Transfer System (called RABITTS) and Decay Station. FPYs are measured using neutron activation of U-235 and Pu-239 followed by gamma ray spectroscopy. We irradiated targets with mono-energetic neutrons produced at the TUNL tandem accelerator laboratory. The gamma spectra collected in these target irradiations are being analyzed to determine FPY values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Spatial modelling of total storm rainfall

The spatial structure of the depth of rainfall from a stationary storm event is investigated by using point process techniques. Cells are assumed to be stationary and to be distributed in space either independently according to a Poisson process, or with clustering according to a Neyman-Scott scheme. Total storm rainfall at the centre of each cell is a random variable and rainfall is distributed around the centre in a way specified by a spread function that may incorporate random parameters. The mean, variance and covariance structure of the precipitation depth at a point are obtained for different spread functions. For exponentially distributed centre depth and a spread function having quadratically exponential decay, the total storm depth at any point in the field is shown to have a gamma distribution. The probability of zero rainfall at a point is investigated, as is the stochastic variability of model parameters from storm to storm. Data from the Upper Rio Guaire basin in Venezuela are used in illustration.

Rodriguez-Iturbe, I.↗

Gamma-ray line emission from SN1987A

The inferred average line flux at about 847 keV in the background-subtracted spectrum of SN1987A from August 1 to October 31, 1987 is about (1.0 + or - 0.25) x 10 to the -3rd photons/sq cm/s at an energy of 843 + or - 5 keV. This feature cannot be explained by any statistical or systematic fluctuations observed in the seven previous years of gamma-ray spectrometer data. There is also evidence for the 1238-keV line from Co-56 decay, with an average flux of about (6 + or - 2) x 10 to the -4th photons/sq cm/s. This observation confirms that Co-56 is present in the supernova ejecta and that nucleosynthesis occurred during the explosion.

Matz, S. M.↗

Heterogeneous Reaction of ClONO2(g) + NaCl(s) to Cl2(g) + NaNO3(s)

The heterogeneous reaction of ClON02 + NaCl yields Cl2 + NaNO3 (eq 1) was investigated over a temperature range 220-300 K in a flow-tube reactor interfaced with a differentially pumped quadrupole mass spectrometer. Partial pressures of ClON02 in the range 10(exp -8) - 10(exp -5) Torr were used. Granule sizes and surface roughness of the NaCl substrates were determined by using a scanning electron microscope, and in separate experiments, surface areas of the substrates were measured by using BET analysis of gas-adsorption isotherms. For dry NaCl substrates, both the decay rates of ClON02 and the growth rates Of C12 were used to obtain reaction probabilities, gamma(sub l) = (4.6 +/- 3.0) x 10(exp -3) at 296 K and (6.7 +/- 3.2) x 10(exp -1) at 225 K, after considering the internal surface area, The error bars represent 1 standard deviation. The Cl2 yield based on the ClONO2 reacted was measured to be 1.0 +/- 0.2. In order to mimic the conditions encountered in the lower stratosphere, the effect of water vapor pressures between 5 x 10(exp -5) and 3 x 10(exp -4) Torr on reaction 1 was also studied. With added H20, reaction probabilities, gamma = (4.1 +/- 2.1) x 10(exp -3) at 296 K and (4.7 +/- 2.9) x 10(exp -3) at 225 K, were obtained. A trace of HOCl, the reaction product from the ClON02 + H20 yield HOCl + HN03 reaction, was observed in addition to the C12 product from reaction 1. The implications of this result for the enhancement of hydrogen chloride in the stratosphere after the El Chichon volcanic eruption and for the marine troposphere are discussed.

Timonen, Raimo S.↗

Ar Atmosphere: Implications for Structure and Composition of Mercury's Crust

We examine the possibilities of sustaining an argon atmosphere by diffusion from the upper 10 km of crust, and alternatively by effusion from a molten or previously molten area at great depth . Ar-40 in the atmospheres of the planets is a measure of potassium abundance in the interiors since Ar-40 is a product of radiogenic decay of K-40 by electron capture with the subsequent emission of a 1.46 eV gamma-ray. Although the Ar-40 in the earth's atmosphere is expected to have accumulated since the late bombardment, Ar-40 in surface-bounded exospheres is eroded quickly by photoionization and electron impact ionization. Thus, the argon content in the exospheres of the Moon, Mercury and probably Europa is representative of current effusion rather than accumulation over the lifetime of the body. Argon content will be a function of K content, temperature, grain size distribution, connected pore volume and possible seismic activity. Although Mercury and the Moon differ in many details, we can train the solutions to diffusion equations to predict the average lunar atmosphere. Then these parameters can be varied for Hermean conditions. Assuming a lunar crustal potassium abundance of 300 ppm, the observed argon atmosphere requires equilibrium between the argon production in the upper 9 Km of the moon (1.135 x 10(exp -3) cm(exp -3) s(exp -1)) and its loss. Hodges et al. conclude that this loss rate and the observed time variability requires argon release through seismic activity, tapping a deep argon source. An important observation is that the extreme surface of the Moon is enhanced in argon rather than depleted, as one would expect from outgassing of radiogenic argon. Manka and Michel concluded that ion implantation explains the surface enhancement of Ar-40. About half of the argon ions produced in the lunar atmosphere would return to the surface, where they would become embedded in the rocks. Similarly, at Mercury we expect the surface rocks to be enhanced in Ar-40 wherever the magnetosphere has been open over time. Thus the measurement of surface composition will reveal the long-term effects of solar wind-magnetosphere interaction. Additional information is contained in the original extended abstract.

Killen, R. M.↗

Reference Atmosphere for Mercury

We propose that Ar-40 measured in the lunar atmosphere and that in Mercury's atmosphere is due to current diffusion into connected pore space within the crust. Higher temperatures at Mercury, along with more rapid loss from the atmosphere will lead to a smaller column abundance of argon at Mercury than at the Moon, given the same crustal abundance of potassium. Because the noble gas abundance in the Hermean atmosphere represents current effusion, it is a direct measure of the crustal potassium abundance. Ar-40 in the atmospheres of the planets is a measure of potassium abundance in the interiors, since Ar-40 is a product of radiogenic decay of K-40 by electron capture with the subsequent emission of a 1.46 eV gamma-ray. Although the Ar-40 in the Earth's atmosphere is expected to have accumulated since the late bombardment, Ar-40 in the atmospheres of Mercury and the Moon is eroded quickly by photoionization and electron impact ionization. Thus, the argon content in the exospheres of the Moon and Mercury is representative of current effusion rather than accumulation over the lifetime of the planet.

Killen, Rosemary M.↗

Thermal Characterization of Tl 2 LiYCl 6 :Ce (TLYC)

Tl 2 LiYCl 6 :Ce (TLYC) is a new dual-detection elpasolite scintillator that can detect and distinguish between gamma rays and neutrons using pulse shape discrimination (PSD). It has a higher density and Z -number than the more mature and well-known elpasolite Cs 2 LiYCl 6 :Ce (CLYC), causing it to have a significantly better gamma-ray stopping power. These properties make TLYC an attractive alternative to CLYC for resource-constrained applications where size and weight are important, such as space or national security applications. Such applications may be subjected to a wide range of temperatures, and therefore, TLYC's performance was characterized for the first time over a temperature range of -20 °C to +50 °C in 10 °C increments. TLYC's thermal response effects on light-output linearity with energy, gamma-ray photopeak energy resolution, detected neutron energy, pulse shapes, and figure of merit (FOM) is analyzed and reported. The light output of TLYC was found to be linear with energy over the tested temperature range and was observed to decrease with increasing temperature. The decay time of the scintillation light output was observed to decrease with decreasing temperature at short times, leading to a decreasing PSD FOM. The gamma-ray photopeak energy resolution was also observed to degrade with decreasing temperature, due to an asymmetric broadening of the photopeak at low temperatures.

36 MATERIALS SCIENCE↗

Unraveling the Cooling Trend of the Soft Gamma Repeater SGR 1627-41

SGR 1627-41 was discovered in 1998 after a single active episode that lasted approximately 6 weeks. We report here our monitoring results of the decay trend of the persistent X-ray luminosity of the source during the last 5 years. We find an initial temporal power-law decay with index 0.47, reaching a plateau that is followed by a sharp (factor of 10) flux decline approximately 800 days after the source activation. The source spectrum is best described during the entire period by a single power law with high absorption [N(sub H) = 9.0(7) x 10(exp 22) per square centimeter]; the spectral index, however, varies dramatically between 2.2 and 3.8 spanning the entire range for all known soft gamma repeater sources. We discuss the cooling behavior of the neutron star assuming a deep crustal heating initiated by the burst activity of the source during 1998.

Kouveliotou, C.↗

Gamma and Neutron Measurement and Modeling of Irradiated TRISO Fuel

Given the unique characteristics of the PBR fuel cycle, both gamma and neutron measurements are expected to play important roles in performing and maintaining nuclear material control and accounting for spent pebbles to safeguard the fuel cycle. Given the lack of irradiated pebbles in the US, a variety of irradiated TRISO fuel samples with wide ranges of burnups and cooling times available at ORNL were used in this work. A large number of gamma and neutron measurements have been performed on these samples to collect data to test the various detectors and to benchmark the computer models to simulate the depletion and decay of the fuel and the measurements themselves. Two neutron detectors, including a custom-made detector and the Very High-Performance Neutron Multiplicity Counting, were used to measure the neutrons emitted by these TRISO samples. Three gamma spectrometry detectors, including an HPGe and the M400 CZT detector, were used to measure gamma-ray emissions from these samples. The M400 was recently adopted by the IAEA for fresh uranium measurements, but it was tested for spent fuel measurements prior to this project. Detailed MCNP models were developed to simulate these neutron and gamma measurements. Some GADRAS models were also developed to cross check the MCNP models for the gamma measurements. It was found challenging to perform neutron measurements in the hot cell due to the high background counts. Close agreements were observed between the simulated and measured neutron count rates in both detectors’ measurements of californium calibration sources. Both the HPGe and M400 detectors were able to measure the 604 and 662 keV peaks from these samples, which are the two most important peaks used to infer fuel burnup. Although the M400 detector did not have nearly good energy resolution and did not detect some of the minor peaks as the HPGe detector, it was found to be capable of handling significantly higher dose rates than HPGe. Given the complexities in the TRISO samples (e.g., different samples sizes) and uncertainties in the alignments between the detector and the TRISO fuel inside the containers, large scatters were found between the peak area rates and the samples’ burnups. However, the 604/662 peak ratios were found to trend well with the samples’ burnups among most samples in both measured and simulated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MADHAT: Model-Agnostic Dark Halo Analysis Tool

We present the Model-Agnostic Dark Halo Analysis Tool (MADHAT), a numerical tool which implements a Fermi-LAT data-driven, model-independent analysis of gamma-ray emission from dwarf satellite galaxies and dwarf galaxy candidates due to dark matter annihilation, dark matter decay, or other nonstandard or unknown astrophysics. This tool efficiently provides statistical upper bounds on the number of observed photons in excess of the number expected, based on empirical determinations of foregrounds and backgrounds, using a stacked analysis of any selected set of dwarf targets. It also calculates the resulting bounds on the properties of dark matter under any assumptions the user makes regarding dark sector particle physics or astrophysics. As an application, we determine new bounds on Sommerfeld-enhanced dark matter annihilation in a set of eight dwarfs. MADHAT v1.0 includes 58 dwarfs and dwarf candidate targets, and we discuss future planned developments. MADHAT is available and will be maintained at https://github.com/MADHATdm.

79 ASTRONOMY AND ASTROPHYSICS↗