Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Structure of the Soot Growth Region of Laminar Premixed Methane/Oxygen Flames

The structure of the soot growth region of laminar premixed methane/oxygen flames (fuel-equivalence ratios of 1.60-2.77) was studied both experimentally and computationally. Measurements were carried out in flames stabilized on a flat flame burner operated at standard temperature and pressure, and included velocities by laser velocimetry, soot volume fractions by laser extinction, soot temperatures by multiline emission, gas temperatures (where soot was absent) by corrected fine-wire thermocouples, major gas species concentrations by sampling and gas chromatography, and hydrogen atom concentrations by the Li/LiOH technique in conjunction with atomic absorption to find the proportion of free lithium in the flames. The measured concentrations of major gas species were in reasonably good agreement with predictions based on the detailed mechanisms of Leung and Lindstedt, and Frenklach and coworkers. The measurements also confirmed predictions of both these mechanisms that H-atom concentrations are in local thermodynamic equilibrium throughout the soot growth region even through the concentrations of major gas species are not. Thus, present findings support recent evaluations of the hydrogen-abstraction/carbon-addition (HACA) soot growth mechanism in similar flames, where the approximation that H-atom concentrations were in local thermodynamic equilibrium was adopted, based on predictions using the two mechanisms, due to the absence of direct H-atom concentration measurements.

Xu, F.↗

Indoor versus Outdoor Air Quality during Wildfires

The human behavioral modification recommendations during wildfire events are based on particulate matter and may be confounded by the potential risks of gas-phase pollutants such as polycyclic aromatic hydrocarbons (PAHs). Moreover, the majority of adults spend over 90 percent of their time indoors where there is an increased concern of indoor air quality during wildfire events. We address these timely concerns by evaluating paired indoor and outdoor PAH concentrations in residential locations and their relationship with satellite model-based categorization of wildfire smoke intensity. Low density polyethylene passive air samplers were deployed at six residential sites for one week in Eugene, Oregon with matched indoor and outdoor samples and twenty-four-hour time resolution. Samples were then quantitatively analyzed for 63 PAH concentrations using gas-chromatography. A probabilistic principal components analysis was used to reduce all 63 PAHs into an aggregate measure. Linear regression of the first principal component against indoor versus outdoor shows that indoor gas-phase PAH concentrations are consistently equal or greater than outdoor concentrations. Regression against a satellite-based model for wildfire smoke shows that outdoor, but not indoor gas-phase PAH concentrations are likely associated with wildfire events. Furthermore, these results point towards the need to include gas-phase pollutants such as PAHs in air pollution risk assessment.

54 ENVIRONMENTAL SCIENCES↗

GC/MS Gas Separator Operates At Lower Temperatures

Experiments show palladium/silver tube used to separate hydrogen carrier gas from gases being analyzed in gas-chromatography/mass-spectrometry (GC/MS) system functions satisfactorily at temperatures as low as 70 to 100 degrees C. Less power consumed, and catalytic hydrogenation of compounds being analyzed diminished. Because separation efficiency high even at lower temperatures, gas load on vacuum pump of mass spectrometer kept low, permitting use of smaller pump. These features facilitate development of relatively small, lightweight, portable GC/MS system for such uses as measuring concentrations of pollutants in field.

Sinha, Mahadeva P.↗

Hydrogen from low-density polyethylene via nonthermal plasma: Effects of energy density and process parameters

Nonthermal plasma processes are promising for the modular valorization of plastic waste, especially into hydrogen and carbon materials, due to their high intensity, lack of reliance on catalysts or consumables, and suitability to be directly powered by electricity. We investigate the production of hydrogen from low-density polyethylene (LDPE) as a plastic waste model using streamer Dielectric Barrier Discharge (sDBD) plasma in nitrogen at atmospheric pressure. Here, we examine the effects of process energy density (energy input per unit of feedstock mass), feedstock mass, and plasma intensity (electric voltage) on plasma properties, hydrogen yield and energy efficiency via gas chromatography, optical emission spectroscopy, and electrical diagnostics, together with reactor-scale and nonlinear electric circuit modeling. The characteristic temperature of free electrons in the sDBD plasma is approximately 15000 K (1.3 eV), and that of gas species 10 times lower, demonstrating strong thermal non-equilibrium that can lead to molecular bond scission via charged species impact rather than direct heating. Experimental results show that higher energy density leads to greater hydrogen production and diminishing energy efficiency, and that higher plasma intensity and larger feedstock mass lead to greater hydrogen yield due to higher plasma temperatures and enhanced energy fluxes to the feedstock.

08 HYDROGEN↗

Automated life-detection experiments for the Viking mission to Mars

As part of the Viking mission to Mars in 1975, an automated set of instruments is being built to test for the presence of metabolizing organisms on that planet. Three separate modules are combined in this instrument so that samples of the Martian surface can be subjected to a broad array of experimental conditions so as to measure biological activity. The first, the Pyrolytic Release Module, will expose surface samples to a mixture of C-14O and C-14O2 in the presence of Martian atmosphere and a light source that simulates the Martian visible spectrum. The assay system is designed to determine the extent of assimilation of CO or CO2 into organic compounds. The Gas Exchange Module will incubate surface samples in a humidified CO2 atmosphere. At specified times, portions of the incubation atmosphere will be analyzed by gas chromatography to detect the release or uptake of CO2 and several additional gases. The Label Release Module will incubate surface samples with a dilute aqueous solution of simple radioactive organic substrates in Martian atmosphere, and the gas phase will be monitored continuously for the release of labeled CO2.

Klein, H. P.↗

Application of a Modified Gas Chromatograph to Analyze Space Experiment Combustion Gases on Space Shuttle Mission STS-94

A space experiment designed to study the behavior of combustion without the gravitational effects of buoyancy was launched aboard the Space Shuttle Columbia on July 1, 1997. The space experiment, designated as Combustion Module-1 (CM-1), was one of several manifested on the Microgravity Sciences Laboratory - 1 (MSL-1) mission. The launch, designated STS-94, had the Spacelab Module as the payload, in which the MSL-1 experiments were conducted by the Shuttle crewmembers. CM-1 was designed to accommodate two different combustion experiments during MSL-1. One experiment, the Structure of Flame Balls at Low Lewis-number experiment (SOFBALL), required gas chromatography analysis to verify the composition of the known, premixed gases prior to combustion, and to determine the remaining reactant and the products resulting from the combustion process in microgravity. A commercial, off-the-shelf, dual-channel micro gas chromatograph was procured and modified to interface with the CM-1 Fluids Supply Package and the CM-1 Combustion Chamber, to accommodate two different carrier gases, each flowing through its own independent column module, to withstand the launch environment of the Space Shuttle, to accept Spacelab electrical power, and to meet the Spacelab flight requirements for electromagnetic interference (EMI) and offgassing. The GC data was down linked to the Marshall Space Flight Center for near-real time analysis, and stored on-orbit for post-flight analysis. The gas chromatograph operated successfully during the entire SOFBALL experiment and collected 309 runs. Because of the constraints imposed upon the gas chromatograph by the CM-1 hardware, system and operations, it was unable to measure the gases to the required accuracy. Future improvements to the system for a re-flight of the SOFBALL experiment are expected to enable the gas chromatograph to meet all the requirements.

Coho, William K.↗

Combining micro dry column chromatography and mass spectrometry

Dry column chromatography principles applied in microscale produce technique to minimize time in preparing and analyzing colorless constituents of soluble mixtures. Glass pipette microcolumns filled with finely sieved adsorbents permit capillary attraction and separation in 3 to 15 minutes. Technique is adaptable to gas chromatography.

Bauman, A. J.↗

Isotopic and Geochemical Investigation of Two Distinct Mars Analog Environments Using Evolved Gas Techniques in Svalbard, Norway

The 2010 Arctic Mars Analog Svalbard Expedition (AMASE) investigated two distinct geologic settings on Svalbard, using methodologies and techniques to be deployed on Mars Science Laboratory (MSL). AMASErelated research comprises both analyses conducted during the expedition and further analyses of collected samples using laboratory facilities at a variety of institutions. The Sample Analysis at Mars (SAM) instrument suite on MSL includes pyrolysis ovens, a gas-processing manifold, a quadrupole mass spectrometer (QMS), several gas chromatography columns, and a Tunable Laser Spectrometer (TLS). An integral part of SAM development is the deployment of SAM-like instrumentation in the field. During AMASE 2010, two parts of SAM participated as stand-alone instruments. A Hiden Evolved Gas Analysis- Mass Spectrometer (EGA-QMS) system represented the EGA-QMS component of SAM, and a Picarro Cavity Ring Down Spectrometer (EGA-CRDS), represented the EGA-TLS component of SAM. A field analog of CheMin, the XRD/XRF on MSL, was also deployed as part of this field campaign. Carbon isotopic measurements of CO2 evolved during thermal decomposition of carbonates were used together with EGA-QMS geochemical data, mineral composition information and contextual observations made during sample collection to distinguish carbonates formation associated with chemosynthetic activity at a fossil methane seep from abiotic processes forming carbonates associated with subglacial basaltic eruptions. Carbon and oxygen isotopes of the basalt-hosted carbonates suggest cryogenic carbonate formation, though more research is necessary to clarify the history of these rocks.

Svalbard↗

Oil in Alaska North Slope Gas Hydrate Reservoir: Micro-CT and Flow Simulation Insights into Permeability

Gas hydrate-bearing sands on the Alaska North Slope (ANS) host minor volumes of crude oil whose impact on formation permeability has never been quantified relative to a gas hydrate reservoir system. Here, we combine in situ pressure-core microcomputed-tomography (μ-CT), thermogravimetric analysis (TGA), gas-chromatography–mass-spectrometry (GC–MS), scanning-electron microscopy coupled with energy-dispersive spectroscopy (SEM-EDS), and Stokes-flow simulation to (i) quantify oil saturation, (ii) infer its source, and (iii) evaluate its influence on permeability after gas-hydrate dissociation. μ-CT and SEM-EDS imaging identify the host sediment as silty, with some grain-coating clay present. Eight representative 3003-voxel subvolumes extracted from a preserved pressure core (Core 15P-3c, from the B1 sand (unit B), HYDRATE 02 Geo Data Well (GDW), 886.96–887.29 m measured depth, MD) exhibit porosities of 0.34–0.37 and an average oil saturation of 0.09 ± 0.03, in comparison to an independent TGA-based estimate of 0.16. GC-MS fingerprints obtained from an adjacent depressurized core (Core 17P-1, 891.37–891.44 m MD), together with oil pore habit revealed by μ-CT, suggest that the oil is partly native but also includes contributions from mineral oil-based drilling fluid contamination. Further analysis of oil–porewater interactions and flushing tests confirms that native oil saturation in the analyzed samples ranges from 0.04 to 0.08 with an average of approximately 0.06, and the oil is highly immobile. Flow simulations demonstrate that the native oil saturation of ≈0.06 reduces permeability by approximately 50% due to both pore blockage and increased flow-path tortuosity. These findings reveal the potential presence of native oil within the ANS gas hydrate reservoir and suggest that future simulation models may need to account for its impact on permeability to improve long-term performance predictions of gas and water production.

02 PETROLEUM↗

Sustainable H 2 -Rich Syngas Production via Microwave-Assisted vs Conventional Catalysis of Pinewood

Catalytic gasification of biomass is a promising method for producing hydrogen-rich syngas, which is a valuable resource for cleanenergy applications. In this study, microwave-assisted biomass gasification was compared with conventional thermally driven biomass gasification using pinewood as the biomass without the use of external gasifying agents (such as air, steam, and CO 2 ), under non-catalytic and catalytic conditions. The catalysts consisted of either an iron or a nickel catalyst, and the pinewood used as biomass contained 42% oxygen. This comparative analysis explores the differences in reaction chemistry, product yields, and the role of key reactions such as the water gas shift (WGS) reaction, Boudouard reaction, etc. The gas-phase and liquid-phase products were analyzed using online gas chromatography, and the fresh and spent catalysts were analyzed using X-ray diffraction (XRD) techniques. It was found that microwave-assisted gasification offers advantages in terms of enhanced reaction efficiency, catalyst stability, and hydrogen yield. For the microwave-assisted reaction, the gas yield reached 87%, the char yield was 12.1%, and the tar yield was less than 1% (0.793%) at 550 °C. In contrast, thermal-assisted gasification using the same catalyst produced a gas yield of 85.796%, char yield of 11.438%, and higher tar yield of 2.8% at 900 °C. The higher microwave-assisted performance was attributed to faster heating and better control over reaction conditions, higher reaction rates, and more favorable conditions for hydrogen production.

biomass↗

Micro-Bubble Experiments at the Van de Graaff Accelerator

In order to test and verify the experimental designs at the linear accelerator (LINAC), several micro-scale bubble ("micro-bubble") experiments were conducted with the 3-MeV Van de Graaff (VDG) electron accelerator. The experimental setups included a square quartz tube, sodium bisulfate solution with different concentrations, cooling coils, gas chromatography (GC) system, raster magnets, and two high-resolution cameras that were controlled by a LabVIEW program. Different beam currents were applied in the VDG irradiation. Bubble generation (radiolysis), thermal expansion, thermal convection, and radiation damage were observed in the experiments. Photographs, videos, and gas formation (O 2 + H 2 ) data were collected. The micro-bubble experiments at VDG indicate that the design of the full-scale bubble experiments at the LINAC is reasonable.

43 PARTICLE ACCELERATORS↗

Development and implementation of high-throughput proteomic and metabolomics assays by using advanced chromatographic and mass spectrometric systems (CRADA Final Report)

The mission of this CRADA with Agilent was to couple powerful MS platforms (QQQ, IM-QTOFMS) with Agilent’s novel Ultra-High-Performance Liquid Chromatography (UHPLC) fast metabolomic workflows and perform ABF Machine Learning (ML) to generated datasets. Agilent transferred UHPLC methods to PNNL and LBNL and methods were implemented and demonstrated in both labs, achieving total acquisition times of < 10 min. Metabolites analyzed using Agilent’s shared methods included metabolites from central carbon metabolism, common across hosts, and metabolites unique to engineered strains. Standards were acquired in an UHPLC-Drift Tube Ion Mobility Mass Spectrometer (DTIMS) system for the first time within the context of ABF and methods were optimized based on Agilent’s protocols. Samples from ABF hosts Pseudomonas putida, Aspergillus pseudoterreus, Aspergillus niger and Rhodosporidium toruloides were analyzed using the UHPLC-DTIMS platform for a total of 276 runs. A data analysis workflow compatible with the Experimental Data Depot (EDD) and completely shareable was developed for the acquired UHPLC-DTIMS data. Samples were analyzed using a Data Independent Acquisition Approach (DIA), which for most of the standards provided more transitions therefore increasing detection confidence. Using the data acquired by PNNL, LBNL, and Agilent’s specifications from previous ML projects, SNL applied an ensemble ML strategy to pick the best performing model for automated LC-method selection. Finally, with the contribution of the participant labs and Agilent, SNL developed an Automated Method Selection (AMS) software tool to predict the best liquid chromatography method for analysis of any new molecules of interest. Samples with novel pathways and new metabolite targets of interest are generated at a high pace in the ABF. Overall, the project advanced rapid metabolomics by combining liquid chromatography, ion mobility spectrometry, and data-independent mass spectrometry with machine learning. This multidimensional approach uses retention time, collision cross-section, precursor mass, and fragment-ion information to distinguish chemically similar metabolites that can be difficult to resolve using conventional liquid- or gas-chromatography methods. The resulting workflow also provided automated metabolite-identification error estimates, addressing a recognized need for statistical confidence measures in metabolomics.

Petzold, Christopher [Lawrence Berkeley National L↗

Co-processing catalytic fast pyrolysis oil in an FCC reactor

Here, studies of co-processing catalytic fast pyrolysis (CFP) oil with vacuum gas oil (VGO) are conducted in a Davison Circulating Riser (DCR). The CFP oil (CFPO) for this study was produced by upgrading fast-pyrolysis vapors from pine in an ex-situ fixed-bed reactor. CFPOs were co-processed at up to a volume fraction of 0.05 with VGO at 521 degrees C and 257 kPa. The yields of oil, aqueous phase, tail gas, and coke were measured. The amount of coke was determined from the carbon containing components in the regenerator flue gas. A compositional analysis was conducted with gas chromatography and elemental analyzers. The organic liquids were distilled into gasoline, jet-fuel, diesel, and resid fractions. A biocarbon analysis was conducted on the organic phase and its individual boiling-point fractions. The results show a small decrease in liquid yield and a generally increased gas yield when co-processing CFPO with VGO. The experiments showed that 75%-100% of biocarbon is incorporated into liquid fuels relative to fossil carbon, depending on catalyst and CFPO. The measurements indicate that cracked CFPO components are predominantly included in the jet-fuel and diesel fractions. A techno-economic analysis (TEA) estimated the minimum fuel selling price (MSFP) for fuel-range products derived from FCC co-processing of CFPO at 24 to 29 $\$$/GJ ($\$$2.90 to $\$$3.50 per gasoline-gallon equivalent; GGE) at a yield of 4.87-7.14 GJ/t(biomass) or 40-58 GGE/t.

09 BIOMASS FUELS↗

Co-Processing Catalytic Fast Pyrolysis Oil in an FCC Reactor

Studies of co-processing catalytic fast pyrolysis (CFP) oil with vacuum gas oil (VGO) are conducted in a Davison Circulating Riser (DCR). The CFP oil (CFPO) for this study was produced by upgrading fast-pyrolysis vapors from pine in an ex-situ fixed-bed reactor. CFPOs were co-processed at up to 5 vol% with VGO at 521°C and 2.57 bar. The yields of oil, aqueous phase, tail gas, and coke were measured. The amount of coke was determined from the carbon containing components in the regenerator flue gas. A compositional analysis was conducted with gas chromatography and elemental analyzers. The organic liquids were distilled into gasoline, jet-fuel, diesel, and resid fractions. A biocarbon analysis was conducted on the organic phase and its individual boiling-point fractions. The results show a small decrease in liquid yield and a generally increased gas yield when co-processing CFPO with VGO. For experiments with E-Cat as catalyst, approximately 70% of biocarbon is incorporated into liquid fuels relative to fossil carbon, while more of the biocarbon is contained in tail gas (as carbon dioxide or olefins) and/or coke. The measurements indicate that cracked CFPO components are predominantly included in the jet-fuel and diesel fractions. A techno-economic analysis (TEA) estimated the minimum fuel selling price (MSFP) for fuel-range products derived from FCC co-processing of CFPO at $3 to $4 per gasoline-gallon equivalent (GGE) at a yield of 51 GGE per ton of biomass.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrochemical Decomposition of Primary Alcohol Groups in Deep Eutectic Solvents

This work investigates the electrochemical decomposition of an ethylene glycol/sodium chloride electrolyte and a deep eutectic solvent (DES) comprised of ethylene glycol/choline chloride (ethaline). Understanding these reactions can help to better understand the safety risks of overcharge when these electrolytes are used in a battery and to guide the design of DES electrolytes for improved electrochemical stability. Analysis of the decomposition products was performed using a combination of coulometry, gas chromatography, mass spectrometry, and Fourier transform infrared spectroscopy. It was found that even at relatively low (mM) concentrations of water, a stoichiometric rate of hydrogen is produced under cathodic conditions in both the ethaline and EG/NaCl electrolytes. This suggest an electrochemical hydrolysis cathodic decomposition reaction that produces both hydrogen gas and hydroxyl ions. This reaction was verified in both electrolytes by also identifying the liquid phase products. Only liquid phase products were observed under anodic conditions. A suspected alcohol oxidation to aldehyde anodic decomposition reaction was confirmed through a similar analysis of products. A tertiary alcohol only DES was investigated to eliminate these decomposition paths and was found to have increased stability window compared to the primary alcohol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas chromatographic concepts for the analysis of planetary atmospheres

Over the last few years, new gas chromatographic (GC) concepts were developed for use on board spacecraft or any other restricted environments for determining the chemical composition of the atmosphere and surface material of various planetary bodies. Future NASA Missions include an entry probe that will be sent to Titan and various spacecraft that will land on Mars. In order to be able to properly respond to the mission science requirements and physical restrictions imposed on the instruments by these missions, GC analytical techniques are being developed. Some of these techniques include hardware and mathematical techniques that will improve GC sensitivity and increase the sampling rate of a GC descending through a planetary atmosphere. The technique of Multiplex Gas Chromatography (MGC) is an example of a technique that was studied in a simulated Titan atmosphere. In such an environment, the atmospheric pressure at instrument deployment is estimated to be a few torr. Thus, at such pressures, the small amount of sample that is acquired might not be enough to satisfy the detection requirements of the gas chromatograph. In MGC, many samples are pseudo-randomly introduced to the chromatograph without regard to elution of preceding components. The resulting data is then reduced using mathematical techniques such as cross-correlation of Fourier Transforms. Advantages realized from this technique include: improvement in detection limits of several orders of magnitude and increase in the number of analyses that can be conducted in a given period of time. Results proving the application of MGC at very low pressures emulating the same atmospheric pressures that a Titan Probe will encounter when the instruments are deployed are presented. The sample used contained hydrocarbons that are expected to be found in Titan's atmosphere. In addition, a new selective modulator was developed to monitor water under Martian atmospheric conditions. Since this modulator is selective only to water, the need for a GC column is eliminated. This results in further simplification of the instrument.

Valentin, J. R.↗

Microfabricated fuel heating value monitoring device

A microfabricated fuel heating value monitoring device comprises a microfabricated gas chromatography column in combination with a catalytic microcalorimeter. The microcalorimeter can comprise a reference thermal conductivity sensor to provide diagnostics and surety. Using microfabrication techniques, the device can be manufactured in production quantities at a low per-unit cost. The microfabricated fuel heating value monitoring device enables continuous calorimetric determination of the heating value of natural gas with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This device has applications in remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. For gas pipelines, the device can improve gas quality during transfer and blending, and provide accurate financial accounting. For industrial end users, the device can provide continuous feedback of physical gas properties to improve combustion efficiency during use.

47 OTHER INSTRUMENTATION↗

Air separation via two-step solar thermochemical cycles based on SrFeO 3-δ and (Ba,La) 0.15 Sr 0.85 FeO 3-δ perovskite reduction/oxidation reactions to produce N 2 : rate limiting mechanism(s) determination

Two-step solar thermochemical cycles based on reversible reactions of SrFeO 3–δ and (Ba,La) 0.15 Sr 0.85 FeO 3–δ perovskites were considered for air separation. The cycle steps encompass (1) the thermal reduction of SrFeO 3–δ or (Ba,La) 0.15 Sr 0.85 FeO 3–δ perovskites driven by concentrated solar irradiation and (2) oxidation in air to remove O 2 and produce N 2 . Rate limiting mechanisms were examined for both reactions using a combination of isothermal and non-isothermal thermogravimetry for temperature-swings between 673 and 1373 K, heating rates of 10, 20, and 50 K min –1 , and O 2 pressure-swings between 20% O 2 /Ar and 100% Ar at atmospheric pressure. Evolved O 2 and associated lag due to transport behavior were measured with gas chromatography and used with measured sample temperatures to predict equilibrium compositions from a compound energy formalism thermodynamic model. Measured and predicted chemical equilibrium changes in deviation from stoichiometry were compared. Rapid chemical kinetics were observed as the samples equilibrated rapidly for all conditions, indicative that heat and mass transfer were the rate limiting mechanisms. Furthermore, the effects of bulk diffusion (or gas diffusion through the bed or pellet) were examined using pelletized and loose powdered samples and determined to have no discernable impact.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗